首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel composite electrode has been developed using electrospun carbon nanofibers (CNF) and the ionic liquid 1-butyl-4-methylpyridinium hexaflurophosphate (PFP). The highly pure CNF without any pretreatment exhibited very low background noise and high voltammetric responses. When applied to sensing of biomolecules under physiological conditions, the CNF/PFP electrode provided attractive electrochemical performances, such as high sensitivity and good selectivity for simultaneous detection of dopamine, ascorbic acid and uric acid, guanine and adenine, as well as high signal-to-noise ratio and good stability for amperometric detection of NADH.  相似文献   

2.
A novel amperometric immunosensor for the determination of alpha-fetoprotein (AFP) was constructed using films of multi-wall carbon nanotubes/DNA/thionine/gold nanoparticles (nano-Au). Firstly, multi-wall carbon nanotubes (MWCNT) dispersed in poly(diallydimethlammonium chloride) (PDDA) were immobilized on the nano-Au film which was electrochemically deposited on the surface of glassy carbon electrode. Then a negatively charged DNA film was absorbed on the positively charged PDDA. Subsequently, thionine was attached to the electrode via the electrostatic interaction between thionine and the DNA. Finally, the nano-Au was retained on the thionine film for immobilization of AFP antibody (anti-AFP). The modification process was characterized by cyclic voltammetry (CV) and scanning electron microscope (SEM). The factors possibly influenced the performance of the proposed immunosensors were studied in detail. Under optimal conditions, the proposed immunosensor exhibited good electrochemical behavior to AFP in a two concentration ranges: 0.01–10.0 and 10.0–200.0 ng/mL with a relatively low detection limit of 0.04 ng/mL at three times the background noise. Moreover, the selectivity, repeatability and stability of the proposed immunosensor were acceptable.  相似文献   

3.
4.
5.
Yang  Yang  Fu  Renzhong  Yuan  Jianjun  Wu  Shiyuan  Zhang  Jialiang  Wang  Haiying 《Mikrochimica acta》2015,182(13):2241-2249

We are presenting a sensor for hydrogen peroxide (H2O2) that is based on the use of a heterostructure composed of Pt nanoparticles (NPs) and carbon nanofibers (CNFs). High-density Pt NPs were homogeneously loaded onto a three-dimensional nanostructured CNF matrix and then deposited in a glassy carbon electrode (GCE). The resulting sensor synergizes the advantages of the conducting CNFs and the nanoparticle catalyst. The porous structure of the CNFs also favor the high-density immobilization of the NPs and the diffusion of water-soluble molecules, and thus assists the rapid catalytic oxidation of H2O2. If operated at a working voltage of −0.2 V (vs. Ag/AgCl), the modified GCE exhibits a linear response to H2O2 in the 5 μM to 15 mM concentration range (total analytical range: 5 μM to 100 mM), with a detection limit of 1.7 μM (at a signal-to-noise ratio of 3). The modified GCE is not interfered by species such as uric acid and glucose. Its good stability, high selectivity and good reproducibility make this electrode a valuable tool for inexpensive amperometric sensing of H2O2.

The Pt NPs/CNF heterostructure-based H2O2 sensor synergizes the advantages of both the conducting carbon nanofibers and the nanoparticle catalyst. The 3D structure of the nanofibers favor high density immobilization of the nanoparticles and penetration by water-soluble molecules, which assists the catalyic oxidation of H2O2. The sensor shows outstanding performance in terms of detection range, detection limit, response time, stability and selectivity.

  相似文献   

6.
利用离子液体1-丁基-3-甲基咪唑四氟硼酸盐(BMIMBF4)对玻碳电极(GCE)进行修饰,制备了BMI-MBF4/GCE电极.在0.1mol/L的磷酸盐缓冲溶液中,采用循环伏安法研究了抗坏血酸在BMIMBF4/GCE电极和裸玻碳电极(GCE)上的电化学行为.结果表明,pH=5.7的磷酸盐缓冲溶液为最佳测定底液,最佳富集时间为120s;BMIMBF4/GCE对抗坏血酸的氧化反应有很好的电化学催化作用.抗坏血酸的氧化峰电流与其浓度在2.0×10-4~1.0×10-2 mol/L的范围内呈良好的线性关系,相对标准偏差为4.53%(n=5).  相似文献   

7.
M Liu  L Wang  J Deng  Q Chen  Y Li  Y Zhang  H Li  S Yao 《The Analyst》2012,137(19):4577-4583
A new ferrocene derivative (1-[(4-amino) phenylethynyl]ferrocene, Fc-NH(2)) was synthesized for the first time. The ferrocene derivative molecule contained the phenylethynyl skeleton, ferrocene and amino groups with excellent electrochemical properties. The graphene/Fc-NH(2) nanocomposite was prepared by mixing graphene solution and Fc-NH(2) solution in one pot and the nanocomposite was utilized to construct a Nafion/graphene/Fc-NH(2) modified glassy carbon electrode (GCE). The ferrocene derivative immobilized on the graphene can enhance the charge-transport ability of the nanocomposite, stabilize the graphene and prevent the leakage of ferrocene. The detection signal of dopamine (DA) was significantly amplified on the Nafion/graphene/Fc-NH(2)/GCE. It was experimentally demonstrated that the signal enhancement results from the synergy amplification effect of graphene and the Fc-NH(2). The oxidation peak currents of DA were linearly related to the concentrations in the range of 5 × 10(-8) to 2 × 10(-4) M with the detection limit of 20 nM in the absence of uric acid (UA) and ascorbic acid (AA). In the presence of 10(-3) M AA and 10(-4) M UA, the linear response range was 1 × 10(-7) to 4 × 10(-4) M, and the detection limit was 50 nM at S/N = 3. Using the proposed Nafion/Fc-NH(2)/graphene/GCE, DA was successfully determined in real samples with the standard addition method.  相似文献   

8.
The ionic liquid 1-{3-[(2-aminoethyl)amino]propyl}-3-vinylimidazole bromide was synthesized and used to fabricate a molecularly imprinted film for electrochemical sensing of myoglobin (Myo). This film was deposited on a glassy carbon electrode modified with multi-walled carbon nanotubes by using the ionic liquid as the functional monomer, Myo as the template, N,N′-methylenebisacrylamide as the crosslinker, and a redox system containing ammonium persulfate and N,N,N′,N′-tetramethylethylenediamine as the initiator. The sensing performance of the modified electrode was investigated by using the hexacyanoferrate system as an electrochemical redox probe. The results demonstrated that the sensor possesses good selectivity and high sensitivity. The oxidation peak current at the potential of ~0.3 V (vs. SCE) was found linearly related to the myoglobin concentration in the range from 60.0 nM to 6.0 μM, with a 9.7 nM detection limit at an S/N ratio of 3. The sensor was applied to the determination of Myo in spiked serum samples where it showed average recoveries (for n = 5) of 96.5 %.
Graphical abstract By using a polymerizable ionic liquid as the functional monomer, a myoglobin imprinted polymer was fabricated on a multi-walled carbon nanotube modified glassy carbon electrode. The sensing performances of the molecularly imprinted sensor towards myoglobin demonstrated good selectivity, sensitivity and accuracy.
  相似文献   

9.
研究了在PBS缓冲介质中,一种检测癌胚抗原的新型免标记免疫电化学传感器的制备,将石墨烯、二茂铁的高效催化及壳聚糖的优良生物相容性和成膜性、离子液体的导电性等优势充分结合构建了电化学免疫传感器。通过循环伏安法及交流阻抗对修饰的电极进行表征,在最优条件下,癌胚抗原的质量浓度在0.2~50.0 ng/mL的范围内与差分脉冲伏安法峰电流呈良好的线性关系,回归方程为Δi=0.38-1.31ρ,相关系数分别为0.9967,检测限为0.06 ng/mL,该传感器可用于人血清样品的测定。  相似文献   

10.
An amperometric carcinoembryonic antigen (CEA) immunosensor was fabricated based on Prussian blue (PB), nano-calcium carbonate (nano-CaCO3) and nano-gold modified glassy carbon electrode. First, PB as a mediator was deposited on glassy carbon electrode to obtain a negatively charged surface. Then, positive nano-CaCO3 was adsorbed on the PB modified electrode through electrostatic interaction. Subsequently, gold nanoparticles were deposited on the nano-CaCO3/PB modified electrode. The use of two kinds of nanomaterials (nano-CaCO3 and nano-gold) with good biocompatibility as immobilization matrixes not only provides a biocompatible surface for protein loading but also avoids the leaking of PB. The size of nano-CaCO3 was characterized by transmission electron microscopy (TEM). The factors influencing the performance of the immunosensor presented were studied in detail. Under the optimized conditions, cyclic voltammograms (CV) determination of CEA showed a specific response in two concentration ranges from 0.3 to 20 ng mL?1 and from 20 to 100 ng mL?1 with a detection limit of 0.1 ng mL?1 at a signal-to-noise ratio of 3. The immunosensor presented exhibited high selectivity, sensitivity and good stability.  相似文献   

11.
An immunosensor for determination of salbutamol was developed. It based on glass carbon electrode (GCE) modified with a conductive multilayer film comprised of multi-wall carbon nanotubes, polythionine and gold nanoparticles. Salbutamol antibody was immobilized on the surface of the modified GCE which then was blocked with bovine serum albumin (BSA). The stepwise self-assembly process of the immunosensor was studied by cyclic voltammetry. The detection scheme is based on competitive binding of salbutamol to the sensor surface whose differential pulse voltammetric signal decreases after competitive binding of the salbutamol-BSA conjugate and free salbutamol to the salbutamol antibody. The sensor responds to salbutamol in 5 to 150 nM concentration range, with a detection limit of 1 nM. This method was applied to the precise and sensitive determination of salbutamol in spiked feed samples.
Figure
In this work, we constructed a salbutamol immunosensor which was based on salbutamol-Ab adsorbed on the AuNPs/PTH/MWCNTs/GCE. Just as the procedures shown in Graph 1, competitive immunoreaction was the experimental principle. The percentage of current response of the immunosensor was proportional to salbutamol concentrations in the range of 5–150 nM.  相似文献   

12.
13.
A composite film modified glassy carbon electrode (GCE) fabricated with spinning coating of multiwalled carbon nano-tube (MWNT) /1-butyl-3-methylimidazolium tetrafluoroborate/chitosan sol was developed for the electrochemical determination of 4-nitrophenol (4-NP). An obvious reduction peak located at about −0.688 V was observed with voltammetric measurements in the potential range from 0.200 V to −1.00 V. Compared with the bare GCE, the reduction peak potential shifted positively and the peak current increased significantly. All experimental parameters for the determination of 4-NP were optimized. It was found that the reduction peak current was proportional to 4-NP concentration in the range from 3.00 × 10−7 to 2.00 × 10−5 mol l−1 with the detect limitation of 1.00 × 10−7 mol l−1 (S/N = 3) after accumulation for 90 s. The proposed method was successfully applied for the determination of trace amounts of 4-NP in lake water.  相似文献   

14.
运用循环伏安法研究了双氯芬酸钠(DS)在石墨烯(Gene)和室温离子液体1-丁基-3-甲基咪唑六氟磷酸盐(BMIMPF6)复合修饰电极上的电化学行为。DS在该复合电极上于0.65V处有一不可逆氧化峰。在40~200 mV/s范围内,其氧化峰电流与扫描速率平方根(v1/2)呈良好线性关系,表明电极过程是受扩散控制。测定了部分电极过程参数,优化了方波溶出伏安法(SWSV)的实验参数,DS浓度在1.0×10-7~1.0×10-4mol/L范围内与峰电流Ipa呈良好线性关系,检出限为8.0×10-8mol/L(S/N=3),加标回收率为95.7%~101.7%。  相似文献   

15.
A glassy carbon electrode was modified with PdO-NiO composite nanofibers (PdO-NiO-NFs) and applied to the electrocatalytic reduction of hydrogen peroxide (H2O2). The PdO-NiO-NFs were synthesized by electrospinning and subsequent thermal treatment, and then characterized by scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, and X-ray photoelectron spectroscopy. Factors such as the composition and fraction of nanofibers, and of the applied potential were also studied. The sensor exhibits high sensitivity for H2O2 (583.43 μA?·?mM?1?·?cm?2), a wide linear range (from 5.0 μM to 19 mM), a low detection limit (2.94 μM at an SNR of 3), good long term stability, and is resistant to fouling.
Figure
A glassy carbon electrode was modified with PdO-NiO composite nanofibers which were synthesized by electrospinning and subsequent thermal treatment. The sensor exhibited a wide linear range, high sensitivity, good stability and selectivity for the detection of hydrogen peroxide  相似文献   

16.
17.
Due to the high performance of glassy carbon in the aspects of mechanical strength, electrical conductivity and high corrosion resistance, etc., glassy carbon has been widely used in the electrochemistry. A new form of glassy carbon, glassy carbon microsphere, was utilized to couple with ionic liquid in preparing a new electrochemiluminescent platform for Ru(bpy)3Cl2. Room temperature ionic liquid has been proposed to be very interesting and efficient pasting binder to replace the non conductive organic binders for the fabrication of composite paste electrode. Attributed to the special characteristics of glassy carbon microspheres and room temperature ionic liquid [N-octylpyridium tetrafluoroborate (OPFP)], this new electrochemiluminescent sensor exhibited excellent electrochemiluminescent performance in Ru(bpy)32+ solution. We first found that fentanyl citrate could increase the ECL of Ru(bpy)32+, hence an ECL approach was developed for the determination of fentanyl citrate based on this glassy carbon microspheres based electrochemiluminescent platform with high sensitivity. Under the optimized conditions, the enhanced electrochemiluminescent intensity versus fentanyl citrate concentration was linear in the range of 1.0 × 10−8 to 1.0 × 10−4 mol L−1 with a detection limit of 8.5 × 10−9 mol L−1, and the relative standard deviation for 1.0 × 10−6 mol L−1 fentanyl citrate was 1.90% (n = 10). This protocol has extended the application scopes of glassy carbon material and promoted the application of glassy carbon microspheres in electroanalysis.  相似文献   

18.
The electrochemical properties of Riboflavin adsorbed on carbon ionic liquid electrode (CILE) were studied by cyclic voltammetry. A film with a surface coverage of up to 3.3 × 10−9 mol cm−2 was formed after 10 min exposure time. Electron transfer coefficient and rate constant of electron transfer across the modified electrode were found to be 0.43 and 3.03 s−1, respectively. Differential pulse voltammetry was used for the determination of Riboflavin. Two linear working ranges of 0.8-110 nM and 0.11-1.0 μM were obtained with correlation coefficients of 0.998 and 0.996, respectively. The experimental detection limit was obtained as 0.1 nM. The relative standard deviation for five replicate analyses was 4.7%. Other soluble vitamins had no significant interferences and the electrode was used for the determination of Riboflavin in pharmaceutical products, nutrition and beverages.  相似文献   

19.
A highly selective dopamine quantification at a new polymer-modified electrode in the presence of large excess of ascorbic acid and 3,4-dihydroxyphenyl acetic acid (dopac) is described. The electrochemical detection was performed at a glassy carbon electrode modified with a melanin-type polymer obtained by polymerization of 3.0×10−3 M -dopa in 0.050 M phosphate buffer solution pH 7.40 by applying 1.00 V for 60 min. The polymeric film exhibits attractive permselectivity excluding anionic species such as potassium ferricyanide, ascorbic acid, dopac and uric acid. Cationic species such as epinephrine, norepinephrine and dopamine and neutral ones such as catechol and hydrogen peroxide can be oxidized at the polymer-modified electrode. The use of ascorbic acid in the measurement solution allows the amplification of dopamine oxidation signal due to the reduction of the electrochemically generated dopaminequinone. By using 1.0×10−3 M ascorbic acid, the detection limit for dopamine is 5.0 nM. The interference for the maximum physiological concentrations of ascorbic acid and dopac in nervous centers, i.e. 500 μM ascorbic acid and 50 μM dopac is 8.1 and 1.4%, respectively.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号