首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Zauner G  Deelder AM  Wuhrer M 《Electrophoresis》2011,32(24):3456-3466
This review presents recent progress in employing hydrophilic interaction liquid chromatography (HILIC) for glycan and glycopeptides analysis. After an introduction of this technique, the following themes are addressed: (i) implementation of HILIC in large-scale studies for analyzing the human plasma N-glycome; (ii) the use of HILIC UPLC (ultrahigh pressure liquid chromatography) for fast high-resolution runs and its successful application with online MS for glycan and glycopeptide analysis; (iii) high-throughput profiling using HILIC solid-phase extraction in combination with MS detection; (iv) HILIC sample preparation for CE and CGE; (v) the latest glycoproteomic approaches implementing HILIC separation; (vi) future perspectives of HILIC including its use in large-scale glycoproteomics studies such as the analysis of entire glycoproteomes at the glycopeptide level.  相似文献   

2.
This review represents a summary of the development and application of a novel mixed-mode HPLC approach to the separation and analysis of peptides and proteins termed hydrophilic interaction/cation-exchange chromatography (HILIC/CEX). This approach combines the most advantageous aspects of two widely different separation mechanisms, i.e. a separation based on hydrophilicity/hydrophobicity differences between polypeptides overlaid on a separation based on net charge. Applications described include HILIC/CEX separations of cyclic peptides, alpha-helical peptides, random coil peptides and modified or deletion products of synthetic peptides. In addition, the excellent resolving ability of HILIC/CEX for modified histone proteins is described. This approach is shown to represent an excellent complement to RP chromatography (RPC), as well as being a potent analytical tool in its own right.  相似文献   

3.
Homocitrulline (HCit), an amino acid formed by the carbamylation of ε-amino groups of lysine residues, is considered a promising biomarker for monitoring diseases such as chronic renal failure and atherosclerosis. This paper describes a tandem mass spectrometric method for total, protein-bound and free HCit measurement in plasma samples. HCit was separated from other plasma components by hydrophilic interaction liquid chromatography. Detection was achieved by monitoring transitions of 190.1 > 127.1 and 190.1 > 173.1 for HCit, and 183.1 > 120.2 for d7-citrulline used as internal standard. This method allowed HCit quantification within 5.2 min and was precise (inter-assay CV < 5.85%), accurate (mean recoveries ranging from 97% to 106%), and exhibited a good linearity from 10 nmol/L to 1.6 μmol/L. Plasma samples from control and uremic mice (n = 10) were analyzed. In control mice, mean total plasma HCit concentration was 0.78 ± 0.12 μmol/mol amino acids, whereas it was increased 2.7-fold in uremic mice plasma, reaching 2.10 ± 0.50 μmol/mol amino acids (p < 0.001). In conclusion, this method exhibits good analytical performances and meets the criteria of sensitivity suitable for HCit concentration assessment in plasma samples.  相似文献   

4.
In proteomics, nanoflow multidimensional chromatography is now the gold standard for the separation of complex mixtures of peptides as generated by in-solution digestion of whole-cell lysates. Ideally, the different stationary phases used in multidimensional chromatography should provide orthogonal separation characteristics. For this reason, the combination of strong cation exchange chromatography (SCX) and reversed-phase (RP) chromatography is the most widely used combination for the separation of peptides. Here, we review the potential of hydrophilic interaction liquid chromatography (HILIC) as a separation tool in the multidimensional separation of peptides in proteomics applications. Recent work has revealed that HILIC may provide an excellent alternative to SCX, possessing several advantages in the area of separation power and targeted analysis of protein post-translational modifications. Figure Artistic impression of the HILIC separation mechanism  相似文献   

5.
A method for the preparation of poly(N-vinylpyrrolidone-co-pentaerythritol triacrylate copolymerization)-based monolithic capillary column was reported for the separation of polar small molecular weight compounds with nano-liquid chromatography in hydrophilic interaction chromatography mode. The monolithic columns were prepared by in situ copolymerization of N-vinylpyrrolidone and a cross-linker pentaerythritol triacrylate in a binary porogenic agent consisting of methanol and water. The composition of the polymerization solution was systematically optimized in terms of column permeability, theoretical plate number, asymmetric factor, and retention factor. A typical hydrophilic chromatography retention mechanism was observed with a mobile phase composed of a high content of organic solvent. The preparation method is simple and robust, the precursor N-vinylpyrrolidone is chemically stable, cheap, and easily available. The N-vinylpyrrolidone-based hydrophilic interaction chromatography stationary phase displays satisfactory separation selectivity for a range of polar test analytes, including benzoic acid derivatives, nucleosides, and phenols.  相似文献   

6.
赵艳艳  郭志谋  李秀玲  梁鑫淼 《色谱》2013,31(8):763-768
以标准蛋白质α-酪蛋白的酶解液作为研究对象,考察流动相pH值对磷酸化肽在Click OEG-CD材料上富集选择性的影响。首先以磷酸苯二钠作为模型化合物考察流动相pH值对其在Click OEG-CD材料上的保留影响,结果表明当pH值低于磷酸根的pKa值时,磷酸苯二钠难以电离,与材料的离子交换作用较弱,因而保留也较弱。然后在亲水模式下流动相pH值分别为2, 4, 6时考察Click OEG-CD材料对α-酪蛋白的酶解液中磷酸化肽的富集选择性影响。结果表明,当流动相pH为2时,磷酸化肽不能被材料富集;当pH为4时,磷酸化肽能够被富集,而且洗脱窗口较窄;当pH为6时,磷酸化肽也能够被富集,但是洗脱窗口较宽。因此适合亲水模式下富集磷酸化肽的流动相pH值为4。本研究结果能够为今后将Click OEG-CD材料更好的应用于磷酸化肽富集提供有意义的借鉴。  相似文献   

7.
Relative changes in the hydrophobicity and shape selectivity of standard analytes are shown to be a valuable method to monitor the reproducibility of the effective temperature experienced by the analytes in a chromatographic column in different ovens. Significant differences were observed between ovens with the same nominal temperature and could be a major cause of problems encountered in transferring methods between instruments or laboratories. By using two parameters, changes due to the column temperature can be distinguished from those caused by mobile phase composition differences. In addition marked increases in column efficiency were noted as the mobile phase temperature was reduced below the column temperature in contrast to claims that thermal equilibration is essential.  相似文献   

8.
More and more polar stationary phases have become available for the separation of small polar compounds in the past decade as hydrophilic interaction chromatography (HILIC) continues to find applications in new fields (e.g., metabolomics and proteomics). Bare silica phases remain popular, especially in the bio-analytical area. A wide range of functional groups (e.g., amino, amide, diol, sulfobetaine, and triazole) have been employed as polar stationary phases for HILIC separation. This review provides a survey of the popular stationary phases commercially available and discusses the retention and selectivity characteristics of the polar stationary phases in HILIC. The purpose of the review is not to provide a comprehensive overview of literature reports, but rather focuses on findings that demonstrate retention and selectivity of the polar stationary phases in HILIC.  相似文献   

9.
The influence of the mobile phase and temperature, on the retention behavior of seven aliphatic acids (pyruvic, gluconic, 2‐oxoglutaric, tartaric, malic, oxalic, and citric acid) in hydrophilic interaction liquid chromatography on zwitterionic stationary phases with sulfobetaine and phosphorylcholine ligands is investigated. In agreement with the van't Hoff model, most acids show linear ln k versus 1/T plots. However, the retention of structurally symmetrical oxalic and tartaric dicarboxylic acids is almost independent of temperature, or slightly increases at rising temperature. The experimental parameters of the van't Hoff plots suggest positive entropic contributions to the retention of these symmetrical acids, possibly connected with changes in molecular symmetry on their adsorption. The type of the zwitterionic stationary phase and the mobile phase composition (the molar concentration of acetate buffer and the volume fraction of acetonitrile) affect the retention and the selectivity of the separation of the acids.  相似文献   

10.
A novel porous zwitterionic monolith was prepared by thermal co-polymerisation of 2-methacryloyloxyethyl phosphorylcholine (MPC) and ethylene glycol dimethacrylate (EDMA) within 100 μm I.D. capillaries. Mercury intrusion porosimetry, scanning electron microscopy (SEM), micro-HPLC (μ-HPLC), elemental analysis and ζ-potential analysis were used to evaluate the monolithic structure. No evidence of swelling or shrinking of the monolith in different polarity solvents was observed. A typical hydrophilic liquid chromatography (HILIC) mechanism was observed at high organic solvent content (acetonitrile >60%). The phosphorylcholine (PC) functionality has both a positively charged quaternary ammonium and a negatively charged phosphate group. For charged analytes, a weak electrostatic interaction was also observed by studying the influence of mobile phase pH and salt concentration on their retentions on the poly(MPC-co-EDMA) monolithic column. The optimised poly(MPC-co-EDMA) monolith showed very good selectivities for a range of polar test analytes, especially small peptides. This might be ascribed to the good biocompatibility of PC functionality. At low organic solvent content, baseline separation was also observed for a test mixture of seven alkylphenones by a reversed-phase separation mechanism.  相似文献   

11.
Adopting a stationary phase convention circumvents problematic definition of the boundary between the stationary and the mobile phase in the liquid chromatography, resulting in thermodynamically consistent and reproducible chromatographic data. Three stationary phase definition conventions provide different retention data, but equal selectivity: (i) the complete solid phase moiety; (ii) the solid porous part carrying the active interaction centers; (iii) the volume of the inner column pores. The selective uptake of water from the bulk aqueous‐organic mobile phase significantly affects the volume and the properties of polar stationary phases. Some polar stationary phases provide dual‐mode retention mechanism in aqueous‐organic mobile phases, reversed‐phase in the water‐rich range, and normal‐phase at high concentrations of the organic solvent in water. The linear solvation energy relationship model characterizes the structural contributions of the non‐selective and selective polar interactions both in the water‐rich and organic solvent‐rich mobile phases. The inner‐pore convention provides a single hold‐up volume value for the retention prediction on the dual‐mode columns over the full mobile phase range. Using the dual‐mode monolithic polymethacrylate zwitterionic micro‐columns alternatively in each mode in the first dimension of two‐dimensional liquid chromatography, in combination with a short reversed‐phase column in the second dimension, provides enhanced sample information.  相似文献   

12.
Ohne ZusammenfassungComplete data (chromatograms and tables) can be provided by the editor upon request.  相似文献   

13.
A polyacrylamide (PAAm)-modified monolithic silica capillary column of increased phase ratio, 200T-PAAm, for hydrophilic interaction liquid chromatography (HILIC) was prepared. The column showed high separation efficiency, with a theoretical plate height H = 7–20 μm at a linear velocity, u = 1–7 mm/s. From a kinetic plot analysis, it was expected that the monolithic column could provide three times faster separation than particle-packed HILIC columns under a pressure limit at 20 MPa. HILIC coupled with electrospray ionization (ESI)–mass spectrometry (HILIC-ESI-MS) using the 200T-PAAm column was employed for the analysis of underivatized carbohydrates to achieve fast and efficient separations of mixtures containing mono-, di-, and trisaccharides within 5 min. Under single MS full scan mode, 200 pg of oligosaccharides was detected by the system. The limit of detection (LOD) of the LC-ESI-MS/MS system was determined using selected reaction monitoring (SRM) to be as low as 3.2 ng/mL (attomol level) for nonreducing saccharides. The system was successfully applied to the detection of disaccharides in extracts of plant, such as corn, soybean, and Arabidopsis thaliana. Figure HILIC-ESI-MS provides a high-efficiency separation and sensitive detection of underivatized carbohydrate oligomers, e.g., the homologs of glucose (1) up to maltoheptaose (7)  相似文献   

14.
谭婷  乔鑫  万益群  邱洪灯 《色谱》2015,33(9):934-937
低共熔溶剂被用作亲水作用色谱流动相的新型改性剂。选用硅胶柱(150 mm×4.6 mm, 3 μm),以乙腈与低共熔溶剂(氯化胆碱-乙二醇(摩尔比为1:3))的混合溶液为流动相,考察了6个碱基与核苷的色谱分离效果,并讨论了低共熔溶剂在流动相中的比例及温度条件对分离的影响。结果表明,与传统的水相流动相条件相比,在加入低共熔溶剂改性后的流动相条件下,碱基与核苷分离效果得到明显的改善,尤其是胞嘧啶与胞苷能达到完全分离;同时,随着低共熔溶剂在乙腈中浓度的增加,6个碱基与核苷在色谱柱上的保留均有不同程度的减小,其中胞苷的保留减小最为显著;随着柱温的升高,碱基与核苷的保留同样有所减小。本文验证了低共熔溶剂作为亲水作用色谱流动相改性剂的可行性,可在一定程度上解决传统亲水作用色谱分离的困难。  相似文献   

15.
Hydrophilic interaction chromatography (HILIC) is valuable alternative to reversed-phase liquid chromatography separations of polar, weakly acidic or basic samples. In principle, this separation mode can be characterized as normal-phase chromatography on polar columns in aqueous-organic mobile phases rich in organic solvents (usually acetonitrile). Highly organic HILIC mobile phases usually enhance ionization in the electrospray ion source of a mass spectrometer, in comparison to mobile phases with higher concentrations of water generally used in reversed-phase (RP) LC separations of polar or ionic compounds, which is another reason for increasing popularity of this technique. Various columns can be used in the HILIC mode for separations of peptides, proteins, oligosaccharides, drugs, metabolites and various natural compounds: bare silica gel, silica-based amino-, amido-, cyano-, carbamate-, diol-, polyol-, zwitterionic sulfobetaine, or poly(2-sulphoethyl aspartamide) and other polar stationary phases chemically bonded on silica gel support, but also ion exchangers or zwitterionic materials showing combined HILIC-ion interaction retention mechanism. Some stationary phases are designed to enhance the mixed-mode retention character. Many polar columns show some contributions of reversed phase (hydrophobic) separation mechanism, depending on the composition of the mobile phase, which can be tuned to suit specific separation problems. Because the separation selectivity in the HILIC mode is complementary to that in reversed-phase and other modes, combinations of the HILIC, RP and other systems are attractive for two-dimensional applications. This review deals with recent advances in the development of HILIC phase separation systems with special attention to the properties of stationary phases. The effects of the mobile phase, of sample structure and of temperature on separation are addressed, too.  相似文献   

16.
A stationary phase composed of silica-bonded cyclofructan 6 (FRULIC-N) was evaluated for the separation of four cyclic nucleotides, six nucleoside monophosphates, four nucleoside diphosphates, and five nucleoside triphosphates via hydrophilic interaction chromatography (HILIC) in both isocratic and gradient conditions. The gradient conditions gave significantly better separations by narrowing peak widths. Sixteen out of nineteen nucleotides were baseline separated on the FRULIC-N column in one run. Unlike other known HILIC stationary phases, there can be dual-retention mechanisms unique to this media. Traditional hydrogen bonding/dipolar interactions can be supplemented by dynamic ion interaction effects for anionic analytes. This occurs because the FRULIC-N stationary phase is able to bind certain buffer cations. The extent of the ion interaction is tunable, in comparison to stationary phases with embedded charged groups, where the inherent ionic properties are fixed. The best mobile phase conditions were determined by varying the organic modifier (acetonitrile) content, as well as salt type/concentration and electrolyte pH. The thermodynamic characteristic of the FRULIC-N column was investigated by evaluating the column temperature effect on retention and utilizing van’t Hoff plots. This study shows that there is a greater entropic contribution for the retention of nucleotide di and triphosphates, whereas there is a greater enthalphic contribution for the cyclic nucleotides with the FRULIC-N column.  相似文献   

17.
A novel zwitterionic hydrophilic porous monolithic stationary phase was prepared based on the thermal‐initiated copolymerization of N,N‐dimethyl‐N‐(3‐methacryl‐amidopropyl)‐N‐(3‐(sulfopropyl)ammonium betaine and ethylene glycol dimethacrylate. A typical hydrophilic separation mechanism was observed at a highly organic mobile phase (ACN >60%) on this optimized zwitterionic hydrophilic interaction chromatography (HILIC) monolithic stationary phase. Good permeability, stability, and column efficiency were observed on the final monolithic column. Additionally, a weak electrostatic interaction for charged analytes was confirmed in analysis of six benzoic acids by studying the influence of mobile phase pH and salt concentration on their retention behaviors on the obtained zwitterionic HILIC monolithic column. The optimized zwitterionic HILIC monolith exhibited good selectivity for a range of polar test analytes.  相似文献   

18.
Li Y  Feng Y  Chen T  Zhang H 《Journal of chromatography. A》2011,1218(35):5987-5994
An imidazoline was prepared by solvent-free microwave-assisted organic synthesis and immobilized on porous silica particles by polymerization. The resulting material was composed of both hydrophobic alkyl ester chains and hydrophilic imidazoline rings, which gave it both hydrophilic interaction and reversed-phase characteristics. The titration curve suggests that the new material has buffering capacity and acquires increasing positive charge over the pH range 9-4, and is "zwitterionic" in the upper part of this pH range. Through investigating the effect of column temperature, the water content, pH and ion strength of mobile phase on the retention time of polar compounds in highly organic eluents, it was found that the new material could be used as a hydrophilic interaction liquid chromatography (HILIC) stationary phase which involved a complex retention process consisting of partitioning, surface adsorption and electrostatic interactions. In addition, the retention behavior of aromatic compounds in different mobile phase conditions was also studied, which showed the new material mainly exhibited a partitioning mechanism in the reversed-phase liquid chromatography (RPLC) mode. The separation of six water-soluble vitamins and five aromatic compounds were achieved by using the new material in the HILIC and RPLC modes, respectively.  相似文献   

19.
Novel pH-responsive polymer-grafted silica was successfully synthesized through the radical "grafting from" polymerization on azo initiator-immobilized silica. The immobilization of azo initiator onto the silica surface was achieved by the reaction of surface amino groups with 4,4'-azobis(4-cyanovaleric acid chloride). The polymer-grafted silica was prepared by stirring suspension of the azo initiator-immobilized silica in anhydrous dioxane containing acrylic acid (AAc) and butyl acrylate (BA). The resulting polymer-grafted silica was demonstrated to be pH responsive to hydrophobic/hydrophilic property by reversed-phase liquid chromatography (RPLC) and hydrophilic interaction chromatography (HILIC). In RPLC mode, the retention of aromatic compounds decreased with the increase in the pH of mobile phase. However, the opposite result was obtained in HILIC mode; the retention of soybean isoflavones was stronger with the mobile phase at higher pH. Finally, the separations of sulfonamides and soybean isoflavones were carried out in RPLC mode and the separation of some nucleotides was achieved in HILIC mode.  相似文献   

20.
A new hydrophilic and nonionic poly(2-vinyloxazoline)-grafted silica (Sil-VOX n ) phase was synthesized and applied for the separation of nucleosides and nucleobases in hydrophilic interaction chromatography (HILIC). Polymerization and immobilization onto silica were confirmed by using characterization techniques including 1H NMR spectroscopy, elemental analysis, and diffuse reflectance infrared Fourier transform spectroscopy. The hydrophilicity or wettability of Sil-VOX n was observed by measuring the contact angle (59.9°). The chromatographic results were compared with those obtained with a conventional HILIC silica column. The Sil-VOX n phase showed much better separation of polar test analytes than the silica column, and the elution order was different. Differences in selectivity between these two columns indicate that the stationary phase cannot function merely as an inert support for a water layer into which the solutes are partitioned from the bulk mobile phase. To elucidate the interaction mechanism, the separation of dihydroxybenzene isomers was performed on both columns in normal-phase liquid chromatography. Sil-VOX n was very sensitive to the dipole moments of the positional isomers of polycyclic aromatic compounds in normal-phase liquid chromatography. The interaction mechanism for Sil-VOX n in HILIC separation is also described.
Figure
Separation of nucleosides and nucleobases with Sil-VOXn (bottom) and a commercial silica column (top). Mobile phase of acetonitrile and 20 mM ammonium acetate (9:1, v/v). Flow rate 1 ml min-1, column temperature 25 °C. The analytes were as follows 5-iodouracil (1), thymine (2), uracil (3), 4,6-diaminopyrimidine (4), uridine (5), adenosine 2 (6), cytosine (7), cytidine (8), and guanosine (9)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号