首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A strategy is presented for doping graphene into layered double hydroxide films (LDHs) as a means of improving charge transport of the LDH film in a modified glassy carbon electrode. This result in an enhanced electrocatalytic current for dopamine (DA) and a good separation of the potentials of DA, uric acid and ascorbic acid. Under selected conditions, the square wave voltammetric response of the electrode to DA is linear in the concentration range from 1.0 to 199???M even in the presence of 0.1?mM ascorbic acid, and the detection limit is 0.3???M at a signal-to-noise ratio of 3. The method was applied to the determination of DA in pharmaceutical injections with satisfactory results.
Figure
A strategy is presented for doping graphene into layered double hydroxide films (LDHs) as a means of improving charge transport of the LDH film in a modified glassy carbon electrode. This result in an enhanced electrocatalytic current for dopamine (DA) and the square wave voltammetric response of the electrode to DA is linear in the concentration range from 1.0 to 199???M with the detection limit of 0.3???M. The method was applied to the determination of DA in pharmaceutical injections with satisfactory results.  相似文献   

2.
We describe an efficient and easily fabricated electrochemiluminescence detection system for microchip capillary electrophoresis. A 300-μm-diameter platinum disc working electrode was embedded in a titanium tube which provides an adequate holding for working electrode and acts as counter electrode. We also have designed a simplified detection cell with a guide channel for the electrode. The integrated working-counter electrode can be easily aligned to the outlet of the separation channel through the guide channel. The functionality of the system was demonstrated by separation and detection of proline and tripropylamine. The response to proline is linear in the range from 5 μM to 5,000 μM, and the detection limit is 1.0 μM (S/N?=?3). The system was further applied to the determination of chlorpromazine hydrochloride in pharmaceutical formulations. The system is believed to have potential applications in pharmaceutical analysis.
Figure
We described an efficient and easily fabricated electrochemiluminescence detection system for microchip capillary electrophoresis. The functionality of the system was demonstrated by separation and detection of proline and tripropylamine. The response to proline is linear in the range from 5 μM to 5,000 μM, and the detection limit is 1.0 μM (S/N?=?3).  相似文献   

3.
A highly sensitive electrochemical sensor for the simultaneous determination of catechol (CC) and hydroquinone (HQ) was fabricated by electrodeposition of gold nanoparticles onto carbon nanofiber film pre-cast on an Au electrode. Both CC and HQ cause a pair of quasi-reversible and well-defined redox peaks at the modified electrode in pH?7.0 solution. Simultaneously, the oxidation peak potentials of CC and HQ become separated by 112?mV. When simultaneously changing the concentrations of both CC and HQ, the response is linear between 9.0???M and 1.50?mM. In the presence of 0.15?mM of the respective isomer, the electrode gives a linear response in the range from 5.0 to 350???M, and from 9.0 to 500???M for CC and HQ, respectively, and detection limits are 0.36 and 0.86???M. The method was successfully examined for real sample analysis with high selectivity and sensitivity.
Figure
Highly sensitive and simultaneous determination of catechol and hydroquinone was realized at the GNPs/CNF/Au electrode (d), and its peak currents had nearly two times higher than that of the CNF/Au electrode(c), while only one oxidation peak was observed for both analytes at the bare Au electrode (a) and GNPs/Au electrode (b)  相似文献   

4.
We describe a glassy carbon electrode modified with nano-gold and a film of poly(sulfosalicylic acid) that was obtained by electropolymerization of sulfosalicylic acid. The electrochemical characteristics of the electrode were investigated by using (a) the anionic hexacyanoferrate, and (b) the cationic ruthenium-trisbipyridyl systems as redox probes. The electrode displayed selective and enhanced electroanalytical response towards dopamine (DA), obviously because DA (which is cationic) is accumulated at the electrode, while anions such as ascorbic acid (AA) do not and in fact are being repelled. A 2000-fold molar excess of AA is tolerated after a 120-s accumulation time followed by stripping detection at pH?6.5. Response is linear with the concentration of DA in the range from 0.05 to 5???M, and the detection limit is 7 nM (at an S/N of 3) even in the presence of 100 ??M concentrations of AA.
Figure
The poly (sulfosalicylic acid) film incorporated nano-gold modified electrode was fabricated and used for the selective detection of dopamine. A 2000-fold molar excess of ascorbic acid is tolerated by exploiting an accumulation effect. This work shows high specificity, sensitivity and wide linear range.  相似文献   

5.
We report on the voltammetric determination of the flavonoid Baicalein by using a carbon paste electrode that was doped with multi-walled carbon nanotubes. The resulting sensor exhibits excellent redox activity towards Baicalein due to the large surface area and good conductivity of the electrode. Cyclic voltammetry at various scan rates was used to investigate the redox properties of Baicalein. At the optimum conditions, the sensor displays a linear current response to Baicalein in the 0.02–10 μM concentration range, with a limit of detection of 4.2 n M. The method was successfully applied to the determination of Baicalein in spiked human blood serum samples and in a Chinese oral liquid.
Figure
We construct a new voltammetric sensor, based on multi-walled carbon nanotubes (MWCNT) doped Carbon paste electrode(CPE), The proposed electrode can improve the oxidation of Baicalein intensively, which can applied to the quantitative determination of Baicalein with wide linear response and low detection limit.  相似文献   

6.
A carbon paste electrode (CPE) was modified with multi-wall carbon nanotubes and successfully applied to the determination of silver ion by differential pulse anodic stripping voltammetry. Compared to a conventional CPE, a remarkably improved peak current response and sensitivity is observed. The analytical procedure consisted of an open circuit accumulation step for 2?min in ?0.4?V, this followed by an anodic potential scan between +0.2 and?+?0.6?V to obtain the voltammetric peak. The oxidation peak current is proportional to the concentration of silver ion in the range from 1.0?×?10?8 to 1.0?×?10?5?mol?L?1, with a detection limit of 1.8?×?10?9?mol?L?1 after an accumulation time of 120?s. The relative standard deviation for 7 successive determinations of Ag(I) at 0.1???M concentration is 1.99%. The procedure was validated by determining Ag(I) in natural waters.
Figure
Differential pulse voltammogram (DPV) of Ag+ solution at MCPE  相似文献   

7.
A sensitive and selective electrochemical sensor for the determination of nitrobenzene (NB) was developed based on a carbon paste electrode (CPE) modified with a nanocomposite prepared from the conducting polymer poly(3,4-ethylenedioxythiophene) and carbon nanotubes. The modified CPE exhibits good conductivity, a large surface area, and excellent catalytic activity towards the electrochemical reduction of NB. Under optimal conditions, the modified CPE is capable of detecting NB in the 0.25 to 43 μM concentration range and with a detection limit at 83 nM. Moreover, the sensor is highly stable and reusable, and free of interferences by other commonly present nitro compounds. It was used to determine NB in wastewater samples.
Figure
A sensitive nitrobenzene sensor was developed based on the chemically synthesized nanocomposite composed of conducting polymer poly(3,4-ethylenedioxythiophene) and carbon nanotubes, which showed excellent catalytic activity towards the electrochemical reduction of nitrobenzene.  相似文献   

8.
Arrays made from quasi-aligned nanofibers consisting of a TiC/C composite were produced directly on a titanium alloy substrate by a thermochemical process. Their morphology, structure and composition were characterized by electron microscopy, X-ray diffraction and X-ray photoelectron spectroscopy. The arrays were directly utilized as an electrode without further treatment and display high catalytic activity in terms of hydrazine oxidation. The low overpotential decreases gradually when increasing pH values from 5 to 10. The detection range is linear from 0.1 to 1,635???M concentrations, and the detection limit is as low as 0.026???M (S/N?=?3). The selectivity of the electrode and its general performance and stability are very good. The improved electrochemical properties of the new electrode are attributed to the synergic effect of the highly conducting TiC nanowire core and an abundant amount of edge-plane-like defects on the carbon shells.
Figure
Quasi-alinged core-shell TiC/C nanofiber arrays were produced by a simple thermochemical method. The nanofiber arrays display electrocatalytic activity towards oxidation of hydrazine with a wide linear range and a very low detection limit of 0.026???M (S/N?=?3).  相似文献   

9.
A sensitive amperometric sensor for hydrogen peroxide (HP) was constructed that is based on a glassy carbon electrode (GCE) modified with silver nanoparticles on poly(alizarin yellow R). The polymer was electropolymerized onto the surface of the GCE by cyclic voltammetry (CV), and the AgNPs were then electrodeposited onto its surface. The electrode was characterized by scanning electron microscopy and CV, and used for amperometric determination of HP. The electrode exhibits a favorable catalytic activity towards the reduction of HP, with a linear response range from 1.0???M to 450???M and a detection limit of 0.32???M. The sensor also displays high selectivity, excellent reproducibility, and good long-term stability.
Figure
Schematic representation of the preparation process of the HP sensor and catalytic activity towards HP  相似文献   

10.
We report on a new electrode for the determination of adenosine-5??-triphosphate (ATP). It is based on modified carbon paste electrode that contains an ionic liquid (IL) as the binder. The electrode shows strong electrocatalytic oxidative activity towards ATP at pH 4.5 in giving a well-defined single oxidation peak. The oxidation reaction is adsorption-controlled and due to the presence of the highly conductive IL. The electron transfer rate constant was calculated to be 2.04×10?C3 s?C1, and the surface coverage is 1.11×10?C10 mol cm?C2. Under the selected conditions, the oxidation peak current changes linearly with the concentration of ATP in the range from 5.0 to 1000???mol L?1 and a detection limit of 1.67???mol L?1 (3???) as determined by differential pulse voltammetry. The method displays good selectivity and was applied to the determination of ATP injection samples with satisfactory results.
Figa
An ionic liquid 1-carboxyl-methyl-3-methylimidazolium hexafluorophosphate modified carbon paste electrode was fabricated and used for the sensitive detection adenosine-5??-triphosphate (ATP). The electrochemical oxidation of ATP was greatly enhanced due to the presence of IL in the carbon paste and the electrochemical parameter was calculated.  相似文献   

11.
Ferrocene (Fc) was encapsulated in the cavities of a NaY zeolite by vapor diffusion via sublimation at below 100?°C. The resulting Fc@NaY zeolite composite was investigated by power X-ray diffraction, diffuse reflectance UV?Cvis and FT-IR spectroscopy, and by cyclic voltammetry. The results indicated that Fc was encapsulated into the zeolite whose microporous structure had remained intact. The Fc in the silica matrix had retained its electroactivity and did not leach out. A glucose biosensor was obtained by immobilization of the modified zeolite and glucose oxidase on a carbon paste electrode. It displays a linear response to glucose (from 0.8???M to 4.0?mM), a detection limit of 0.2???M, and a response time of 4?s. The good performance of the biosensor is ascribed to the biocompatibility of the zeolite and presence of Fc which facilitates the electron transfer from the enzyme to the surface of the electrode.
Figure
Reagentless glucose biosensor is constructed by immobilization of glucose oxidase on a ferrocene@NaY zeolite composite. The biosensor displays very good responses to the different concentrations of glucose.  相似文献   

12.
Nanocomposites composed of cuprous oxide (Cu2O) and graphene were synthesized via reduction of copper(II) in ethylene glycol. This material possesses the specific features of both Cu2O and graphene. Its morphology was characterized by X-ray diffraction, transmission electron microscopy, scanning electron microscopy, and X-ray photoelectron spectroscopy. Cyclic voltammetry was used to evaluate the electrochemical response of a glass carbon electrode (GCE) modified with the nanocomposite towards dopamine (DA). Compared to the bare GCE, the Cu2O nanoparticles modified electrode and the graphene modified electrode, the nanocomposites modified electrode displays high electrocatalytic activity in giving an oxidation peak current that is proportional to the concentration of DA in the range from 0.1 to 10???M,with a detection limit of 10?nM (S/N?=?3). The modified electrode shows excellent selectivity and sensitivity even in the presence of high concentration of uric acid and can be applied to determine DA in real samples with satisfactory results.
Figure
Cu2O/Graphene nanocomposites were successfully prepared, Cu2O particles were uniformly distributed on transparent graphene and no particles scattered out of the supports. Electrochemical experiment results indicate that the nanocomposites modified electrode displays a wide linear region, excellent selectivity and sensitivity to DA.  相似文献   

13.
We describe a biosensor for phenolic compounds that is based on a glassy carbon electrode modified with tyrosinase immobilized on multiwalled carbon nanotubes (MWNTs). The MWNTs possess excellent inherent electrical conductivity which enhances the electron transfer rate and results in good electrochemical catalytic activity towards the reduction of benzoquinone produced by enzymatic reaction. The biosensor was characterized by cyclic voltammetry, and the experimental conditions were optimized. The cathodíc current is linearly related to the concentration of the phenols between 0.4???M and 10???M, and the detection limit is 0.2???M. The method was applied to the determination of phenol in water samples.
Figure
A tyrosinase and carbon nanotubes (MWNTs) modified glassy carbon electrode was fabricated and used for the sensitive detection of phenol. The reduction peak of benzoquinone produced by enzymatic reaction of phenol was greatly enhanced due to the presence of MWNTs(c)  相似文献   

14.
We report on a carbon paste electrode that was modified with a binuclear manganese(II) complex by the drop-coating method. A study on the mechanism of the electro-oxidation of tryptophan (Trp) at this electrode indicated that it enables Trp to be determined with good sensitivity and selectivity. Second-order derivative linear sweep voltammetry at pH 4.1 revealed that a sensitive anodic peak appears at 812?mV (vs. SCE) whose current is proportional to the concentration of Trp in the concentration range from 0.1 to 1.0???mol?L?1 and 1.0 to 80???mol?L?1, with a detection limit (S/N?=?3) of 0.08???mol?L?1 (60?s of accumulation). The method was applied to the determination of Trp in amino acid injection solutions with satisfactory results.
Figure
The electrochemical behavior of tryptophan at a carbon paste electrode modified with a binuclear manganese(II) complex Mn2(phen)2(p-MBA)4(H2O) was investigated. The modified electrode showed high electrocatalytic activity toward the oxidation of tryptophan and the peak current increases linearly with tryptophan concentration in the range of 0.1 to 80???mol L?1.  相似文献   

15.
Glassy carbon electrodes (GCE) and carbon paste electrodes (CPE) were modified with imidazole functionalized polyaniline with the aim to develop a sensor for lead (II) in both acidic and basic aqueous solution. The electrodes were characterized by cyclic voltammetry and differential pulse adsorptive stripping voltammetry. The limit of detections obtained with glassy carbon electrode and carbon paste electrode are 20?ng?mL-1 and 2?ng?mL-1 of lead ion, respectively. An interference study was carried out with Cd(II), As(III), Hg(II) and Co(II) ions. Cd(II) ions interfere significantly (peak overlap) and As(III) has a depressing effect on the lead signal. The influence of pH was investigated indicating that bare and modified GCE and CPE show optimum response at pH?4.0 ± 0.05.
Figure
Imidazole functionalized polyaniline modified glassy carbon and carbon paste electrodes were used for lead ion detection by using CV and DPASV techniques. The lower detection limit observed with GCE and CPE are 20?ng mL-1 and 2?ng mL-1.  相似文献   

16.
We report on a sensitive electrochemical sensor for dopamine (DA) based on a glassy carbon electrode that was modified with a nanocomposite containing electrochemically reduced graphene oxide (RGO) and palladium nanoparticles (Pd-NPs). The composite was characterized by scanning electron microscopy, energy dispersive spectroscopy, and electrochemical impendence spectroscopy. The electrode can oxidize DA at lower potential (234 mV vs Ag/AgCl) than electrodes modified with RGO or Pd-NPs only. The response of the sensor to DA is linear in the 1–150 μM concentration range, and the detection limit is 0.233 μM. The sensor was applied to the determination of DA in commercial DA injection solutions.
Figure
Schematic representation showing the oxidation of DA at RGO-Pd-NPs composite electrode.  相似文献   

17.
An electrode sensitive to uric acid was prepared by electrodeposition of nickel(II) hexacyanoferrate(III) on the surface of a glassy carbon electrode modified with multi-walled carbon nanotubes. The morphology of the material was characterized by scanning electron microscopy and Fourier transform infrared spectrometry. The modified electrode were characterized via cyclic voltammetry and amperometry (i - t). It exhibited efficient electron transfer ability and a strong and fast (< 3?s) response towards uric acid which is linear in the range from 0.1???M to 18???M, with a lower detection limit of 50 nM (at an S/N ratio of 3). In addition, the electrode exhibited good reproducibility and long-term stability.
Figure
A fast and sensitive uric acid electrochemical sensor has been fabricated by electrodepositing nickel hexacyanoferrate nanoparticles onto multi-walled carbon nanotubes/glassy carbon electrode. The sensor had excellent stability, rapid response, ease of construction and utilization for uric acid determination  相似文献   

18.
The electrochemical oxidation of guanosine-5??-monophosphate (GMP) was studied with a glassy carbon electrode modified with a composite made from graphene and multi-walled carbon nanotubes. GMP undergoes an irreversible oxidation process at an oxidation peak potential of 987?mV in phosphate buffer solution. Compared to other electrodes, the oxidation peak current of GMP with this electrode was significantly increased, and the corresponding oxidation peak potential negatively shifted, thereby indicating that the modified material exhibited electrochemical catalytic activity towards GMP. Chronocoulometry demonstrates that the material also effectively increases the surface area of the electrode and increases the amount of GMP adsorbed. Under the optimum conditions, the oxidation current is proportional to the GMP concentration in the range from 0.1 to 59.7???M with a correlation coefficient of 0.9991. The detection limit is 0.025???M (at S/N?=?3).
Figure
We have developed an electrochemical method for sensitive determination of guanosine-5??-monophosphate (1) based on graphene and multi-walled carbon nanotubes modified glassy carbon electrode by amperometry.  相似文献   

19.
A biosensor for hydrogen peroxide (HP) was developed by immobilizing hemoglobin on a glassy carbon electrode modified with activated carbon nanoparticles/Nafion. The characteristics of the sensor were studied by UV?Cvis spectroscopy and electrochemical methods. The immobilized Hb retained its native secondary structure, undergoes direct electron transfer (with a heterogeneous rate constant of 3.37?±?0.5?s?1), and displays excellent bioelectrocatalytic activity to the reduction of HP. Under the optimal conditions, its amperometric response varies linearly with the concentration of HP in the range from 0.9???M to 17???M. The detection limit is 0.4???M (at S/N?=?3). Due to the commercial availability and low cost of activated carbon nanoparticles, it can be considered as a useful supporting material for construction of other third-generation biosensors.
Figure
A biosensor for hydrogen peroxide (HP) was developed by immobilizing hemoglobin on a glassy carbon electrode modified with activated carbon nanoparticles/Nafion. It can be considered as a useful supporting material for construction of other third-generation biosensors.  相似文献   

20.
A differential pulse voltammetric method was developed for the simultaneous determination of paracetamol, 4-aminophenol and dopamine at pH 7.0 using a glassy carbon electrode (GCE) coated with gold nanoparticles (AuNPs) and a layered double hydroxide sodium modified with dodecyl sulfate (SDS-LDH). The modified electrode displays excellent redox activity towards paracetamol, and the redox current is increased (and the corresponding over-potential decreased) compared to those of the bare GCE, the AuNPs-modified GCE, and the SDS-LDH-modified GCE. The modified electrode enables the determination of paracetamol in the concentration range from 0.5 to 400???M, with a detection limit of 0.13???M (at an S/N of 3). The sensor was successfully applied to the stimultaneous determination of paracetamol and dopamine, and of paracetamol and 4-aminophenol, respectively, in pharmaceutical tablets and in spiked human serum samples.
Figure
1. Gold nanoparticles and organophillic layered double hydroxide modified glassy carbon electrode was fabricated. 2. The modified electrode displayed excellent redox activity towards paracetamol. 3. This electrode was successfully applied to the simultaneous determination of paracetamol and dopamine, and of paracetamol and 4-aminophenol, respectively  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号