首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this paper we present the spatial resolution enhancement and noise reduction level achieved with an optimized inductively coupled surface coil specifically designed for our experiments. The technique of designing and implementing customized coils for magnetic resonance imaging of very small structures is described. We have designed a low cost prototype of an inductively coupled circular surface coil, tuned for 1H magnetic resonance imaging at 200 MHz. The coil is mounted on a customized teflon support. The inductive coupling used in this coil improves the signal-to-noise ratio by reducing various loss mechanisms (specially the dielectric losses). Test images have been acquired to determine the evolution of induced articular lesions in a rabbit animal model, as well as brain tumors in rats. The images show high spatial resolution, excellent B1 field homogeneity and no “hot spots”. Comparing these images with those acquired with conventional coils, one finds better spatial resolution and signal-to-noise ratio, as well as larger field of view with less intense illumination artifact. The methodology can be used in any application that requires high quality imaging of small structures.  相似文献   

2.
胡洋  王秋良  李毅  朱旭晨  牛超群 《物理学报》2016,65(21):218301-218301
在磁共振成像设备中,为了消除目标区域内的高阶谐波磁场分量,传统方法采用无源匀场,但该方法匀场精度较低,针对性较差,适用于全局匀场,而有源匀场则可以通过优化线圈分布来产生所需要的特定的磁场分布.但是,由于匀场线圈线型的复杂度会随着线圈阶数的增加而增加,难以满足设计需要,因此本文提出了一种用于磁共振成像超导匀场线圈系统的多变量非线性优化设计方法.该方法基于边界元方法,将匀场线圈所产生的磁场与目标磁场之间的偏差作为目标函数,线匝间距、线圈半径等作为约束条件,通过非线性优化算法,得到满足设计要求的线圈分布.通过一个中心磁场为0.5 T的开放式双平面磁共振成像超导轴向匀场线圈的设计案例,说明本方法具有计算效率高、灵活性好的特点.  相似文献   

3.
韩圣星  王焕宇  高新亮 《中国物理 B》2022,31(2):25202-025202
The magnetic merging process related to pairwise magnetic islands coalescence is investigated by two-dimensional particle-in-cell simulations with a guide field.Owing to the force of attraction between parallel currents within the initial magnetic islands,the magnetic islands begin to approach each other and merge into one big island.We find that this newly formed island is unstable and can be divided into two small magnetic islands spontaneously.Lastly,these two small islands merge again.We follow the time evolution of this process,in which the contributions of three mechanisms of electron acceleration at different stages,including the Fermi,parallel electric field,and betatron mechanisms,are studied with the guide center theory.  相似文献   

4.
ITERУ������Ȧ�Ľṹ����   总被引:3,自引:1,他引:2       下载免费PDF全文
阐述了ITER遥控运输车初步结构和工作状况,运用有限元方法对其进行模态分析并在地震载荷作用下进行加速度反应谱分析,验证了遥控运输车在地震情况下的安全性并给下一步的优化设计和实验提供了参考数据。  相似文献   

5.
Applications of low-field magnetic resonance imaging (MRI) systems (<0.3 T) are limited due to the signal-to-noise ratio (SNR) being lower than that provided by systems based on superconductive magnets (≥1.5 T). Therefore, the design of radiofrequency (RF) coils for low-field MRI requires careful consideration as significant gains in SNR can be achieved with the proper design of the RF coil. This article describes an analytical method for the optimization of solenoidal coils. Coil and sample losses are analyzed to provide maximum SNR and optimum B1 field homogeneity. The calculations are performed for solenoidal coils optimized for the human head at 0.2 T, but the method could also be applied to any solenoidal coil for imaging other anatomical regions at low field. Several coils were constructed to compare experimental and theoretical results. A head magnetic resonance image obtained at 0.2 T with the optimum design is presented.  相似文献   

6.
The task of designing the geometry of a set of current-carrying coils that produce the magnetic field required to confine a given plasma equilibrium in stellarators is expressed as a minimization principle, namely that the coils minimize a suitably defined error expressed as a surface integral, which is recognized as the quadratic-flux. A penalty on the coil length is included to avoid pathological solutions. A simple expression for how the quadratic-flux and coil length vary as the coil geometry varies is derived, and an expression describing how this varies with variations in the surface geometry is derived. These expressions allow efficient coil-design algorithms to be implemented, and also enable efficient algorithms for varying the shape of the plasma surface in order to simplify the coil geometry, and a numerical illustration of this is given.  相似文献   

7.
A topology optimization method based on the solid isotropic material with penalization interpolation scheme is utilized for designing gradient coils for use in magnetic resonance microscopy. Unlike the popular stream function method, the proposed method has design variables that are the distribution of conductive material. A voltage-driven transverse gradient coil is proposed to be used as micro-scale magnetic resonance imaging(MRI) gradient coils, thus avoiding introducing a coil-winding pattern and simplifying the coil configuration. The proposed method avoids post-processing errors that occur when the continuous current density is approximated by discrete wires in the stream function approach. The feasibility and accuracy of the method are verified through designing the z-gradient and y-gradient coils on a cylindrical surface.Numerical design results show that the proposed method can provide a new coil layout in a compact design space.  相似文献   

8.
Recently the capabilities of single sided nuclear magnetic resonance (NMR) devices have been extended towards three-dimensional imaging. This paper details the use of a magnetic field sweep coil to obtain spatial resolution in the plane normal to the surface of a hand-held NMR device-the NMR-Mobile Universal Surface Explorer (MOUSE). One-dimensional depth profiles can be recorded by varying the current in the sweep coils. Preliminary results from multi-layer rubber and glass sample phantoms demonstrate a sample penetration depth of 7 mm. Two-dimensional images were acquired via the inclusion of phase encoding coils. Non-destructive cross-sectional images of small rubber phantoms were successfully recorded.  相似文献   

9.
PHYSICAL CHARACTERISTICS OF ELECTROMAGNETIC LEVITATION PROCESSING   总被引:1,自引:0,他引:1       下载免费PDF全文
王楠  解文军  魏炳波 《中国物理》1999,8(7):503-513
Electromagnetic levitation has developed from a pure physical phenomenon into a practical containerless processing technique in the fields of both applied physics and materials science. In order to obtain a better understanding of this processing technique, two typical levitation coils were designed and the physical characteristics in levitation droplets suspended in these two coils, such as electromangetic field, levitation force field, total levitation force, and power absorption, were analyzed numerically and calculated in this paper. It was found that the eddy current density, together with the magnetic flux density and levitation force density, increases rapidly with radius as it approaches sample surface. The maximum levitation force produced by coil A is larger than that of coil B, whereas the levitated sample can obtain less power absorption at the equilibrium position in the former coil than that in the latter one. Moreover, the calculated results also demonstrated that the levitation ability decreases as the atomic number increases. The larger the material's electrical resistivity, the easier the samples can obtain more power absorption.  相似文献   

10.
Hyperpolarized 13C magnetic resonance spectroscopy in pig models enables metabolic activity mapping, providing a powerful tool for the study of the heart physiology, but requires the development of dedicated radiofrequency coils, capable of providing large field of view with high signal-to-noise ratio (SNR) data. This work describes the simulations and the tests of a transmit-only (TX) volume coil/receive-only (RX) surface coil both designed for hyperpolarized studies of pig heart with a clinical 3T scanner. The coil characterization is performed by developing an SNR model for coil performance in terms of coil resistance, sample-induced resistance and magnetic field pattern. In particular, coil resistances were calculated from Ohm’s law, while magnetic field patterns and sample-induced resistances were calculated using a numerical finite-difference time-domain algorithm. Experimental phantom chemical shift image, showed good agreement with the theoretical SNR-vs-depth profiles and highlighted the advantage of the novel configuration over the single transmit–receive coils throughout the volume of interest for cardiac imaging in pig. Finally, the TX-birdcage/RX-circular configuration was tested by acquiring metabolic maps with hyperpolarized [1-13C] pyruvate injected i.v. in a pig. The results of the phantom and pig experiments show the ability of the coil configuration to image well the metabolites distribution.  相似文献   

11.
A novel coil, called Z coil, is presented. Its function is to reduce the strong thermal effects produced by rf heating at high frequencies. The results obtained at 500MHz in a 50 microl sample prove that the Z coil can cope with salt concentrations that are one order of magnitude higher than in traditional solenoidal coils. The evaluation of the rf field is performed by numerical analysis based on first principles and by carrying out rf field measurements. Reduction of rf heating is probed with a DMPC/DHPC membrane prepared in buffers of increasing salt concentrations. The intricate correlation that exists between the magnetic and electric field is presented. It is demonstrated that, in a multiply tuned traditional MAS coil, the rf electric field E(1) cannot be reduced without altering the rf magnetic field. Since the detailed distribution differs when changing the coil geometry, a comparison involving the following three distinct designs is discussed: (1) a regular coil of 5.5 turns, (2) a variable pitch coil with the same number of turns, (3) the new Z coil structure. For each of these coils loaded with samples of different salt concentrations, the nutation fields obtained at a certain power level provide a basis to discuss the impact of the dielectric and conductive losses on the rf efficiency.  相似文献   

12.
The main magnetic fields of mobile nuclear magnetic resonance (NMR) magnets differ from those of conventional NMR and magnetic resonance imaging (MRI) magnets. In the Halbach magnet, the main field B 0 is perpendicular to the longitudinal axis, the symmetry of the current distribution with respect to the symmetry of the magnetic field differs from that in conventional target-field applications, and the current distribution on the coil surface cannot be expressed in terms of periodic basis functions. To obtain the winding pattern of the coil, an efficacious target-field approach. The surface of a coil is divided into small discrete elements, where each element is represented by a magnetic dipole. From the stream function of the elements, the resultant magnetic field is calculated. The optimization strategy follows an objective function defined by the power dissipation or efficiency of the coil. This leads to the optimum stream function on the coil surface, whose contour lines define the winding patterns of the coil. This paper shows winding patterns designed of shim coils for Halbach magnet and illustrates the craft of a shim coil using flexible printed circuit board. The performance of the coils is verified by simulating the fields they produce over the sensitive volume.  相似文献   

13.
Spin-averaged and spin-polarized scanning tunneling spectroscopy at low temperature was performed on nanometer-scale triangular Co islands grown epitaxially on Cu(111) in the submonolayer coverage regime. Two structurally different island types can clearly be distinguished by their spin-averaged electronic structure. Spin-polarized measurements allow a separation of spectral contributions arising from different island stacking or from opposite magnetization states, respectively. In an applied magnetic field, both island types are found to be magnetized perpendicular to the surface, with large values of saturation field, remanence, and coercivity.  相似文献   

14.
This paper describes a superconducting magnet system for the China Accelerator Driven System (CADS). The magnetic field is provided by one main, two bucking and four racetrack coils. The main coil produces a central field of up to 7 T and the effective length is more than 140 mm, the two bucking coils can shield most of the fringe field, and the four racetrack superconducting coils produce the steering magnetic field. Its leakage field in the cavity zone is about 5× 10-5 T when the shielding material Niobium and cryogenic permalloy are used as the Meissner shielding and passive shielding respectively. The quench calculations and protection system are also discussed.  相似文献   

15.
 采用特殊工艺制作了HIRFL-CSR电子冷却装置冷却段高精度螺线管线圈,两个产生反向磁场的线圈同轴、平行地放置在特制的测量装置上,高精度霍尔探头位于测量装置中心平面上,探头测量面与测量装置轴线重合,测量单个线圈磁场的横向分量,调节线圈几何轴相对于测量装置轴线的夹角,测得线圈磁轴的偏角小于1×10-3。  相似文献   

16.
The use of surface coils in magnetic resonance is widespread. Examples include MRI, detection of subsurface aquifers by NMR, and, more recently, landmine detection by nuclear quadrupole resonance. In many of these cases a finite-sized sample to be examined is contained within a larger medium that is a poor electrical conductor, and eddy currents induced by the RF fields provide a loss mechanism that reduces the effective quality factorQof the transmitter and receiver coils. Here the losses induced in a circular surface coil (a horizontal loop antenna) separated a distance from a dissipative medium are calculated and compared to measurements. It is shown that often the overall efficiency of the coil for magnetic resonance can be improved by displacing the coil away from the conducting medium a prescribed “lift-off” distance. The use of a gradiometer as a surface coil is also examined, and it is shown by theory and experiment that in certain circumstances such a gradiometer can be more efficient than a conventional surface coil for inspection of conducting media.  相似文献   

17.
In standard cylindrical gradient coils consisting of a single layer of wires, a limiting factor in achieving very large magnetic field gradients is the rapid increase in coil resistance with efficiency. This is a particular problem in small-bore scanners, such as those used for MR microscopy. By adopting a multi-layer design in which the coil wires are allowed to spread out into multiple layers wound at increasing radii, a more favourable scaling of resistance with efficiency is achieved, thus allowing the design of more powerful gradient coils with acceptable resistance values. Previously this approach has been applied to the design of unshielded, longitudinal, and transverse gradient coils. Here, the multi-layer approach has been extended to allow the design of actively shielded multi-layer gradient coils, and also to produce coils exhibiting enhanced cooling characteristics. An iterative approach to modelling the steady-state temperature distribution within the coil has also been developed. Results indicate that a good level of screening can be achieved in multi-layer coils, that small versions of such coils can yield higher efficiencies at fixed resistance than conventional two-layer (primary and screen) coils, and that performance improves as the number of layers of increases. Simulations show that by optimising multi-layer coils for cooling it is possible to achieve significantly higher gradient strengths at a fixed maximum operating temperature. A four-layer coil of 8 mm inner diameter has been constructed and used to test the steady-state temperature model.  相似文献   

18.
李华  张树林  张朝祥  孔祥燕  谢晓明 《中国物理 B》2016,25(6):68501-068501
For a practical superconducting quantum interference device(SQUID) based measurement system,the Tesla/volt coefficient must be accurately calibrated.In this paper,we propose a highly efficient method of calibrating a SQUID magnetometer system using three orthogonal Helmholtz coils.The Tesla/volt coefficient is regarded as the magnitude of a vector pointing to the normal direction of the pickup coil.By applying magnetic fields through a three-dimensional Helmholtz coil,the Tesla/volt coefficient can be directly calculated from magnetometer responses to the three orthogonally applied magnetic fields.Calibration with alternating current(AC) field is normally used for better signal-to-noise ratio in noisy urban environments and the results are compared with the direct current(DC) calibration to avoid possible effects due to eddy current.In our experiment,a calibration relative error of about 6.89 × 10-4is obtained,and the error is mainly caused by the non-orthogonality of three axes of the Helmholtz coils.The method does not need precise alignment of the magnetometer inside the Helmholtz coil.It can be used for the multichannel magnetometer system calibration effectively and accurately.  相似文献   

19.
Copper foil has been widely employed in conventional radio frequency (RF) birdcage coils for magnetic resonance imaging (MRI). However, for ultrahigh-field (UHF) MRI, current density distribution on the copper foil is concentrated on the surface and the edge due to proximity effect. This increases the effective resistance and distorts the circumferential sinusoidal current distribution on the birdcage coils, resulting in low signal-to-noise ratio (SNR) and inhomogeneous distribution of RF magnetic (B1) field. In this context, multiple parallel round wires were proposed as legs of a birdcage coil to optimize current density distribution and to improve the SNR and the B1 field homogeneity. The design was compared with three conventional birdcage coils with different width flat strip surface legs for a 9.4 T (T) MRI system, e.g., narrow-leg birdcage coil (NL), medium-leg birdcage coil (ML), broad-leg birdcage coil (BL) and the multiple parallel round wire-leg birdcage coil (WL). Studies were carried out in in vitro saline phantom as well as in vivo mouse brain. WL showed higher coil quality factor Q and more homogeneous B1 field distribution compared to the other three conventional birdcage coils. Furthermore, WL showed 12, 10 and 13% SNR increase, respectively, compared to NL, ML and BL. It was proposed that conductor’s shape optimization could be an effective approach to improve RF coil performance for UHF MRI.  相似文献   

20.
Magnetic islands in free-boundary stellarator equilibria are suppressed using a procedure that iterates the plasma equilibrium equations and, at each iteration, adjusts the coil geometry to cancel resonant fields produced by the plasma. The coils are constrained to satisfy certain measures of engineering acceptability and the plasma is constrained to ensure kink stability. As the iterations continue, the coil geometry and the plasma simultaneously converge to an equilibrium in which the island content is negligible. The method is applied with success to a candidate plasma and coil design for the National Compact Stellarator Experiment [Phys. Plasmas 8, 2083 (2001)]].  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号