首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
对蛋白质在离子交换柱上选择民性和非吸附特性进行了研究。蛋白质在有机磷酸锆阳离子色谱柱上,其保留作用随流动相pH值在离子强度的增加而减小;蛋白质在强阳离子和强阴离子色谱柱上的保留作用,即是流动相中的pH值等于蛋白质的等当点,其净电荷为零。不册蛋白质仍有不同程度的保留,这主要是由于蛋白质的三维结构使电荷 密度的大小和分布的不均匀以及离子交换填料表面性质的影响。  相似文献   

2.
The surface charge of four C18 stationary phases was investigated by measuring the flow induced streaming potential, a well known electrokinetic property of charged surfaces. Three of the stationary phases (Symmetry, Gemini, and Xterra-MS) had significantly positive streaming potentials at both pH 3 and 4.5. The fourth (Zorbax-SB) appeared to be essentially neutral at pH 3 and became negative at pH 4.5. Apparent zeta potentials ranged from approximately +16 to -4 mV. The retention behavior was also investigated using chloride as model anion and glycinamide (in its protonated form) as model cation. When the retention factor (k) of glycinamide was subtracted from k of chloride anion, the resulting delta k values showed very similar trends as apparent zeta potential values, suggesting that the simple chromatographic method could be used to estimate zeta potential values, or that the zeta potential values could be useful for ranking columns according to ion exchange or exclusion behavior. The anion exchange capacity of the Symmetry and Gemini columns was also estimated, using a published chromatographic procedure, and the results suggest about 2 microEq. capacity per gram of packing.  相似文献   

3.
4.
5.
Rational methods for predicting the chromatographic behavior of human monoclonal antibodies (hMabs) in protein A affinity chromatography and cation exchange chromatography from the amino acid sequences information were proposed. We investigated the relation between the structures of 28 hMabs and their chromatographic behavior in protein A affinity chromatography and cation exchange chromatography using linear gradient elution experiments. In protein A affinity chromatography, the elution pH of the hMabs was correlated with not only the structure of the Fc region (subclass), but also that of the variable region. The elution pH of hMabs that have LYLQMNSL sequences in between the CDR2 and CDR3 regions of the heavy chain became lower among the same subclass of hMabs. In cation exchange chromatography, the peak salt concentrations IR of hMabs that have the same sequences of variable regions (or that have a structural difference in their Fc region, which puts them into a subclass) were similar. The IR values of hMabs were well correlated with the equilibrium association constant Ke, and also with the surface positive charge distribution of the variable region of the heavy chain (corrected surface net positive charge (cN) of the VH region). Based on these findings, we developed rational methods for predicting the retention behavior, which were also tested with eight additional hMabs. By considering the information on the number of binding sites associated with protein adsorption as determined experimentally, and the surface positive charge distribution from the three-dimensional structure of Mab A, we hypothesized that hMabs is separated by cation exchange chromatography as the surface positive charge distribution of the VH region is recognized.  相似文献   

6.
7.
In this work the effect of pH on membrane structure, its permeability and retention was studied. In addition, we studied whether the possible changes in the membrane properties due to the pH change are reversible. This is important for understanding the performance of nanofiltration membranes at different conditions and for the selection of cleaning processes. Moreover, the results facilitate the choice of membrane for specific applications.

Several commercial NF membranes were studied at different pH values. Their retention and flux were explained by the charge and the hydrophilic characteristics of the membranes. The filtrations were made with uncharged sugar and salt solutions.

The lower the membrane contact angle (i.e., a more hydrophilic membrane) the higher was the change in apparent zeta potential when pH was increased from 4 to 7. As a result, the retention of ions with more hydrophilic membranes changed more than hydrophobic ones when the pH was increased in the feed solution. However, some membranes retained ions well at high pH although their apparent zeta potential or hydrophilicity was relatively low. These membranes had charge inside the pores and it was not detected by streaming potential measurement along the surface or by measuring the contact angle of the surface. Thus, the apparent zeta potential of the exterior membrane surface did not sufficiently describe the ionic transport through the membrane. In addition, some membranes became significantly more open at high pH (i.e., flux increased). This was explained by the chemical nature of the polymer chains in the membrane skin layer, i.e., dissociating groups in the polymer made the surface more hydrophilic and looser when charges of the polymer chains started to repel each other at elevated pH. Generally, the retention of uncharged glucose decreased more at high pH than the salt retention. The changes in permeabilities and retentions were found to be mostly reversible in the pH range studied (very slowly in some cases, however).  相似文献   


8.
9.
Abstract

The variables that influence the retention of organic analyte anions on a macroporous, high surface area polystyrenedivinyl-benzene copolymer that is chemically modified by attaching tetraalkylammonium groups to the copolymer surface are identified and studied as a function of anion exchange capacity. A combined adsorption-anion exchange retention of the organic analyte anion is possible providing the analyte has both a hydrophophic center and an anionic charge site. As the column anion exchange capacity (0 to 173 μeq of anion exchange sites/column was studied) increases, analyte retention due to adsorption decreases and retention due to anion exchange increases. The factors influencing organic analyte anion retention by adsorption are low anion exchange capacity and mobile phase solvent composition, type of organic modifier, and pH for analytes that are weak organic acids. For anion exchange the major factors are a high anion exchange  相似文献   

10.
11.
12.
13.
The use of silica columns together with non-aqueous ionic eluents provides a stable yet flexible system for the high-performance liquid chromatographic analysis of basic drugs. At constant ionic strength, eluent pH influences retention via ionisation of surface silanols and protonation of basic analytes, pKa values indicating the pH of maximum retention. At constant pH, retention is proportional to the reciprocal of the eluent ionic strength for fully protonated analytes and quaternary ammonium compounds. The addition of water up to 10% (v/v) has little effect on retention if the protonation of the analytes is unaffected. Thus, it is likely that retention is mediated primarily via cation exchange with surface silanols. However, additional factors must play a part with compounds such as morphine which give tailing peaks at acidic or neutral eluent pHs.  相似文献   

14.
pISep is a major new advance in low ionic strength ion exchange chromatography. It enables the formation of externally controlled pH gradients over the very broad pH range from 2 to 12. The gradients can be generated on either cationic or anionic exchangers over arbitrary pH ranges wherein the stationary phases remain totally charged. Associated pISep software makes possible the calculation of either linear, nonlinear or combined, multi-step, multi-slope pH gradients. These highly reproducible pH gradients, while separating proteins and glycoproteins in the order of their electrophoretic pIs, provide superior chromatographic resolution compared to salt. This paper also presents a statistical mechanical model for protein binding to ion exchange stationary phases enhancing the electrostatic interaction theory for the general dependence of retention factor k, on both salt and pH simultaneously. It is shown that the retention factors computed from short time isocratic salt elution data of a model protein can be used to accurately predict its salt elution concentration in varying slope salt elution gradients formed at varying isocratic pH as well as the pH at which it will be eluted from an anionic exchange column by a pISep pH gradient in the absence of salt.  相似文献   

15.
A cation exchange retention mechanism concomitant with the well-known hydrophobic partition mechanism in a polymeric column has been observed and investigated. This exchange process is attributed to ionization of some acidic sites present in the polymer column at basic mobile phase pH values. Several drugs of different basicity have been chromatographed on a polymeric PLRP-S column with methanol-water and acetonitrile-water mobile phases. The cation exchange between the protonated basic drug and the buffer cations (Na+, K+ and BuNH4+) is observed at the pH range where the protonated drug and the ionized sites of the column coexist. This process produces a shift of the retention versus pH plot of the base to pH values lower than those expected from the pKa of the base as well as a maximum in the plot at basic pH values. These effects are more pronounced for acetonitrile-water mobile phases.  相似文献   

16.
The interest in understanding fundamental mechanisms underlying chromatography drastically increased over the past decades resulting in a whole variety of mostly semi-empirical models describing protein retention. Experimental data about the molecular adsorption mechanisms of lysozyme on different chromatographic ion-exchange materials were used to develop a mechanistical model for the adsorption of lysozyme onto a SP Sepharose FF surface based on molecular dynamic simulations (temperature controlled NVT simulations) with the Amber software package using a force-field based approach with a continuum solvent model. The ligand spacing of the adsorbent surface was varied between 10 and 20 Å. With a 10 Å spacing it was possible to predict the elution order of lysozyme at different pH and to confirm in silico the pH-dependent orientation of lysozyme towards the surface that was reported earlier. The energies of adsorption at different pH values were correlated with isocratic and linear gradient elution experiments and this correlation was used to predict the retention volume of ribonuclease A in the same experimental setup only based on its 3D structure properties. The study presents a strong indication for the validity of the assumption, that the ligand density of the surface is one of the key parameters with regard to the selectivity of the adsorbent, suggesting that a high ligand density leads to a specific interaction with certain binding sites on the protein surface, while at low ligand densities the net charge of the protein is more important than the actual charge distribution.  相似文献   

17.
The bentonite from Gaomiaozi county (Inner Mongolia, China) (denoted as GMZ bentonite) was characterized by X-ray powder diffraction and Fourier transform infrared spectroscopy. The effect of pH, contact time, ionic strength, humic acid (HA) and Eu(III) concentrations on Eu(III) sorption to the GMZ bentonite was studied by batch technique under ambient conditions. The sorption of Eu(III) on GMZ bentonite was strongly dependent on pH and independent of ionic strength. The sorption of Eu(III) on GMZ bentonite was mainly dominated by surface complexation rather than by ion exchange. The presence of HA enhanced Eu(III) sorption at low pH values, but decreased Eu(III) sorption at high pH values. The enhanced sorption of Eu(III) on GMZ bentonite at low pH was attributed to the strong complexation of Eu(III) with surface adsorbed HA on GMZ bentonite and the reduced sorption of Eu(III) at high pH was attributed to the formation of soluble HA–Eu complexes in aqueous solution. The strong sorption of Eu(III) on GMZ bentonite suggested that the GMZ bentonite could be used as the backfill material in nuclear waste disposal.  相似文献   

18.
19.
Described here is the impact of so-called non-EX2 exchange behavior on the accuracy of protein unfolding free energies (i.e., DeltaG u values) and m values (i.e.,-deltaDeltaG u/delta[denaturant] values) determined by an H/D exchange and mass spectrometry-based technique termed stability of unpurified proteins from rates of H/D exchange (SUPREX). Both experimental and theoretical results on a model protein, ubiquitin, reveal that reasonably accurate thermodynamic parameters for its folding reaction can be determined by SUPREX even when H/D exchange data is collected in a non-EX2 regime. Not surprisingly, the theoretical results reported here on a series of hypothetical protein systems with a wide range of biophysical properties show that the accuracy of SUPREX-derived DeltaG u and m values is compromised for many proteins when analyses are performed at high pH (e.g., pH 9) and for selected proteins with specific biophysical parameters (e.g., slow folding rates) when analyses are performed at lower pH. Of more significance is that the experimental and theoretical results reveal a means by which problems with non-EX2 exchange behavior can be detected in the SUPREX experiment without prior knowledge of the protein's biophysical properties. The results of this work also reveal that such problems with non-EX2 exchange behavior can generally be minimized if appropriate H/D exchange times are employed in the SUPREX experiment to yield SUPREX curve transition midpoints at chemical denaturant concentrations less than 2 M.  相似文献   

20.
The adsorption of Eu(III) on multiwalled carbon nanotubes (MWCNTs) as a function of pH, ionic strength and solid contents are studied by batch technique. The results indicate that the adsorption of Eu(III) on MWCNTs is strongly dependent on pH values, dependent on ionic strength at low pH values and independent of ionic strength at high pH values. Strong surface complexation and ion exchange contribute to the adsorption of Eu(III) on MWCNTs at low pH values, whereas surface complexation and surface precipitation are the main adsorption mechanism of Eu(III) on MWCNTs. The desorption of adsorbed Eu(III) from MWCNTs by adding HCl is also studied and the recycling use of MWCNTs in the removal of Eu(III) is investigated after the desorption of Eu(III) at low pH values. The results indicate that adsorbed Eu(III) can be easily desorbed from MWCNTs at low pH values, and MWCNTs can be repeatedly used to remove Eu(III) from aqueous solutions. MWCNTs are suitable material in the preconcentration and solidification of radionuclides from large volumes of aqueous solutions in nuclear waste management.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号