首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 358 毫秒
1.
A triode extraction system is designed for a dual hollow cathode ion source being developed at the Institute of Heavy Ion Physics,Peking University.Basic parameters of the plasma are selected after examining the operation principle of the ion source,then the triode extraction system is designed and optimized by using software PBGUNS (for Particle Beam GUN Simulations).The physical design of the system is given in this paper.  相似文献   

2.
This work is concerned with ion beam dynamics and compares the emittance to aberration ratios of two-and three-electrode extraction systems. The study is conducted with the aid of Version 7 of SIMION 3D ray-tracing software. The beam dependence on various parameters of the extraction systems is studied and the numerical results lead to qualitative conclusions.  相似文献   

3.
A new ion source has been designed and manufactured for the CYCLONE30 accelerator, which has a much advanced performance compared with the original. It is expected that the newly designed ion source extraction system will transport a very large percentage of the beam without deteriorating the beam optics, which is designed to deliver an H- beam at 30 keV. The accelerator assembly consists of three circular aperture electrodes made of copper. The simulation study was focused on finding parameter sets that raise the beam perveance as large as possible and which reduce the beam divergence as low as possible. Ion beams of the highest quality are extracted whenever the half-angular divergence is minimum, for which the perveance current intensity and the extraction gap have optimum values. The triode extraction system is designed and optimized by using CST software (for Particle Beam Simulations). The physical design of the extraction system is given in this paper. From the simulation results, it is concluded that it is possible to achieve this goal by decreasing the thickness of the plasma electrode, shortening the first gap, and adjusting the acceleration electrode voltage.  相似文献   

4.
A compact 14.5GHz electron cyclotron resonance (ECR) ion source for the production of slow, multiply charged ions has been constructed,with the plasma-confining magnetic field produced exclusively by permanent magnets.Microwave power of up to 175W in the frequency range from 12.75 to 14.SGHz is transmitted from ground potential via a PTFE window into the water-cooled plasma chamber which can be equipped with an aluminum liner.The waveguide coupling system serves also as biased electrode,and two remotely-controlled gas inlet valves connected via an insulating break permit plasma operation in the gas- mixing mode.A triode extraction system sustains ion acceleration voltages between 1kV and 10kV.The ECR ion source is fully computer-controlled and can be remotely operated from any desired location via Ethernet.  相似文献   

5.
A new extraction system is designed for a penning ion source DUHOCAMIS(dual hollow cathode ion source for metal ion beams)being installed at the Institute of Heavy Ion Physics,Peking University.We have analyzed theoretically the central particle trajectories in the extraction region for ions having different q/m ratios and then compared our results with the simulation results of CST(Computer Simulation Technology)software.The validity of the system is verified and some analytical formulas are obtained which will be used for the optimization of the extraction system as well as the experimental setup.  相似文献   

6.
为了提高强流ECR 离子源的引出束流品质,分别设计了1# 和2# 引出系统,利用束流引出模拟软件PBGUNS 对1# 和2# 引出系统进行了质子束流引出与传输的模拟计算,结合实际测得的发射度数据分析引出系统,发现2# 引出系统比1# 引出系统引出束流品质高。对ECR 离子源引出系统的电势等位线分布等参数引起的球差进行了简单数学推导及MATLAB 绘图,并结合1# 和2# 引出系统束流相图模拟结果证明了球差会使引出束流品质有效发射度增长,通过适当加大电极孔径可改善束流聚焦情况,得到了束流光学聚焦较好的束流引出系统设计。To improve the quality of extracted ion beam from a high current ECR ion source, 1# and 2# extraction systems were designed and tested. The PBGUNS code was used to simulate the 1# and 2# extraction systems of proton ion beam. The emittance measurement results with the two different extraction systems were compared and analyzed with the simulation, the conclusion that more high quality beam extracted from 2# system than 1# system was got. The formula derivation of ECR ion source extraction system spherical aberration and MATLAB drawing was done by the analyzing on the distribution of extraction field equipotentials, effective emittance increasing caused by spherical berration was proved by 1# and 2# extraction systems beam phase space simulation result, beam focusing would be improved if electrode hole size increasing appropriately and a general concept on good optics focusing of ion beam extraction system was proposed finally.  相似文献   

7.
G.D.Alton  H.Bilheux 《中国物理 C》2007,31(Z1):201-205
The problem of extracting space-charge-limited ion beams from spherical emission boundaries is analyzed for simple,two electrode,parallel-plate and spherical sector electrode systems by application of Langmuir-Blodgett theory with account taken for the divergent lens effect caused by the aperture in the extraction electrode.Results derived from simulation studies for the three electrode system,designed for use with the Oak Ridge National Laboratory ECR ion source,complement predictions made from elementary analytical theory with or without magnetic field in the extraction region of the source.Under minimum half- angular divergence(minimum emittance)conditions,the plasma emission boundary has an optimum curvature and the perveance,P,(i.e,current density,j and extraction gap,d),has an optimum value for a given charge- state.From these studies,we find that the optimum perveance for any electrode system can be determined from the Child-Langmuir relation for the parallel-plate electrode system multiplied by a factor,F with value 0.49≤F≤1.  相似文献   

8.
根据在表面-等离子体型负离子源中,负离子主要由转换电极表面产生这一特点,参考正离子源引出系统数值计算程序,建立了负离子源引出系统的数值计算模型和计算程序;对表面-等离子体型桶式负离子源引出系统束光学的性质进行了数值模拟。对计算结果的检验和分析表明,这个计算模型和程序反映了负离子源引出系统束光学的基本特性。  相似文献   

9.
This paper reports the simulation of an electron gun. The effects on the beam quality of some parameters on the beam quality were studied and optimal choices were identified. It gives numerical beam qualities for a common electrostatic triode gun, and the dependencies on design parameters such as electrode geometries and bias voltages to these electrodes are shown. An electron beam of diameter 5 mm with energy of 5 ke V was assumed for the simulation process. Some design parameters were identified as variable parameters in the presence of space charge.These parameters are the inclination angle of emission electrode, the applied voltage to the focusing electrode, the gap width between the emission electrode and the focusing electrode and the diameter of the focusing electrode. The triode extraction system is designed and optimized by using CST software(for Particle Beam Simulations). The physical design of the extraction system is given in this paper. From the simulation results, it is concluded that the inclination angle of the emission electrode is optimized at 22.5?, the applied voltage to the focusing electrode was optimized and found to be Vfoc =-600 V, the optimal separation distance(gap between emission electrode and focusing electrode) is 4 mm, and the optimal diameter of the emission electrode is 14 mm. Initial results for these efforts aimed at emittance improvement are also given.  相似文献   

10.
The high charge state all permanent Electron Cyclotron Resonance Ion Source(ECRIS)LAPECR2 (Lanzhou All Permanent magnet ECR ion source No.2)has been successfully put on the 320kV HV platform at IMP and also has been connected with the successive LEBT system.This source is the largest and heaviest all permanent magnet ECRIS in the world.The maximum mirror field is 1.28T(without iron plug)and the effective plasma chamber volume is as large as (?)67mm×255mm.It was designed to be operated at 14.5GHz and aimed to produce medium charge state and high charge state gaseous and also metallic ion beams.The source has already successfully delivered some intense gaseous ion beams to successive experimental terminals.This paper will give a brief overview of the basic features of this permanent magnet ECRIS.Then commissioning results of this source on the platform,the design of the extraction system together with the successive LEBT system will be presented.  相似文献   

11.
The influence of ion-beam plasma on ion extraction efficiency in a single-grid ICP ion source is researched. The single-grid ion source is considered as a system with two plasmas, ion-beam plasma and the source plasma, separated by an extraction grid. Results of experimental measurements of the potentials of the two plasmas and the ion beam current dependence on these potentials are presented. It is shown that the ion extraction efficiency depends equally on both the acceleration potential and on the potential of the ion-beam plasma. The obtained results demonstrate the key role of the ion-beam plasma in the ion source operation, which is important in technological applications and space thrusters.  相似文献   

12.
基于射频负离子源的中性束注入系统是高功率长脉冲(稳态)运行中性束注入系统的最佳选择。负离子源是中性束注入系统的核心部件,需要实现稳定的负离子束引出和加速。在负离子源的运行过程中引出负离子电流会发生变化,尤其在长脉冲、高能量运行条件下会更加明显,因此无法满足稳定运行的要求。为了实现引出束流的稳定引出,开展了束流反馈控制研究,研发了一套基于射频功率调节的束流反馈控制系统,并将束流反馈控制系统应用在射频负离子源测试平台,开展了束流反馈控制测试。测试结果表明束流反馈控制系统能够实现对束流的实时反馈调节以获得束流的稳定引出,验证了基于射频功率调节的束流反馈控制的可行性,为高功率射频负离子源的研制提供支持。  相似文献   

13.
A 2.45GHz microwave-driven ion source is being used to provide 40mA of deuterium ion beam (peak current) for an RFQ accelerator as part of a neutron source system.We have also designed a 60kV electrostatic LEBT using computer simulations.In our experiment,we measured the hydrogen and deuterium ion beam currents as functions of discharge power,gas flow,and magnetic field strength.The required beam current was obtained using leas than 700W of net microwave power with a gas flow of less than 1.5sccm.From the rise time data,it was determined that in order to obtain a high percentage of atomic ions in the beam, the beam extraction should start after 1ms of switching on the microwave power.At steady state,the proton fraction was above 90%.  相似文献   

14.
The characteristics of ion beam extraction and focused to a volume as small as possible were investigated with the aid of computer code SIMION 3D version 7.This has been used to evaluate the extraction characteristics(accel-decel system)to generate an ion beam with low beam emittance and high brightness.The simulation process can provide a good study for optimizing the extraction and focusing system of the ion beam without any losses and transported to the required target.Also,a study of a simulation model for the extraction system of the ion source was used to describe the possible plasma boundary curvatures during the ion extraction that may be affected by the change in an extraction potential with a constant plasma density meniscus.  相似文献   

15.
A cylindrical triode charger for unipolar diffusion charging of aerosol particles was designed, constructed, and evaluated. The corona discharge characteristics were studied in this cylindrical triode charger. For the process the current–voltage characteristics were determined, as were the ion number concentration, the nit product, and the mean charge per particle as a function of particle diameter. The discharge and charging currents, and ion number concentration in the charging zone of the charger increased monotonically with corona voltage. The negative corona had a higher current than the positive corona. At the same corona voltage, the ion number concentration in the discharge zone was larger than the charging current for positive and negative coronas, with values of about 197 and 32 times and 645 and 99 times for the ion-driving voltages of 0 and 310 V, respectively. The average ion penetration for positive and negative coronas was 0.64 and 0.19% and 3.62 and 1.93% for the ion-driving voltages of 0 V and 310 V, respectively. The higher flow rate, shorter residence time, gave a lower Nit product. By calculation 14% of charged particles of 10 nm in diameter were lost to the outer cylinder because of the electrostatic field effect. The charger does not use a sheath of air flow along the walls or the perforated screen opening, it has low diffusion and space charge losses due to the short column charging zone, and is a low complexity and inexpensive system. It worked as well as more sophisticated and expensive commercially available chargers.  相似文献   

16.
为了克服目前潘宁(PIG)离子源中子管引出正离子所带来的诸多不利因素,使用PIG型氢负离子源作为中子管的离子源,研究了氢负离子产生的机理,以期在中子管中获得应用。给出了PIG离子源结构,根据氢负离子产生的方式和条件,结合CST软件仿真实验,确定在对阴极和引出孔附近区域存在氢负离子,而且是氢负离子密度比较大的区域。实验中,通过负离子源产生系统证实了氢负离子的存在及分布规律,中子监测仪测量自成靶50 mm负离子源陶瓷中子管,中子产额较传统正离子中子管高出一个数量级以上。  相似文献   

17.
黄继鹏  乔双 《强激光与粒子束》2014,26(2):024002-248
为了克服目前潘宁(PIG)离子源中子管引出正离子所带来的诸多不利因素,使用PIG型氢负离子源作为中子管的离子源,研究了氢负离子产生的机理,以期在中子管中获得应用。给出了PIG离子源结构,根据氢负离子产生的方式和条件,结合CST软件仿真实验,确定在对阴极和引出孔附近区域存在氢负离子,而且是氢负离子密度比较大的区域。实验中,通过负离子源产生系统证实了氢负离子的存在及分布规律,中子监测仪测量自成靶50mm负离子源陶瓷中子管,中子产额较传统正离子中子管高出一个数量级以上。  相似文献   

18.
汤明杰  杨涓  金逸舟  罗立涛  冯冰冰 《物理学报》2015,64(21):215202-215202
微型电子回旋共振(ECR)离子推力器可满足微小航天器空间探测的推进需求. 为此, 本文开展直径20 mm的微型ECR离子源结构优化实验研究. 根据放电室内静磁场和ECR谐振区的分布特点, 研究不同微波耦合输入位置对离子源性能的影响, 结果表明环形天线处在高于ECR谐振强度的强磁场区域时, 微波与等离子体实现无损耦合, 电子共振加热效果显著, 引出离子束流较大. 根据放电室电磁截止特性, 结合微波电场计算, 研究放电容积对离子源性能的影响, 实验表明过长或过短的腔体长度会导致引出离子束流下降甚至等离子体熄灭. 经优化后离子源性能测试表明, 在入射微波功率2.1 W、氩气流量14.9 μg/s下, 可引出离子束流5.4 mA, 气体放电损耗和利用率分别为389 W/A和15%.  相似文献   

19.
磁场调控型离子源在离子源等离子体扩散空间中引入轴向强脉冲磁场,磁场起两方面的作用,一是形成潘宁放电效应,使原子、气体分子碰撞电离效率增加;二是在脉冲强磁场的作用下,强轴向磁场将质量较轻的离子约束在轴线上,对质量较重的金属离子约束能力较弱,导致其在等离子体膨胀引出通道中碰壁损失,能够提升引出轻离子的比例。开展了磁场调控的离子源放电结构、强脉冲螺线管磁场以及引出束流光学结构的设计;测量分析了引出离子流强和离子打靶束斑形貌。研究结果表明,强轴向磁场通过等离子体对混合离子成分的筛选作用,可有效提高引出离子流强中的轻离子成分比例。  相似文献   

20.
吸收式光纤温度传感器的研究   总被引:1,自引:1,他引:0  
提出了一种利用半导体光吸收谱随温度变化原理设计的半导体吸收式光纤温度传感器.该传感器用GaAs晶片作为温度敏感元件,以光纤作为传光介质,发光二极管作为光源,光电管作为光电转换器件.利用双光束补偿原理,消除了由于光源不稳定产生的干扰.研制出的光纤传感器具有体积小,结构简单,抗电磁干扰,灵敏度高等优点.实验表明:该传感器在-20℃~85℃温度范围内可以达到0.1℃的准确度,可以实现强电磁干扰下的高空飞行器内环境温度的测量.为进一步实现光传飞控系统中的温度测控奠定了基础.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏