首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this article, we report the design of a microchip based hydraulic pump that employs a sodium silicate derived sol–gel structure for generating pressure-driven flow within a microfluidic network. The reported sol–gel structure was fabricated in a chosen location of our device by selectively retaining sodium silicate solution within a sub-micrometer deep segment via capillary forces, and then providing the precursor material appropriate thermal treatment. It was shown that while the molecular weight cut-off for these membranes is at least an order of magnitude smaller than their photo-polymerized counterparts, their electrical conductance is significant. Moreover, unlike their polymeric counterparts these structures were found to be capable of blocking electroosmotic flow, thereby generating a pressure-gradient around their interface with an open microchannel upon application of an electric field across the microchannel–membrane junction. In this work, a fraction of the resulting hydrodynamic flow was successfully guided to an electric field-free analysis channel to implement a pressure-driven assay. Our experiments show that the pressure-driven velocity produced in the analysis channel of our device varied linearly with the voltage applied across the sol–gel membrane and was nearly independent of the cross-sectional dimensions of the membrane and the microfluidic channels. With our current design pressure-driven velocities up to 1.7 mm/s were generated for an applied voltage of 2 kV, which easily covers the range of flow speeds that can minimize the plate height in most microfluidic separations. Finally, the functionality of our device was demonstrated by implementing a reverse phase chromatographic separation in the analysis channel of our device using the pressure-driven flow generated on-chip.  相似文献   

2.
Johann R  Renaud P 《Electrophoresis》2004,25(21-22):3720-3729
Selective transport and sorting of particles in microfluidic devices by electroosmosis is complicated due to superposition of uncontrolled hydrodynamic pressure contributions on the electroosmotic force. In this paper, we present a microfluidic concept for the reliable and simple separation and sorting of particles in a microchip by electroosmosis combined with pressure-driven flow. The presented device allows fluid quantities to be switched and particles to be sorted within a channel manifold using only a single power supply with fixed voltage and an electric switch. Consequently, chip operation and fluid switching procedure are greatly simplified compared to a situation, in which several independent power sources are used for flow balancing, as is the common procedure. With the triple-T channel design presented, backpressure flow disturbing the electrokinetic fluid and particle separation process is eliminated by introducing controlled opposed hydrodynamic flow of buffer from side channels. This pressure-driven flow is generated on-chip by setting up differences in the reservoir pressures in a defined manner. A detailed flow analysis based on the equivalence of fluid flow and electric current is performed and the conditions for reliable chip function are worked out.  相似文献   

3.
An interface design is presented that facilitates automated sample introduction into an electrokinetic microchip, without perturbing the liquids within the microfluidic device. The design utilizes an interface flow channel with a volume flow resistance that is 0.54-4.1 x 10(6) times lower than the volume flow resistance of the electrokinetic fluid manifold used for mixing, reaction, separation, and analysis. A channel, 300 microm deep, 1 mm wide and 15-20 mm long, was etched in glass substrates to create the sample introduction channel (SIC) for a manifold of electrokinetic flow channels in the range of 10-13 microm depth and 36-275 microm width. Volume flow rates of up to 1 mL/min were pumped through the SIC without perturbing the solutions within the electrokinetic channel manifold. Calculations support this observation, suggesting a leakage flow to electroosmotic flow ratio of 0.1:1% in the electrokinetic channels, arising from 66-700 microL/min pressure-driven flow rates in the SIC. Peak heights for capillary electrophoresis separations in the electrokinetic flow manifold showed no dependence on whether the SIC pump was on or off. On-chip mixing, reaction and separation of anti-ovalbumin and ovalbumin could be performed with good quantitative results, independent of the SIC pump operation. Reproducibility of injection performance, estimated from peak height variations, ranged from 1.5-4%, depending upon the device design and the sample composition.  相似文献   

4.
Oh KW  Lee K  Ahn B  Furlani EP 《Lab on a chip》2012,12(3):515-545
This article reviews the application of electric circuit methods for the analysis of pressure-driven microfluidic networks with an emphasis on concentration- and flow-dependent systems. The application of circuit methods to microfluidics is based on the analogous behaviour of hydraulic and electric circuits with correlations of pressure to voltage, volumetric flow rate to current, and hydraulic to electric resistance. Circuit analysis enables rapid predictions of pressure-driven laminar flow in microchannels and is very useful for designing complex microfluidic networks in advance of fabrication. This article provides a comprehensive overview of the physics of pressure-driven laminar flow, the formal analogy between electric and hydraulic circuits, applications of circuit theory to microfluidic network-based devices, recent development and applications of concentration- and flow-dependent microfluidic networks, and promising future applications. The lab-on-a-chip (LOC) and microfluidics community will gain insightful ideas and practical design strategies for developing unique microfluidic network-based devices to address a broad range of biological, chemical, pharmaceutical, and other scientific and technical challenges.  相似文献   

5.
An electric field-free electroosmotic pump has been constructed and its pumping rate has been measured under various experimental conditions. The key component of the pump is an ion-exchange membrane grounding joint that serves two major functions: (i) to maintain fluid continuity between pump channels and microfluidic conduit and (ii) to ground the solution in the microfluidic channel at the joint through an external electrode, and hence to decouple the electric field applied to the pump channels from the rest of the microfluidic system. A theoretical model has been developed to calculate the pumping rates and its validity has been demonstrated.  相似文献   

6.
We propose a low-cost and versatile method to measure flow rate in microfluidic channels under pressure-driven flows, thereby providing a simple characterization of the hydrodynamic permeability of the system. The technique is inspired by the current monitoring method usually employed to characterize electro-osmotic flows, and makes use of the measurement of the time-dependent electric resistance inside the channel associated with a moving salt front. We have successfully tested the method in a micrometer-size channel, as well as in a complex microfluidic channel with a varying cross-section, demonstrating its ability in detecting internal shape variations.  相似文献   

7.
Inertial microfluidics has attracted significant attentions in last decade due to its superior advantages of high throughput, label- and external field-free operation, simplicity, and low cost. A wide variety of channel geometry designs were demonstrated for focusing, concentrating, isolating, or separating of various bioparticles such as blood components, circulating tumor cells, bacteria, and microalgae. In this review, we first briefly introduce the physics of inertial migration and Dean flow for allowing the readers with diverse backgrounds to have a better understanding of the fundamental mechanisms of inertial microfluidics. Then, we present a comprehensive review of the recent advances and applications of inertial microfluidic devices according to different channel geometries ranging from straight channels, curved channels to contraction-expansion-array channels. Finally, the challenges and future perspective of inertial microfluidics are discussed. Owing to its superior benefit for particle manipulation, the inertial microfluidics will play a more important role in biology and medicine applications.  相似文献   

8.
Hybrid microfluidic/nanofluidic devices offer unique capabilities for manipulating and analyzing minute volumes of expensive or hard-to-obtain samples. Here, multilayer poly-(methyl methacrylate) microchips, with multiple spatially isolated microfluidic channels interconnected by nanocapillary array membranes (NCAMs), are fabricated using an adhesive contact printing process. The NCAMs, positioned between the microfluidic channel layers, add functionality to the inter-microchannel fluid transfer unit operation. They do so because the transport of specific analytes through the NCAM can be controlled by adjusting the ionic strength, the polarity of the applied bias, the surface charge density, and the pore size. A simplified, floating injection technique for NCAM-coupled nanofluidic devices is described and compared with conventional biased injection. In the floating injection approach, a voltage is applied across the injection channel and the slight electric field extension at the cross-section is used to transfer analytes through the nanopores to the separation channel. Floating injection excels in plug reproducibility, separation resolution, and operation simplicity, although it decreases assay throughput relative to biased injection. Floating injection can avoid the uneven distribution of analytes in the microfluidic channel that sometimes results from biased injection because of the volume mismatch between NCAM nanopore transport capacity and the supply of fluid. Moreover, the pressure-driven flow caused by the mismatch of the EOFs in the microfluidic channels connected by an NCAM must be considered when using NCAMs with pore diameters below 50 nm.  相似文献   

9.
Herein, we extend our previous approach concerning the reconstruction of profiles of pressure-driven hydrodynamic flow in microfluidic channels based on current measurements at band electrode(s) [see the preceding paper ChemPhysChem 2005, 6, 1581]. We address the central issue of optimization of geometrical parameters describing the electrode(s) assembly (a single band and two bands working in generator-collector mode) within the channel flow cell to enhance the speed and precision of the flow profile reconstruction method.  相似文献   

10.
A new scheme has been described for continuous particle separation using EOF in microfluidic devices. We have previously reported a method for particle separation, called "pinched flow fractionation (PFF)", in which size-dependent and continuous particle separation can be achieved by introducing pressure-driven flows with and without particles into a pinched microchannel. In this study, EOF was employed to transport fluid flows inside a microchannel. By controlling the applied voltage to electrodes inserted in each inlet/outlet port, the flow rates from both inlets, and flow rates distributed to each outlet could be accurately tuned, thus enabling more effective separation compared to the pressure-driven scheme. In the experiment, the particle behaviors were compared between EOF and pressure-driven flow schemes. In addition, micrometer- and submicrometer-sized particles were accurately separated and individually collected using a microchannel with multiple outlet branch channels, demonstrating the high efficiency of the presented scheme.  相似文献   

11.
A survey is made of the different factors contributing to the kinetic performance of open-tubular separation channels. Being representative for most of the channels used in microfluidic devices, the main focus is on channels with a rectangular format. Kinetic plots of t(0)/N(2 )versus N are established to allow for a visual selection of the ideal channel format and dimensions. These plots for example show that in the pressure-driven mode a channel with a flat-rectangular crosssection (top and bottom wall covered by a retentive layer) can always yield slightly faster (some 15%) separations than a cylindrical capillary, provided the channel depth is optimized. If the channel depth is fixed, the optimal w/d-ratio depends on the required plate number. In electrically driven flows, the situation is reversed and rectangular channels with a small width are to be preferred, and the cylindrical capillary format becomes the best format.  相似文献   

12.
Expressions are developed and presented that could be used to determine the film mass transfer coefficient of a solute in electroosmotic flows. In contrast to pressure-driven flows at low Reynolds numbers where the film mass transfer coefficient is independent of the linear characteristic dimension of the channel for flow, in electroosmotically driven flows at low Reynolds numbers the film mass transfer coefficient is shown to be a function of the ratio R/lambda, where R is the channel radius and lambda is the Debye length. This result implies that for electroosmotically driven flows in a packed bed or porous monolith with channels for flow having similar geometry but different sizes, the film mass transfer coefficient would vary with the size of the interstitial channels for bulk flow while in pressure-driven flows the film mass transfer coefficient would be the same for all interstitial channels. From the expressions presented in this work, one can show that for the same volumetric flow rate the film mass transfer coefficient of electroosmotically driven flows is proportional to that for pressure-driven flows. Copyright 2000 Academic Press.  相似文献   

13.
Pruim  Peter  Schoenmakers  Peter J.  Kok  Wim Th. 《Chromatographia》2012,75(21):1225-1234

An overview of the literature regarding the most recent and innovative developments in microfluidic devices for pressure-driven chromatographic separations is given, with a focus on proteomics and metabolomics applications. The applications can be considered as the main driving force for the developments in this research field, since they put high demands on the analytical technology such as for throughput, efficiency, and sensitivity and for the possibilities to interface with mass spectrometry. The developments are evaluated based on the feasibility for use in work flows for the analysis of biologically relevant samples. The literature up to the first half of 2011 is covered. Electrophoretic separations are not within the scope of this review. Several strategies have been described to obtain a retentive phase in microfluidic channels. Open channels with the stationary phase bound to the walls appear to be relatively easy to make. However, the retention in such channels is generally very low for separations of relevant samples. Microfabrication of perfectly ordered topographic structures is the most innovative of the methods discussed for the creation of stationary phases in narrow channels. Several groups work on the improvement of the surface-to-volume ratio in such channels, using different methods, and the developments towards real applications are promising. Channels packed with spherical particles and in situ polymerized monoliths for pressure-driven separations are the most frequently applied. Microfluidic devices with an integrated injection system, a (packed) separation column and a spray tip for coupling to a mass spectrometer are already commercially available, and used in practice in proteomics and metabolomics. Finally, the inherent advantages of microfluidic devices for multidimensional separations have been shown in practice in a number of studies. In these studies, pressure-driven chromatography is coupled (in series or multiplexed) to an electrophoretic separation method. The high peak capacity of such 2-dimensional separations has been shown.

  相似文献   

14.
Investigating microfluidic flow profiles is of interest in the microfluidics field for the determination of various characteristics of a lab-on-a-chip system. Microparticle tracking velocimetry uses computational methods upon recording video footage of microfluidic flow to ultimately visualize motion within a microfluidic system across all frames of a video. Current methods are computationally expensive or require extensive instrumentation. A computational method suited to microparticle tracking applications is the robust Kanade–Lucas–Tomasi (KLT) feature-tracking algorithm. This work explores a microparticle tracking velocimetry program using the KLT feature-tracking algorithm. The developed program is demonstrated using pressure-driven and EOF and compared with the respective mathematical fluid flow models. An electrostatics analysis of EOF conditions is performed in the development of the mathematical using a Poisson's Equation solver. This analysis is used to quantify the zeta potential of the electroosmotic system. Overall, the KLT feature-tracking algorithm presented in this work proved to be highly reliable and computationally efficient for investigations of pressure-driven and EOF in a microfluidic system.  相似文献   

15.
Wen Zeng  Hai Fu 《Electrophoresis》2020,41(10-11):852-859
The pressure-driven device is designed and the flow rates of the microfluidic systems can be supplied by the pressure-driven flows, which can significantly reduce the flow-rate fluctuations coming from the pump source. For pressure-driven flows, the flow rates of the fluids can be predicted by measuring the pressure drop along a polytetrafluoroethylene (PTFE) tubing. Especially, by varying the geometrical parameters of the PTFE tubing, the predicted flow rates of the fluids are compared with the experimental measurements, and the testing precision of the pressure-driven flows can be obtained. Meanwhile, the dynamic characteristics of the open-loop and closed-loop control pressure-driven device are comparatively studied. Particularly, a proportional and integral (PI) controller is integrated with the closed-loop control pressure-driven device, and the effects of the parameters of the PI controller on the dynamic characteristics of the pressure-driven devices are mainly discussed. Most importantly, by improving the dynamic characteristics of the pressure-driven devices, precise measurement and control of the pressure-driven flows can be achieved for microfluidic systems.  相似文献   

16.
Yoon SK  Fichtl GW  Kenis PJ 《Lab on a chip》2006,6(12):1516-1524
In this paper, we describe three methods to improve the performance of pressure-driven laminar flow-based microreactors by manipulating reaction-depletion boundary layers to overcome mass transfer limitations at reactive surfaces on the walls, such as electrodes. The transport rate of the reactants to the reactive surfaces is enhanced by (i) removing the depleted zone through multiple periodically-placed outlets; (ii) adding fresh reactants through multiple periodically-placed inlets along the reactive surface; or (iii) producing a spiraling, transverse flow through the integration of herringbone ridges along the channel walls. For approaches (i) and (ii), the network of microfluidic channels needs to be designed such that under the operating conditions used the right amount of boundary layer at each outlet or inlet is removed or replenished, respectively. Here, we report a set of design rules, derived with the help of a fluidic resistance circuit model, to aid in the design of appropriate microfluidic networks. Also, the actual enhancement of the performance of the electrochemical microreactor, i.e. chemical conversion efficiency, using multiple inlets, multiple outlets, or herringbone ridges is reported.  相似文献   

17.
Recent advance in liquid crystal (LqC) based immunoassays enables label-free detection of antibody, but manual preparation of LqC cells and injection of LqC are required. In this work, we developed a new format of LqC-based immunoassay which is hosted in a microfluidic device. In this format, the orientations of LqC are strongly influenced by four channel walls surrounding the LqC. When the aspect ratio (depth/width) of the channel is smaller than 0.38, LqC orients homeotropically inside the microchannel and appears dark. After antigens bind to immobilized antibodies on the channel walls, a shift of the LqC appearance from dark to bright (due to the disruption of LqC orientation) can be visualized directly. To streamline the immunoassay process, a tubing cartridge loaded with a sample solution, washing buffers and a plug of LqC is connected to the microfluidic device. By using pressure-driven flow, the cartridge allows antigen/antibody binding, washing and optical detection to be accomplished in a sequential order. We demonstrate that this microfluidic immunoassay is able to detect anti-rabbit IgG with a naked-eye detection limit down to 1 μg mL−1. This new format of immunoassay provides a simple and robust approach to perform LqC-based label-free immunodetection in microfluidic devices.  相似文献   

18.
The manipulation of living biological cells in microfluidic channels by a combination of negative dielectrophoretic barriers and pressure-driven flows is widely employed in lab-on-a-chip systems. However, electric fields in conducting media induce Joule heating. This study investigates if the local temperatures reached under typical experimental conditions in miniaturized systems cause a potential risk for hyperthermic stress or cell damage. Two methods of optical in situ temperature detection have been tested and compared: (i) the exposure of the thermo-dependent fluorescent dye Rhodamine B to heat sources situated in microfluidic channels, and (ii) the use of thermoprecipitating N-alkyl-substituted acrylamide polymers as temperature threshold probes. Two-dimensional images of temperature distributions in the vicinity of active negative dielectrophoresis (nDEP)-barriers have been obtained and local temperature variations of more than 20 degrees C have been observed at the electrode edges. Heat propagation via both buffer and channel walls lead to significant temperature increases within a perimeter of 100 microm and more. These data indicate that power dissipation has to be taken into account when experiments at physiological temperatures are planned.  相似文献   

19.
There are only a few examples in which beads are employed for heterogeneous assays on microfluidic devices, because of the difficulties associated with packing and handling these in etched microstructures. This contribution describes a microfluidic device that allows the capture, preconcentration, and controlled manipulation of small beads (<6 microm) in etched microchannels using fluid flows only. The chips feature planar diverging and converging channel elements connected by a narrow microchannel. Creation of bi-directional liquid movement by opposing electro-osmotic and pressure-driven flows can lead to the generation of controlled recirculating flow at these elements. Small polymer beads can actually be captured in the controlled rotating flow patterns. The clusters of freely moving beads that result can be perfused sequentially with different solutions. A preliminary binding curve was determined for the reaction of streptavidin-coated beads and fluorescein-labelled biotin, demonstrating the potential of this bead-handling approach for bioanalysis.  相似文献   

20.
SC Lin  PW Yen  CC Peng  YC Tung 《Lab on a chip》2012,12(17):3135-3141
Flow cytometry is a technique capable of optically characterizing biological particles in a high-throughput manner. In flow cytometry, three dimensional (3D) hydrodynamic focusing is critical for accurate and consistent measurements. Due to the advantages of microfluidic techniques, a number of microfluidic flow cytometers with 3D hydrodynamic focusing have been developed in recent decades. However, the existing devices consist of multiple layers of microfluidic channels and tedious fluidic interconnections. As a result, these devices often require complicated fabrication and professional operation. Consequently, the development of a robust and reliable microfluidic flow cytometer for practical biological applications is desired. This paper develops a microfluidic device with a single channel layer and single sheath-flow inlet capable of achieving 3D hydrodynamic focusing for flow cytometry. The sheath-flow stream is introduced perpendicular to the microfluidic channel to encircle the sample flow. In this paper, the flow fields are simulated using a computational fluidic dynamic (CFD) software, and the results show that the 3D hydrodynamic focusing can be successfully formed in the designed microfluidic device under proper flow conditions. The developed device is further characterized experimentally. First, confocal microscopy is exploited to investigate the flow fields. The resultant Z-stack confocal images show the cross-sectional view of 3D hydrodynamic with flow conditions that agree with the simulated ones. Furthermore, the flow cytometric detections of fluorescence beads are performed using the developed device with various flow rate combinations. The measurement results demonstrate that the device can achieve great detection performances, which are comparable to the conventional flow cytometer. In addition, the enumeration of fluorescence-labelled cells is also performed to show its practicality for biological applications. Consequently, the microfluidic flow cytometer developed in this paper provides a practical platform that can be used for routine analysis in biological laboratories. Additionally, the 3D hydrodynamic focusing channel design can also be applied to various applications that can advance the lab on a chip research.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏