共查询到20条相似文献,搜索用时 15 毫秒
1.
Dai Hongxiu Wang Nan Wang Donglei Zhang Xiaomei Ma Houyi Lin Meng 《Mikrochimica acta》2016,183(11):3053-3059
Microchimica Acta - The article describes an electrochemical sensor for the detection of uric acid (UA) by using a glassy carbon electrode (GCE) modified with a composite consisting of... 相似文献
2.
3.
We report on a sensitive electrochemical sensor for dopamine (DA) based on a glassy carbon electrode that was modified with a nanocomposite containing electrochemically reduced graphene oxide (RGO) and palladium nanoparticles (Pd-NPs). The composite was characterized by scanning electron microscopy, energy dispersive spectroscopy, and electrochemical impendence spectroscopy. The electrode can oxidize DA at lower potential (234 mV vs Ag/AgCl) than electrodes modified with RGO or Pd-NPs only. The response of the sensor to DA is linear in the 1–150 μM concentration range, and the detection limit is 0.233 μM. The sensor was applied to the determination of DA in commercial DA injection solutions. Figure
Schematic representation showing the oxidation of DA at RGO-Pd-NPs composite electrode. 相似文献
4.
通过在玻碳电极表面电化学还原氧化石墨烯的方法制备了石墨烯修饰电极,研究了美洛昔康在该修饰电极上的电化学行为。优化了包括支持电解质及pH、修饰剂用量、富集电位及时间等测定条件,据此建立了一种直接测定美洛昔康的电化学分析方法。在0.1 mol/L Britton-Robinson缓冲液(pH 3.0)中,氧化峰电流与美洛昔康浓度在1.0×10-6~8.0×10-5mol/L范围内呈现良好的线性关系,检出限为3.0×10-7mol/L(S/N=3)。方法可用于片剂和尿样中美洛昔康的测定。 相似文献
5.
Junhua Li Daizhi Kuang Yonglan Feng Fuxing Zhang Zhifeng Xu Mengqin Liu Deping Wang 《Mikrochimica acta》2013,180(1-2):49-58
We report on a glassy carbon electrode that was modified with a composite made from graphene oxide (GO) and multiwalled carbon nanotubes (MWCNT) that enables highly sensitive determination of L-tyrosine. The sensor was characterized by transmission electron microscopy and electrochemical impedance spectroscopy, and its electrochemical properties by cyclic voltammetry, chronocoulometry and differential pulse voltammetry. The GO/MWCNT hybrid exhibits strong catalytic activity toward the oxidation of L-tyrosine, with a well defined oxidation peak at 761 mV. The respective current serves as the analytical information and is proportional to the L-tyrosine concentration in two ranges of different slope (0.05 to 1.0 μM and 1.0 to 650.0 μM), with limits of detection and quantification as low as 4.4 nM and 14.7 nM, respectively. The method was successfully applied to the analysis of L-tyrosine in human body fluids. The excellent reproducibility, stability, sensitivity and selectivity are believed to be due to the combination of the electrocatalytic properties of both GO and MWCNT. They are making this hybrid electrode a potentially useful electrochemical sensing platform for bioanalysis. Figure
A new L-tyrosine electrochemical sensor was fabricated based on graphene oxide and multiwalled carbon nanotube. The prepared sensor exhibits excellent electro-catalysis to the oxidation of L-tyrosine, and can improve determination sensitivity and decrease detection limit. This sensor was successfully applied to detect L-tyrosine in human fluids with satisfactory results. 相似文献
6.
Lei Yan Yang Fan Li Yu-Tao Tang Lina Chen Keli Zhang Guo-Jun 《Mikrochimica acta》2017,184(7):2299-2305
Microchimica Acta - The authors describe the construction of a renewable electrochemical method for determination of honokiol in complex traditional Chinese herbs. A nanocomposite consisting of... 相似文献
7.
Ye Yongkang Gao Jiaona Zhuang Hao Zheng Haisong Sun Hanju Ye Yingwang Xu Xuan Cao Xiaodong 《Mikrochimica acta》2017,184(1):245-252
Microchimica Acta - The authors describe an electrochemical DNA biosensor based on a glassy carbon electrode modified with gold nanoparticles (AuNPs) and reduced graphene oxide that was... 相似文献
8.
Core-shell Au@Ag nanorods (Ag@GNRs) were synthesized and utilized to construct a voltammetric biosensor for trichloroacetic acid (TCA). The biosensor was prepared by immobilizing hemoglobin (Hb) on a glassy carbon electrode (GCE) that was modified with the Ag@GNRs. Cyclic voltammetry revealed a pair of symmetric redox peaks, indicating that direct electron transfer occurs at the Hb on the Ag@GNR-film. The electron transfer rate constant is as high as 2.32 s?1. The good electrocatalytic capability and large surface area of the Ag@GNR-film is beneficial in terms of electron transfer between Hb and the underlying electrode. The modified GCE, best operated at ?0.4 V (vs. SCE), exhibits electrocatalytic activity toward TCA in the 0.16 μM to 1.7 μM concentration range, with a 0.12 μM detection limit (at an S/N ratio of 3). 相似文献
9.
JIN Li-Tong ZHAO Gui-Zhu FANG Yu-ZhiDepartment of Chemistry East China Normal University Shanghai China 《中国化学》1994,12(4):343-347
Cholesterol oxidase biosensor has been constructed by using bovine serum albumin and glutaraldehyde as cross linker to immobilize cholesterol oxidase and cholesterol esterase on a glassy carbon electrode modified with Nafion and methyl viologen. The biosensor has been used to determine total cholesterol in blood. The linear range of the determination is 2.5×10~7 to 1.0×10-4 mol/L. The detection limit is about 5.0×10~8 mol/L. The response time is 12 s. This biosensor has the advantage of high selectivity, sensitivity and short response time. 相似文献
10.
We report on a nonenzymatic glucose sensor based on a glassy carbon electrode that was electrochemically modified with a nanocomposite prepared from nickel hydroxide and graphene. Scanning electron microscopy revealed that the nickel hydroxide in the nanocomposite was present in the form of a nanostructure of three-dimensional spheres that were assembled by many densely arranged nanosheets. The electrocatalytic activity of the electrode toward the oxidation of glucose was investigated by chronoamperometry. The current response was linearly related to the glucose concentration in the range from 1 to 10?μM, with a sensitivity of 494?μA?mM–1?cm–2 and a correlation coefficient of 0.9990, and a second range (from 10 to 1000?μM with a sensitivity of 328?μA?mM–1?cm–2 and a correlation coefficient of 0.9990). The detection limit was 0.6?μM at a signal-to-noise ratio of 3, and the response time was as short as 2?s. Figure
As seen in the scanning electron microscopic image, three-dimension Ni(OH)2 spheres was decorated on the surface of graphene. Due to its excellent electrochemical properties and large specific surface area, the addition of graphene obviously promoted the current response to glucose at the Ni(OH)2 modified electrode. 相似文献
11.
An amperometric sensor for L-Cys is described which consists of a glassy carbon electrode (GCE) that was modified with reduced graphene oxide placed in a Nafion film and decorated with palladium nanoparticles (PdNPs). The film was synthesized by a hydrothermal method. The PdNPs have an average diameter of about 10 nm and a spherical shape. The modified GCE gives a linear electro-oxidative response to L-Cys (typically at +0.6 V vs. SCE) within the 0.5 to 10 μM concentration range. Other figures of merit include a response time of less than 2 s, a 0.15 μM lower detection limit (at signal to noise ratio of 3), and an analytical sensitivity of 1.30 μA·μM?1·cm?2. The sensor displays selectivity over ascorbic acid, uric acid, dopamine, hydrogen peroxide, urea, and glucose. The modified GCE was applied to the determination of L-Cys in human urine samples and gave excellent recoveries. 相似文献
12.
13.
Su-Juan Li Guo-Yan Zhao Rong-Xia Zhang Ya-Li Hou Lin Liu Huan Pang 《Mikrochimica acta》2013,180(9-10):821-827
We describe a highly sensitive and selective amperometric sensor for the determination of nitrite. A glassy carbon electrode was modified with a composite made from gold nanoparticles (AuNPs) and sulfonated graphene (SG). The modified electrode displays excellent electrocatalytic activity in terms of nitrite oxidation by giving much higher peak currents (at even lower oxidation overpotential) than those found for the bare electrode, the AuNPs-modified electrode, and the SG-modified electrode. The sensor has a linear response in the 10 μM to 3.96 mM concentration range, a very good detection sensitivity (45.44 μA mM?1), and a lower detection limit of 0.2 μM of nitrite. Most common ions and many environmental organic pollutants do not interfere. The sensor was successfully applied to the determination of nitrite in water samples, and the results were found to be consistent with the values obtained by spectrophotometry. Figure
A highly sensitive amperometric sensor for nitrite using a glassy carbon electrode modified with gold nanoparticles/sulfonated graphene (AuNPs/SG) composites is presented 相似文献
15.
16.
Hussain Mohammad Musarraf Rahman Mohammed M. Asiri Abdullah M. 《Mikrochimica acta》2016,183(12):3265-3273
Microchimica Acta - Strontium oxide nanorods (SrO NR) were prepared in alkaline medium by a wet-chemical method. They were characterized by FTIR, UV/Vis, field emission scanning electron... 相似文献
17.
Microchimica Acta - The authors describe a method for room temperature preparation of reduced graphene oxide (rGO) decorated with Ag-Cu nanoparticles (NPs). The nanocomposite (Ag-CuNP/rGO) was... 相似文献
18.
聚L-丝氨酸修饰电极伏安法测定对乙酰氨基酚 总被引:4,自引:1,他引:3
对乙酰氨基粉(扑热息痛)为芳环对位取代的酰氨类药物,有解热、镇痛作用。临床上广泛用于感冒发烧、关节痛、神经痛及偏头痛、癌性痛及手术后止痛[1]。但过多服用对乙酰氨基酚对人体会造成伤害,对消化系统的影响主要表现为恶心、呕吐、压食、出汗、腹痛等症状;对泌尿系统、血液系统、呼吸系统都有影响,还能使对阿司匹灵过敏患者的支气管痉挛加重,严重时会抑制呼吸中枢。因此建立对乙酰氨基酚的灵敏检测方法是非常必要的。当前用于检测对乙酰氨基酚的方法主要有滴定法[2]、分光光度法[3]、高效液相色谱法[4]、毛细管电泳[5]、荧光法[6]以及电… 相似文献
19.
Yusoff Norazriena Rameshkumar Perumal Shahid Muhammad Mehmood Huang Sheng-Tung Huang Nay Ming 《Mikrochimica acta》2017,184(9):3291-3299
Microchimica Acta - The authors show that the electrocatalytic performance toward the detection of nitric oxide (NO) can be enhanced by making use of gold nanoparticles (AuNP) in a matrix... 相似文献