首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Combined measurements of piezoelectric quartz crystal impedance (PQCI) and electrochemical impedance spectrum (EIS) using a suitable isolation capacitance is reported for the first time to monitor in situ adsorption and acidic denaturation of human serum albumin (HSA) on gold electrodes in Britton-Robinson (B-R) buffers. This method provides simultaneously mutual-interference-free and accurate parameters of EIS and PQCI. Effects of surface thiol-modification, electrode-potential and solution pH on HSA adsorption were examined and discussed. Comparative experiments of HSA adsorption in a B-R buffer of pH 6.42 on bare, cysteine- and 1-dodecanethiol-modified gold electrodes revealed that HSA adsorption is more significant on a hydrophobic (1-dodecanethiol-modified) surface. Insignificant electrode-potential effect implied minor electrostatic effects on HSA adsorption. The adsorption amount of HSA at pH 3.28 was found to be notably greater than those at pH 4.84 and 6.42. To characterize HSA adsorption, electrode standard rate constants (ks) of the Fe(CN)63−/Fe(CN)64− couple were measured before and after HSA adsorption. The ks-pH curves on an HSA-modified Au electrode revealed that ks increased abruptly with the decrease of solution pH below pH ∼4. Moreover, pH-dependent responses of the resonant frequency, the motional resistance, the double-layer capacitance, the capacitance of adsorbed HSA layer and the peak absorbance of HSA solutions at 278 nm all exhibited an inflexion change at pH ∼4, and these findings have been explained on the basis of acidic denaturation of HSA and electrical charges carried by HSA molecules.  相似文献   

2.
The pH sensitivity based on conducting polyaniline (PANI) and copolymer of aniline and o‐anthranilic acid (AA) films were studied using quartz crystal microbalance (QCM) technique and UV–Vis spectroscopy. The sensor was constructed from these polymer films coated on the electrode of the QCM. The resonant frequency changes as a function of pH in the range of 2–12 were measured. These changes are quantitative indication of the degree of dedoping or redoping of the polymer films upon the subsequent exposure of the electrode to 0.25 M sulfuric acid and different pH solutions. There are two linear regressions between the frequency change and pH with two different and opposite slopes in the regions from 2 to 9 and 9 to 12. The pH sensitivity of the copolymer film was found to be less than using the PANI film. Thin films of PANI and copolymer, which were chemically polymerized in a sulfuric acid solution, were deposited onto the inner walls of the quartz cuvettes. The UV–Vis absorption spectra of these films were measured in different pH solutions. Relations between the maximum absorption and its wavelength versus pH were constructed. The copolymer film shows some advantages over the PANI film. The difference between the PANI and copolymer films as pH sensors using the QCM and electronic absorption extends from the determination of pKa for both films. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

3.
The electrochemical piezoelectric quartz crystal impedance (EQCI), a combined technique of piezoelectric quartz crystal impedance (PQCI), electrochemical impedance (EI), and Fourier transform infrared spectroscopy-attenuated total internal reflectance spectroscopy (FTIR-ATR) were used to in situ study the adsorption process of fibrinogen onto the surface of biomaterials—TiO2 and hydroxyapatite (Ca5(PO4)3OH, HAP). The equivalent circuit parameters, the resonance frequencies and the half peak width of the conductance spectrum of the two biomaterial-modified piezoelectric quartz crystal (PQC) resonances as well as the FTIR-ATR spectra of fibrinogen during fibrinogen adsorption on TiO2 and HAP particles modified electrode surface were obtained. The adsorption kinetics and mechanism of fibrinogen were investigated and discussed as well. The results suggested that two consecutive steps occurred during the adsorption of fibrinogen onto TiO2 and hydroxyapatite (HAP) surface. The fibrinogen molecules were firstly adsorbed onto the surface, and then the rearrangement of adsorbed fibrinogen or multi-layered adsorption occurred. The FTIR-ATR spectroscopy investigations showed that the secondary structure of fibrinogen molecules was altered during the adsorption and the adsorption kinetics of fibrinogen related with the variety of biomaterials. These experimental results suggest a way for enriching biological analytical science and developing new applications of analytical techniques, such as PQCI, EI, and FTIR-ATR.  相似文献   

4.
Dynamic crystal impedance measurements were used to study the electrochemically-driven deposition of polyvinylferrocene (PVF) films from dichloromethane solutions of PVF onto Au electrodes of a quartz crystal microbalance. Under all the conditions studied, the PVF films were non-rigid, to an extent that depended upon several experimental factors. Films deposited from solutions containing perchlorate salts of tetraalkylammonium salts departed less from rigidity than those deposited under otherwise identical conditions from tetrafluoroborate media. In contrast, the use of different tetraalkylammonium cations, or the use of a potential sweep vs. a potential step from 0 V to the deposition potential (0.7 V), made no significant difference. The departure from rigid characteristics varied with coverage. For the interval of time during deposition that the coverage was 10–160 nmol cm−2 (of monomeric ferrocene units), the films showed no additional departure from rigidity. On the basis that the upper figure corresponds closely to a “monolayer” of terminally attached chains of mean length, we attribute this behaviour to the presence of a dense film, within which chain motion is considerably restrained.  相似文献   

5.
The carbohydrate research has emerged as a "new frontier" in chemical/biological field. The binding of lectin with carbohydrate is one of the important courses of life activities. The report studies concanavalin A (Con A)-glycogen interaction on gold electrode surfaces by electrochemical piezoelectric quartz crystal impedance (EPQCI) method. The piezoelectric quartz crystal (PQC) parameters, resonant frequency shift (Deltaf(0)) and the motional resistance change (DeltaR(1)), and the electrochemical impedance (EI) parameters, electrolyte resistance change (DeltaR(s)) and the double layer capacitance change (DeltaC(s)), were measured and discussed simultaneously. Two methods were adopted for measuring the Con A-glycogen association. Based on EPQCI measurement during Con A reaction with glycogen adsorbed on Au electrode, association constant K(a) and the amount of the binding sites s calculated are 1.48 x 10(6) M(-1) and 4.09, respectively. Based on single PQC measurement of glycogen reaction with Con A assembled on Au electrode, K(a) was estimated to be 1.26 x 10(6) M(-1).  相似文献   

6.
This study attempted to determine absolute heparin concentration in phosphate buffer solution (PBS, pH 7.4) by using quartz crystal microbalance (QCM) as an affinity biosensor. Electrochemical impedance spectroscopy (EIS) was also used to investigate immobilization of protamine and heparin assay. In addition, the effectiveness of physical adsorption in immobilizing protamine was confirmed by examining the preparation conditions, including the incubation time and protamine concentration. It induced maximum decrease (ca. −100 Hz) in oscillating frequency of QCM by applying 20 mg/ml protamine and 20 min for incubation in PBS. Heparin adsorption onto protamine-modified electrode in PBS revealed an exponential-like binding curve and long duration for reaching the steady state in frequency response of QCM. Moreover, two linear calibration curves were obtained judging from the initial slope (df/dt) and the frequency change (Δf) of QCM obtained after a binding interval (600 s) for heparin concentrations from 0 to 3.0 and 7.0 U/ml, respectively. In EIS analysis, calibration curves with linear concentration range of 0-3.0 U/ml were obtained for heparin in PBS when ferrocyanide was used as an electroactive marker.  相似文献   

7.
电化学石英晶体微天平的近期应用进展   总被引:3,自引:1,他引:3  
本文对近几年来电化学石英晶体微天平(EQCM)在吸附,膜的形成,腐蚀和电沉积等方面的应用进行了概述,并对其应用现状和前景进行了分析。  相似文献   

8.
The electrochemical quartz crystal microbalance (EQCMB) method has been used to evaluate the processes which occur in/on the palladium electrode in basic solutions. Hydrogen electrosorption in palladium is accompanied by an additional frequency shift that can be attributed to the stresses generated inside the Pd metal. A non-linear dependence between the mass change and the charge consumed during hydrogen oxidation in the Pd electrode has been found for hydrogen absorbed in the α- and β-phases. This effect precludes the objective estimation of the amount of hydrogen absorbed inside the Pd electrode. The EQCMB method has been used, however, for studying the surface electrode processes on the Pd electrode, i.e. specific anion adsorption, surface oxidation and dissolution. Also, the structure of the palladium oxide formed on the Pd surface during electrochemical oxidation is discussed in this paper and the effect of the anodic limiting potential on the oxide structure is reported. Received: 10 August 1999 / Accepted: 24 September 1999  相似文献   

9.
A new approach to an equivalent circuit analysis of impedance spectra of a conducting polyaniline (PAni) layer is presented. Film properties are often modeled by constant-phase elements (CPE), which are closer to experimental results than capacitors. We want to take an insight into the CPE. We propose a novel equivalent circuit based on the Frumkin-Melik-Gaikazyan adsorption model, as we suppose that the PAni layer molecules may behave like other adsorbing and relaxing organic compounds. Measurements are performed using recently developed experimental technique—dynamic electrochemical impedance spectroscopy. Obtained spectra are analyzed using the proposed equivalent circuits. Characteristics of several parameters are analyzed and discussed. Published in Russian in Elektrokhimiya, 2007, Vol. 43, No. 9, pp. 1111–1119. The text was submitted by the authors in English.  相似文献   

10.
Polyaniline (PANI) nanotubes were prepared by oxidation of aniline in 0.4 M acetic acid. They were subsequently used as a reductant of silver nitrate in 1 M nitric acid, water or 1 M ammonium hydroxide at various molar ratios of silver nitrate to PANI. The resulting PANI-silver composites contained silver nanoparticles of 40–60 nm size along with macroscopic silver flakes. Under these experimental conditions, silver was always produced outside the PANI nanotubes. Changes in the molecular structure of PANI were analyzed by FTIR spectroscopy. Silver content in the composites was determined as a residue by thermogravimetric analysis, and confirmed by density measurements. The highest conductivity of a composite, 68.5 S cm−1, was obtained at the nitrate to PANI molar ratio of 0.67 in water. Also, the best reaction yield was obtained in water. Reductions performed in an acidic medium gave products with conductivity of 10−4–10−2 S cm−1, whereas the reaction in alkaline solution yielded non-conducting products.  相似文献   

11.
A new method for the quantitative determination of palladium(II) by the electrochemical quartz crystal microbalance (EQCM) technique has been developed. Using a bare carbon-coated quartz crystal, Pd(II) ions are directly deposited from aqueous solution as palladium metal onto the crystal surface, and the Pd(II) concentration is determined with a detection limit of 0.0156 mM, or 1.66 ppm. No complexing agent or preconcentration of palladium is required for the analysis. The palladium is stripped from the crystal through its electrochemical oxidation, regenerating the crystal for subsequent multi-cycle palladium analyses. A conventional gold-coated quartz crystal was incapable of carrying out the same measurements. The EQCM technique presented is simple, sensitive, and reproducible for the detection of this widely used precious metal.  相似文献   

12.
An electrodeless piezoelectric quartz crystal system was constructed with a quartz crystal plate, electrolyte solutions and platinum plates or rods immersed in the solutions for connecting to an oscillator, instead of the electrodes. The crystal without electrodes oscillates in the solutions. The frequency varies with temperature, specific conductance of the solutions and the mass change of the plate caused by the adsorption of material from the solution in, the same way as a normal piezoelectric quartz crystal with electrodes.  相似文献   

13.
14.
The chemical oxidation of aniline with ammonium peroxydisulfate to form polyaniline (PANI) films has been studied in different aqueous acid mediums such as HCl, HNO3, and H2SO4. The yield and the growth rate of the PANI film deposition were measured using the quartz crystal microbalance (QCM) technique. The effect of different salts such as KCl, NaNO3, and K2SO4 and their concentration on the yield and the growth rate of the film formation are investigated. The yield of PANI film deposition depends on the acid used and the type of salts as well as their concentrations. When HCl and HNO3 were used as media, the addition of salts with the same anion has no effect. However, when H2SO4 was used as media, the addition of salts with the same anions as the medium enhances the yield of PANI film deposition. The UV–visible spectra of the produced PANI films in the absence and presence of the salts are also studied. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

15.
Human serum albumin (HSA) was immobilized on the surface of colloidal Au and exposed to diazepam. Colloidal Au were at first self-assembled on the gold electrode through the thiol groups of a 1,6-hexanedithiol monolayer. The real-time course of the resonant frequency and equivalent circuit parameters of the sensor during the protein-diazepam binding was determined for the first time by piezoelectric quartz crystal impedance (PQCI). On the basis of the multidimensional information provided by the PQCI analysis, it was concluded that the decrement of the observed frequency was mainly ascribable to the mass loading on the sensor surface. Compared with a bare gold electrode, the gold electrode self-assembled from nanogold colloids exhibits maintained biocompatibility, increased capacity, and more bioactivity. Cyclic voltammetry and electrochemical impedance techniques were used to investigate the immobilization of HSA and the interaction between HSA and diazepam. Results testified that gold colloid could play the role of an efficient electron-conducting tunnel and have a very high ratio of surface to volume. Additionally, the kinetics of the binding process was investigated. The estimated binding constant (K) and the number of binding site (n) on one HSA molecule were 1.66 x 10(6) mol l(-1) and 1.28, respectively.  相似文献   

16.
电化学过程的石英晶体阻抗分析法已用于现场获取电活性聚合物粘弹性等信息[1,2].本文联用HP4395A阻抗/网络/频谱分析仪和EG&GM283恒电位仪开发出电化学石英晶体阻抗系统(ElectrochemicalQuartzCrystalImpedan...  相似文献   

17.
Thequartzcrystalimpedancetechniqueisapowerfulmethodtocharacterizecrystalresonancesincemultipleinformationaboutcrystalresonanceincludingtheresonantfrequencyandchangesinsomephysicaland/orchemicalpropertiesofthetestsystemcanFigure1.Equivalentelectricalc...  相似文献   

18.
The electrochemical quartz crystal microbalance (EQCMB) method has been used to study the processes of hydrogen absorption/desorption in Pd-Ni alloy electrodes. It was found that hydrogen electrosorption is accompanied by an additional frequency shift, attributed to the stresses generated inside the alloy. The influence of stresses on the EQCMB response depends on the amount of absorbed hydrogen and the alloy composition. From the comparison of the EQCMB results with Pd-Ni alloy absorption capabilities data, it was concluded that the decrease of the hydrogen sorption capacity at a Ni content of ca. 25–30 at% is due to an excessive generation of stresses in the alloy lattice. Also, a dependency of the rate of hydrogen absorption in Pd-Ni alloys on potential is reported. Electronic Publication  相似文献   

19.
Quartz crystal microbalance with dissipation (QCM-D) monitoring is a powerful tool used to sensitively examine the real-time responses of polymer films to external responses. For example, the technique is commonly used to monitor film growth, material adsorption, thin film swelling, and ion exchange. With its rapidly expanding use, this review is intended to introduce new users to the basic principles of QCM-D, along with practical challenges and remedies specific to polymer thin films. For both new and experienced users, specific case studies are highlighted including layer-by-layer assembly, electrochemical QCM-D, swelling, sensing, and biological application. Last, the review recommends future directions for research and areas of growth.  相似文献   

20.
New oxide films have been electrodeposited from [P2Mo18O62]6− by potential cycling in mildly acidic aqueous media. To obtain an adherent and persistent film, it is necessary that more than six electrons/molecule be fixed on the framework of the heteropolyanion. The film is then studied in pure supporting electrolyte. In this medium, a remarkable current increase is observed during the potential cycling. Whether the film is deposited on a glassy carbon electrode or on the gold electrode of an electrochemical quartz crystal microbalance (EQCM), exactly the same steady current increase up to a maximum is obtained in cyclic voltammetric measurements. The EQCM reveals a steady mass increase during the continuous cycling of the film in the supporting electrolyte. This behaviour is interpreted as featuring an irreversible water and electrolyte intake into the film, up to a maximum, after which the phenomena observed during reduction and oxidation processes are taken as featuring intercalation/deintercalation, respectively. This behaviour is much the same as described in the literature for WO3 and MoO3 bronzes, except that the present films seem very stable and have shown no tendency to dissolve or deactivate. Received: 2 December 1998 / Accepted: 26 January 1999  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号