首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 78 毫秒
1.
分子印迹聚合物修饰电化学晶体管检测抗坏血酸分子   总被引:1,自引:0,他引:1  
以抗坏血酸(AA)为模板分子、邻苯二胺(o-PD)为功能单体,在金电极表面电聚合制备分子印迹聚合物膜(MIP),并以该MIP修饰的电极为栅极制备了具有高选择性、高灵敏度的AA电化学晶体管(OECT)传感器件。应用循环伏安法(CV)、交流阻抗法(EIS)对分子印迹聚合物电极进行一系列的表征与检测。实验结果表明:以pH=5.2,浓度为0.2mol/L HAc-NaAc(体积比2.1∶7.9)的缓冲液为背景溶液,o-PD与AA的物质的量之比为1∶2,以0.5V/s的扫描速率在0~0.8V内扫描20圈,所得分子印迹膜电极性能最佳。应用以该分子印迹修饰电极作为栅极的电化学晶体管检测AA,得到AA浓度的检测限为0.3μmol/L,沟道电流与AA浓度在0.3~3μmol/L(低浓度)与3~100μmol/L(高浓度)这2个范围内成线性关系。  相似文献   

2.
以邻苯二胺为功能单体,扑热息痛为模板,采用循环伏安法在玻碳电极表面电聚合形成邻苯二胺电聚合膜,经无水乙醇将模板分子洗脱,制得扑热息痛分子印迹膜电极.通过方波伏安法研究此印迹传感器的分析性能,建立了以K3[Fe(CN)6]为活性电子探针的间接分析法.实验表明,该传感器具有高选择性和灵敏度.在2.0×10-6 ~8.0×1...  相似文献   

3.
基于分子印迹技术,以硫酸链霉素(STR)为模板分子,邻苯二胺(OPD)为功能单体,通过循环伏安电聚合在玻碳电极表面构建出对STR具有选择特异性的电化学传感器,且制备过程中STR无需衍生处理。以K3[Fe(CN)6]为探针的方波伏安(SWV)分析,模板分子与单体的摩尔配比为1∶4、洗脱溶剂为70%乙醇溶液,在此条件下制备的传感器性能良好。传感器得到的方波伏安峰电流变化值与硫酸链霉素浓度在2.5×10!8~1.2×10!6mol/L范围内线性关系较好,检出限为1.2×10!8mol/L,基于蜂蜜样品的测定中链霉素回收率介于102.1%~119.2%之间。  相似文献   

4.
以水杨酸(SA)为模板分子,邻苯二胺(o-PPD)及吡咯(Py)为复合功能单体,在石墨烯修饰的玻碳电极表面制备分子印迹电化学传感器(MIP/GO/GCE),用扫描电镜(SEM)观察印迹膜的表面形貌,方波伏安法(SWV)和循环伏安法(CV)对分子印迹传感器的性能进行表征。通过优化实验条件,显示SA浓度在1.0×10-8~1.0×10-2 mol/L范围内,分子印迹传感器峰电流与SA浓度负对数具有良好的线性关系,检出限为8.6×10-9 mol/L。该传感器对SA具有良好的选择性,样品回收率为101%~106%,相对标准偏差(RSD)为3.8%。SA分子印迹传感器的制备简单、抗干扰性好、灵敏度高、成本低廉,具有较好实用价值。  相似文献   

5.
以鬼臼毒素(Podophyllotoxin,PPT)为模板,甲基丙烯酸(Methacrylic acid,MAA)为功能单体,乙二醇二甲基丙烯酸酯(Ethyleneglycol dimethacrylate,EGDMA)为交联剂,固定PPT,MAA和EGDMA的摩尔比为1∶2∶100,采用原位聚合法,以甲醇-乙酸(1∶1,V/V)为洗脱剂,制得鬼臼毒素分子印迹电化学传感器(PPT molecularly imprinted electrochemical sensor,PPT-MIECS),并用循环伏安及交流阻抗法表征了其性能。在优化条件下,此传感器检测PPT的线性范围为1.0~120$mol/L,检出限为0.47$mol/L,将其用于桃儿七和人血清样品中PPT的检测,相对标准偏差小于4.0%,加标回收率在95.0%%103.3%之间。  相似文献   

6.
以孔雀石绿(MG)为模板分子,通过电聚合邻苯二胺,在多孔碳纳米纤维(PCNF)修饰的玻碳电极表面制备了可特异性识别MG的分子印迹传感器。采用差分脉冲伏安法(DPV)、循环伏安法(CV)和电化学阻抗法(EIS)表征了传感器的电化学性能,优化了PCNF的滴涂量、模板分子与功能单体的摩尔比、CV扫描圈数、洗脱剂、洗脱时间、样品溶液pH值及孵化时间等实验参数。在最佳条件下,DPV峰电流强度与MG浓度在0.10~10.0 nmol/L范围内呈良好的线性关系,检出限为0.042 nmol/L(3S/k)。此传感器具有良好的选择性、重现性和稳定性。将本方法应用于市售新鲜草鱼及养殖水样品中MG的含量测定,加标回收率为82.0%~96.5%。  相似文献   

7.
分子印迹电化学传感器能够选择性识别并检测特定目标化合物,因其设计简单、灵敏度高、价格低廉、携带方便、易于微型化和自动化等优点,在临床诊断、环境监测、食品分析等方面越来越受到人们的关注.本文作者主要论述分子印迹技术与电化学技术相结合构建分子印迹电化学传感器,包括分子印迹电化学传感器的种类,以及电化学方法制备分子印迹聚合物膜的常用单体等.对分子印迹电化学传感器领域新出现的分子印迹聚合物-纳米材料复合物以及纳米结构分子印迹聚合物也一并做了评述.  相似文献   

8.
以氨基脲(SEM)为模板分子,邻苯二胺为功能单体,在0.1 mol/L NaAc-HAc缓冲液(pH 5.2)中,通过电聚合法制备分子印迹传感器.采用循环伏安法(CV)、差分脉冲法(DPV)、电化学阻抗谱(EIS)和扫描电镜表征了此分子印迹传感器的识别性能和表面形貌.结果表明,此传感器具有粗糙、多孔的形貌,对SEM具有良好的选择性识别.在0.5 mol/L KCl-0.005 mol/L K3[Fe(CN)6]溶液中,采用DPV方法考察了功能单体与模板分子的摩尔比、模板洗脱剂、洗脱时间和温育时间对传感器响应的影响.优化后的实验条件为:功能单体与模板分子的摩尔比1:2,洗脱液为0.2 mol/L NaOH,洗脱时间15 min,温育时间12 min.在优化的实验条件下,传感器的DPV峰电流差值与SEM的浓度在3.75~ 188 ng/L范围呈良好的线性关系,检出限为1.5 ng/L(S/N=3).将此传感器应用于市售新鲜虾肌肉及受污染虾肌肉中SEM含量测定,加标回收率为80%~97%.  相似文献   

9.
基于分子印迹膜修饰丝网印刷电极的地西泮电化学传感器   总被引:2,自引:1,他引:2  
以地西泮为模板分子,采用循环伏安法在一次性丝网印刷电极表面原位电聚合形成聚邻苯二胺膜,洗脱除去模板分子后得到地西泮分子印迹膜修饰丝网印刷电极。利用差示脉冲法对印迹膜和非印迹膜进行评价,表征了电极表面膜的电化学性质。以KI为印迹电极和底液间的探针,建立了一种间接检测地西泮的传感方法。该传感器的敏感元件为修饰有分子印迹膜的丝网印刷电极,其制备和更换非常方便。用于电化学检测时,样品的富集时间为3min,地西泮的浓度在2.0×10-7~1.0×10-5mol/L范围内与峰电流呈良好的线性关系,检出限为2.5×10-8mol/L,基于猪肉样品的加标回收率为92%~95%。将该传感器初步用于实际样品分析,结果满意。  相似文献   

10.
11.
分子印迹电化学传感器敏感膜体系的构建及其研究进展   总被引:1,自引:0,他引:1  
分子印迹技术具有构效预定性、特异识别性和广泛应用性的特点,在色谱分离、固相萃取、仿生传感器、模拟酶催化和膜分离等方面得到了广泛应用。近年来,分子印迹电化学传感器(MIECS)的研究日益受到人们的重视。在MIECS设计过程中,分子印迹敏感膜体系的构建非常关键,它直接影响着传感器的性能。该文简要介绍了MIECS的分类及其检测原理,对传统体系、自组装体系、分子印迹聚合物粒子镶嵌体系、电聚合体系和溶胶-凝胶体系等5种MIECS敏感膜体系的构建方法、特点及其研究进展进行综述,并展望了MIECS的发展方向。  相似文献   

12.
In this review, the applications of molecularly imprinted polymer (MIP) materials in the area of electrochemical sensors have been explored. The designs of the MIPs containing different polymers, their preparation and their immobilization on the transducer surface have been discussed. Further, the employment of various transducers containing the MIPs based on different electrochemical techniques for determining analytes has been assessed. In addition, the general protocols for getting the electrochemical signal based on the binding ability of analyte with the MIPs have been given. The review ends with describing scope and limitations of the above electrochemical based MIP sensors.  相似文献   

13.
Detection of relevant contaminants using screening approaches is a key issue to ensure food safety and respect for the regulatory limits established. Electrochemical sensors present several advantages such as rapidity; ease of use; possibility of on-site analysis and low cost. The lack of selectivity for electrochemical sensors working in complex samples as food may be overcome by coupling them with molecularly imprinted polymers (MIPs). MIPs are synthetic materials that mimic biological receptors and are produced by the polymerization of functional monomers in presence of a target analyte. This paper critically reviews and discusses the recent progress in MIP-based electrochemical sensors for food safety. A brief introduction on MIPs and electrochemical sensors is given; followed by a discussion of the recent achievements for various MIPs-based electrochemical sensors for food contaminants analysis. Both electropolymerization and chemical synthesis of MIP-based electrochemical sensing are discussed as well as the relevant applications of MIPs used in sample preparation and then coupled to electrochemical analysis. Future perspectives and challenges have been eventually given.  相似文献   

14.
异丙隆分子印迹敏感膜传感器   总被引:7,自引:2,他引:5  
在弱酸(pH 5.5)条件下,采用电聚合法在金电极上制备邻氨基酚异丙隆分子印迹膜,对该印迹膜的性能、分子印迹效应和印迹膜对模板分子及其结构相似物的选择性响应等进行了研究.以K3Fe(CN)6为印迹电极和底液间的探针,建立了一种检测异丙隆的方法.该传感器对异丙隆具有良好的选择性和敏感度,异丙隆浓度在1.0×10-7~4.0×10-4 mol/L范围内与K3Fe(CN)6还原峰电流减少量呈线性关系; 检出限为2.95×10-8 mol/L.对农田水中异丙隆含量进行了测定,回收率为99.0%~102.0%.  相似文献   

15.
对羟基苯甲酸酯分子印迹电化学传感器的研制   总被引:3,自引:2,他引:3  
利用分子印迹技术,以对羟基苯甲酸乙酯为模板分子,甲基丙烯酸为单体,在玻碳电极表面原位聚合分子印迹聚合物敏感膜.采用方波伏安法对对羟基苯甲酸乙酯在该印迹电极上的电化学行为进行了研究,当响应时间为15 min时,0.95 V(vs SCE)处的峰电流与对羟基苯甲酸乙酯的浓度在2.0×10-6 ~2.0×10-4 mol/L范围内呈线性关系,检出限(S/N=3)为1.0 μmol/L,而相同条件下,对羟基苯甲酸乙酯在控制电极上的响应非常小并对浓度变化不灵敏;同时在印迹电极上氧化峰电位较在裸电极上发生了微弱正移.同一支印迹电极对对羟基苯甲酸乙酯响应值的RSD为4.3%(n=10).该印迹电极对尼泊金酯类具有良好的选择性,对对羟基苯甲酸甲酯、丙酯以及丁酯的选择性系数分别为1.89、1.70和2.01;对结构相似的苯酚、对羟基苯甲酸、对氨基苯甲酸等响应不灵敏,对结构差异较大的如维生素C等几乎无响应.用该分子印迹电极对实际样品进行分析,加标回收率大于90%.  相似文献   

16.
以吡咯(Py)为功能单体,草甘膦(Gly)为模板,采用电化学聚合法构建了草甘膦分子印迹电化学传感器。通过循环伏安法(CV)、差分脉冲伏安法(DPV)、电化学交流阻抗法(EIS)对印迹电极性能进行了表征,筛选了印迹电极的聚合体系和模板分子的洗脱方法,优化了检测体系的p H值和吸附时间等。结果表明,以铁氰化钾为电活性探针,在最优检测体系中该印迹传感器对草甘膦具有特异性快速响应、灵敏度高和稳定性好的优点,传感器的峰电流与草甘膦浓度在5~800 ng/m L范围内呈良好的线性关系,相关系数(r2)为0.981 7,检出限(S/N=3)为0.27 ng/m L。该传感器具有良好的重现性和稳定性,放置3周后对目标物的响应峰电流无明显变化。用于实际样品中草甘膦的测定,加标回收率为78.6%~99.0%,能满足现场快速检测的要求。  相似文献   

17.
分子印迹电化学传感器的研究进展   总被引:1,自引:0,他引:1  
本文综述了分子印迹电化学传感器的制备及其在电分析化学领域中的应用研究。引用文献83篇。  相似文献   

18.
李建平  李玉平  魏小平 《化学学报》2012,70(17):1853-1857
以三聚氰胺(MA)作为功能单体, 制备了一种检测环境中农药残留绿麦隆(CH)的分子印迹膜电化学传感器. 基于CH与辣根过氧化物酶(HRP)标记绿麦隆(HRP-CH)的竞争反应实现对CH的检测. 利用聚三聚氰胺膜(PMA)和HRP对过氧化氢的催化效应产生的双放大效应有效地提高传感器检测的灵敏度. 采用计时电流法测量, CH浓度与峰电流差值在0.01~0.8 μmol/L范围内呈现良好的线性关系, 检出限为2.64 nmol/L. 传感器对CH具有很好的选择识别性能.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏