首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI-Sweep-MEKC) was directly used to test some abuse drugs in human urine, including morphine (M), codeine (C), ketamine (K) and methamphetamine (MA). First, phosphate buffer (50 mM, pH 2.5) containing 30% methanol was filled into uncoated fused silica capillary (40 cm, 50 microm I.D.), then high conductivity buffer (100 mM phosphate, 6.9 kPa for 99.9 s) was followed. Electrokinetic injection (10 kV, 500 s) was used to load samples and to enhance sensitivity. The stacking step and separation were performed at -20 kV and 200 nm using phosphate buffer (25 mM, pH 2.5) containing 20% methanol and 100 mM sodium dodecyl sulfate. Using CSEI-Sweep-MEKC, the analytes could be simultaneously analyzed and have a detection limit down to ppb level. It was unnecessary to have sample pretreatments. During method validation, calibration plots were linear (r>or=0.9982) over a range of 150-3,000 ng/mL for M and C, 250-5,000 n g/mL for MA, and 50-1,000 ng/mL for K. The limits of detection were 15 ng/mL for M and C, and 5 ng/mL for MA and K (S/N=3, sampling 500 s at 10 kV). Comparing with capillary zone electrophoresis, the results indicated that this stacking method could increase 6,000-fold sensitivity for analysis of MA. Our method was applied for analysis of 28 real urine samples. The results showed good coincidence with immunoassay and GC-MS. This method was feasible for application to detect trace levels of abused drugs in forensic analysis.  相似文献   

2.
An automated flow fluorometer designed for kinetic binding analysis was adapted to develop a solid-phase competitive fluoroimmunoassay for urinalysis of opiates. The solid phase consisted of polymer beads coated with commercial monoclonal antibodies (MAbs) raised against morphine. Fluorescein-conjugated morphine (FL-MOR) was used as the fluorescein-labeled hapten. The dissociation equilibrium constant (K D ) for the binding of FL-MOR to the anti-MOR MAb was 0.23 nM. The binding of FL-MOR to the anti-MOR MAb reached steady state within minutes and was displaced effectively by morphine and other opiates. Morphine-3-glucuronide (M3G), the major urinary metabolite of heroin and morphine, competed effectively with FL-MOR in a concentration-dependent manner for binding to the antimorphine MAb and was therefore used to construct the calibration curve. The sensitivity of the assay was 0.2 ng/mL for M3G. The assay was effective at concentrations of M3G from 0.2 to 50 ng/mL, with an IC50 of 2 ng/mL. Other opiates and heroin metabolites that showed >50% crossreactivity when present at 1 μg/mL included codeine, morphine-6-glucuronide, and oxycodone. Methadone showed very low crossreactivity (<5%), which is a benefit for testing in patients being treated for opiate addictions. The high sensitivity of the assay and the relatively high cutoff value for positive opiate tests allows very small sample volumes (e.g., in saliva or sweat) to be analyzed. A double-blind comparison using 205 clinical urine samples showed good agreement between this single-step competitive assay and a commercially performed enzyme multiplied immunoassay technique for the detection of opiates and benzoylecgonine (a metabolite of cocaine).  相似文献   

3.
A sensitive and reproducible method for the determination of morphine and the metabolites morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G) was developed. The method was validated for perfusion fluid used in microdialysis as well as for sheep and human plasma. A C18 guard column was used to desalt the samples before analytical separation on a ZIC HILIC (hydrophilic interaction chromatography) column and detection with tandem mass spectrometry (MS/MS). The mobile phases were 0.05% trifluoroacetic acid (TFA) for desalting and acetonitrile/5 mM ammonium acetate (70:30) for separation. Microdialysis samples (5 microL) were directly injected onto the system. The lower limits of quantification (LLOQ) for morphine, M3G and M6G were 0.50, 0.22 and 0.55 ng/mL, respectively, and the method was linear from LLOQ to 200 ng/mL. For plasma, a volume of 100 microL was precipitated with acetonitrile containing internal standards (deuterated morphine and metabolites). The supernatant was evaporated and reconstituted in 0.05% TFA before the desalting process. The LLOQs for sheep plasma were 2.0 and 3.1 ng/mL and the ranges were 2.0-2000 and 3.1-3100 ng/mL for morphine and M3G, respectively. For human plasma, the LLOQs were 0.78, 1.49 and 0.53 ng/mL and the ranges were 0.78-500, 1.49-1000 and 0.53-500 ng/mL for morphine, M3G and M6G, respectively.  相似文献   

4.
The present paper describes the methodological optimization and validation of capillary zone electrophoresis (CZE) for the determination of major opiates (morphine, codeine, 6-monoacetylmorphine, acetylcodeine, heroin) in hair samples by using a field-amplified sample stacking injection before the separation in a binary running buffer (0.1 M sodium phosphate, pH 2.5, with 40% ethylene glycol). The applied potential was 20 kV, at 25 degrees C. Detection was by UV absorption at the fixed wavelength of 214 nm or by recording the full spectrum between 190-400 nm, thus improving the analytical selectivity and identification power of CZE. Hair samples were liquid/liquid extracted; dried extracts, reconstituted with a low-conductivity solvent (0.1 mM phosphoric acid, with 80% 1-propanol), were injected by electromigration at 10 kV for 99 s, after a 0.5 mm plug of water. Under the described conditions, the limit of detection (with a signal-to-noise ratio of 3) in hair extracts was 100 pg/mL for codeine, 75 pg/mL for morphine and 6-monoacetylmorphine (6-MAM), 150 pg/mL for ethylmorphine, and 0.75 ng/mL for acetylcodeine and heroin. The precision of the method was validated for standards in pure solution by using internal standardization, providing for intraday and day-to-day assays, in terms of migration times, relative standard deviation (RSD) values < or = 0.2%, and in terms of peak areas, RSD values <5.71%.  相似文献   

5.
Morphine is one of the most effective agents for the control of significant pain, primarily metabolized to morphine‐3‐glucuronide (M3G) and morphine‐6‐glucuronide (M6G). While M6G is a potent opioid agonist, M3G has no opioid action and seems to have a role in side‐effects caused by morphine. In this study, a reversed‐phase high‐performance liquid chromatographic method with diode‐array and electrochemical detection was developed for the simultaneous determination of morphine, M3G and M6G in antemortem and postmortem samples (plasma, whole blood, urine, liver, kidney and brain). Morphine, glucuronides and internal standard were extracted by double solid‐phase extraction and the separation was carried out with a Waters Spherisorb® ODS2 reversed‐phase column and potassium phosphate buffer (pH = 2.2)–acetonitrile containing sodium dodecyl sulfate as the mobile phase. The method proved to be specific with good linearity for all analytes in a calibration range from 1 to 600 ng/mL and proved to be accurate and have adequate precision and recovery. Limits of detection in the studied matrices were 0.4–4.5 ng/mL for morphine, 2.7–6.1 ng/mL for M3G and 0.8–4.4 ng/mL for M6G. The proposed method can be successfully applied to quantify morphine and its metabolites in several biological samples, covering the major routes of distribution, metabolism and elimination of morphine. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
Wei F  Zhang M  Feng YQ 《Electrophoresis》2006,27(10):1939-1948
A novel poly(methacrylic acid-ethylene glycol dimethacrylate) (MAA-EGDMA) monolith microextraction method coupled with CZE was proposed for rapidly determining a mixture of opiates comprising heroin, 6-monoacetylmorphine, morphine, codeine, papaverine, and narcotine in human urine. The extraction device contained a regular plastic syringe, the poly(MAA-EGDMA) monolithic capillary tube (530 microm id x 3 cm) and a plastic pinhead, which connected the monolithic capillary tube and the syringe without leakage. In the polymer monolith microextraction, the sample solution was ejected via the monolithic capillary tube by a programmable syringe pump, followed by desorption with an aliquot of appropriate solution, which was collected into a vial for the subsequent analysis by CZE. The best separation was achieved using a buffer composed of 0.1 M disodium hydrogen phosphate (adjusted to pH 4.5 with 1 M hydrochloric acid) and 20% methanol v/v with temperature and voltage of 25 degrees C and 25 kV, respectively. By applying electrokinetic injection with field-enhanced sample stacking, detection limits of 6.6-19.5 ng/mL were achieved. Excellent method of reproducibility was found over a linear range of 80-2000 ng/mL.  相似文献   

7.
Heroin metabolites including morphine, codeine, and 6-acetylmorphine were determined by cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI–sweep-MEKC). Liquid–liquid extraction was used for urine pretreatment. An uncoated fused silica capillary (Ld = 30 cm, 50 μm ID) was filled with phosphate buffer (50 mM, pH 2.5) containing 30% methanol, then high conductivity buffer (100 mM phosphate, 41.3 kPa for 18 s) was followed. Samples were injected electrokinetically (20 kV, 300 s). The sweeping and separation were performed at −25 kV using phosphate buffer (20 mM, pH 2.5) and 80 mM sodium dodecyl sulfate. The baseline separation was done within 10 min. During method validation, the calibration curves were linear over a range of 50–500 ng/mL (r ≧ 0.994). The RSD and RE values in intra-day and inter-day assays were all below 20%, which showed good precision and accuracy. Their detection limits were 10 ng/mL (S/N = 3). The optimized method was applied to determine real urine samples from addicts. These samples were confirmed by liquid chromatography/mass spectrometry.  相似文献   

8.
An isocratic high-performance liquid chromatographic method has been developed for the determination of morphine, morphine-3-glucuronide, morphine-6-glucuronide and codeine in plasma, urine and cerebrospinal fluid. The use of an efficient solid-phase extraction procedure together with a forward optical scanning detector allows a detection limit of 500 pg/ml. The method was evaluated by examination of biological samples taken from newborn infants following the intravenous administration of morphine sulfate.  相似文献   

9.
Cheng HL  Jong YJ  Li JH  Ko WK  Wu SM 《Electrophoresis》2006,27(23):4711-4716
Direct analysis of methamphetamine, amphetamine, and p-hydroxymethamphetamine in urine was achieved by cation-selective exhaustive injection and sweeping micellar EKC. A bare fused-silica capillary (40 cm, 50 microm id) was filled with phosphate buffer (80 mM, pH 3, containing 20% ACN). Then a high-conductivity buffer (100 mM phosphate, pH 3; 6.9 kPa for 2.5 min) was injected. Samples were loaded using electrokinetic injection (10 kV, 600 s) which created long zones of cationic analytes. To enhance sensitivity by sweeping, the stacking step was performed using a phosphate buffer (50 mM, pH 3, containing 20% ACN and 100 mM SDS) at -20 kV before separation by MEKC. This method was capable of detecting the analytes at ppb levels. The calibration plots were linear (r(2) >or= 0.9948) over a range of 100-5000 ng/mL for methamphetamine, and 100-2000 ng/mL for amphetamine and p-hydroxymethamphetamine. The LODs (S/N = 3) were 20 ng/mL for methamphetamine, and 15 ng/mL for amphetamine and p-hydroxymethamphetamine. The method was applied to analysis of 14 urine samples of addicts and is suitable for screening suspected samples for forensic purposes. The results showed good agreement with fluorescence polarization immunoassay and GC-MS.  相似文献   

10.
A sensitive and specific method for the determination of morphine glucuronides in human plasma is presented. Morphine glucuronides, namely morphine-6-glucuronide (M6G) and morphine-3-glucuronide (M3G), were extracted from plasma by solid-phase extraction on C(18) cartridges at pH 9.3 and derivatized to their pentafluorobenzyl ester trimethylsilyl ether derivatives. The compounds were measured by gas chromatography/negative ion chemical ionization mass spectrometry without any further purification. Using this detection mode, a diagnostic useful fragment ion at m/z 748 was obtained at high relative abundance for both target compounds. [(2)H(3)]-labeled morphine glucuronides were used as internal standards. Calibration graphs were calculated by polynomial fit within a range of 10-1280 and 15-1920 nmol l(-1) for the 6- and 3-glucuronide, respectively. At the limit of quantitation (LOQ), the inter-assay precision was 2.21% (M3G) and 2.23% (M6G) and the GC/MS assay variability was 1.8% (M3G) and 0.9% (M6G). The accuracy at the LOQ showed deviations of +4.92% (M3G) and +1.5% (M6G). The sample recovery after solid-phase extraction was 84.7% for both M3G and M6G. The method is rugged, rapid and robust and has been applied to the batch analysis of morphine glucuronides during pharmacokinetic profiling of the drugs.  相似文献   

11.
A micellar electrokinetic chromatography method is proposed for the determination of morphine, codeine, and paclitaxel at clinical relevant levels in human serum and plasma, which are employed in the treatment of patients with cancer. Optimal conditions for the separation were investigated. A background electrolyte solutions consisting of 20 mM borate buffer adjusted to pH 8.5, sodium dodecyl sulphate 60 mM and 15% methanol, hydrodynamic injection, and 25 kV as separation voltage were used. Detection wavelength was 212 nm for morphine and codeine and 200 nm for paclitaxel. Aspects such as stability of the solutions, linearity, accuracy, precision, and robust and ruggedness were examined in order to validate the proposed method. Detection limits obtained for all the studied compounds ranged between 26 and 52 ng/mL. Before micellar electrokinetic chromatography determination, the samples were purified and enriched by means of an extraction-preconcentration step with a preconditioned C(18) cartridge. This method was applied to the analysis of serum and plasma samples from different cancer patients undergoing treatment with paclitaxel or/and codeine.  相似文献   

12.
A method for the fast analysis of morphine (M), normorphine (NM), morphine-3- and -6-glucuronides (M3G and M6G) and codeine (C) is described which has the advantages of sensitivity, speed and specificity. Dihydrocodeine and heroin can also be assayed. The method is based on extraction of the opiates from serum, plasma and cerebrospinal fluid using reversed-phase solid-phase extraction columns, followed by reversed-phase high-performance liquid chromatography with native fluorescence detection. The extraction step provides greater than 95% recovery, and the response of the detection system is linear from 0.5 to beyond 750 ng. The method allows analysis of M, NM, M3G, M6G and C. No other drugs have been found to interfere with the assay. The assay offers a quick, cheap and reliable method of specifically determining morphine and its metabolites, including the potent M6G, from a small sample volume; this will be of advantage to both clinician and basic scientist.  相似文献   

13.
This study describes an on-line stacking CE approach by sweeping with whole capillary sample filling for analyzing five anabolic androgenic steroids in urine samples. The five anabolic steroids for detection were androstenedione, testosterone, epitestosterone, boldenone, and clostebol. Anabolic androgenic steroids are abused in sport doping because they can promote muscle growth. Therefore, a sensitive detection method is imperatively required for monitoring the urine samples of athletes. In this research, an interesting and reliable stacking capillary electrophoresis method was established for analysis of anabolic steroids in urine. After liquid–liquid extraction by n-hexane, the supernatant was dried and reconstituted with 30 mM phosphate buffer (pH 5.00) and loaded into the capillary by hydrodynamic injection (10 psi, 99.9 s). The stacking and separation were simultaneously accomplished at ?20 kV in phosphate buffer (30 mM, pH 5.0) containing 100 mM sodium dodecyl sulfate and 40 % methanol. During the method validation, calibration curves were linear (r?≥?0.990) over a range of 50–1,000 ng/mL for the five analytes. In the evaluation of precision and accuracy for this method, the absolute values of the RSD and the RE in the intra-day (n?=?3) and inter-day (n?=?5) analyses were all less than 6.6 %. The limit of detection for the five analytes was 30 ng/mL (S/N?=?5, sampling 99.9 s at 10 psi). Compared with simple MECK, this stacking method possessed a 108- to 175-fold increase in sensitivity. This simple and sensitive stacking method could be used as a powerful tool for monitoring the illegal use of doping.  相似文献   

14.
A method based on the direct injection of diluted urine for the identification and quantification of morphine, morphine-3-glucuronide, morphine-6-glucuronide, codeine, codeine-6-glucuronide, ethylmorphine, ethylmorphine-6-glucuronide and 6-acetylmorphine (6AM) in human urine by electrospray ionisation liquid chromatography-tandem mass spectrometry was validated for use as a confirmation procedure in urine drug testing. Four deuterium labelled analogues were used as internal standards: morphine-3-glucuronide-D3, morphine-D3, codeine-D3 and 6AM-D3. Twenty microlitre aliquots of urine were mixed with 80 mul of the internal standard solution in autosampler vials and 10 mul was injected. The chromatographic system consisted of a 2.0 x 100 mm C18 column and the gradient elution buffers used acetonitrile and 25 mmol/l formic acid. Two product ions produced from the protonated molecular ions were monitored in the selected reaction monitoring mode. The intra- and inter-assay variability (coefficient of variation) was below 10% at higher levels for all analytes, but at the reporting limits the variation was above 20% for 6AM, morphine-3-glucuronide and codeine-6-glucuronide. Ion suppression occurred early after injection but did not affect the identification and quantification of the analytes in authentic samples. The method was further validated by comparison with a reference gas chromatographic-mass spectrometric method using authentic urine samples. The two methods agreed almost completely (99%) regarding the identified analytes, but for the quantitative results there were slightly lower levels when measuring glucuronides directly as compared to total determination after hydrolysis by gas chromatography-mass spectrometry.We conclude that the presented liquid chromatographic-tandem mass spectrometric method is robust and reliable, and suitable for use as a confirmation method in urine drug testing for opiates  相似文献   

15.
A rapid and sensitive high‐performance LC‐MS/MS method was developed and validated for the simultaneous quantification of codeine and its metabolite morphine in human plasma using donepezil as an internal standard (IS). Following a single liquid‐liquid extraction with ethyl acetate, the analytes were separated using an isocratic mobile phase on a C18 column and analyzed by MS/MS in the selected reaction monitoring mode using the respective [M+H]+ ions, mass‐to‐charge ratio (m/z) 300/165 for codeine, m/z 286/165 for morphine and m/z 380/91 for IS. The method exhibited a linear dynamic range of 0.2–100/0.5–250 ng/mL for codeine/morphine in human plasma, respectively. The lower LOQs were 0.2 and 0.5 ng/mL for codeine and its metabolite morphine using 0.5 mL of human plasma. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. A run time of 2.0 min for each sample made it possible to analyze more than 300 human plasma samples per day. The validated LC‐MS/MS method was applied to a pharmacokinetic study in which healthy Chinese volunteers each received a single oral dose of 30 mg codeine phosphate.  相似文献   

16.
One CE method was established for detecting deferoxamine (DFO) and deferiprone (DFR) in plasma. For β‐thalassemia patients, DFO and DFR are major medicines to treat the iron overload caused by blood transfusion. Field‐amplified sample injection combined with sweeping was used for sensitivity enhancement in CE. This method was performed on an uncoated fused‐silica capillary. After liquid–liquid extraction, the plasma samples were electrokinetically injected into capillary at +10 kV for 180 s. The phosphate buffer (100 mM) containing 50 mM triethanolamine was used as the BGE (pH 6.6). Separation buffer was phosphate buffer (100 mM, pH 3.0) containing 150 mM SDS. This method showed good linearity (r ≥ 0.9960). Precision and accuracy were evaluated by the results of RSD and relative error of intrabatch and interbatch analyses, and all of the absolute values were less than 6.12%. The LODs (S/N = 3) were 200 ng/mL for DFO, and 25 ng/mL for DFR. The LOQ (S/N = 10) of DFO and DFR were 600 and 75 ng/mL, respectively. This method was applied for clinical applications of five β‐thalassemia patients.  相似文献   

17.
Improvements to previously reported methods for the determination of morphine, morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G) in human plasma are described. The improved methods involve the use of a solid-phase extraction cartridge and a chromatographic system which uses paired-ion reversed-phase high-performance liquid chromatography with a radially compressed column. Only one cartridge is used to prepare each sample for chromatography and each cartridge may be used for at least fourteen 1-ml plasma samples. The recovery is greater than 85%. The improvements to the method of sample pretreatment and in the chromatographic conditions have allowed determination of morphine, M3G and M6G in human plasma down to 13.3 nmol/l (coefficient of variation = 9.3%), 108 nmol/l (6.6%) and 41 nmol/l (6.7%), respectively, using ultraviolet detection alone. It was shown that all three compounds were stable in plasma for up to 101 weeks when stored at -20 degrees C.  相似文献   

18.
Determination of melatonin (MT) (N-acetyl-5-methoxytryptamine) and related indole compounds using standard capillary electrophoresis (CE) system with UV detection was investigated. Satisfactory separations of six analytes i.e. l-tryptophan (l-TRP), 5-methoxyindoleacetic acid (5-MIAA), 6-hydroxymelatonin (6-HMT), MT, serotonin (SER) and 5-methoxytryptamine (5-MTRA) were performed employing micellar electrokinetic chromatography (MEKC). The optimal background electrolytes (BGE) used for separations were 20mM tetraborate buffer (pH 9.2) and 20mM phosphate buffer (pH 3.3) when employing techniques with normal and reverse migration of micelles, respectively. Fifty millimolar sodium dodecyl sulfate (SDS) was employed as the pseudostationary phase and voltage of +/-20kV was used throughout the investigation. On-line preconcentration techniques, stacking and sweeping, were applied in order to overcome high detection limits that are a serious drawback of CE with UV detection. A comparison of used techniques, concerning enhancement factors and limits of detection (LOD), is presented. Obtained results show that the use of stacking with reverse migrating micelles (SRMM) as one of preconcentration techniques allows obtaining the lowest estimated LODs for MT at the level of 30ng/mL with injection time of 99s at 0.5psi. Estimated LODs for other analytes in these conditions were, 21, 26 and 100ng/mL for l-TRP, 5-MIAA and 6-HMT, respectively. Signals of 5-MTRA and SER obtainable only with 10s injection allowed reaching estimated LODs of 62.5 and 130ng/mL, respectively. Analysis of spiked, diluted human serum was carried out as a preliminary application illustration of developed procedure.  相似文献   

19.
A liquid chromatographic-electrospray ionization-tandem mass spectrometric method for the quantification of the opiates morphine, codeine, and their metabolites morphine-3-beta-D-glucuronide (M-3-G), morphine-6-beta-D-glucuronide (M-6-G) and codeine-6-beta-D-glucuronide (C-6-G) in human urine has been developed and validated. Identification and quantification were based on the following transitions: 286 to 201 and 229 for morphine, 300 to 215 and 243 for codeine, 462 to 286 [corrected] for M-3-G, 462 to 286 for M-6-G, and 476 to 300 for C-6-G. Calibration by linear regression analysis utilized deuterated internal standards and a weighting factor of 1/X. The method was accurate and precise across a linear dynamic range of 25.0 to 4000.0 ng/ml. Pretreatment of urine specimens using solid phase extraction was sufficient to limit matrix suppression to less than 40% for all five analytes. The method proved to be suitable for the quantification of morphine, codeine, and their metabolites in urine specimens collected from opioid-dependent participants enrolled in a methadone maintenance program.  相似文献   

20.
A robust ultra‐performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) method for the determination of morphine‐6‐d ‐glucuronide (M6G), morphine‐3‐d ‐glucuronide (M3G) and morphine (MOR) in human plasma and urine has been developed and validated. The analytes of interest were extracted from plasma by protein precipitation. The urine sample was prepared by dilution. Both plasma and urine samples were chromatographed on an Acquity UPLC HSS T3 column using gradient elution. Detection was performed on a Xevo TQ‐S tandem mass spectrometer in multiple reaction monitoring mode using positive electrospray ionization. Matrix interferences were not observed at the retention time of the analytes and internal standard, naloxone‐D5. The lower limits of quantitation of plasma and urine were 2/0.5/0.5 and 20/4/2 ng/mL for M6G/M3G/MOR, respectively. Calibration curves were linear over the concentration ranges of 2–2000/0.5–500/0.5–500 and 20–20,000/4–4000/2–2000 ng/mL for M6G/M3G/MOR in plasma and urine samples, respectively. The precision was <7.14% and the accuracy was within 85–115%. Furthermore, stability of the analytes at various conditions, dilution integrity, extraction recovery and matrix effect were assessed. Finally, this quantitative method was successfully applied to the pharmacokinetic study of M6G injection in Chinese noncancer pain patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号