首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Ozer ET  Güçer S 《Talanta》2011,84(2):362-367
The determination of six phthalate acid esters was achieved in artificial saliva using gas chromatography-mass spectrometry following activated carbon enrichment of samples. Central composite experimental design was applied to optimize method parameters, such as pH, adsorption time and amount of activated carbon. The best compromise of analytical conditions for the simultaneous determination of analytes from spiked artificial saliva were found to be: pH (3), adsorption time (30 min), activated carbon amount (1.8 g L−1) and elution solvent (chloroform). These conditions were applied to study the migration of phthalate acid esters from different children's toys into saliva. A horizontal agitation method was applied to extract the analytes from plastic toys into saliva for 2 h at 37 °C. The detection limits of the method were in the range of 1.3-5.1 μg L−1, while the relative standard deviation (%) values for the analysis of 100 μg L−1 of the analytes were below 3.0% (n = 5). Di-2-ethylhexyl phthalate was the main analyte found in these samples.  相似文献   

2.
A simple and efficient liquid-phase microextraction (LPME) technique was developed using directly suspended organic microdrop coupled with gas chromatography–mass spectrometry (GC–MS), for the extraction and the determination of phthalate esters (dimethyl phthalate, diethyl phthalate, diallyl phthalate, di-n-butyl phthalate (DnBP), benzyl butyl phthalate (BBP), dicyclohexyl phthalate and di-2-ethylhexyl phthalate (DEHP)) in water samples. Microextraction efficiency factors, such as nature and volume of the organic solvent, temperature, salt effect, stirring rate and the extraction time were investigated and optimized. Under the optimized extraction conditions (extraction solvent: 1-dodecanol; extraction temperature: 60 °C; microdrop volume: 7 μL; stirring rate: 750 rpm, without salt addition and extraction time: 25 min), figures of merit of the proposed method were evaluated. The values of the detection limit were in the range of 0.02–0.05 μg L−1, while the R.S.D.% value for the analysis of 5.0 μg L−1 of the analytes was below 7.7% (n = 4). A good linearity (r2 ≥ 0.9940) and a broad linear range (0.05–100 μg L−1) were obtained. The method exhibited enrichment factor values ranging from 307 to 412. Finally, the designed method was successfully applied for the preconcentration and determination of the studied phthalate esters in different real water samples and satisfactory results were attained.  相似文献   

3.
This study aims at developing a novel, sensitive, fast, simple and convenient method for separation and preconcentration of trace amounts of fluoxetine before its spectrophotometric determination. The method is based on combination of magnetic mixed hemimicelles solid phase extraction and dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene as a sorbent. The magnetic graphene was synthesized by a simple coprecipitation method and characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). The retained analyte was eluted using a 100 μL mixture of methanol/acetic acid (9:1) and converted into fluoxetine-β-cyclodextrin inclusion complex. The analyte was then quantified by fiber optic linear array spectrophotometry as well as mode-mismatched thermal lens spectroscopy (TLS). The factors affecting the separation, preconcentration and determination of fluoxetine were investigated and optimized. With a 50 mL sample and under optimized conditions using the spectrophotometry technique, the method exhibited a linear dynamic range of 0.4–60.0 μg L−1, a detection limit of 0.21 μg L−1, an enrichment factor of 167, and a relative standard deviation of 2.1% and 3.8% (n = 6) at 60 μg L−1 level of fluoxetine for intra- and inter-day analyses, respectively. However, with thermal lens spectrometry and a sample volume of 10 mL, the method exhibited a linear dynamic range of 0.05–300 μg L−1, a detection limit of 0.016 μg L−1 and a relative standard deviation of 3.8% and 5.6% (n = 6) at 60 μg L−1 level of fluoxetine for intra- and inter-day analyses, respectively. The method was successfully applied to determine fluoxetine in pharmaceutical formulation, human urine and environmental water samples.  相似文献   

4.

Magnetic graphene oxide/lanthanum phosphate nanocomposite (MGO@LaP) was synthesized and used as an efficient adsorbent for magnetic dispersive microsolid-phase extraction (MD-µ-SPE) of pesticides before gas chromatography–electron capture detector (GC–ECD) analysis. The adsorbent was thoroughly characterized with scanning electron microscopy, vibrating sample magnetometer, energy-dispersive X-ray spectroscopy, and Fourier transform infrared spectroscopy. Optimized extraction conditions were investigated concerning extraction time, adsorbent amount, sample pH, and salt amount as well as desorption conditions (type and volume of desorption solvent and desorption time). Under the optimal conditions, the method demonstrated good linearity (3–1500 µg L?1) with satisfactory determination coefficients of >?0.997 and low detection limits for both chlorpyrifos (0.67 µg L?1) and hexaconazole (0.89 µg L?1). Finally, the method showed high analyte relative recoveries in the range of 78–120% for the determination of the selected pesticides in water and fruit juice samples.

  相似文献   

5.
A headspace solid-phase microextraction, in conjunction with gas chromatography using a novel sol–gel calix[6]arene-contained fiber for the determination of phthalate acid esters in non-alcoholic beverages is described for the first time. A Taguchi’s L25 (56) orthogonal array experimental design was introduced to optimize the extraction parameters such as extraction temperature, extraction time, salt concentration and stirring speed. Under the optimized conditions, the method showed linear response of three to five orders of magnitude with correlation coefficients (r) better than 0.995. Owing to the good selectivity and high sensitivity of this fiber to phthalate acid esters, the extraction was carried out in real beverage matrix and low detection limits of 0.015–0.298 μg L?1 were achieved. The recoveries of standard addition tests amounted to 87.9–108.3% and the relative standard deviation values varied from 9.62 to 15.2%. The method was applied to the analysis of 12 kinds of beverages and bis-2-ethylhexyl phthalate was the sole analyte detected in these samples.  相似文献   

6.
This work presents a simple, fast and sensitive method for the preconcentration and quantification of graphene quantum dots (GQDs) in aqueous samples. GQDs are considered an object of analysis (analyte) not an analytical tool which is the most frequent situation in Analytical Nanoscience and Nanotechnology. This approach is based on the preconcentration of graphene quantum dots on an anion exchange sorbent by solid phase extraction and their subsequent elution prior fluorimetric analysis of the solution containing graphene quantum dots. Parameters of the extraction procedure such as sample volume, type of solvent, sample pH, sample flow rate and elution conditions were investigated in order to achieve extraction efficiency. The limits of detection and quantification were 7.5 μg L−1 and 25 μg L−1, respectively. The precision for 200 μg L−1, expressed as %RSD, was 2.8%. Recoveries percentages between 86.9 and 103.9% were obtained for two different concentration levels. Interferences from other nanoparticles were studied and no significant changes were observed at the concentration levels tested. Consequently, the optimized procedure has great potential to be applied to the determination of graphene quantum dots at trace levels in drinking and environmental waters.  相似文献   

7.
An electrochemical sensor for mercury (II) determination was developed by modifying the surface of a commercial screen-printed carbon electrode (SPCE) with a polystyrene sulfonate-NiO-carbon nanopowder composite material. Mercury measurements were performed by differential pulse anodic stripping voltammetry (DPASV). Sensor composition and measurement conditions were optimized using a multivariate experiment design. A screening experiment by using a Plackett-Burman design was first performed in order to determine the main contributing factors to the electrochemical response. The most important factors were employed to establish the interactions between different experimental variables and get the best conditions for mercury determination. For this purpose, a five level central composite design and a response surface methodology were used. The optimized method using the developed NiO-PSS-SPCE sensor presents a very low limit of detection of 0.021 μg L−1 and a linear response over two concentration ranges with two different slopes, from 0.05 to 2.0 μg L−1 and between 2.0 and 75 μg L−1. The sensor was successfully applied to mercury determination in water samples.  相似文献   

8.
A dispersive liquid–liquid microextraction (DLLME) method followed by high-performance liquid chromatography–triple quadrupole mass spectrometry has been developed for the simultaneous determination of linear alkylbenzene sulfonates (LAS C10, C11, C12, and C13), nonylphenol (NP), nonylphenol mono- and diethoxylates (NP1EO and NP2EO), and di-(2-ethylhexyl)phthalate (DEHP). The applicability of the method has been tested by the determination of the above mentioned organic pollutants in tap water and wastewater. Several parameters affecting DLLME, such as, the type and volume of the extraction and disperser solvents, sample pH, ionic strength and number of extractions, have been evaluated. Methanol (1.5 mL) was selected among the six disperser solvent tested. Dichlorobenzene (50 μL) was selected among the four extraction solvent tested. Enrichment factor achieved was 80. Linear ranges in samples were 0.01–3.42 μg L−1 for LAS C1013 and NP2EO, 0.09–5.17 μg L−1 for NP1EO, 0.17–9.19 μg L−1 for NP and 0.40–17.9 μg L−1 for DEHP. Coefficients of correlation were higher than 0.997. Limits of quantitation in tap water and wastewater were in the ranges 0.009–0.019 μg L−1 for LAS, 0.009–0.091 μg L−1 for NP, NP1EO and NP2EO and 0.201–0.224 μg L−1 for DEHP. Extraction recoveries were in the range from 57 to 80%, except for LAS C10 (30–36%). The method was successfully applied to the determination of these pollutants in tap water and effluent wastewater from Seville (South of Spain). The DLLME method developed is fast, easy to perform, requires low solvent volumes and allows the determination of the priority hazardous substances NP and DEHP (Directive 2008/105/EC).  相似文献   

9.
A new approach to performing extraction and preconcentration employing functionalized magnetic nanoparticles for the determination of trace metals is presented. Alumina-coated iron oxide nanoparticles were synthesized and used as the solid support. The nanoparticles were functionalized with sodium dodecyl sulfate and used as adsorbents for solid phase extraction of the analyte. Extraction, elution, and detection procedures were performed sequentially in the sequential injection lab-on-valve (SI-LOV) system followed by electrothermal atomic absorption spectrometry (ETAAS). Mixtures of hydrophobic analytes were successfully extracted from solution using the synthesized magnetic adsorbents. The potential use of the established scheme was demonstrated by taking cobalt as a model analyte. Under the optimal conditions, the calibration curve showed an excellent linearity in the concentration range of 0.01–5 μg L?1, and the relative standard deviation was 2.8% at the 0.5 μg L?1 level (n = 11). The limit of detection was 6 ng L?1 with a sampling frequency of 18 h?1. The present method has been successfully applied to cobalt determination in water samples and two certified reference materials.  相似文献   

10.
In this work, the application of a new pulsed amperometric detection (PAD) waveform at a glassy carbon electrode, operating in typical chromatographic mobile phases, is proposed for the sensitive and reproducible determination of arylethanolaminic and phenolic moiety based compounds (e.g. beta-agonists and polyphenols). Preliminary experiments by cyclic voltammetry were carried out to investigate the electrochemical behaviour and to select the detection and cleaning electrode potentials. The proposed potential-time profile was designed to prevent the carbon electrode fouling under repeated analyses, thus ensuring a reproducible and sensitive quantitative determination, without the need of any mechanical or chemical electrode cleaning procedure. The waveform electrochemical parameters, including detection and delay times, were optimized in terms of sensitivity, limit of detection and response stability. The optimized waveform allowed the sensitive and stable detection of model compounds, such as clenbuterol and caffeic acid, that showed detection limits of 0.1 μg L−1 and 14 μg L−1, quantification limits of 0.4 μg L−1 and 46 μg L−1, and linearity up to 100 μg L−1 (r = 0.9993) and 10 mg L−1 (r = 0.9998), respectively. Similar results were obtained for other compounds of the same classes, with precision values under repeatability conditions ranging from 3.0 to 5.9%. The proposed method can be then considered as an excellent alternative to the post-column detection of beta-agonists, phenols and polyphenols.  相似文献   

11.
Ultrasound-assisted emulsification microextraction with solidification of floating organic droplet (USAEME-SFO) followed by high performance liquid chromatography-diode array detection (HPLC-DAD), was applied for preconcentration and determination of phthalate esters in cosmetic and water samples. The effects of different variables on the extraction efficiency were studied simultaneously using an experimental design. The variables of interest in the USAEME-SFO were extraction solvent volume, salt effect, extraction time and centrifugation time. A factorial experimental design was employed for screening to determine the variables significantly affecting the extraction efficiency. Then, the significant factors were optimized by using a Box-Behnken design (BBD) and the response surface equations were derived. The optimum experimental conditions were extraction solvent volume, 30 μL; sodium chloride concentration, 20% (w/v); extraction time, 12 min and centrifugation time, 5 min. Under optimal conditions, the preconcentration factors were between 355 and 409. The limit of detections (LODs) ranged from 0.005 μg L−1 (for Diethylphthalate) to 0.01 μg L−1 (for Dimethylphthalate). Dynamic linear ranges; (DLRs) of 0.05-800 and 0.05-1000 μg L−1 were obtained for Diisobutyl- and Dimethylphthalate, respectively. The performance of the method was evaluated for extraction and determination of phthalate esters in cosmetic and environmental water samples in micrograms per liter and satisfactory results were obtained (RSDs < 12.6%).  相似文献   

12.
A method for determining a group of phthalate esters in pharmaceutical formulae used in parenteral nutrition samples (with and without vitamins) has been developed. The phthalic acid esters (PAEs) studied were dimethyl phthalate, diethyl phthalate, butyl benzyl phthalate, dibutyl phthalate, di-(2-ethylhexyl) phthalate, and dioctyl phthalate. This group of phthalates was determined by high performance liquid chromatography (HPLC)–electrospray ionization–mass spectrometry, working in positive ion mode. The phthalates analyzed were extracted from the sample using hexane and sodium hydroxide. The hexane was then evaporated, and the compounds were redissolved in acetonitrile. The compounds were separated by HPLC working in gradient mode with acetonitrile-ultrapure water starting from 5% to 75% acetonitrile in 5 min, followed by isocratic elution for 27 min. Standard calibration curves were linear for all the analytes over the concentration range 10–250 μg L−1. The method was precise (with RSD from 3.3% to 12.9%) and sensitive. The proposed analytical method has been applied to the analysis of these compounds in different pharmaceutical formulae (with different compositions) for parenteral nutrition samples in order to check the presence of phthalates and determine their concentration.  相似文献   

13.

The two adsorptive stripping voltammetric approaches for detection and quantitative determination of diethyl (2E)-2-{(2E)-[1-(4-methylphenyl)imidazolidin-2-ylidene]hydrazinylidene}butanedioate (DIB)—a novel molecule of medical importance—using two sensitive sensors based on modified glassy carbon electrodes as reusable sensors, were developed for the first time. The proposed electrochemical methods are based on adsorptive/reductive behaviour of DIB at two modified carbonic electrodes: a bismuth film-modified glassy carbon electrode (BiF/GCE) and a lead film-modified glassy carbon electrode (PbF/GCE). The electron gain mechanism for the electrochemical reduction of DIB on both developed sensors was proposed for the first time. To achieve the highest sensitivity in adsorptive stripping determinations, various experimental variables (e.g. the composition and pH of the supporting electrolytes, deposition conditions of bismuth and lead films, concentrations of plating solutions, accumulation times and potentials of DIB, etc.) were extensively examined. The comparison of validation parameters obtained during the determination of DIB at two sensors was presented. The excellent linear correlation was found between the monitored adsorptive stripping voltammetric peak current and the DIB concentration in the range of 15–600 μg L−1 at an accumulation time of 30 s (with LOD = 4.2 μg L−1 and LOQ = 14.0 μg L−1) using the BiF/GCE as a sensor. Furthermore, the excellent linear relationship was confirmed between the monitored adsorptive stripping voltammetric peak current and the DIB concentration in the range of 9–900 μg L−1 at an accumulation time of 10 s (with better LOD = 1.5 μg L−1 and LOQ = 5.0 μg L−1), employing the PbF/GCE as a sensor. The two optimized adsorptive stripping voltammetric approaches—as facile, sensitive, reliable and inexpensive—were successfully used as first methods for the quantitative analysis of a novel anticancer agent (DIB) in its pure pharmaceutically acceptable form. However, the practical applicability of square-wave adsorptive stripping voltammetric determination of the electroactive DIB molecule at a PbF/GCE, as the modified electrode of higher sensitivity, was presented after its successful solid phase extraction from a real serum sample.

  相似文献   

14.
Vicinal diketones, namely diacetyl (DC) and pentanedione (PN), are compounds naturally found in beer that play a key role in the definition of its aroma. In lager beer, they are responsible for off-flavors (buttery flavor) and therefore their presence and quantification is of paramount importance to beer producers. Aiming at developing an accurate quantitative monitoring scheme to follow these off-flavor compounds during beer production and in the final product, the head space solid-phase microextraction (HS-SPME) analytical procedure was tuned through experiments planned in an optimal way and the final settings were fully validated. Optimal design of experiments (O-DOE) is a computational, statistically-oriented approach for designing experiences that are most informative according to a well-defined criterion. This methodology was applied for HS-SPME optimization, leading to the following optimal extraction conditions for the quantification of VDK: use a CAR/PDMS fiber, 5 ml of samples in 20 ml vial, 5 min of pre-incubation time followed by 25 min of extraction at 30 °C, with agitation. The validation of the final analytical methodology was performed using a matrix-matched calibration, in order to minimize matrix effects. The following key features were obtained: linearity (R2 > 0.999, both for diacetyl and 2,3-pentanedione), high sensitivity (LOD of 0.92 μg L−1 and 2.80 μg L−1, and LOQ of 3.30 μg L−1 and 10.01 μg L−1, for diacetyl and 2,3-pentanedione, respectively), recoveries of approximately 100% and suitable precision (repeatability and reproducibility lower than 3% and 7.5%, respectively). The applicability of the methodology was fully confirmed through an independent analysis of several beer samples, with analyte concentrations ranging from 4 to 200 g L−1.  相似文献   

15.
Phthalates (PAEs) are ubiquitous toxic chemical compounds. During the last few years, some phthalate metabolites (MPAEs) have been proposed as appropriate biomarkers in human urine samples to determine PAE human intake and exposure. So, it is necessary to have fast, easy, robust and validated analytical methods to determine selected MPAEs in urine human samples. Two different instrumental methods based on gas (GC) and ultra-high performance liquid (UHPLC) chromatography coupled to mass spectrometry (MS) have been optimized, characterized and validated for the simultaneous determination of nine primary and secondary phthalate metabolites in urine samples. Both instrumental methods have similar sensitivity (detection limits ranged from 0.03 to 8.89 pg μL−1 and from 0.06 to 0.49 pg μL−1 in GC–MS and UHPLC–MS2, respectively), precision (repeatability, expressed as relative standard deviation, which was lower than 8.4% in both systems, except for 5OH-MEHP in the case of GC–MS) and accuracy. But some advantages of the UHPLC–MS2 method, such as more selectivity and lower time in the chromatographic runs (6.8 min vs. 28.5 min), have caused the UHPLC–MS2 method to be chosen to analyze the twenty one human urine samples from the general Spanish population. Regarding these samples, MEP showed the highest median concentration (68.6 μg L−1), followed by MiBP (23.3 μg L−1), 5cx-MEPP (22.5 μg L−1) and MBP (19.3 μg L−1). MMP (6.99 μg L−1), 5oxo-MEHP (6.15 μg L−1), 5OH-MEHP (5.30 μg L−1) and MEHP (4.40 μg L−1) showed intermediate levels. Finally, the lowest levels were found for MBzP (2.55 μg L−1). These data are within the same order of magnitude as those found in other similar populations.  相似文献   

16.
In the present work, a novel type of superparamagnetic nanosorbent, polythiophene-coated Fe3O4 nanoparticles (Fe3O4@PTh NPs), have been successfully synthesized. The synthesized NPs were characterized by scanning electron microscopy (SEM), Fourier transform-infrared (FT-IR) spectroscopy, and thermal gravimetric analysis (TGA). The synthesized Fe3O4@PTh NPs were applied as an efficient sorbent for extraction and preconcentration of several typical plasticizer compounds (di-n-butyl phthalate (DBP), di-(2-ethylhexyl) phthalate (DEHP), and dioctyl adipate (DOA)) from environmental water samples. Separation of Fe3O4@PTh NPs from the aqueous solution was simply achieved by applying external magnetic field. Separation and determination of the extracted plasticizers was performed by gas chromatography–flame ionization detection (GC–FID). Several variables affecting the extraction efficiency of the analytes i.e., amount of NPs sorbent, salt concentration, extraction time, and desorption conditions were investigated and optimized. The best working conditions were as follows: amount of sorbent, 100 mg; NaCl concentration, 30% (w/v); sample volume, 45 mL; extraction time, 10 min; and 100 μL of ethyl acetate for desorption of the analytes within 2 min. Under optimized conditions, preconcentration factors for DBP, DEHP, and DOA were obtained as 86, 194, and 213, respectively. The calibration curves were linear (R2 > 0.998) in the concentration range of 0.4–100 μg L−1 for both DEHP and DOA and 0.7–100 μg L−1 for DBP. The limits of detection (LODs) were obtained in the range of 0.2–0.4 μg L−1. The intra-day relative standard deviations (RSDs%) based on four replicates were obtained in the range of 4.0–12.3%. The proposed procedure was applied to analysis of water samples including river water, bottled mineral water, and boiling water exposed to polyethylene container (after cooling) and recoveries between 85 and 99% and RSDs lower than 12.8% were obtained.  相似文献   

17.
In the present study, a natural sorbent based micro-solid phase extraction (μ-SPE) was developed for determination of phthalate esters in milk samples. For the first time, an efficient and cost effective natural material (seed powder of Moringa oleifera) was employed as sorbent in μ-SPE. The sorbent was found to be naturally enriched with variety of functional groups and having a network of interconnected fibers. This method of extraction integrates different steps such as removal of proteins and fatty stuff, extraction and pre-concentration of target analytes into a single step. Thirteen phthalate esters were selected as target compounds for the development and evaluation of method. Some key parameters affecting the extraction efficiency were optimized, including selection of membrane, selection and amount of sorbent, extraction time, desorption solvent, volume of desorption solvent, desorption time and effect of salt addition. Under the optimum conditions, very good linearity was achieved for all the analytes with coefficient of determinations (R2) ranging between 0.9768 and 0.9977. The limits of detection ranged from 0.01 to 1.2 μg L−1. Proposed method showed satisfactory reproducibility with relative standard deviations ranging from 3.6% to 10.2% (n = 7). Finally, the developed method was applied to tetra pack and bottled milk samples for the determination of phthalate esters. The performance of natural sorbent based μ-SPE was better or comparable to the methods reported in the literature.  相似文献   

18.
A highly sensitive flow analysis system has been developed for the trace determination of reactive phosphate in natural waters, which uses a polymer inclusion membrane (PIM) with Aliquat 336 as the carrier for on-line analyte separation and preconcentration. The system operates under flow injection (FI) and continuous flow (CF) conditions. Under optimal FI conditions the system is characterised by a linear concentration range between 0.5 and 1000 μg L−1 P, a sampling rate of 10 h−1, a limit of detection of 0.5 μg L−1 P and RSDs of 3.2% (n = 10, 100 μg L−1) and 7.7% (n = 10, 10 μg L−1). Under CF conditions with 10 min stop-flow time and sample solution flow rate of 1.32 mL min−1 the flow system offers a limit of detection of 0.04 μg L−1 P, a sampling rate of 5 h−1 and an RSD of 3.4% (n = 5, 2.0 μg L−1). Interference studies revealed that anions commonly found in natural waters did not interfere when in excess of at least one order of magnitude. The flow system, operating under CF conditions, was successfully applied to the analysis of natural water samples containing concentrations of phosphate in the low μg L−1 P range, using the multipoint standard addition method.  相似文献   

19.
An Ultrasound-Vortex-Assisted Dispersive Liquid–Liquid Micro-Extraction (USVADLLME) procedure coupled with Gas Chromatography-Flame Ionization Detector (GC-FID) or Gas Chromatography-Ion Trap Mass Spectrometry (GC-IT/MS) is proposed for rapid analysis of six phthalate esters in hydroalcoholic beverages (alcohol by volume, alc vol−1, ≤40%). Under optimal conditions, the enrichment factor of the six analytes ranges from 220- to 300-fold and the recovery from 85% to 100.5%. The limit of detection (LOD) and limit of quantification (LOQ) are ≥0.022 μg L−1 and ≥0.075 μg L−1, respectively. Intra-day and inter-day precisions expressed as relative standard deviation (RSD), are ≤8.2% and ≤7.0%, respectively. The whole proposed methodology has demonstrated to be simple, reproducible and sensible for the determination of trace phthalate esters in red and white wine samples.  相似文献   

20.
In the present work, an automated on-line electrochemically controlled in-tube solid-phase microextraction (EC-in-tube SPME) coupled with HPLC-UV was developed for the selective extraction and preconcentration of indomethacin as a model analyte in biological samples. Applying an electrical potential can improve the extraction efficiency and provide more convenient manipulation of different properties of the extraction system including selectivity, clean-up, rate, and efficiency. For more enhancement of the selectivity and applicability of this method, a novel molecularly imprinted polymer coated tube was prepared and applied for extraction of indomethacin. For this purpose, nanostructured copolymer coating consisting of polypyrrole doped with ethylene glycol dimethacrylate was prepared on the inner surface of a stainless-steel tube by electrochemical synthesis. The characteristics and application of the tubes were investigated. Electron microscopy provided a cross linked porous surface and the average thickness of the MIP coating was 45 μm. Compared with the non-imprinted polymer coated tubes, the special selectivity for indomethacin was discovered with the molecularly imprinted coated tube. Moreover, stable and reproducible responses were obtained without being considerably influenced by interferences commonly existing in biological samples. Under the optimal conditions, the limits of detection were in the range of 0.07–2.0 μg L−1 in different matrices. This method showed good linearity for indomethacin in the range of 0.1–200 μg L−1, with coefficients of determination better than 0.996. The inter- and intra-assay precisions (RSD%, n = 3) were respectively in the range of 3.5–8.4% and 2.3–7.6% at three concentration levels of 7, 70 and 150 μg L−1. The results showed that the proposed method can be successfully applied for selective analysis of indomethacin in biological samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号