首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A water-in-oil type emulsion containing 8-quinolinol has been used for the concentration of traces of heavy metals from seawater prior to their determinations by graphite-furnace atomic absorption spectrometry. The emulsion used was prepared by dissolving 40 mg of 8-quinolinol and 60 mg of sorbitan monooleate (Span-80) in 3.0 ml of toluene and vigorously mixing with 0.70 ml of aqueous hydrochloric acid solution (1.5 mol l−1) by ultrasonic irradiation. The resulting emulsion was gradually injected into 100 ml of sample solution (pH 8.5) and dispersed by stirring as numerous tiny globules. Four heavy metals (Co, Ni, Cu, and Cd) in the sample solution were quantitatively transported through the organic layer into the acidic aqueous droplets encapsulated in the emulsion. After collecting the dispersed emulsion globules, they were demulsified by heating and the heavy metals in the segregated aqueous phase were determined by atomic absorption spectrometry. Owing to the highly efficient concentration (100-fold), these heavy metals at sub-ng ml−1 levels in seawater were determined with satisfactory accuracy and precision, being confirmed with certified reference samples.  相似文献   

2.
Fazakas J  Marinescu DM 《Talanta》1983,30(11):857-860
When the sample is vaporized from the wall of a graphite furnace it is not possible to determine thallium in cadmium and lead by AAS without matrix matching of the standards. In the case of a lead matrix and vaporization from the wall, the thallium signal is barely distinguishable from the base-line. When the sample is vaporized from a platform, and the peak area is used for measurement, pure aqueous standards may be used for instrument calibration. The peak heights and areas of the thallium signals are considerably enhanced by vaporization from a platform (peak height 1.7-fold and peak area 2.6-fold in pure aqueous solutions as compared to vaporization from the wall). The enhancement factors are larger in presence of the cadmium or lead matrix since here the reduced interference also makes a contribution.  相似文献   

3.
Three major types of pre-concentration methods were evaluated and optimised for the extraction and determination of Cd, Cu, Ni, Pb and Zn from seawater samples. The traditional APDC/DDDC-Freon liquid-liquid extraction method showed excellent results for a multi-elemental analysis. However, the technique is labour consuming, very sensitive to operational conditions, employs environmentally unsafe and expensive solvents and requires large sample volumes. In the solid phase extraction method, the performances of a traditional Amberlite XAD-4 and a novel Dowex Optipore V-493 were evaluated. Application of Dowex Optipore V-493 resin provided better results at low concentrations than the generally used Amberlite XAD-4 resin using low sample volumes. However, the presence of natural organic compounds may decrease extraction efficiency of both resins for Cu. Thus, a pre-treatment with UV irradiation is advantageous for samples with high organic content. Cobalt co-precipitation methods showed good Cu and Ni recoveries, but gave poor results for Cd at low concentrations. In addition, high sample volumes are required. Both solid phase and co-precipitation methods showed unsatisfactory results in determination of Pb. Finally, a summary of methods advantages are given for choosing the most suitable method.  相似文献   

4.
van Beek H  Greefkes HC  Baars AJ 《Talanta》1987,34(6):580-582
An efficient wet digestion method is described which allows the determination of various elements in animal tissues. Copper, iron, manganese, lead and cadmium in one dilution of the digested sample can be determined by means of graphite-furnace atomic-absorption spectrometry, with Zeeman background correction. Tests with the National Bureau of Standards Bovine Liver SRM as reference gave analytical results, obtained with calibration graphs as well as by the standard-addition method, which agreed well with the certified values.  相似文献   

5.
A bidentate chelating agent has been proposed to preconcentrate seven metal ions dissolved in an aqueous sample for their simultaneous determination using energy-dispersive x-ray fluorescence spectrometry. The metal ions are precipitated as their polymeric piperazino-1,4-bis(dithiocarbamate) chelates, which are then collected by vacuum filtration on a Millipore membrane filter for direct examination by x-ray fluorescence analysis. Iron, cobalt, nickel, copper and zinc are determined by means of their K x-rays and mercury and lead by means of their L x-rays. A detection limit in the μg1−1 range can be achieved for all metals tested in 250-ml water samples with a counting time of 600 s. Effective precipitation of all metals occurs at pH 6–7. The recoveries of eight analyses of the metals in a multielement standard using the proposed method ranged from 97 to 105% and the precision ranged from 2.3 to 3.1%. High concentrations of calcium and magnesium do not interfere with the method. The method is simple, sensitive and accurate, and has been used for the simultaneous determination of the seven metals under study in environmental samples and synthetic mixtures.  相似文献   

6.
A preconcentration method of lead in waters by adsorption on a tantalum wire was developed for electrothermal atomization atomic absorption spectrometry with a tungsten tube atomizer. After the preconcentration, the tantalum wire was directly inserted into the tungsten tube atomizer. In the preconcentration (adsorption) process for lead, the optimal immersing time was 90 s and the best pH was 4. Under the optimal conditions, the detection limit for lead by the tantalum wire preconcentration method was 6.0 pg mL− 1 (3S/N) and the relative standard deviation was 6.1%. The influences of large amounts of concomitants on the preconcentration of lead were evaluated. Even though 103 to 104-fold excess of matrix elements existed in aqueous solution, the lead absorption signal was not significantly affected by the matrix elements. The method with preconcentration on a tantalum wire was applied to the determination of lead in river waters and proved to be sensitive, simple, and convenient. Because this preconcentration method can be utilized in the in-situ treatment of trace lead in environmental water samples, it was unnecessary to carry the water samples to the analytical work place. The present technique was shown to be useful for the determination of lead in environmental water samples at 0.1−1 μg L− 1.  相似文献   

7.
Matoso E  Kubota LT  Cadore S 《Talanta》2003,60(6):1105-1111
An analytical method using silica gel chemically modified with zirconium (IV) phosphate for preconcentration of lead and copper, in a column system, and their sequential determination by flame atomic absorption spectrometry (FAAS), was developed. Sample solutions are passed through a glass column packed with 100 mg of the sorbent material, at pH 4.5, and lead and copper are eluted with 1.0 mol l−1 HNO3 at a flow rate of 2.0 ml min−1. The extraction of copper is affected by Fe(II), Mn(II), Zn(II), Ni(II) and Co(II) while only Fe(II) interferes in the lead determination. These interferences may be overcome with an appropriate addition of a KI or NaF solution. An enrichment factor of 30 was obtained for both metals. While the limits of detection (3σ) were 6.1 and 1.1 μg l−1, for Pb and Cu, respectively, the limits of determination were 16.7 and 3.3 μg l−1. The precision expressed as relative standard deviation (R.S.D.) obtained for 3.3 μg l−1 of Cu and 16.7 μg l−1 of Pb were 4.3 and 4.7%, respectively, calculated from ten measurements. The proposed method was evaluated with reference material and was applied for the determination of lead and copper in industrial and river waters.  相似文献   

8.
As bifunctional reagents, bis(tosyloxyethoxy)benzenes can react with p-tert-butylcalix[4]arene or p-tert-butylthiacalix[4]arene to afford intramolecularly bridged (1+1) or intermolecularly bridged (2+2) products. It was found that the bridging pattern strongly depended on the structure of bis(tosyloxyethoxy)benzene and the kind of calixarene. For the ortho-isomer of bis(tosyloxyethoxy)benzene, intramolecularly bridged calix[4]arene and thiacalix[4]arene were the main products. For the para-isomer, the bridging reaction was in a (2+2) fashion. As for the meta-isomer, double thiacalix[4]arene and intramolecularly bridged calix[4]crown were synthesized.  相似文献   

9.
A novel automated off-line preconcentration system for trace metals (Al, Mn, Fe, Co, Ni, Cu, Zn, Cd, and Pb) in seawater was developed by improving a commercially available solid-phase extraction system SPE-100 (Hiranuma Sangyo). The utilized chelating resin was NOBIAS Chelate-PA1 (Hitachi High-Technologies) with ethylenediaminetriacetic acid and iminodiacetic acid functional groups. Parts of the 8-way valve made of alumina and zirconia in the original SPE-100 system were replaced with parts made of polychlorotrifluoroethylene in order to reduce contamination of trace metals. The eluent pass was altered for the back flush elution of trace metals. We optimized the cleaning procedures for the chelating resin column and flow lines of the preconcentration system, and developed a preconcentration procedure, which required less labor and led to a superior performance compared to manual preconcentration (Sohrin et al. [5]). The nine trace metals were simultaneously and quantitatively preconcentrated from ∼120 g of seawater, eluted with ∼15 g of 1 M HNO3, and determined by HR-ICP-MS using the calibration curve method. The single-step preconcentration removed more than 99.998% of Na, K, Mg, Ca, and Sr from seawater. The procedural blanks and detection limits were lower than the lowest concentrations in seawater for Mn, Ni, Cu, and Pb, while they were as low as the lowest concentrations in seawater for Al, Fe, Co, Zn, and Cd. The accuracy and precision of this method were confirmed by the analysis of reference seawater samples (CASS-5, NASS-5, GEOTRACES GS, and GD) and seawater samples for vertical distribution in the western North Pacific Ocean.  相似文献   

10.
Selective extraction techniques followed by adsorption experiment and statistical analysis were employed to estimate and compare the relative roles of metal oxides and organic substance in adsorption of Pb, Cd, Cu and Co onto surface coatings. Results indicated that metal oxides were very important sorbents for all of metal ions involved in this study, especially for Pb and Co. Furthermore, manganese oxides contributed to the absolute majority of Co adsorption regardless of concentration. But for Cu and Cd, organic materials are also very important sorbent phases, particularly for Cu, organic materials contributed to most of the Cu adsorption regardless of concentration. In addition, the analysis suggested the extraordinary predominance of Mn oxides for metal adsorption at the low concentrations. Considering the low concentration in natural water environments, Mn oxides might exert the greatest influence on the behavior of heavy metals.  相似文献   

11.
An evaluation of the non-boiling evaporation technique for the preconcentration of Pb, Cd, Cu, Zn at the pg g?1 level in water samples is presented. Various improvements were made to allow efficient control of contamination problems at these extremely low concentrations. They include the choice of FEP Teflon for the evaporation containers and the use of sophisticated cleaning, ageing and pre-conditionning procedures. Detailed calibration graphs were obtained down to the sub-pg g?1 level by processing ultra-low concentration standards. This technique was then applied to the determination of these four metals in snow samples collected in Greenland and Antarctica.  相似文献   

12.
Tokman N  Akman S  Ozeroglu C 《Talanta》2004,63(3):699-703
In this study, a water-soluble polymer, polyvinylpyrrolidinone (PVP) having chelating functionalities was used for the preconcentration and separation of traces of Pb, Cu, Ve and Mn prior to their determination by graphite furnace atomic absorption spectrometry. For this purpose, the sample and the PVP solutions were mixed and the metal bound polymer was precipitated by adding the mixture onto acetone. The precipitate was separated by decantation and dissolved with water. By increasing the ratio of the volumes of sample to water used in dissolving the precipitate, the analyte elements were concentrated as needed. The concentration of trace elements was determined using graphite furnace atomic absorption spectrometry. The analyte elements in matrix free aqueous solutions were quantitatively recovered. The validity of the proposed method was checked with a standard reference material (NIST SRM 1577b bovine liver) and spiked fruit juice, sea water and mineral water samples. The analytical results were found to be in good agreement with certified and added values. Detection limits (3δ) were 1.7, 3.6 and 4.1 μg l−1 for Pb, Cu and Mn, respectively, using 10 μl of sample volume. The method is novel and can be characterized by rapidity, simplicity, quantitative recovery and high reproducibility.  相似文献   

13.
Fang Z  Guo T  Welz B 《Talanta》1991,38(6):613-619
Cadmium, lead and copper were determined in synthetic sea-water, drinking water and the NBS 1643b Trace Elements in Water standard reference material at mug/l. levels by flame atomic-absorption spectrometry after on-line preconcentration by sorbent extraction with a flow-injection system. Bonded silica with octadecyl functional groups packed in a micro column of 100 mul capacity was used to collect diethylammonium diethyldithiocarbamate complexes of the heavy metals in the aqueous samples. The sample loading time was 20 sec at a flow-rate of 3.3 ml/min. Ethanol or methanol was used to elute the adsorbed analytes into the spectrometer. The sample loading rate, elution rate and pH were optimized. Enrichment factors of 19-25 for Cd, Pb and Cu were achieved at sampling frequencies of 120/hr with precisions of 1.4, 1.0 and 1.3% rsd (n = 11), respectively. The detection limits (3sigma) for Cd, Pb and Cu were 0.3, 3 and 0.2 mug/l., respectively. Determination of Cd, Pb and Cu in NBS SRM 1643b showed good agreement with the certified values. Recoveries of Cd and Pb added to sea-water were 95 and 102%, respectively.  相似文献   

14.
An aluminum hydroxide coprecipitation method for the determination of cadmium, copper and lead by flame atomic absorption spectrometry in aqueous solutions, seawater and mineral water samples has been investigated. The coprecipitation conditions, such as the effect of the pH, the amount of carrier element, the effect of possible matrix ions and the time were examined in detail for the studied elements. It was found that cadmium, copper and lead are co-precipitated quantitatively (≥95%) with aluminum hydroxide at pH 7 with low R.S.D. values of around 2 to 3%. Detection limits (38) were 6 ng ml−1 for Cd, 3 ng ml−1 for Cu and 16 ng ml−1 for Pb. The method proposed was validated by the analysis of HPS 312205 seawater standard reference material and spiked mineral water samples.  相似文献   

15.
A new calix[4]dicyano-diimidazole ligand was prepared in two steps from a de-tert-butylated calix[4]arene. The corresponding Cu (I) complex was found to be remarkably stable. The X-ray structure of the latter revealed a mixture of both monomeric-mononuclear and dimeric-dinuclear complexes. Detailed investigations on this copper complex, involving NMR (VT and DOSY), Infra-red, and MS analyses, demonstrated that the dimeric-dinuclear complexe does not exist in solution. Despite the presence of two cyano binding groups on the calixarene platform, every attempts to isolate a stable Cu(II) complex failed.  相似文献   

16.
石墨炉原子吸收法测定土壤中铅、镉、钴、锑、铍   总被引:2,自引:0,他引:2  
建立石墨炉原子吸收法测定土壤中铅、镉、钴、锑、铍含量的方法。优化了石墨炉原子吸收光谱法测定条件,在最佳实验条件下,采用硝酸-盐酸-氢氟酸-双氧水混合酸体系微波消解土壤样品,选用抗坏血酸-硝酸镁混合溶液为基体改进剂。铅、镉、钴、锑、铍的质量浓度在各自的范围内与吸光度成良好的线性关系,相关系数均大于0.999,各元素的检出限为0.008~0.06 μg/g。样品加标回收率为90.5%~104.0%,测定结果的相对标准偏差均小于2.5%(n=6)。该方法样品前处理简便,灵敏度高,检出限低,测定结果准确、可靠,可用于土壤中铅、镉、钴、锑、铍的测定。  相似文献   

17.
Treatment of readily available O,O′-1,1,3,3-tetraisopropyldisiloxane-1,3-diyl-bridged p-tert-butylthiacalix[4]arene (1) with tri(ethylene glycol) di-p-tosylate and subsequent desilylation gave O,O′-bridged thiacalix[4]crown 3 in an excellent yield. Mono-O-alkylation of 3 with ethyl bromoacetate, followed by optical resolution by chiral HPLC, and subsequent hydrolysis of the ester moiety gave inherently chiral O,O′-bridged thiacalix[4]crowncarboxylic acid (+)-6, which clearly discriminated enantiomeric primary amines, as well as amino esters, by 1H NMR spectroscopy.  相似文献   

18.
为寻求一种能够直接对中草药中重金属进行快速检测的方法,采用压片法对样品进行前处理,建立了能量色散-X射线荧光光谱法快速检测中草药中痕量重金属镉、铅、铜元素的方法。在20 min即可完成检测,镉、铅、铜检出限分别为0.072、0.207、0.340 mg/kg,测试结果表明与原子吸收和ICP-MS相比,本方法数据稳定性和准确度良好,具有快速、准确、简单的优点,能够满足药典中对重金属元素的限量要求,适用于现场快速检测与质量控制检测。  相似文献   

19.
Nikolova B  Jordanov N 《Talanta》1982,29(10):861-866
The possibility of applying diethylammonium diethyldithiocarbamate and butyl acetate for the extraction of copper, cadmium, lead and bismuth from molar solutions of orthophosphoric acid, and from solutions containing up to 55% pyrophosphoric acid and 20% tripolyphosphoric acid has been investigated. Some characteristics of the various diethylammonium diethyldithiocarbamate-butyl acetate-phosphoric acid systems are described. Suitable conditions have been found for flame atomic-absorption spectrometric determination of the ions extracted. This extraction/AAS approach has been used to determine copper, cadmium, lead and bismuth in some iron-, aluminium- and tin-containing samples dissolved in concentrated orthophosphoric acid. The same approach is used for determining 10(-5)-10(-6)% copper, cadmium and lead in orthophosphoric acid and in alkali-metal mono and dihydrogen phosphates.  相似文献   

20.
The electrodepositons of Te, Bi, Ni, Sb and Au from aqueous solution of pH = 1 on the cathode surface have been studied for X-ray fluorescence analysis (XRF). A special holder for a copper electrode has been constructed to perform the electrodeposition process on only one side of the electrode. After electrolysis, the copper electrode can be easily removed from the holder; after rinsing it with water and drying it can be analyzed by XRF. The proposed method of sample preparation and preconcentration of Te, Bi, Ni, Sb, Au provides suitable samples which are devoid of the negative and undesirable effects of XRF analysis, such as particle size and matrix effects. The influence of time on the deposition yield has been examined. The method of preconcentration is efficient. The inhomogeneity of the prepared specimens has been studied using internal standard method. The calibration is based on using synthetic standards, certified reference materials and standard addition method. The best results are achieved by the standard addition method. The agreement between results obtained with XRF analysis and certified values is satisfactory and indicates the usefulness of the proposed method for determination of Te, Bi, Ni, Sb and Au in anode slime.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号