共查询到20条相似文献,搜索用时 15 毫秒
1.
Shafiquzzaman Siddiquee Nor Azah Yusof Abu Bakar Salleh Soon Guan Tan Fatimah Abu Bakar 《Journal of Solid State Electrochemistry》2012,16(1):273-282
Electrochemical DNA biosensor was successfully developed by depositing the ionic liquid (e.g., 1-ethyl-3-methylimidazolium
trifluoromethanesulfonate ([EMIM][Otf])), ZnO nanoparticles, and chitosan (CHIT) nanocomposite membrane on a modified gold
electrode (AuE). The electrochemical properties of the [EMIM][Otf]/ZnO/CHIT/AuE for detection of DNA hybridization were studied.
Under optimal conditions using cyclic voltammetry, the target DNA sequences could be detected in the concentration range of
1.0 × 10−18 to 1.82 × 10−4 mol L−1, and with the detection limit of 1.0 × 10−19 mol L−1. This DNA biosensor detection approaches provide a quick, sensitive, and convenient method to be used in the identification
of Trichoderma harzianum. 相似文献
2.
We describe the fabrication of a sensitive label-free electrochemical biosensor for the determination of sequence-specific target DNA. It is based on a glassy carbon electrode (GCE) modified with graphene, gold nanoparticles (Au-NPs), and polythionine (pThion). Thionine was firstly electropolymerized on the surface of the GCE that was modified with graphene by cyclic voltammetry. The Au-NPs were subsequently deposited on the surface of the pThion/graphene composite film by adsorption. Scanning electron microscopy and electrochemical methods were used to investigate the assembly process. Differential pulse voltammetry was employed to monitor the hybridization of DNA by measuring the changes in the peak current of pThion. Under optimal conditions, the decline of the peak current is linearly related to the logarithm of the concentration of the target DNA in the range from 0.1 pM to 10 nM, with a detection limit of 35 fM (at an S/N of 3). The biosensor exhibits good selectivity, acceptable stability and reproducibility. Figure
A label-free DNA biosensor based on Au-NPs/pThion/graphene modified electrode has been fabricated. Differential pulse voltammetry (DPV) was employed to monitor DNA hybridization event by measurement of the peak current changes of pThion. 相似文献
3.
We have developed a new immunological biosensor for ultrasensitive quantification of human epidermal growth factor receptor-3(HER-3). In order to construct the biosensor, the gold electrode surface was layered with, hexanedithiol, gold nanoparticles, and cysteamine, respectively. Anti-HER-3 antibody was covalently attached to cysteamine by glutaraldehyde and used as a bioreceptor in a biosensor system for the first time by this study. Surface characterization was obtained by means of electrochemical impedance spectroscopy and voltammetry. The proposed biosensor showed a good analytical performance for the detection of HER-3 ranging from 0.2 to 1.4 pg mL−1. Kramers–Kronig transform was performed on the experimental impedance data. Moreover, in an immunosensor system, the single frequency impedance technique was firstly used for characterization of interaction between HER-3 and anti-HER-3. Finally the presented biosensor was applied to artificial serum samples spiked with HER-3. 相似文献
4.
We report on the modification of a glassy carbon electrode with a composite consisting of silver nanoparticles (AgNPs), polydopamine, and graphene to give an electrochemical sensor for catechol. The composite was characterized by transmission electron microscopy, and the electrochemical behavior of catechol at the modified electrode was studied by cyclic voltammetry. The electrochemical response is greatly enhanced and thought to result from a combination of beneficial effects including the good conductivity and large surface area of the AgNPs, the high conductivity of graphene, the synergistic effects of the composite, and the increased quantity of catechol that is adsorbed on the surface of the electrode. Differential pulse voltammetric responses are proportional to the concentration of catechol between 0.5 and 240?μM levels of catechol, and the detection limit is 0.1?μM (S/N?=?3). The performance of the sensor was evaluated with catechol-spiked water samples, and recoveries range from 96.5 % to 103.1 %. The results indicated that the composite presented here is a promising substrate for use in electrochemical sensing. Graphical abstract
We report on the modification of a glassy carbon electrode with a composite consisting of silver nanoparticles, polydopamine, and graphene to obtain an electrochemical sensor for catechol. 相似文献
5.
Electrochemical immunosensor for carcinoembryonic antigen based on antigen immobilization in gold nanoparticles modified chitosan membrane. 总被引:1,自引:0,他引:1
A disposable electrochemical immunosensor for carcinoembryonic antigen (CEA) was proposed based on the antigen immobilized in a colloidal gold nanoparticles modified chitosan membrane on the surface of an indium-tin oxide (ITO) electrode. The different membranes were characterized by scanning electron microscope and electrochemical methods. Based on a competitive immunoassay format, the immobilized antigen of the immunosensor was incubated with a horseradish peroxidase (HRP) labeled antibody and sample CEA antigen, and the formed immunoconjugate in the immunosensor was detected by an o-phenylenediamine-H(2)O(2)-HRP electrochemical system. Under the optimal experimental conditions, the electrocatalytic current decreased linearly with the competitive mechanism. CEA could be determined in the linear range from 2.0 to 20 ng/ml with a detection limit of 1.0 ng/ml. The prepared CEA immunosensor is not only economic due to the low-cost ITO electrode obtained from industrial mass production, but is also capable with good stability and reproducibility for batch fabrication. 相似文献
6.
A novel electrode was prepared that enables sensing of lead(II) ion. A suspension composed of ordered mesoporous carbon (OMC), an ionic liquid (IL), and chitosan was deposited on the highly conductive surface of a carbon ionic-liquid electrode (CILE). The surface of the sensing electrode was characterized by scanning electron microscopy and cyclic voltammetry. The new electrode can be used to determine lead(II) ion because the hydrophobic ionic liquid of the CILE can extract Pb(II), while the OMC accelerates the electron transfer rate between the electrode and Pb(II) and also strongly adsorbs Pb(II). The resulting electrode displays excellent and synergistic response to Pb(II) which is linear in the range from 0.05 to 1.4?μM, with a correlation coefficient of 0.997 and a detection limit of 25 nM. Figure
Differential pluse anodic stripping voltammograms of 5.0?×?10?7?M Pb2+ at (1) CPE (2) CILE, (3) OMC-chitosan/CILE, (4) IL2-chitosan/CILE and (5) OMC-IL2-chitosan/CILE in 10?mM HNO3. Accumulation potential: -1.05?V, accumulation time 200?s, pulse amplitude: 50?mV, pulse width: 50?ms. 相似文献
7.
Xiaofeng Wang Zheng You Hailiang Sha Zhaolan Sun Wei Sun 《Journal of Solid State Electrochemistry》2014,18(1):207-213
In this paper, a Fe3O4@SiO2 core-shell structure microsphere was synthesized and used to investigate the direct electron transfer of myoglobin (Mb) with a 1-butylpyridinium hexafluorophosphate based carbon ionic liquid electrode (CILE) as the substrate electrode. The mixture of Mb and Fe3O4@SiO2 microsphere could form an organic–inorganic composite, which was immobilized on the surface of CILE with a chitosan (CS) film. Cyclic voltammetric experiments indicated that a pair of well-defined quasi-reversible redox peaks appeared on CS/Mb-Fe3O4@SiO2/CILE with the formal peak potential (E 0′) located at ?0.31 V (vs. saturated calomel electrode), which was corresponded to the electroactive center of Mb heme Fe(III)/Fe(II) redox couples. Direct electrochemical behaviors of Mb in CS-Fe3O4@SiO2 composite film were carefully investigated with the electrochemical parameters calculated. The CS/Mb-Fe3O4@SiO2/CILE showed good electrocatalytic behaviors to the reduction of trichloroacetic acid in the concentration range from 0.2 to 11.0 mmol L?1 with the detection limit of 0.18 mmol L?1 (3σ). Based on CS/Mb-Fe3O4@SiO2/CILE, a new third-generation reagentless electrochemical biosensor was constructed with higher sensitivity and reproducibility. 相似文献
8.
The electrochemical detection of sequence-specific DNA using a DNA probe labeled with aminoferrocene (AFC) is reported. Sample ssDNA was immobilized on a chitosan modified glassy carbon electrode. A sequence-known DNA with 256 bp [obtained by polymerase chain reaction (PCR)] was successfully labeled with the electro-active reagent AFC by 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide for the first time. This DNA probe labeled with AFC was applied to hybridize with a sequence-unknown DNA sample. Only the complementary sequence (cDNA) could form a double-stranded DNA (dsDNA) with the DNA probe labeled with AFC. The anodic peak currents (ipa) of the AFC bound to the dsDNA by differential pulse voltammetry were used for the determination of cDNA. The ipa of AFC was linearly related to the concentration of cDNA sequence between 1.0 x 10(-8) and 6.0 x 10(-6) mol L-1. The detection limit was 2.0 x 10(-9) mol L-1 using 3 sigma (where sigma is the standard deviation of blank solution, n = 11). The probe showed high sensitivity and selectivity. 相似文献
9.
10.
We describe a sensitive chronocoulometric biosensor for the sequence-specific detection of DNA. It is based on a glassy carbon electrode modified with multi-walled carbon nanotubes, polydopamine, and gold nanoparticles. The ruthenium(III)hexammine complex acts as the electrochemical indicator. Electrochemical impedance spectra and scanning electron microscopy are employed to investigate the assembly of the electrode surface. The signals of the ruthenium complex electrostatically bound to the anionic phospho groups of the DNA strands are measured by chronocoulometry before and after hybridization. The difference in signal intensity is linearly related to the logarithm of the concentration of the target DNA in the range of 1.0 nM to 10 fM with a detection limit of 3.5fM (S/N?=?3) under optimal conditions. This biosensor exhibits excellent sensitivity and selectivity and has been used for an assay of complementary target DNA in human serum sample with satisfactory results. Figure
We describe a sensitive chronocoulometric biosensor based on a glassy carbon electrode modified with gold nanoparticles, poly(dopamine), and carbon nanotubes. The biosensor exhibits excellent sensitivity and selectivity and has been used for an assay of Helicobacter pylori in human serum with a satisfactory result. 相似文献
11.
Morita K Sankaran NB Huang W Seino T Sato Y Nishizawa S Teramae N 《Chemical communications (Cambridge, England)》2006,(22):2376-2378
An abasic site-containing DNA combined with lumiflavin allows amperometric determination of single nucleotide polymorphism through hydrogen bond-mediated nucleobase recognition in water by using abasic sites as a molecular recognition field. 相似文献
12.
An electrochemical DNA biosensor was fabricated by self-assembling probe single-stranded DNA (ssDNA) with a nanogold decorated on ionic liquid modified carbon paste electrode (IL-CPE). IL-CPE was fabricated using 1-butylpyridinium hexafluorophosphate as the binder and the gold nanoparticles were electrodeposited on the surface of IL-CPE (Au/IL-CPE). Then mercaptoacetic acid was self-assembled on the Au/IL-CPE to obtain a layer of modified film, and the ssDNA probe was further covalently-linked with mercaptoacetic acid by the formation of carboxylate ester with the help of N-(3-dimethylamino-propyl)-N'-ethylcarbodiimide hydrochloride and N-hydroxysuccinimide. The hybridization reaction with the target ssDNA was monitored with methylene blue (MB) as the electrochemical indicator. Under the optimal conditions, differential pulse voltammetric responses of MB was proportional to the specific ssDNA arachis sequences in the concentration range from 1.0×10(-11) to 1.0×10(-6) mol L(-1) with the detection limit as 1.5×10(-12) mol L(-1) (3σ). This electrochemical DNA sensor exhibited good stability and selectivity with the discrimination ability of the one-base and three-base mismatched ssDNA sequences. The polymerase chain reaction product of arachis Arabinose operon D gene was successfully detected by the proposed method, which indicated that the electrochemical DNA sensor designed in this paper could be further used for the detection of specific ssDNA sequence. 相似文献
13.
We report on a novel hydrogen peroxide biosensor that was fabricated by the layer-by-layer deposition method. Thionine was first deposited on a glassy carbon electrode by two-step electropolymerization to form a positively charged surface. The negatively charged gold nanoparticles and positively charged horseradish peroxidase were then immobilized onto the electrode via electrostatic adsorption. The sequential deposition process was characterized using electrochemical impedance spectroscopy by monitoring the impedance change of the electrode surface during the construction process. The electrochemical behaviour of the modified electrode and its response to hydrogen peroxide were studied by cyclic voltammetry. The effects of the experimental variables on the amperometric determination of H2O2 such as solution pH and applied potential were investigated for optimum analytical performance. Under the optimized conditions, the biosensor exhibited linear response to H2O2 in the concentration ranges from 0.20 to 1.6?mM and 1.6 to 4.0?mM, with a detection limit of 0.067?mM (at an S/N of 3). In addition, the stability and reproducibility of this biosensor was also evaluated and gave satisfactory results. Figure
A novel hydrogen peroxide biosensor was fabricated via layer-by-layer depositing approach. Thionine was first deposited on a glassy carbon electrode by electropolymerization to form a positively charged surface (PTH). Negatively charged gold nanoparticles (NPs) and positively charged horseradish peroxidase (HRP) were then immobilized onto the electrode via electrostatic adsorption. 相似文献
14.
15.
Electrochemical study and detection of perphenazine using a gold electrode modified with decanethiol SAM 总被引:1,自引:0,他引:1
A novel method for the determination of perphenazine has been developed. The method is based on the accumulation of perphenazine at a gold electrode modified with decanethiol (DEC) self-assembled monolayer (SAM) and its oxidation at about 0.6 V (vs. saturated calomel electrode (SCE)). Because some coexistent electroactives were blocked and perphenazine was selectively accumulated by the SAM, the electrode exhibited good selectivity and sensitivity. Various conditions were optimized for practical application. Under the selected conditions (i.e. 0.05 M pH 10 sodium borate buffer, accumulation time: 120 s, accumulation potential: −0.4 V, scan rate: 100 mV s−1), the anodic stripping peak current was linear to perphenazine concentration in the ranges of 6×10−9–5×l0−7 and 5×10−7–5×10−6 M with correlation coefficients of 0.998 and 0.995, respectively. For a 1.0×10−6 M perphenazine solution, the relative standard deviation of peak height was 2.3% (n=8). This method was applied to the determination of perphenazine in some drugs and the recovery was 92–101%. In addition, it was found that in the presence of perphenazine, the SAM structure changed a little and more needle holes appeared. However, the SAM could recover the original form when perphenazine and its redox product were removed from the monolayer by repeatedly cycling the electrode in a blank solution for a minute. The modified electrode was characterized by alternating current impedance and electrochemical probe. 相似文献
16.
For the first time, a new platform based on electrochemical growth of Au nanoparticles on aligned multi-walled carbon nanotubes (A-MWCNT) was developed for sensitive lable-free DNA detection of the TP53 gene mutation, one of the most popular genes in cancer research. Electrochemical impedance spectroscopy (EIS) was used to monitor the sequence-specific DNA hybridization events related to TP53 gene. Compared to the bare Ta or MWCNT/Ta electrodes, the synergistic interactions of vertically aligned MWCNT array and gold nanoparticles at modified electrode could improve the density of the probe DNA attachment and resulting the sensitivity of the DNA sensor greatly. Using EIS, over the extended DNA concentration range, the change of charge transfer resistance was found to have a linear relationship in respect to the logarithm of the complementary oligonucleotides sequence concentrations in the wide range of 1.0 × 10−15 − 1.0 × 10−7 M, with a detection limit of 1.0 × 10−17 M (S/N = 3). The prepared sensor also showed good stability (14 days), reproducibility (RSD = 2.1%) and could be conveniently regenerated via dehybridization in hot water. The significant improvement in sensitivity illustrates that combining gold nanoparticles with the on-site fabricated aligned MWCNT array represents a promising platform for achieving sensitive biosensor for fast mutation screening related to most human cancer types. 相似文献
17.
We have developed an enzymatic glucose biosensor that is based on a flat platinum electrode which was covered with electrophoretically deposited rhodium (Rh) nanoparticles and then sintered to form a large surface area. The biosensor was obtained by depositing glucose oxidase (GOx), Nafion, and gold nanoparticles (AuNPs) on the Rh electrode. The electrical potential and the fractions of Nafion and GOx were optimized. The resulting biosensor has a very high sensitivity (68.1 μA mM?1 cm?2) and good linearity in the range from 0.05 to 15 mM (r?=?0.989). The limit of detection is as low as 0.03 mM (at an SNR of 3). The glucose biosensor also is quite selective and is not interfered by electroactive substances including ascorbic acid, uric acid and acetaminophen. The lifespan is up to 90 days. It was applied to the determination of glucose in blood serum, and the results compare very well with those obtained with a clinical analyzer. Figure
An enzymatic glucose biosensor was prepared based on rhodium nanoparticle modified Pt electrode and glucose oxidase immobilized in gold nanoparticles and Nafion composite film. The electrode showed a good response to glucose. The sensor was applied to the determination of glucose in blood serum. 相似文献
18.
A composite film modified glassy carbon electrode (GCE) fabricated with spinning coating of multiwalled carbon nano-tube (MWNT)
/1-butyl-3-methylimidazolium tetrafluoroborate/chitosan sol was developed for the electrochemical determination of 4-nitrophenol
(4-NP). An obvious reduction peak located at about −0.688 V was observed with voltammetric measurements in the potential range
from 0.200 V to −1.00 V. Compared with the bare GCE, the reduction peak potential shifted positively and the peak current
increased significantly. All experimental parameters for the determination of 4-NP were optimized. It was found that the reduction
peak current was proportional to 4-NP concentration in the range from 3.00 × 10−7 to 2.00 × 10−5 mol l−1 with the detect limitation of 1.00 × 10−7 mol l−1 (S/N = 3) after accumulation for 90 s. The proposed method was successfully applied for the determination of trace amounts
of 4-NP in lake water. 相似文献
19.
A sulfite oxidase (SOx) purified from leaves of Syzygium cumini (Jamun) was immobilized covalently onto a gold nanoparticles (AuNPs)/chitosan (CHIT)/carboxylated multiwalled carbon nanotubes
(cMWCNTs)/polyaniline (PANI) composite that was electrodeposited onto the surface of a gold (Au) electrode. A novel and highly
sensitive sulfite biosensor was developed that used this enzyme electrode (SOx/AuNPs/CHIT/cMWCNT/PANI/Au) as the working electrode,
Ag/AgCl as the standard electrode, and Pt wire as the auxiliary electrode. The modified electrode was characterized by Fourier
transform infrared (FTIR) spectroscopy, cyclic voltammetry (CV), scanning electron microscopy (SEM), and electrochemical impedance
spectroscopy (EIS) before and after the immobilization of the SOx. The sensor produced its optimum response within 3 s when
operated at 50 mVs−1 in 0.1 M phosphate buffer, pH 7.0, and at 35 °C. The linear range and detection limit of the sensor were 0.75–400 μM and
0.5 μM (S/N = 3), respectively. The biosensor was employed to determine sulfite levels in fruit juices and alcoholic beverages.
The enzyme electrode was used 300 times over a period of three months when stored at 4 °C. 相似文献
20.
A novel voltammetric sensor, based on DNA immobilized on the surface of an ethylenediamine/polyglutamic (En/PGA) modified glassy carbon electrode (GCE), was constructed and used for determination of dihydromyricetin (DMY). The electrochemical behaviour of DMY at this sensor was investigated in pH 3.6 NaAc-HAc buffer solutions by cyclic voltammetry (CV) and differential pulse anodic voltammetry (DPV). The oxidation of DMY is an adsorption-controlled irreversible process. The oxidation mechanism was proposed and discussed. It was found that the modified electrode exhibited a linear voltammetric response for DMY in the range of 4.0 × 10(-8) mol L(-1) to 2 × 10(-6) mol L(-1), with a detection limit of 2 × 10(-8) mol L(-1). The method was also applied successfully to detect DMY in an ampelopsis sample with satisfactory results. 相似文献