首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
In this work we show two different glasses-free 3D viewing systems for medical imaging: a stereoscopic system that employs a vertically dispersive holographic screen (VDHS) and a multi-autostereoscopic system, both used to produce 3D MRI/CT images. We describe how to obtain a VDHS in holographic plates optimized for this application, with field of view of 7 cm to each eye and focal length of 25 cm, showing images done with the system. We also describe a multi-autostereoscopic system, presenting how it can generate 3D medical imaging from viewpoints of a MRI or CT image, showing results of a 3D angioresonance image.  相似文献   

2.
A super-resolution imaging method using dynamic grating based on liquid-crystal spatial light modulator (SLM) is developed to improve the resolution of a digital holographic system. The one-dimensional amplitude cosine grating is loaded on the SLM, which is placed between the object and hologram plane in order to collect more high-frequency components towards CCD plane. The point spread function of the system is given to confirm the separation condition of reconstructed images for multiple diffraction orders. The simulation and experiments are carried out for a standard resolution test target as a sample, which confirms that the imaging resolution is improved from 55.7 μm to 31.3 μm compared with traditional lensless Fourier transform digital holography. The unique advantage of the proposed method is that the period of the grating can be programmably adjusted according to the separation condition.  相似文献   

3.
An active omnidirectional vision owns the advantages of the wide field of view (FOV) imaging, resulting in an entire 3D environment scene, which is promising in the field of robot navigation. However, the existing omnidirectional vision sensors based on line laser can measure points only located on the optical plane of the line laser beam, resulting in the low-resolution reconstruction. Whereas, to improve resolution, some other omnidirectional vision sensors with the capability of projecting 2D encode pattern from projector and curved mirror. However, the astigmatism property of curve mirror causes the low-accuracy reconstruction. To solve the above problems, a rotating polygon scanning mirror is used to scan the object in the vertical direction so that an entire profile of the observed scene can be obtained at high accuracy, without of astigmatism phenomenon. Then, the proposed method is calibrated by a conventional 2D checkerboard plate. The experimental results show that the measurement error of the 3D omnidirectional sensor is approximately 1 mm. Moreover, the reconstruction of objects with different shapes based on the developed sensor is also verified.  相似文献   

4.
Two different methods from graphic processing unit(GPU) and central processing unit(CPU) are proposed to suitably optimize look-up table algorithms of computer generated holography(CGH). The numerical simulations and experimental results show that we can reconstruct a good quality object. The computation of CGH for a three-dimensional(3D) dynamic holographic display can also be sped up by programming with our proposed method. It can optimize both file loading and the inline calculation process. The phase-only CGH with gigabyte data for reconstructing 10 MB object samplings is generated. In addition, the proposed method effectively reduced time costs of loading and writing offline tables on a CPU. It is believed the proposed method can provide high speed and huge data CGH for 3D dynamic holographic displays in the near future.  相似文献   

5.
Light field displays comprise three-dimensional (3D) visual information presentation devices capable of providing realistic and full parallax autostereoscopic images. In this letter, the recent advances in the light field displays based on integral imaging (II) and holographic techniques are presented. Several advanced approaches to demonstrate the light field displays including viewing angle enhancement techniques of the II display, a fast hologram generation method using graphics processing unit (GPU) and multiple WRPs, and a holographic microscopy to display the living cells are reported. These methods improve some important constraints of the light field displays and add new features.  相似文献   

6.
基于光场重构的空间三维显示技术   总被引:2,自引:0,他引:2  
刘旭  李海峰 《光学学报》2011,(9):194-198
真实空间三维显示可以通过精确再现三维物体的空间光场分布来实现.依据三维景物空间光场分布特性,提出并介绍基于光场重构的真实空间三维场景显示的基本原理与方法.实验表明,利用光场重构原理,可以运用现有的光学空间光调制器构造出比全息再现更为优越的真实三维显示.  相似文献   

7.
本文对多空间光调制器不同拼接方式拓展全息三维再现像视角的方法进行了分析,基于多片空间光调制器拼接拓展视角的思想,利用平面反射镜、分光镜和两片透射式空间光调制器设计了曲面拼接系统,进行了全息三维再现像的视角拓展实验研究。用该系统对四棱锥物体的层析菲涅尔衍射全息图进行再现,结果表明,总视角由基于单片空间光调制器的1.7°增大到3.2°,即拓展到约1.9倍,分光镜能够消除两片空间光调制器间的间隙,实现无缝拼接。该方法同样适用于更多空间光调制器的曲面拼接中,可以有效地拓展全息再现像的视场角大小。  相似文献   

8.
This paper introduces a new comprehensive procedure for both geometric and colour calibration of structured light system. In order to perform both geometric and colour calibration procedure, a new calibration artifact is proposed. The intrinsic and extrinsic parameters of projector and camera are estimated by using an extended pinhole camera model with a tangential and radial distortion. Camera image plane coordinates are obtained by extracting features from images of a calibration artifact. Projector image plane coordinates are calculated on the basis of continuous phase maps obtained from a fringe pattern phase reconstruction procedure. In order to stereo calibrate camera-projector system, pairs of corresponding image plane points are calculated with subpixel accuracy. In addition, one of three pattern views is used in colour calibration. RGB values of a colour field pattern detected by camera and their reference values are compared. This comparison leads to derivation of a colour transformation matrix. The performance of the proposed method is tested by measuring plane, sphere and distance reference. Also 360 degrees complex object 3D model from a set of measurements is obtained. Residual mean errors for all tests performed are calculated.  相似文献   

9.
Pulsed digital holographic interferometry has been used to investigate the plume and the shock wave generated in the ablation process of a Q-switched Nd-YAG (λ=1064 nm and pulse duration=12 ns) laser pulse on a polycrystalline boron nitride (PCBN) target under atmospheric air pressure. A special setup based on two synchronised wavelengths from the same laser for simultaneous processing and measurement has been used. Digital holograms were recorded for different time delays using collimated laser light (λ=532 nm) passed through the volume along the target. Numerical data of the integrated refractive index field were calculated and presented as phase maps showing the propagation of the shock wave and the plume generated by the process. Radon inversion has been used to estimate the 3D refractive index fields measured from the projections assuming rotational symmetry. The shock wave density has been calculated using the point explosion model and the shock wave condition equation and its behaviour with time at different power densities ranging from 1.4 to 9.1 GW/cm2 is presented. Shock front densities have been calculated from the reconstructed refractive index fields using the Gladstone–Dale equation. A comparison of the shock front density calculated from the reconstructed data and that calculated using the point explosion model at different time delays has been done. The comparison shows quite good agreement between the model and the experimental data. Finally the reconstructed refractive index field has been used to estimate the electron number density distribution within the laser-induced plasma. The electron number density behaviour with distance from the target at different power densities and its behaviour with time are shown. The electron number densities are found to be in the order of 1018 cm?3 and decay at a rate of 3×1015 electrons/cm3 ns.  相似文献   

10.
A new asymmetric integral imaging (AII) system for real-time pickup and three-dimensional (3-D) display of far outdoor scenes based on dynamic-pixel-mapping (DPM) is proposed. DPM is a digital process to transform the elemental images captured with a lens array into the perspective-variant object images (POIs) whose structures are matched with those of display lenses, where the orders of pixels in each POI are reversely mapped, and then capture a set of virtual elemental images (EIs) at the specific depth planes from the back-propagated POIs. This DPM enables an asymmetrical use of pickup and display lens arrays, allowing the long-ranged pickup of far outdoor scenes and their resolution-enhanced 3-D reconstruction. Experiments with a pair of pickup and display lens arrays whose pitches and focal lengths are given by 7.5 mm, 30 mm and 1.2 mm, 8 mm, respectively, show that the effective pickup-range and resolution of the proposed system have been increased up to 6 m and 1600×1600 pixels, respectively, from 0.064 m and 480×480 pixels of the conventional systems employing the same pickup and display lens arrays. In addition, experiments with an implemented test bed confirms that the proposed system can provide real-time 3-D images in 25 frames per second.  相似文献   

11.
PurposeTo determine the clinical value of routine use of thin-section 3D MRI using 3D FSE sequences with a variable flip angle technique for internal derangements of the knee joint at 3 T.Method and MaterialsThirty-four knees in 34 patients suspected of having internal derangements of the knee joint were included. Following standard 2D MRI protocol including sagittal PDWI, T1WI and T2*WI, coronal fat-suppressed PDWI, and axial fat-suppressed PDWI with 3-4 mm thicknesses, fat-suppressed and water-excitation PDWI using 3D FSE sequences with a variable flip angle technique with 0.6 mm thickness were obtained in coronal plane and the three major planes with 1 mm thickness (3D MRI) was reformatted. The standard 2D MRI protocol and reformatted 3D MRI protocol (three sagittal 2D sequence images plus 3D MRI) were independently analyzed by two radiologists concerning presence or absence of lesions in the menisci, cartilage, and ligament. Interobserver agreements in both the MRI protocols were assessed by weighted-kappa coefficients. Regarding diagnostic accuracy, areas under the receiver operating characteristic curves (Az values) of both the MRI protocols were compared.ResultsThirty-eight meniscal lesions, 39 cartilage lesions, and 20 ligamentous lesions were surgically detected. Excellent interobserver agreements (kappa = 0.91–0.98) were seen in both the MRI protocols, with a slightly better tendency in the reformatted 3D MRI protocol. Average Az values in detection of the meniscal, cartilage, and ligamentous lesions were significantly higher in the reformatted 3D MRI protocol than in the standard 2D MRI protocol (p < 0.01 or p < 0.001).ConclusionRoutine use of reformatted thin-section 3D MRI using 3D FSE sequences with a variable flip angle technique may improve diagnostic accuracy and confidence in detection of internal derangements of the knee joint.  相似文献   

12.
We propose and analyze a high effective Q-factor triangular ring resonator (TRR) coupled with an asymmetric Mach–Zehnder interferometer (AMZI), in which the long evanescent fields on a total internal reflection (TIR) mirror in the TRR and the field cancelation by the phase difference of each path in the AMZI are utilized. The TRR is employed in order to more effectively measure the quantities that occur during biological events because the evanescent field of the TIR mirror with its sharp incident angle is influenced by the Goos–Hänchen shift. In this paper, we report upon the AMZI-coupled TRR sensor structure with the high effective Q-factor of about 105 obtained through the optimization of the AMZI path-length. The sensitivity of the resonance shift when changing the refractive index of 1 × 10? 4 at the incidence angle of 22.92° has been identified to be as high as 0.48 × 104 nm/RIU. In addition, the power sensitivity of the AMZI-coupled TRR with a 17 dB attenuation is 5.7 × 105 dB/RIU.  相似文献   

13.
An experimental study on beam dynamics in MIRRORCLE-20, a tabletop storage ring of 15 cm orbit radius, was performed. Measurement of the infrared (IR) synchrotron light is the tool of this study. The IR emission is enhanced by a circular optics, named photon storage ring (PhSR), placed around the electron orbit, and is collected by a magic mirror associated with two plane mirrors in the storage ring. The measured average IR power in mid-IR region (λ < 50 μm) is ~59 mW. The observed stored beam current is about 1.2 A at maximum, which represents a record for a storage ring. The observed beam size is about 74 × 3 mm2. We conclude that this very long beam size is due to the large betatron oscillation of 2/3 resonance injection.  相似文献   

14.
PurposeTo present a method that uses a novel free-running self-gated acquisition to achieve isotropic resolution in whole heart 3D Cartesian cardiac CINE MRI.Material and methods3D cardiac CINE MRI using navigator gating results in long acquisition times. Recently, several frameworks based on self-gated non-Cartesian trajectories have been proposed to accelerate this acquisition. However, non-Cartesian reconstructions are computationally expensive due to gridding, particularly in 3D. In this work, we propose a novel highly efficient self-gated Cartesian approach for 3D cardiac CINE MRI. Acquisition is performed using CArtesian trajectory with Spiral PRofile ordering and Tiny golden angle step for eddy current reduction (so called here CASPR-Tiger). Data is acquired continuously under free breathing (retrospective ECG gating, no preparation pulses interruption) for 4–5 min and 4D whole-heart volumes (3D + cardiac phases) with isotropic spatial resolution are reconstructed from all available data using a soft gating technique combined with temporal total variation (TV) constrained iterative SENSE reconstruction.ResultsFor data acquired on eight healthy subjects and three patients, the reconstructed images using the proposed method had good contrast and spatio-temporal variations, correctly recovering diastolic and systolic cardiac phases. Non-significant differences (P > 0.05) were observed in cardiac functional measurements obtained with proposed 3D approach and gold standard 2D multi-slice breath-hold acquisition.ConclusionThe proposed approach enables isotropic 3D whole heart Cartesian cardiac CINE MRI in 4 to 5 min free breathing acquisition.  相似文献   

15.
邓丽军  王辉  马利红 《光子学报》2014,39(12):2168-2173
为提高数字全息再现像视角,提出一种基于滤波成像的数字全息技术来实现大视角的三维物体面型测量.利用离轴像面数字全息技术,通过在4F相干图像处理系统的空间频谱面处放置可移动的低通滤波器,使满足CCD分辨率的物光波与参考光波干涉形成全息图,并控制低通滤波及成像区域分别记录不同谱段的子全息图.再现时,首先对子全息图进行数字傅里叶变换,重构对应频谱段,并对频谱段进行拼接形成完整的物光频谱|而后通过数字再现获得大视角的数字全息再现像.利用该方法测量了圆柱形表面(光滑的缝纫针)的三维形貌,并取得了较好的实验结果.  相似文献   

16.
Hongyuan Wen 《Optik》2012,123(1):34-39
Aiming at the present situation of the panoramic target detection field, one laser target panoramic optical system on finite size is designed. The laser transmission optical system proposes a partition beam layout method, namely 360° omnidirectional detection can be realized by 6 fan-shaped light beams with 60° × 1° field angle. The receiving system position and size can be determined based on calculation the transformation of the Gaussian beam through the lens. After the computing and optimizing the lens curvature radius and other optical parameters, the integrated design of the transmission and receiving optical system is completed. The system echo signal experiment is carried out, and the experimental results show the error of the actual value and theoretical value is less than 4.8%. The system works stably and the anticipated design effect is achieved.  相似文献   

17.
This paper puts forward a novel fast algorithm of three-dimensional Computer-Generated Hologram (CGH). The algorithm proposed can directly express the two-dimensional Fourier spectrum of a unit square by an analytic function, as well as the light field distribution of the unit square on the holographic plane (the unit square is not parallel to the holographic plane). The computer simulation and photoelectric reconstruction are also performed to verify the algorithm. The experimental results show that the algorithm is quick and simple, providing a good reference to research on three-dimensional CGH.  相似文献   

18.
动态全息三维显示研究最新进展   总被引:2,自引:0,他引:2       下载免费PDF全文
曾超  高洪跃  刘吉成  于瀛洁  姚秋香  刘攀  郑华东  曾震湘 《物理学报》2015,64(12):124215-124215
全息三维显示是真三维显示技术, 其原理是利用光学干涉记录和衍射再现将物体或场景的三维信息全部重建出来, 所以观看全息三维图像与观看真实物体或场景的效果一样. 近期全息研究领域有一些突破性的成果被报道, 将推动全息显示的应用不断走向成熟. 本文将重点介绍基于光学材料和空间光调制器为全息图承载载体的动态全息三维显示最新发展状况. 虽然动态全息三维显示研究仍然存在挑战, 但最近研究中已经利用光学材料实现了实时动态全息三维视频显示, 这为未来实现大尺寸、高分辨率、彩色全息真三维视频显示提供了可能.  相似文献   

19.
Calibration for stereo vision system plays an important role in the field of machine vision applications. The existing accurate calibration methods are usually carried out by capturing a high-accuracy calibration target with the same size as the measurement view. In in-situ 3D measurement and in large field of view measurement, the extrinsic parameters of the system usually need to be calibrated in real-time. Furthermore, the large high-accuracy calibration target in the field is a big challenge for manufacturing. Therefore, an accurate and rapid calibration method in the in-situ measurement is needed. In this paper, a novel calibration method for stereo vision system is proposed based on phase-based matching method and the bundle adjustment algorithm. As the camera is usually mechanically locked once adjusted appropriately after calibrated in lab, the intrinsic parameters are usually stable. We emphasize on the extrinsic parameters calibration in the measurement field. Firstly, the matching method based on heterodyne multi-frequency phase-shifting technique is applied to find thousands of pairs of corresponding points between images of two cameras. The large amount of pairs of corresponding points can help improve the accuracy of the calibration. Then the method of bundle adjustment in photogrammetry is used to optimize the extrinsic parameters and the 3D coordinates of the measured objects. Finally, the quantity traceability is carried out to transform the optimized extrinsic parameters from the 3D metric coordinate system into Euclid coordinate system to obtain the ultimate optimal extrinsic parameters. Experiment results show that the procedure of calibration takes less than 3 s. And, based on the stereo vision system calibrated by the proposed method, the measurement RMS (Root Mean Square) error can reach 0.025 mm when measuring the calibrated gauge with nominal length of 999.576 mm.  相似文献   

20.
Recent years, the design of photonic crystal (PC) based optical devices is receiving keen interest in research and scientific community. In this paper, two dimensional (2D) PC based eight channel demultiplexer is proposed and designed and the functional characteristics of demultiplexer namely resonant wavelength, transmission efficiency, quality factor, spectral width, channel spacing and crosstalk are investigated. The demultiplexer is designed to drop the wavelength centred at 1537.6 nm, 1538.5 nm, 1539.4 nm, 1540.4 nm, 1541.2 nm, 1541.9 nm, 1542.6 nm and 1543.1 nm. The proposed demultiplexer is primarily composed of bus waveguide, drop waveguide and quasi square ring resonator. The quasi square ring resonator and square ring micro cavity (inner rods) are playing a vital role for a desired channel selection. The operating range of the devices is identified through a photonic band gap (PBG) which is obtained using a plane wave expansion (PWE) method. The functional characteristics of the proposed demultiplexer are attained using a 2D finite difference time domain (FDTD) method. The proposed device offers low crosstalk and high transmission efficiency with ultra-compact size, hence, it is highly desirable for DWDM applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号