首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel amperometric biosensor utilizing two enzymes, glucose oxidase (GOD) and horseradish peroxidase (HRP), was developed for the cathodic detection of glucose. The glucose biosensor was constructed by electrochemical formation of a polypyrrole (PPy) membrane in the presence of GOD on the surface of a HRP-modified sol-gel derived-mediated ceramic carbon electrode. Ferrocenecarboxylic acid (FCA) was used as mediator to transfer electron between enzyme and electrode. In the hetero-bilayer configuration of electrode, all enzymes were well immobilized in electrode matrices and showed favorable enzymatic activities. The amperometric detection of glucose was carried out at +0.16 V (versus saturated calomel reference electrode (SCE)) in 0.1 M phosphate buffer solution (pH 6.9) with a linear response range between 8.0×10−5 and 1.3×10−3 M glucose. The biosensor showed a good suppression of interference in the amperometric detection.  相似文献   

2.
The electrocatalytic oxidation of glucose was investigated on a nickel-basedchemically modified electrode (Ni(II)-curcumin) prepared by electropolymerization of Ni-curcumin complex (curcumin=1,7-bis[4-hydroxy-3-methoxyphenyl]-1,6-heptadiene-3,5-dione) in alkaline solution. Reaction kinetic and mechanism were investigated by using cyclic voltammetry (CV) and chronoamperometry (CA) techniques and steady-state polarization measurements. Cyclic voltammetry studies indicated that in the presence of glucose the anodic peak current of surface redox mediator was increased, followed by decrease in the corresponding cathodic current. This indicates that glucose was oxidized at the surface of this modified electrode. The results were explained based on the concept of electrocatalytic reactions that occur in this chemically modified electrode. The diffusion coefficient of glucose and the rate constant of the catalytic oxidation of glucose were found to be 6.7×10−6 cm2 s−1 and 6.5×103 M−1 s−1, respectively. It has shown that by using the Ni-curcumin modified electrode, glucose can be determined with good response and low detection limit.  相似文献   

3.
Calixarenes and their derivatives may be a promising material for enzyme immobilization owing to their particular configuration, unique molecule recognition function and aggregation properties. In this paper, p-tert-butylthiacalix[4]arene tetra-amine (TC4TA) was first used as enzyme immobilization material. This attractive material was exploited for the mild immobilization of glucose oxidase (GOD) to develop glucose amperometric biosensor. GOD was strongly adsorbed on the TC4TA modified electrode to form TC4TA/GOD composite membrane. The adsorption mechanism was driven from the covalent bond between amino-group of TC4TA and carboxyl group of GOD and molecule recognition function of TC4TA. Amperometric detection of glucose was evaluated by holding the modified electrode at 0.60 V (versus SCE) to oxidize the hydrogen peroxide generated by the enzymatic reaction. The sensor (TC4TA/GOD) showed a relative fast response (response time was about 5 s), low detection limit (20 μM, S/N = 3), and high sensitivity (ca. 10.2 mA M−1 cm−2) with a linear range of 0.08–10 mM of glucose, as well as a good operational and storage stability. In addition, optimization of the biosensor construction, the effects of the applied potential as well as common interfering compounds on the amperometric response of the sensor were investigated and discussed herein.  相似文献   

4.
Glucose oxidase(GOD) was encapsulated in the Graphene/Nafion film modified glassy carbon electrode(GCE) and used as an ECL sensor for glucose. The GOD retains its bioactivity after being immobilized into the composite film. The sensor gives a linear response for glucose in the range of 2.0×10?6–1.0×10?4 mol/L with a detection limit of 1.0×10?6 mol/L. The sensor showed good stability, the RSD for continuous scanning for 5.0×10?5 mol/L glucose was 4.21 % (n=5). After being stored in 0.05 mol/L pH 7.4 PBS in 4 °C for two weeks, the modified electrode maintains 80 % of its initial activity. The glucose sensor provides new opportunity for clinical diagnosis applications.  相似文献   

5.
A sensitive amperometric glucose biosensor based on platinum nanoparticles (PtNPs) combined aligned carbon nanotubes (ACNTs) electrode was investigated. PtNPs which can enhance the electrocatalytic activity of the electrode for electrooxidating hydrogen peroxide by enzymatic reaction were electrocrystallized on 4‐aminobenzene monolayer‐grafted ACNTs electrode by potential‐step method. These PtNPs combined ACNTs' (PtNPs/ACNTs) surfaces were characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The highly dispersed PtNPs on ACNTs can be obtained. The enzyme electrode exhibits excellent response performance to glucose with linear range from 1×10?5–7×10?3 mol L?1 and fast response time within 5 s. Furthermore, this glucose biosensor also has good reproducibility. It is demonstrated that the PtNPs/ACNTs electrode with high electrocatalytic activity is a suitable basic electrode for preparing enzyme electrodes.  相似文献   

6.
基于纳米金和硫堇固定酶的过氧化氢生物传感器   总被引:7,自引:0,他引:7  
在铂电极上自组装一层纳米金(GNs), 构建负电荷的界面, 然后通过金-硫、金-氮共价键合作用和静电吸附作用自组装一层阳离子电子媒介体硫堇(Thio). 再以同样的作用自组装一层GNs和辣根过氧化酶(HRP)的混合物, 最后在电极最外层滴加一层疏水性聚合物壳聚糖(Chit), 由此制备了一种新型的过氧化氢生物传感器. 研究了工作电位、检测底液pH、温度对响应电流的影响, 以及GNs和HRP之间的相互作用, 探讨了传感器的表面形态、交流阻抗、重现性和稳定性. 该传感器的酶催化反应活化能为12.4 kJ/mol, 表观米氏常数为6.5×10-4 mo/L, 在优化的实验条件下, 所研制的传感器对H2O2的线性范围为5.6×10-5~2.6×10-3 mol/L, 检出限为1.5×10-5 mol/L. 应用此方法制备了HRP和葡萄糖氧化酶(GOD)双酶体系葡萄糖生物传感器, 并应用于实验样品葡萄糖含量的测定.  相似文献   

7.
《Electroanalysis》2005,17(19):1780-1788
The amperometric biosensing of aromatic amines using a composite glucose oxidase (GOD)‐peroxidase (HRP) biosensor in reversed micelles is reported. Rigid composite pellets of graphite and Teflon, in which GOD and HRP were coimmobilized by simple physical inclusion, were employed for the biosensor design. This design allows the in situ generation of the H2O2 needed for the enzyme reaction with the aromatic amines, thus preventing the negative effect that the presence of a high H2O2 concentration in solution has on HRP activity. The H2O2 in situ generation is performed by oxidation of glucose catalyzed by GOD. The effect of the composition of the reversed micelles, i.e., the nature of the organic solvent used as the continuous phase, the nature and concentration of the surfactant used as emulsifying agent, the aqueous 0.05 mol L?1 phosphate buffer percentage used as the dispersed phase, and the glucose concentration in the aqueous phase, on the biosensor response was evaluated. Reversed micelles formed with ethyl acetate, a 5% of phosphate buffer (pH 7.0) containing 3.0×10?3 mol L?1 glucose, and 0.1 mol L?1 AOT (sodium dioctylsulfosuccinate), were selected as working medium. Well‐defined and reproducible amperometric signals at 0.00 V were obtained for p‐phenylenediamine, 2‐aminophenol, o‐phenylenediamine, m‐phenylenediamine, 1‐naphthylamine, o‐toluidine and aniline. The useful lifetime of one single biosensor was of 60 days. The trend in sensitivity observed for the aromatic amines is discussed considering the effect of their structure on the stabilization of the radicals formed in the enzyme reaction which are electrochemically reduced. The behavior of the composite bienzyme electrode was also evaluated in a FI (flow injection) system using reversed micelles as the carrier. The suitability of the composite bienzyme electrode for the analysis of real samples was demonstrated by determining aniline in spiked carrots.  相似文献   

8.
An amperometric glucose biosensor was successfully developed by electrochemical polymerization of p-chlorophenol (4-CP) at a Pt electrode in the presence of glucose oxidase. The amperometric response of this biosensor to hydrogen peroxide, formed as the product of enzymatic reaction, was measured at a potential of 0.6 V (vs. SCE) in phosphate buffer solution. The performances of sensors, prepared at different monomer concentrations and polymerization potentials, were investigated in detail. The biosensor prepared under optimal conditions had a linear response to glucose ranging from 2.5 × 10–4 to 1.5 × 10–2 mol L–1 with a correlation coefficient of 0.997 and a response time of less than 2 s. Substrate selectivity of the polymer-based enzyme electrode was tested for coexisting interferents such as uric acid and ascorbic acid, and no discernible response was observed. After 90 days, the response of the biosensor remained almost unchanged, indicating very good stability.  相似文献   

9.
A novel amperometric sensor for uric acid based on ordered mesoporous carbon modified pyrolytic graphite electrode was developed. Uric acid oxidation was easily catalyzed by this electrode in a phosphate buffer solution at pH 7.0, with an anodic potential decrease about 140 mV compared to bare pyrolytic graphite electrode. The uric acid level was determined by the amperometric method, at a constant potential of 0.31 mV, the catalytic current of uric acid vs. its concentration showed a good linearity in the range of 1.0 × 10−6−1.0 × 10−4 mol L−1, with a correlation coefficient of 0.999. The detection limit was 4.0 × 10−7 mol L−1. The proposed method could be effectively used for uric acid amperometric sensing in human urine.  相似文献   

10.
A novel nanocrystalline TiO2 (nano-TiO2) and Nafion composite film modified glassy carbon electrode has been developed for the determination of nitric oxide (NO) radical in an aqueous solution. This modified electrode can be employed as a NO sensor with a low detection limit, fast response, high sensitivity and selectivity. Two apparent anodic peaks were observed at 0.67 and 0.95 V at the nano-TiO2 modified glassy carbon electrode by differential pulse voltammetry (DPV). After further modification with a thin film of Nafion, which was capable of preventing some anionic interference such as nitrite and ascorbic acid, only one peak appeared and the peak current enhanced greatly. The chronocoulometric experimental results showed NO was oxidized by one-electron transfer reaction at the composite film modified electrode. The amperometric responses increased linearly with the concentrations of NO ranging from 3.6×10−7 mol/L to 5.4×10−5 mol/L. The detection limit was estimated to be 5.4×10−8 mol/L. In this sensor system, the modification film provides complete selectivity for NO over nitrite anions (NO2).  相似文献   

11.
An amperometric sensor for the determination of indole-3-acetic acid (IAA) based on the CeCl3-DHP film modified gold electrode was developed. CeCl3 was dissolved into water in the presence of dihexadecyl hydrogen phosphate (DHP). The IAA sensor was prepared via evaporating solvent of the CeCl3-DHP dispersion on the gold electrode surface. The amperometric response of IAA on the CeCl3-DHP film modified gold electrode was investigated. The experimental results indicate that the passivation of the electrode due to the adsorption of the oxidation product of IAA decreases significantly at the CeCl3-DHP film modified gold electrode, in contrast to that at the bare and the DHP modified gold electrode. The experimental parameters were optimized and an electrochemical method for the determination of IAA was established. The oxidation peak current is linearly with the concentration of IAA from 1 × 10−7 to 2 × 10−5 mol l−1 and the detection limit is 3 × 10−8 mol l−1. The relative standard deviation of eight measurements is 3.2% for 5 × 10−7 mol l−1 IAA. The IAA in plant leaves were extracted and determined by the IAA sensor.  相似文献   

12.
A simple and new reagentless phenolic compound biosensor was constructed with tyrosinase immobilized in the gelatine matrix cross-linked with formaldehyde. The morphologies of gelatine and gelatine/tryosinase were characterized by SEM. The tyrosinase retains its bioactivity when being immobilized by the gelatine film. Phenolic compounds were determined by the direct reduction of biocatalytically liberated quinone at -0.1 V vs SCE. The process parameters for the fabrication of the enzyme electrode were studied. Optimization of the experimental parameters has been performed with regard to pH, operating potential, temperature and storage stability. This biosensor exhibits a fast amperometric response to phenolic compounds. The linear range for catechol, phenol, and p-Cresol determination was from 5×10−8 to 1.4×10−4 M, 5×10−8 to 7.1×10−5 M, and 1×10−7 to 3.6×10−5 M, with a detection limit of 2.1×10−8 M, 1.5×10−8 M, and 7.1×10−8 M, respectively. The enzyme electrode retained ca.77% of its activity after 7 days of storage at 4°C in a dry state. The proposed sensor presented good repeatability, evaluated in terms of relative standard deviation (R.S.D.=8.6%) for eight different biosensors and was applied for determination in water sample. The recovery for the sample was from 99.0% to 99.8%.  相似文献   

13.
姚慧  李楠  徐景忠  朱俊杰 《中国化学》2005,23(3):275-279
本文选用生物相容性好的壳聚糖作为基体材料,使其与戊二醛交联成网状结构包埋葡萄糖氧化酶制成电化学传感器。这种壳聚糖膜不仅可以减小葡萄糖氧化酶的流失,而且能为酶提供了适宜的微环境。用红外光谱、紫外光谱及透射电镜对膜的形态和性质进行了表征。实验结果表明该传感器具有很快的响应速度,很好的稳定性和重现性,能选择性地催化葡萄糖并测定其浓度。该传感器的制备方法简单,成本低,于冰箱中放置两周信号保持在90%以上,对葡萄糖测量的线性范围为1×10-5 - 3.4×10-3mol•L-1,当信噪比为3:1时检测限为5×10-6mol•L-1。  相似文献   

14.
A novel amperometric glucose biosensor was developed by entrapping glucose oxidase (GOD) in chitosan (CS) composite doped with ferrocene monocarboxylic acid-modified magnetic core-shell Fe3O4@SiO2 nanoparticles (FMC-AFSNPs). It is shown that the obtained magnetic bio-nanoparticles attached to the surface of a carbon paste electrode (CPE) with the employment of a permanent magnet showed excellent electrochemical characteristics and at the same time acted as mediator to transfer electrons between the enzyme and the electrode. Under optimal conditions, this biosensor was able to detect glucose in the linear range from 1.0 × 10−5 to 4.0 × 10−3 M with a detection limit of 3.2 μM (S/N = 3). This immobilization approach effectively improved the stability of the electron transfer mediator and is promising for construction of biosensor and bioelectronic devices.  相似文献   

15.
A novel glucose oxidase (GOD) biosensor was fabricated with a protic ionic liquid (PIL) N-ethylimidazolium trifluoromethanesulfonate ([EIm][TfO]) as the modifier of a carbon electrode. Due to the excellent conductivity and the conformational changes of the microenvironment around the GOD, the electrochemical and biocatalytic properties of GOD immobilized on the PIL-based electrode were dramatically enhanced. A couple of well-defined redox peaks could be observed, with a formal potential of −0.476 V. The GOD biosensor presented good catalytic activity to the oxidation of glucose in oxygen-saturated phosphate buffer solutions. The cathodic peak currents of GOD decreased along with glucose concentrations. A linear response in the range 0.005–2.8 mM was obtained with a detection limit of 2.5 μM. The sensitivity and the apparent Michaelis–Menten constant (K m) were estimated to be 14.96 μA mM−1 and 1.53 μM, respectively. In addition, the biosensor remained stable over 30 days, indicating its good chemical and mechanical stability. The glucose content of several serum samples was determined by using the newly developed biosensor, and the results were in good agreement with those obtained by hospital measurements. All results suggested that PILs were a good media for supporting biocatalytic processes on the bioelectrode.  相似文献   

16.
A novel amperometric choline biosensor has been fabricated with choline oxidase (ChOx) immobilized by the sol-gel method on the surface of multi-walled carbon nanotubes (MWCNT) modified platinum electrode to improve the sensitivity and the anti-interferential property of the sensor. By analyzing the electrocatalytic activity of the modified electrode by MWCNT, it was found that MWCNT could not only improve the current response to H2O2 but also decrease the electrocatalytic potential. The effects of experimental variables such as the buffer solutions, pH and the amount of loading enzyme were investigated for the optimum analytical performance. This sensor shows sensitive determination of choline with a linear range from 5.0 × 10−6 to 1.0 × 10−4 mol/L when the operating pH and potential are 7.2 and 0.15 V, respectively. The detection limit of choline was 5.0 × 10−7 mol/L. Selectivity for choline was 9.48 μA·(mmol/L)−1. The biosensor exhibits excellent anti-interferential property and good stability, retaining 85% of its original current value even after a month. It has been applied to the determination of choline in human serum. Translated from Chinese Journal of Analytical Chemistry, 2006, 34(7): 910–914 (in Chinese)  相似文献   

17.
《Electroanalysis》2004,16(9):736-740
A new enzyme‐based amperometric biosensor for hydrogen peroxide was developed relying on the efficient immobilization of horseradish peroxidase (HRP) to a nano‐scaled particulate gold (nano‐Au) film modified glassy carbon electrode (GC). The nano‐Au film was obtained by a chitosan film which was first formed on the surface of GC. The high affinity of chitosan for nano‐Au associated with its amino groups resulted in the formation of nano‐Au film on the surface of GC. The film formed served as an intermediator to retain high efficient and stable immobilization of the enzyme. H2O2 was detected using hydroquinone as an electron mediator to transfer electrons between the electrode and HRP. The HRP immobilized on nano‐Au film maintained excellent electrocatalytical activity to the reduction of H2O2. The experimental parameters such as the operating potential of the working electrode, mediator concentration and pH of background electrolyte were optimized for best analytical performance of amperometry. The linear range of detection for H2O2 is from 6.1×10?6 to 1.8×10?3 mol L?1 with a detection limit of 6.1 μmol L?1 based on signal/noise=3. The proposed HRP enzyme sensor has the features of high sensitivity (0.25 Almol?1cm?2), fast response time (t90%≤10 s) and a long‐term stability (>1 month). As an extension, glucose oxidase (GOD) was chemically bound to HRP‐modified electrode. A GOD/HRP bienzyme‐modified electrode formed in this way can be applied to the determination of glucose with satisfactory performance.  相似文献   

18.
One of the major problems in amperometric biosensors based on detection of H2O2 produced by enzymatic reaction between oxidase enzymes and substrate is the interference of redox active compounds such as ascorbic acid (AA), dopamine (DA) and uric acid (UA). To minimize these interferences, sodium bismuthate was used for the first time as an insoluble pre‐oxidant in the flow injection (FI) amperometric glucose biosensor at a Glucose oxidase (GOx) immobilized Pt/Pd bimetallic modified pre‐anodized pencil graphite electrode (p.PGE). In this context, these interfering compounds were injected into a flow injection analysis (FIA) system using an injector which was filled with NaBiO3. Thus, these interferents were converted into their redox inactive oxidized forms before reaching the electrode in the flow cell. While glucose was not influenced by the pre‐oxidant in the injector, the huge oxidation peak currents of the interferents decreased significantly in the biosensor. FI amperometric current time curves showed that the AA, DA and UA were minimized by 96 %, 86 %, and 98 % respectively, in the presence of an equivalent concentration of interferences in a 1.0 mM glucose solution. The proposed FI amperometric glucose biosensor exhibits a wide linear range (0.01–10 mM, R2=0.9994) with a detection limit of 2.4×10?3 mM. Glucose levels in the artificial serum and two real samples were successfully determined using the fabricated FI amperometric biosensor.  相似文献   

19.
Bulk screen-printed electrodes (bSPEs) modified with zirconium phosphate (ZrP) and Meldola blue (MB) and by electrochemical deposition of a Reineckate film (bMBZrPRs-SPEs) have been constructed and used as NADH sensors. Cyclic voltammetric investigation of these bulk electrochemically modified screen-printed electrodes revealed stable catalytic activity in oxidation of the reduced form of the coenzyme nicotinamide adenine dinucleotide (NADH). Flow-injection analysis (FIA) coupled with amperometric detection confirmed the improved stability of the bMBZrPRs-SPEs (10−4 mol L−1 NADH, %RSD = 4.2, n = 90, pH 7.0). Other conditions, for example applied working potential (+50 mV relative to Ag|AgCl), flow rate (0.30 mL min−1) and pH-dependence (range 4.0–10.0) were evaluated and optimized. A glycerol biosensor, prepared by immobilizing glycerol dehydrogenase (GDH) on the working electrode area of a bMBZrPRs-SPE, was also assembled. The biosensor was most stable at pH 8.5 (%RSD = 5.6, n = 70, 0.25 mmol L−1 glycerol). The detection and quantification limits were 2.8 × 10−6 and 9.4 × 10−6 mol L−1, respectively, and the linear working range was between 1.0 × 10−5 and 1.0 × 10−4 mol L−1. To assess the effect of interferences, and recovery by the probe we analyzed samples taken during fermentation of chemically defined grape juice medium and compared the results with those obtained by HPLC.  相似文献   

20.
Nickel and nickel–copper alloy modified glassy carbon electrodes (GC/Ni and GC/NiCu) prepared by galvanostatic deposition were examined for their redox processes and electro-catalytic activities towards the oxidation of glucose in alkaline solutions. The methods of cyclic voltammetry (CV) and chronoamperometry (CA) were employed. The cyclic voltammogram of NiCu alloy demonstrates the formation of β/β crystallographic forms of the nickel oxyhydroxide under prolonged repetitive potential cycling in alkaline solution. It is also observed that the overpotential for O2 evolution increases for NiCu alloy modified electrode. In CV studies, NiCu alloy modified electrode yields significantly higher activity for glucose oxidation compared to Ni. The oxidation of glucose was concluded to be catalyzed through mediated electron transfer across the nickel hydroxide layer comprising of nickel ions of various valence states. The anodic peak currents show linear dependency with the square root of scan rate. This behavior is the characteristic of a diffusion-controlled process. Under the CA regime, the reaction followed a Cottrellian behavior, and the diffusion coefficient of glucose was found to be 1 × 10−5 cm2 s−1, in agreement with diffusion coefficient obtained in CV studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号