首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high pressure matrix-assisted laser desorption/ionization (MALDI) Fourier transform mass spectrometry (FTMS) ion source was designed and tested. With this design, pressure is pulsed to an estimated 1-10 mbar in the region of the MALDI sample during desorption with the result of significantly decreased fragmentation compared to similar systems operating with pressures of <0.1 mbar. The thermal stabilization of vibrationally excited ions under these conditions is shown with small peptides desorbed from the "hot" matrix alpha-cyano-4-hydroxycinnamic acid, and with the highly labile oxidized beta-chain of insulin. Fragile gangliosides with several sialic acid residues are desorbed under high pressure and remain intact without the typical losses of sialic acid, and a protein standard, ubiquitin (8565.64 Da), is desorbed with minimal dehydration. Under high pressure collisional cooling conditions, non-covalent matrix adduction to the molecular ions becomes prominent, but with the trapped ions in an FT mass spectrometer, the ions can be mildly activated to detach the matrix adducts. The new source, additionally, generates significant levels of the multiply charged ions which are commonly seen in MALDI-TOFMS, but are rarely observed in MALDI-FTMS. This effect is more likely due to the elimination of a mass filtering effect in the previous FTMS ion source than to collisional cooling of the ions.  相似文献   

2.
Underivatized and permethylated gangliosides have been studied by the matrix-assisted laser desorption (MALD) ionization technique. The samples investigated included commercially available and highly purified gangliosides from the human brain containing up to five sialic acid residues. Several permethylated gangliosides have also been studied, and MALD has proven successful in analyzing multicomponent mixtures of glycolipids with different fatty acyl residues. During the studies a variety of matrix and wavelength combinations have been tested in both the positive and negative ion modes. The best results have been obtained with the matrices 2,5-dihydroxybenzoic acid, 4-hydrazinobenzoic acid, 1,5-diaminonaphthalene, and 6-aza-2-thiothymine. Negative ion mass spectra of the underivatized gangliosides have always been of better quality than the positive ion mass spectra, exhibiting better signal-to-noise ratio, better resolution, less fragmentation, and less adduct formation with Na+ and K+. With increasing number of sialic acid substituents the molecular ion region became less and less resolvable, leading to broadened peaks even in the negative ion mode. Fragmentation could frequently be observed in the negative ion mode, and it was pronounced in the positive ion mode. The major fragmentation pathways corresponded to loss of sialyl group(s) and to decarboxylation of one of the sialyl residues. For underivatized gangliosides the typical sample amount used was 10–20 pmol. Permethylation led to a significant improvement in sensitivity (two orders of magnitude); the detection limit of permethylated gangliosides was about 10 fmol. The higher stability of the permethylated compounds was indicated by the fact that positive ion mass spectra exhibited only a marginal extent of fragmentation.  相似文献   

3.
A study has been made of the atmospheric-pressure Penning ionization (APPeI) of aliphatic hydrocarbons (pentane, hexane, heptane, and octane) with long-lived rare gas atoms (Rg*). The metastable rare gas atoms (He*, Ne*, Ar* and Kr*) were generated by the negative-mode corona discharge of atmospheric-pressure rare gases. In the Rg*APPeI mass spectra for aliphatic hyrocarbons, the relative abundances of fragment ions were found to increase in the order of He* --> Ne* --> Ar* --> Kr*. The order is in the opposite direction to the internal energies of the Rg*. The less fragmentation observed for He* may be because the nascent molecular ions [M(+.)]* formed by Penning ionization have lifetimes long enough for them to be collisionally deactivated in the atmospheric-pressure ion source. It was found that the relative abundances of fragment ions in Ar*APPeI increased when the sample pressure in the ion source was reduced. This is attributed to the collision of Ar* with molecular ions followed by fragmentation.  相似文献   

4.
An important problem in mass isotopomer abundance mass spectrometry (MIAMS) is the dependence of measured mass isotopomer abundances on sample concentration. We have evaluated the role of ionization energy on mass isotopomer abundance ratios of methyl palmitate as a function of sample concentration. Ionization energy was varied using electron impact ionization (EI) and metastable atom bombardment (MAB). The latter generates a beam of metastable species capable of ionizing analyte molecules by Penning ionization. We observed that ionization of methyl palmitate by EI (70 eV) showed the greatest molecular ion fragmentation and also showed the greatest dependence of relative isotopomer abundance ratios on sample concentration. Ionization using the 3P2 and 3P0 states of metastable krypton (9.92 and 10.56 eV, respectively) resulted in almost no molecular ion fragmentation, and the isotopomer abundances quantified were essentially independent of sample concentration. Ionization using the 3P2 and 3P0 states of metastable argon (11.55 and 11.72 eV, respectively) showed molecular ion fragmentation intermediate between that of EI and MAB(Kr) and showed an isotopomer concentration dependence which was less severe than that observed with EI but more severe than that observed with MAB(Kr). The observed decrease in the dependence of isotopomer abundance on sample concentration with a decrease in molecular ion fragmentation is consistent with the hypothesis that proton transfer from a fragment cation to a neutral molecule is the gas phase reaction mechanism responsible for the concentration dependence. Alternative explanations, e.g., hydrogen abstraction from a neutral molecule to a molecular cation, is not supported by these results. Moreover, the MAB ionization technique shows potential for eliminating one source of error in MIAMS measurements of methyl palmitate, in particular, and of fatty acids methyl esters, in general.  相似文献   

5.
Multistage mass spectrometry, as implemented using low-energy collision-induced dissociation (CID) analysis in three-dimensional (3D) quadrupole ion traps (QITs), has become a powerful tool for the investigation of protein glycosylation. In addition to the well-known combination of QITs with electrospray ionization (ESI), also a matrix-assisted laser desorption/ionization--quadrupole ion trap--reflectron time-of-flight (MALDI-QIT-rTOF) mass spectrometer has recently become available. This study systematically investigates the differences between these types of instrument, as applied to characterization of glycopeptides from human antithrombin. The glycopeptides were obtained by tryptic digestion followed by lectin-affinity purification. Some significant differences between the ESI-QIT and MALDI-QIT-rTOF approaches appeared, most of them are causally related to the desorption/ionization process. The combination of a vacuum MALDI source with an ion-trap analyzer accentuates some characteristic differences between MALDI and ESI due the longer time frame needed for the trapping process. In contrast to ESI, MALDI generated ions that exhibited considerable metastable fragmentation during trapping. The long time span of the QIT process (ms range) compared with that for conventional rTOF experiments (micros range) significantly magnified the extent of this metastable fragmentation. With the investigated glycopeptides, a complete depletion of the terminal sialic acids of the glycopeptides as well as a variety of other fragment ions was already found in the MS1 spectra from the MALDI-QIT-rTOF instrument. The positive ion low-energy CID spectra (MS2) of the selected glycopeptides obtained using the two different QIT equipped instruments were found to be quite similar. In both approaches, fragmentation of the glycan and peptide structures occurred sequentially, allowing unambiguous sequence determination. In the case of ESI-QIT-MS, fragmentation of the glycan structure occurred at the MS2 stage and fragmentation of the peptide structure was obtained only at the MS3 stage, which indicates the necessity of multistage CID experiments for complete structure elucidation. The MALDI-QIT-rTOF instrument yielded both kinds of fragments at the MS2 stage but without mutual interference.  相似文献   

6.
A 2.94 microm Er:YAG laser was used together with a commercial Fourier transform mass spectrometer to study labile biomolecules. The combination has shown superior performance over conventional 337 nm ultraviolet matrix-assisted laser desorption/ionization (UV-MALDI) Fourier transform mass spectrometry (FTMS), especially for the analysis of peptides with post-translational modifications. With succinic acid as a matrix, the sensitivity of the single-shot analysis was increased by an order of magnitude to the low femtomole level, with significantly less fragmentation observed. Intact molecular ions of a range of O-glycosylated and sulfated peptides were detected. Urea was found to induce even less fragmentation, although at the expense of the total ion yield. Molecular ions of a noncovalent complex (vancomycin + diacetyl-L-Lys-D-Ala-D-Ala) have been observed for the first time in MALDI-FTMS. 2.94 microm infrared (IR) MALDI also produced abundant molecular ions of a range of nonbiological samples, including C60 and C70 fullerenes as well as dimetal coordination complexes.  相似文献   

7.
An investigation of sugar-sugar noncovalent complex fragmentation was conducted using a 2.94 microm Er:YAG laser for infrared (IR) atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI) on an ion trap mass spectrometer (ITMS). This approach allowed the analysis of weak noncovalent complexes between a variety of biologically relevant oligosaccharides. The strength of interaction varied with different sugar structures, potentially due to varying strength of hydrogen bonding networks. In some cases, fragmentation of intramolecular sugar bonds preceded breakdown of the noncovalent complex. This result appeared primarily when complexes contained sugars with at least one sialic acid. Globotrios dimers also showed intramolecular fragmentation in preference to breakdown of the noncovalent dimer. This technique will allow further study of sugar-sugar interactions known to play a role in cellular interactions.  相似文献   

8.
The combination of ion mobility with matrix-assisted laser desorption/ionization allows for the rapid separation and analysis of biomolecules in complex mixtures (such as tissue sections and cellular extracts), as isobaric lipid, peptide, and oligonucleotide molecular ions are pre-separated in the mobility cell before mass analysis. In this study, MALDI-IM MS is used to analyze gangliosides, a class of complex glycosphingolipids that has different degrees of sialylation. Both GD1a and GD1b, structural isomers, were studied to see the effects on gas-phase structure depending upon the localization of the sialic acids. A total ganglioside extract from mouse brain was also analyzed to measure the effectiveness of ion mobility to separate out the different ganglioside species in a complex mixture.  相似文献   

9.
The use of a high-performance orthogonal time-of-flight (o-TOF) mass spectrometer for sequence analysis is described. The mass spectrometer is equipped with a matrix-assisted laser desorption/ionization (MALDI) source that operates at elevated pressure, 0.01-1 Torr. Ion fragmentation is controlled by varying the pressure of the buffer gas, the laser energy, the voltage difference between the MALDI target and the adjacent sampling cone, and between the cone and the quadrupole ion guide. The peptides were analyzed under optimal ionization conditions to obtain their molecular mass, and under conditions that promote ion dissociation via metastable decomposition or collision-induced dissociation (CID). The fragmentation spectra were used to obtain sequence information. Ion dissociation was promoted via three configurations of the ionization parameters. All methods yielded sequencing-grade b- and y-type ions. Two binary mixtures of peptides were used to demonstrate that: (1) external calibration provides a standard deviation (sigma) of 4 ppm with a mode of 9 ppm; and (2) that peptides with molecular masses that differ by a factor of two may be independently fragmented by appropriately choosing the CID energy and the low-mass cut-off. Analyses of tryptic digests employed liquid chromatography (LC), deposition of the eluant on a target, and finally MALDI-TOF mass spectrometry. The mass fingerprint and the (partial) sequence of the tryptic peptides were matched to their precursor protein via database searches.  相似文献   

10.
This short review focuses attention upon the present status of metastable ion studies with emphasis upon the relationship between metastable peak shapes, ion structur and fragmentation mechanisms. Some recommendations are made concerning nomenclature and the reporting of observations on Gaussian-type metastable peaks. Experimental methods for recording relative abundances of metastable peaks are critically appraised. The relationship between metastable ion phenomena and isomerization of gaseous ions is reviewed with particular attention drawn to the effect of rate-determining isomerizations. The shapes of Gaussian-type metastable peaks are discussed in some detail and selected examples from recent studies are used to show that such peaks may, by appropriate experiments, be separated into two Gaussian-type components thus revealing new features of the fragmentation reaction. The magnitude and significance of released kinetic energies, T, are considered and it is stated that few conclusions can be drawn from the evaluation of T alone; the importance of accurate thermochemical data as an aid to understanding and interpreting kinetic energy release data is emphasized. Other topics discussed include composite metastable peaks, metastable peaks produced in chemical ionization and field ionization and the partitioning of internal energy of the fragmenting ion into translational degrees of freedom of the products, for reactions with and without a reverse energy barrier.  相似文献   

11.
By means of collisionally induced dissociative ionization mass spectrometry it was shown that the three isomeric aminopyridine molecular ions display ion chemistry similar to aniline molecular ions; i.e. metastable HNC loss, rather than losing the more stable neutral species HCN, behaviour typical of ionized pyridine. The molecular ions do not isomerize to a common intermediate prior to fragmentation and can readily be distinguished from their collisional activation and charge-stripping mass spectra.  相似文献   

12.
The ion [C3H5]+ generated in a chemical ionization source by a variety of methods, including protonation and charge exchange, exhibits a metastable peak for H2 loss which is two orders of magnitude weaker than that formed in an electron impact source. The stable [C3H5]+ ions generated by electron impact and chemical ionization undergo collision-induced dissociation to a comparable extent, both losing H2 by only one of the two competitive mechanisms observed for metastable ions. In contrast to the behavior of [C3H5]+, the molecular ions of p-substituted nitrobenzene, generated by charge exchange at high source pressure, yield composite metastable peaks for NO loss which are very similar in shape and intensity to those generated by electron impact. The contrasting behavior of the metastable ions extracted from high pressure ion sources in the two systems may be due to differences in the efficiencies of quenching of the ionic states responsible for fragmentation as metastable ions. It is noteworthy that the NO loss reactions require considerably lower activation energies than does the H2 loss reaction.  相似文献   

13.
The fragmentation pattern of some protonated 2,5-diaryl-1,3,4-oxadiazoles is discussed. An unusual decomposition consisting of elimination of the isocyanic acid molecule from the internal oxadiazole ring was found. This fragmentation pathway was deduced on the basis of B/E linked scan mass spectra of metastable ions with liquid secondary ion mass spectrometry as the ionization method and also of low-energy CID mass spectra where electrospray was used as the ionization technique. High resolution measurements were also performed.  相似文献   

14.
A general approach for the detection and structural elucidation of brain ganglioside species GM1, GD1 and GT1 by nano-electrospray ionization quadrupole time-of-flight (nanoESI-QTOF) mass spectrometry (MS), using combined data from MS and MS/MS analysis of isolated native ganglioside fractions in negative ion mode and their permethylated counterparts in the positive ion mode is presented. This approach was designed to detect and sequence gangliosides present in preparatively isolated ganglioside fractions from pathological brain samples available in only very limited amounts. In these fractions mixtures of homologue and isobaric structures are present, depending on the ceramide composition and the position of the sialic acid attachment site. The interpretation of data for the entire sequence, derived from A, B, C and Y ions by nanoESI-QTOFMS/MS in the negative ion mode of native fractions, can be compromised by ions arising from double and triple internal cleavages. To distinguish between isobaric carbohydrate structures in gangliosides, such as monosialogangliosides GM1a and GM1b, disialogangliosides GD1a, GD1b and GD1c or trisialogangliosides GT1b, GT1c and GT1d, the samples were analysed after permethylation in the positive ion nanoESI-QTOFMS/MS mode, providing set of data, which allows a clear distinction for assignment of outer and inner fragment ions according to their m/z values. The fragmentation patterns from native gangliosides obtained by low-energy collision induced dissociation (CID) by nanoESI-QTOF show common behaviour and follow inherent rules. The combined set of data from the negative and positive ion mode low-energy CID can serve for the detection of structural isomers in mixtures, and to trace new, not previously detected, components.  相似文献   

15.
Fragmentation processes that occur very early during matrix-assisted laser desorption ionization (MALDI) of peptides are examined by utilization of delayed pulsed ion extraction with a linear time-of-flight mass spectrometer. The oxidized B chain of bovine insulin (MW=3495. 95 u), which produces a wide range of fragment ions, is utilized as a probe to examine the effects of several experimental parameters on this process. Experimental evidence suggests that this MALDI process is not prompt fragmentation and involves metastable ion decay that is quite different from that which is observed with postsource decay experiments. This conclusion is based upon the significant differences observed in the fragmentation products produced by the two techniques. This metastable ion decay process also appears to be over within the minimum pulse delay period (320 ns) that is possible with the current pulsed ion extraction hardware. These two observations suggest that either different activation processes are involved in the two techniques or that the much different time frame of the methods influences the observed ion decay pathways. This fast MALDI metastable ion fragmentation also is shown to be influenced by both the MALDI matrix and the laser fluence.  相似文献   

16.
A previously unreported series of N-(substituted benzalamino)phthalimides was investigated by using the combined techniques of high resolution electron ionization mass spectrometry, metastable decomposition, and collisional activation mass spectrometry. The predominate fragmentation pathway is a McLafferty-type rearrangement. There also occurs, to a lesser extent, a transfer of hydrogen that originates from a substituent remote from the phthalimide moiety and terminates on the phthalimide, The process is interpreted as proceeding via an ion-neutral complex. The effects of substituents on both of the aforementioned fragmentation pathways provide a striking example that gives quantitative evidence for Stevenson’s rule. The substituent effects are responsible for a trend in ion abundance that shows a sharp reversal at approximately the ionization energy of the iminium isomer of the phthalimide molecular ion.  相似文献   

17.
The mass spectral fragmentation patterns of pyrrolo[3, 2, 1-kl]phenothiazine ( 1 ) and its 1, 10-dideuterioderi-vative [2] are reported. The site of deuterium substitution in 2 was established by examination of its 13C nuclear magnetic resonance spectrum. The heteroaromatic stability of 1 to electron impact is exemplified by the occurrence of the molecular ion as the base peak and the formation of a reasonably intense M2+ ion. An intense M-1 ion is also observed. The more abundant fragment ions appear to result from sulfur ionization. Fragment ions arising from ionization of the nitrogen constitute only a small fraction of the total ion current. Proposed fragmentation pathways of 1 are supported by the detection of appropriate metastable ions, exact mass measurements, and electron impact spectrum of 2 .  相似文献   

18.
Electron ionization mass spectra of some 3,4-disubstituted 1,2,4-oxadiazole-5(4H)-thiones, thiadiazol-5(4H)-ones and thiadiazole-5(4H)-thiones are reported and fragmentation pathways of their molecular ions are studied in view of metastable ion experiments and accurate mass measurements. The main fragmentation route of the compounds under investigation is retro 1,3-dipolar cycloaddition.  相似文献   

19.
Polyurethanes are widely used in the manufacture of commercial products such as foams and paints. During combustion, these polymers can generate isocyanates, which induce adverse health effects. Polymer pyrolysis (Py) hyphenated with mass spectrometry (MS) allows the investigation of polymer thermal degradation over time/temperature. A diphenylmethanediisocyanate (MDI) polyurethane foam was analyzed with electron ionization (EI) and metastable atom bombardment (MAB) ionization at a pyrolysis temperature of 400 °C. The recently introduced MAB ionization source uses discrete energy stored in metastable atoms of gases to ionize the analytes. This characteristic allows modulation of the ionization energy by simply changing the ionization gas. The extensive fragmentation of molecular ions observed using EI 70 eV is not totally eliminated with EI 10 eV. However, only molecular ions are observed with MAB using N2 as the ionization gas. Temperature gradients were used to separate the products generated during the thermal degradation of a 1,6-hexamethylenediisocyanate (HDI) polyurethane paint. The analysis of mass spectra was facilitated owing to a selective desorption of pyrolysis products. Furthermore, changing the MAB ionization gas allows elucidation of the structure of the pyrolysis products by controlling the extent of their fragmentation. During these experiments, isocyanic acid, methyleneisocyanate, ethyleneisocyanate, propylisocyanate and butylisocyanate were detected.  相似文献   

20.
Modern glycan analysis is primarily based on mass spectrometry, where instruments based on electrospray or matrix-assisted laser desorption ionization are currently the most frequently used. In the present study, electrospray ionization (ESI) coupled with a high-resolution Fourier transform mass spectrometer (LTQ Orbitrap) and matrix-assisted laser desorption/ionization (MALDI) coupled with a time-of-flight (TOF/TOF) detector were used to analyze two N-glycan standards with intact free reducing ends (disialo biantennary and asialo triantennary) and representative PA-labeled human serum N-glycan structures isolated by hydrophilic interaction anion-exchange chromatography (HIAX), confirmed by 1H NMR analysis and consequently compared with the ProteinScape Glycome database. Different combinations of ion sources with fragmentation devices results in various fragmentation patterns and adducts. Also, the effect of sample derivatization on the acquired signals is discussed. Compared to the MALDI technique, free glycans did not lose labile sialic acids easily in the ESI source. On the other hand, fluorescent PA-labeling leads to improved core fragmentation and signal intensities; linkage-specific ethyl esterification leads to reduced adduct and fragment formation and enhanced stability of sialic acids in the MALDI ion source. Thereby, both methods have their advantages and disadvantages in terms of detection, fragmentation and robustness.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号