首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
High-performance liquid chromatography method for the determination of propofol has been developed and validated. Following a liquid extraction using ethyl acetate and hexane, samples were separated by reverse-phase high-performance liquid chromatography on an XBridge C(18) column and quantified using fluorescence detection at an excitation of 276 nm and an emission of 310 nm. The mobile phase was a mixture of water (pH 4.0) and acetonitrile, with a flow rate of 1.5 mL/min. The standard curve ranged from 5-2000 ng/mL. Intra- and inter-assay variability for propofol was less than 10%, and the average recovery was greater than 95%. This assay is suitable for use in pharmacokinetic studies.  相似文献   

2.
反相高效液相色谱法测定玉米中玉米赤霉烯酮   总被引:5,自引:0,他引:5  
建立了反相高效液相色谱法检测玉米中玉米赤霉烯酮的分析方法.该方法的标准曲线回归方程为y=2.97×103 5.23×104ρ(r=0.9998);玉米样品3个水平的加标回收率分别为84.8%,86.7%和89.2%;相对标准偏差分别为4.0%,5.2%和4.4%;加标浓度为50 ng/g的玉米样品日内相对标准偏差为0.69%;玉米样品日间相对标准偏差为2.6%;方法检出限为3.0 ng/g.  相似文献   

3.
Efficient methods are needed for analysis of veterinary drug residues in food. A number of methods are available for single analytes. Multiresidue methods are now increasingly available. It is still rare, however, to find methods not involving mass spectrometry which allow for analysis of more than one class of drug residue. An efficient multiresidue method for the simultaneous determination of fluoroquinolones (FQs) and tetracyclines (TCs) in catfish muscle has now been developed. This method involves an extraction of the analytes with a mixture of acetonitrile and citrate buffer containing magnesium chloride. After centrifugation and evaporation of the supernatants, the residues are determined using high performance liquid chromatography with fluorescence detection. With this method, five fluoroquinolones and three tetracyclines were determined in fortified catfish muscle at levels of 20, 50, and 100 ng g(-1). Average recoveries for ciprofloxacin (CIP), sarafloxacin (SAR), danofloxacin (DANO), enrofloxacin (ENRO), difloxacin (DIF), oxytetracycline (OTC), tetracycline (TC), and chlortetracycline (CTC) were in the range of 60-92% with good relative standard deviations. The limits of quantitation ranged from 0.15 to 1.5 ng g(-1). Utilization of the method to successfully analyze catfish muscle samples incurred with enrofloxacin and with oxytetracycline is described.  相似文献   

4.
A simple and rapid HPLC method with UV and fluorescence detection (FLD) for the separation of ten phenolic compounds including gallic acid, catechin, epicatechin, caffeic acid, coumaric, trans-piceid, cis-piceid, trans-resveratrol, cis-resveratrol and quercetin is reported. The UV and fluorescence detector in series provided a high selectivity for the determination of these compounds. Precisions, recoveries and LODs achieved for all the analytes were satisfactory. The proposed method was applied to the determination of these compounds in commercially available red wines.  相似文献   

5.
An analytical method has been developed for the simultaneous determination of the following endectocide drugs in milk: ivermectin, abamectin, doramectin, moxidectin, eprinomectin, emamectin and nemadectin. Samples were extracted with acetonitrile, purified with solid-phase extraction on a reversed phase C8, derivatised with N-methylimidazole, trifluoroacetic anhydride and acetic acid to a stable fluorescent derivative, and were further analysed by gradient high performance liquid chromatography (HPLC) on an endcapped reversed phase Supelcosil LC-8-DB. The derivatisation step was mathematically optimised and the method was validated according to the requirements of Commission Decision 2002/657/EC, using fortified raw bovine milk. Mean recovery was between 78 and 98%. The repeatability (CVr) and within-laboratory reproducibility (CVW) ranged from 4.6 to 13.4% and from 6.6 to 14.5%, respectively. Decision limits (CCα) for analytes with MRL values, namely eprinomectin and moxidectin, were determined to be 24.8 and 50.6 μg kg−1, respectively. CCα values for unauthorised endectocides ranged from 0.1 to 0.2 μg kg−1. Due to high acceptability regarding the required criteria and applicability to ovine and caprine milk, giving similar results, this multi-analyte method has been successfully implemented in pharmacokinetic research studies as well as statutory residue monitoring in Slovenia.  相似文献   

6.
Two complementary methods were optimized for the separation and detection of trace levels of hydrogen peroxide. The first method utilized reversed-phase high-performance liquid chromatography with fluorescence detection (HPLC-FD). With this approach, hydrogen peroxide was detected based upon its participation in the hemin-catalyzed oxidation of p-hydroxyphenylacetic acid to yield the fluorescent dimer. The second method utilized high performance liquid chromatography with electrochemical detection (HPLC-ED). With this approach, hydrogen peroxide was detected based upon its oxidation at a gold working electrode at an applied potential of 400 mV vs. hydrogen reference electrode (Pd/H(2)). Both methods were linear across the range of 15-300 μM, and the electrochemical method was linear across a wider range of 7.4-15,000 μM. The limit of detection for hydrogen peroxide was 6 μM by HPLC/FD, and 0.6 μM by HPLC/ED. A series of organic peroxides and inorganic ions were evaluated for their potential to interfere with the detection of hydrogen peroxide. Studies investigating the recovery of hydrogen peroxide with three different extraction protocols were also performed. Post-blast debris from the detonation of a mixture of concentrated hydrogen peroxide with nitromethane was analyzed on both systems. Hydrogen peroxide residues were successfully detected on this post-blast debris.  相似文献   

7.
A high performance liquid chromatographic method for the analysis of chlortetracycline (CTC) using postcolumn fluorescence detection has been developed. After chromatographic separation of CTC on a polystyrene-divinylbenzene copolymer column, a highly fluorescent derivative isochlortetracycline (iso-CTC) was formed postcolumn in an on-line reaction coil with the addition of 25% NaOH (w/v). Chromatographic separation was achieved on a PRP-1 column, 15 cm x 4.6 mm, with 27:73 acetonitrile:0.2% perchloric acid (v/v), at 1.0 mL/min. Fluorescence derivatization was achieved by the on-line addition of 25% NaOH (w/v), at a flow rate of 0.2 mL/min, into the column eluant in a post-column reaction coil. The reaction coil was 9 m of teflon (1/16 in o.d., 0.3 mm i.d.) knitted into a six-sided coil. The fluorescent derivative was detected at lambda ex 355 nm and lambda em > 389 nm. Using this method after a simple sample cleanup, CTC can be detected in milk at 0.04 micrograms/mL, which is comparable to that obtained by microbiological assays. The detection method was linear between 0.02 micrograms/mL and 4 micrograms/mL. Because of the chromatographic separation, the method is more selective than microbiological assays and more sensitive than ultraviolet detection. With the chromatographic system described, the keto tautomeric forms of CTC and 4-epi-CTC are separated in a system which minimizes their formation on-column. In acidic aqueous organic solutions, the keto tautomer of CTC is the only product formed to any significant amount.  相似文献   

8.
Atrasentan is an endothelin antagonist selective for the ET(A) receptor in development at Abbott Laboratories for the treatment of cardiovascular disease and cell proliferation disorders. A simple and sensitive chromatographic method for the determination of atrasentan in human plasma has been developed and validated. The analytical method involves acidification of the plasma samples with 0.3 N HCl prior to extraction with 1:1 (v:v) hexane/tert-butylmethylether. The organic extract was evaporated to dryness, reconstituted with 20:80 (v:v) acetonitrile/0.05 M K(2)HPO(4) and washed with 75:25 (v:v) hexane/tert-butylmethylether. The organic layer was discarded and the aqueous layer was injected into the HPLC. Atrasentan and internal standard (ABT-790) were separated from interference using a 250 x 4.6 mm, 5 microm, 120 A Phenomenex Spherisorb C(8) analytical column with a 50 x 4.6 mm, Alltech Absorbosphere 5 microm CN guard cartridge using a mobile phase consisting of 25:15:5:55 (v:v:v:v) acetonitrile/isopropanol/methanol/0.05 M K(2)HPO(4), pH 7.0, at a flow rate of 1.0 mL/min. Fluorescence detection was achieved using lambda(ex) 278 nm and lambda(em) 322 nm. For a 1.0 mL plasma sample volume, the limit of quantitation was approximately 200 pg/mL. The method was linear from 0.2 to 1300 ng/mL (r(2) = 0.9986). Inter- and intra-day assay RSD (n = 6) were less than 10%. Mean accuracy determinations showed the quality control samples to range between 94 and 99% of the theoretical concentration.  相似文献   

9.
Li HP  Li JH  Li GC  Jen JF 《Talanta》2004,63(3):547-553
A high performance liquid chromatography with fluorescence (HPLC-F) detector was examined to simultaneous determination of airborne carbamates in the workplace of manufactory. The OVS-2 air sampling tube filled with glass fiber filter or quartz fiber and combined filter/XAD-2 were evaluated to collect nine commonly used carbamates (Carbofuran, Isoprocarb, Methomyl, Metolcarb, Thiodicarb, Carbaryl, Oxamyl, Methiocarb, and Prpoxur) from the air of manufactory in high humidity country. After being extracted with acetonitrile from sampling tubes, the carbamates were determined by high performance liquid chromatography with fluorescence detection posterior to on-line derivatization. The collection of carbamates and the recovery of extraction from glass wool fiber in several concentration levels, and from quartz filter were evaluated. The storage stability of carbamates was also tested. Results indicated that the HPLC-fluorescence method offers satisfactory resolution and sensitivity in carbamate analysis. With the glass fiber filter and combined filter/XAD-2, the Carbofuran, Isoprocarb, Methomyl, Metolcarb, and Thiodicarb were stable for a 28-day storage test, Carbaryl and Oxamyl for 14 days, and Methiocarb and Prpoxur for 7 days. All of these pesticides were with detection limit of 3 μg m−3. It is suited for environmental monitoring. The airborne carbamates in different areas of the manufactory were measured.  相似文献   

10.
A sensitive, simple and reproducible high performance liquid chromatographic method for detecting and quantifying albuterol in guinea pig serum is described. A structurally related compound, bamethan, was used as an internal standard. The method employs ion-pair extraction with di(2-ethylhexyl)phosphate followed by chromatography on a Zorbax SB C18 reversed-phase column. Fluorescence detection was used to identify the compounds of interest. The calibration curve was linear between 1 and 50 ng/mL albuterol hemisulfate salt (0.83 and 41.50 ng/mL albuterol base), and the limit of detection for a 1 mL sample was 1 ng/mL albuterol hemisulfate salt (0.83 ng/mL albuterol base). Serum levels of albuterol were quantified from guinea pigs that had received the drug by continuous subcutaneous infusion at a dose of 0.2 mg/kg/day for 1, 5 or 10 days, or 10 days followed by a 24 h washout period.  相似文献   

11.
建立了甘蓝和蘑菇中甲氨基阿维菌素苯甲酸盐的固相萃取-高效液相色谱荧光分析方法。蔬菜样品用乙酸乙酯提取,提取液旋转浓缩近干后用少量乙酸乙酯溶解,再经PRS固相萃取(SPE)柱净化,洗脱液经氮气吹干后用氮甲基咪唑和三氟乙酸酐衍生,衍生物用高效液相色谱分析,采用外标法定量。在添加浓度1.0~20.0 μg/kg范围内,平均添加回收率为78.6%~84.9%,日内相对标准偏差(RSD)为2.7%~6.0%,日间RSD为3.1%~8.9%,检出限为0.10 μg/kg。甲氨基阿维菌素苯甲酸盐衍生物在0.002~0.10 mg/L范围内呈良好的线性关系,相关系数为0.9999。  相似文献   

12.
建立测定药物中氯乙酰氯含量的高效液相色谱–荧光检测方法。以吖啶酮乙酰肼为荧光标记试剂,对氯乙酰氯进行柱前衍生。在室温下反应15 min,衍生产率达到最大。衍生溶液在XDB–C18柱上,以水和乙腈为流动相进行分析,激发波长和发射波长分别为255 nm和429 nm。氯乙酰氯浓度在1~1 000 nmol/L范围内与色谱峰面积具有良好的线性关系,线性相关系数r=0.999 9。方法的检出限为0.35 nmol/L,仪器精密度和方法精密度分别为0.52%和0.67%(n=6)。样品加标回收率为92.5%~95.6%。该方法简单、准确,精密度良好,可用于测定药物中氯乙酰氯的残留量。  相似文献   

13.
A rapid sensitive and selective isocratic technique was developed for the analysis of plasma epirubicin and three of its known fluorescent metabolites epirubicinol, 4'-O-beta-D-glucuronyl-4'-epidoxorubicin and 4'-O-beta-D-glucuronyl 1,3-dihydro-4'-epidoxorubicin, with daunorubicin as an internal standard, by using high performance liquid chromatography (HPLC) with fluorescence detection and a 'Hypersil ODS' column. The drugs were easily and efficiently extracted with a Sep-Pak C18 cartridge and the mean recoveries were greater than 85%. Intraassay and Interassay coefficients of variation (plasma samples) were better than 8.25%. An example of pharmacokinetic study obtained in a cancer patient after intravenous injection of epirubicine is described.  相似文献   

14.
高效液相色谱-荧光检测法测定环境水中的苯胺和苯酚   总被引:9,自引:0,他引:9  
建立了用高效液相色谱荧光检测法同时测定环境水中苯胺和苯酚的分析方法。色谱柱为EclipseXDB C8(4.6mmi.d.×150mm,5μm),流动相为甲醇 磷酸盐缓冲液(0.1mol/L磷酸二氢钾 0 1mol/L磷酸氢二钠,pH6.87)V(甲醇)∶V(磷酸盐缓冲液)=50∶50,流速1 0mL/min,柱温25℃,检测波长0minλex/λem=230/340nm(测定苯胺),3.5minλex/λem=215/300nm(测定苯酚)。测定苯胺的线性范围0.2~120ng,r=0.9999,检出限0.01ng;测定苯酚的线性范围0.4~500ng,r=0.9998,检出限0.02ng,回收率98.1%~101.2%。该方法已用于对环境水中苯胺和苯酚的测定。  相似文献   

15.
建立了柑橘、苹果、菠菜、西红柿等水果和蔬菜中乙萘酚的高效液相色谱-荧光快速检测方法。样品用乙腈提取,浓缩,乙腈-甲苯(3:1,V/V)溶解后经LC-NH2固相萃取柱净化;色谱柱:Pickering C18(250 mm×4.6 mm,5μm);流动相:乙腈-水(50:50,V/V);检测波长:λex=250 nm,λem=410 nm。乙萘酚在0.20~50.00 mg/L范围内线性关系良好(r=0.9999);在0.05,0.10,0.50 mg/kg 3个添加水平下平均回收率范围在83.3%~101.2%之间,相对标准偏差为4.3%~9.3%。  相似文献   

16.
A rapid and sensitive liquid chromatography tandem mass spectrometry quantitative analysis method was established for the pharmacokinetics and tissue distribution study of physalin B in rat. Physalin B and physalin H (internal standard, IS) were separated on an Agilent Eclips XDB C8 column. MS detection was performed on a triple quadrupole tandem mass spectrometer in the multiple reaction monitoring mode with a positive eletrospray ionization source. The assay was validated in the concentration ranges of 22.6–22600 ng/mL for heart and lung and 4.52–4520 ng/mL for other tissues. The intra‐ and inter‐day precisions (RSD) were ≤9.23 and ≤12.51%, respectively, with accuracy (%) in the range of 88.07–113.2%. A pharmacokinetic study showed that physalin B has a long dwell time with a half‐life of 321.2 ± 29.5 min and clearance of 175.4 ± 25.7 mL/min/kg after intravenous administration. Additionally, physalin B showed a wide tissue distribution with a special higher penetration in lung. The data presented in this study could provide useful information for the further study of physalin B. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

17.
A sensitive and accurate analytical method for the determination of ochratoxin A (OTA) in rice, based on extraction with phosphate-buffered saline/methanol, an immunoaffinity column (IAC) for clean-up, and high performance liquid chromatography with fluorescence detection (HPLC-FD), is described. The limit of quantification of the proposed method was 0.05 g kg–1. Recovery of OTA from rice samples spiked at 0.05 g kg–1 was 92%, with a within-day RSD of 5.4%. The proposed method was applied to 42 rice samples from Portugal and the presence of OTA was found in six samples at concentrations ranging from 0.09 to 3.52 g kg–1. The identification of OTA was confirmed by methyl ester derivatization and then HPLC analysis. The daily intake of OTA by the Portuguese population was also estimated.  相似文献   

18.
鸡肉中11种喹诺酮类药物多残留的高效液相色谱检测   总被引:4,自引:0,他引:4  
林保银 《色谱》2009,27(2):206-210
建立了用荧光检测器同时测定11种喹诺酮类药物(包括诺氟沙星、培氟沙星、环丙沙星、恩诺沙星、氧氟沙星、达氟沙星、洛美沙星、二氟沙星、沙拉沙星、恶喹酸和氟甲喹)在鸡肉中的多残留的高效液相色谱检测方法。鸡肉样品用10%三氯乙酸-乙腈(体积比为7∶3)提取两次并稀释,随后用反相固相萃取柱净化。采用Hypersil BDS-C18色谱柱分离,以乙腈和水为流动相梯度洗脱,荧光检测器用程序编程检测波长检测。11种喹诺酮类药物标准曲线的线性范围为5~1200 μg/L,相关系数大于0.998。在高、中、低三个添加水平下的回收率为56%~119%,批内相对标准偏差为0.4%~16.1%,批间相对标准偏差为1.4%~23.0%。检出限和定量限分别为1~23 μg/kg和4~40 μg/kg。该方法快速、灵敏,达到了兽药残留检测的要求。  相似文献   

19.
高效液相色谱与原子荧光光谱联用分析海产品中的甲基汞   总被引:2,自引:1,他引:2  
建立了高效液相色谱-紫外消解-氢化物发生-原子荧光光谱联用测定海产品中甲基汞的方法, 比较了不同溶剂对海产品中甲基汞提取效率的影响. 实验采用质量分数25% (m/V) KOH甲醇溶液, 室温振荡10 h消解样品, CH2Cl2萃取, 再以0.01 mol/L Na2S2O3水溶液反萃取, 并采用HPLC-UV-HG-AFS测定鱼和扇贝萃取液中的甲基汞的含量. 在优化分离和前处理条件下, 平行进样5次10 ng/mL的汞混合标准溶液, 甲基汞、无机汞和乙基汞的色谱峰面积的相对标准偏差(RSDs)分别为4.4%、 3.9%和4.3%, 甲基汞、无机汞和乙基汞的检出限分别为0.069、 0.15和0.046 ng/mL;鱼和扇贝的甲基汞的加标回收率为96±5%和95±5%.  相似文献   

20.
A high performance liquid chromatographic (HPLC) method for the quantification of 2-hydroxyfluorene (2-OHF) in normal human urine was established using deuterated 2-hydroxyfluorene (2-OHF-d9) as an internal standard with column-switching and fluorescence detection. The 2-OHF-d9 was synthesized by the metabolism of deuterated fluorene with cytochrome P450. The analytes were cleaned up on an ODS pre-column, via column-switching, and separated on an alkylamide-type reversed phase column. The internal standard eluted immediately prior to non-deuterated 2-OHF on the HPLC system and had nearly the same fluorescence characteristics as the non-deuterated 2-OHF. The detection limit was 0.03 nmol l(-1) (S/N = 3) and the calibration range of urine sample was from 0.2 to 50 nmol l(-1). The urine sample treatment involved enzymatic hydrolysis followed by solid phase extraction using a Sep-Pak C18 cartridge. 2-OHF was observed in the form of conjugates such as glucuronide and/or sulfate in human urine, and urinary metabolites were completely hydrolyzed for 2 h with beta-glucuronidase/aryl sulfatase. The proposed method was used to determine urinary 2-OHF in smokers and non-smokers, and showed that the urinary concentrations of 2-OHF in smokers were significantly higher than those in non-smokers (P < 0.01). Thus, the data suggest that urinary 2-OHF might be a sensitive and specific biological marker for the assessment of the exposure to polycyclic aromatic hydrocarbons.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号