首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A one meter stainless steel capillary column coated with a 20μm film of polydimethylsiloxane was used to replace the Teflon gas sampling loop of a HRGC – flameless SCD system. This column trap was equilibrated with the gaseous sample and then purged with carrier gas while being sequentially, resistively heated in ten 10 cm sections. The sequential heating of the 10cm sections was timed such that the velocity of the moving heated zone was approximately the same as the velocity of the carrier gas. The thick stationary phase film served to retard the front end of the injection band while the ballistic heating accelerated the back end. The net result was focusing of the injection, which gave rise to a narrower injection profile than that obtained with the original Teflon loop.  相似文献   

2.
A method using a sulfur chemiluminescence detector (SCD) has been developed for the qualitative and quantitative determination of sulfur components in stabilized gasoline-range process streams, including blended gasolines containing between 1 and > 4000 ppm total sulfur. The detection limit per sulfur component was approximately 50 ppb. On-column injection was employed for optimum precision and accuracy. A new probe material was found which did not soften under FID operating conditions. A new method, using a hydrogen sulfide permeation tube, was developed for rapid alignment of the probe in the FID.  相似文献   

3.
This paper reports an analytical method for separating, identifying, and quantifying sulfur-containing compounds in crude oil fraction (IBP-360 degrees C) samples based on comprehensive two-dimensional gas chromatography coupled with a sulfur chemiluminescence detector. Various sulfur-containing compounds and their groups were analyzed with one direct injection. 3620 peaks were detected including 1722 thiols/thioethers/ disulfides/1-ring thiophenes, 953 benzothiophenes, 704 dibenzothiophenes, and 241 benzonaphthothiophenes. The target sulfur compounds and their groups were identified based on the group separation feature and structured retention of comprehensive two-dimensional gas chromatography as well as standard substances. The quantitative analysis of major sulfur-containing compounds and total sulfur was based on the linear response of the sulfur chemiluminescence detector using the internal standard method. The sulfur contents of target sulfur compounds and their groups in 4 crude oil fractions were also determined. The recoveries for standard sulfur-containing compounds were in the range of 90-102%. The quantitative result of total sulfur in the Oman crude oil fraction sample was compared with those from ASTM D 4294 standard method (total S by X-ray fluorescence spectrometry), the relative deviation (RD%) was 4.2% and the precision of the method satisfactory.  相似文献   

4.
Supercritical fluid chromatography using flameless sulfur chemiluminescence detection has been investigated for the analysis of sulfur compounds in petroleum products. The chromatography and detection system was easy to implement and exhibited good precision, linearity, selectivity, and sensitivity. A minimum detectable limit of 0.3 pg sulfur/s was obtained, and response to sulfur in different sulfur species was nearly equimolar.  相似文献   

5.
A fast and reliable analytical technique for the determination of total sulfur levels in complex hydrocarbon matrices is introduced. The method employed flow injection technique using a gas chromatograph as a sample introduction device and a gas phase dual‐plasma sulfur chemiluminescence detector for sulfur quantification. Using the technique described, total sulfur measurement in challenging hydrocarbon matrices can be achieved in less than 10 s with sample‐to‐sample time <2 min. The high degree of selectivity and sensitivity toward sulfur compounds of the detector offers the ability to measure low sulfur levels with a detection limit in the range of 20 ppb w/w S. The equimolar response characteristic of the detector allows the quantitation of unknown sulfur compounds and simplifies the calibration process. Response is linear over a concentration range of five orders of magnitude, with a high degree of repeatability. The detector's lack of response to hydrocarbons enables direct analysis without the need for time‐consuming sample preparation and chromatographic separation processes. This flow injection‐based sulfur chemiluminescence detection technique is ideal for fast analysis or trace sulfur analysis.  相似文献   

6.
7.
8.
The analysis of sulfur-containing compounds using fused silica capillary columns and the Sulfur Chemiluminescence Detector has been investigated. This combination of an inert chromatographic system and a high sensitivity, selective detector provides significant advantages for the analysis of low levels of sulfur compounds in complex matrices over existing techniques. Capillary columns coated with thick films (1–4 μm) of methyl silicone stationary phase permit separation of most sulfur containing compounds and, when used with sub-ambient column temperatures, these columns can be used for the separation of sulfur gases. The effects of stationary film thickness, column length, and internal diameter for the measurement of sulfur compounds in hydrocarbon matrices has been determined.  相似文献   

9.
The sensitive detection of sulfur-containing analytes is of interest in many industrial applications; selective detection is also desirable since these compounds are usually present at trace levels in difficult matrixes. The purpose of this article is to review the use of the Sievers® ozone-based sulfur chemiluminescence detector, and its coupling with gas chromatography, supercritical fluid chromatography, and high performance liquid chromatography. Detection limits, linearity, response factors, and selectivity are discussed for each of these techniques. Critical operational parameters for the SCD are also described. The use of other sulfur selective detectors for SFC and HPLC is also briefly summarized.  相似文献   

10.
化学发光与色谱联用具有选择性好、灵敏度高等优点,应用广泛.本文主要介绍近三年来化学发光包括鲁米诺、过氧草酸酯、Ru(bipy)33 、无机等体系作为液相色谱柱后检测及含氮、含硫化合物气相化学发光等体系作为气相色谱柱后检测的现状.  相似文献   

11.
毛细管电泳与化学发光检测联用方法的研究进展   总被引:1,自引:0,他引:1  
易方  黄香宜  任吉存 《色谱》2017,35(1):110-120
毛细管电泳由于其超高的分离效率广泛应用于生物医药、环境监测、食品科学以及公共安全等领域。然而,由于毛细管电泳具有进样量较少、检测光程较短等缺点,需要与高灵敏度检测器联用实现低浓度样品的分析。化学发光检测由于其背景信号低而具有超高的灵敏度。毛细管电泳-化学发光检测联用方法将毛细管电泳的高效分离特性与化学发光检测的高灵敏性相结合,成为一种非常重要的分析方法,广泛用于化学分析、药物筛选以及环境监测等领域。该文对近年来毛细管电泳-化学发光检测联用方法的基本原理进行概述,并对其发展趋势和应用前景进行了展望。  相似文献   

12.
任代卫  梁韬  黎刚  张海东  王璞  肖珂  李英明  张庆华 《色谱》2014,32(9):971-974
利用高分辨气相色谱/高分辨质谱联用仪(HRGC/HRMS)和高分辨气相色谱/低分辨质谱仪(HRGC/LRMS)对实际生物样品中二恶英(polychlorinated dibenzo-p-dioxins and dibenzofurans,PCDD/Fs)的分析过程中13C标记的2,3,7,8-四氯代二苯并呋喃(13C12-2,3,7,8-TCDF)监测碎片离子通道的两个常见干扰峰进行了分析鉴定。通过实际样品分析结果首先推测这两个干扰峰可能为有机氯农药类化合物滴滴涕(DDT)降解产物滴滴伊(DDE)的两个异构体,其次采用DDE的标准溶液(包括o,p’-DDE和p,p’-DDE)进行分析确认。通过HRGC/HRMS的色谱峰分离效果分析、色谱保留时间匹配以及与DDE碎片离子的理论丰度比进行比较,最终确认实际样品分析中的两个干扰峰依次为o,p’-DDE和p,p’-DDE。本文可为生物样品中二恶英的准确识别提供重要参考。  相似文献   

13.
A slightly modified, commercially available high resolution capillary gas chromatograph and a PC-based data processing system running proprietary software (“PONA”) have been employed in the development of a system for petroleum type analysis which would be equivalent or superior to the FIA (fluorescent indicator adsorption) method in terms of ease of use and the speed, variety, and accuracy of the analytical data produced. The system is capable of performing identification and quantitation of most of the individual components in a complex gasoline sample consisting of more than 230 components and can report weight percentage and/or volume percentage for each component as well as types by carbon number (e.g., isoparaffins, normal paraffins, olefins, naphthenes, aromatic compounds) within a ca. 70 minute analysis cycle. Precolumn sulfonation to trap olefins and aromatic compounds has been used as an complementary technique to the basic mass spectrometric identification of components of interest. The estimation of correction factors for weight percentage (or volume percentage) calculation are also discussed. Comparisons are made between this system and others, and the results indicate that the proposed method supersedes the conventional method employing FIA.  相似文献   

14.
杨永坛  吴明清  王征 《色谱》2010,28(4):336-340
建立了催化汽油馏分中各种含氮化合物类型分布的气相色谱-氮化学发光检测分析方法,考察了各种色谱条件对含氮化合物分离的影响。采用化学预处理的方法浓缩了催化汽油中的含氮化合物,并结合气相色谱-质谱检测以及部分含氮化合物标准样品,对某催化汽油中的20多个含氮化合物进行了定性(或归类)。催化汽油中几种主要含氮化合物(苯胺、2-甲基苯胺、二甲基苯胺)含量测定值的相对标准偏差(RSD)均不大于2.5%。当信噪比(S/N)为3时,苯胺氮的检出限为1.0 mg/L。该方法可用于不同来源和不同加工工艺的汽油馏分中各种含氮化合物类型分布的研究。  相似文献   

15.
A new detection system consisted of a flame ionization detector (FID) and a sulfur chemiluminescence detector (SCD) was developed for sensitive and interference free determination of total sulfur in natural gas by non-separation gas chromatography. In this system, sulfur containing compounds and hydrocarbons were firstly burned in the FID using oxygen rich flame and converted to SO2, CO2 and H2O, respectively. The products from FID were transported into the SCD with hydrogen rich atmosphere wherein only SO2 could be reduced to SO and reacted with O3 to produce characteristic chemiluminescence. Therefore, the chemiluminescence of CO found in conventional SCD were eliminated because CO2 could not be reduced to CO under these conditions. The experimental parameters were systematically investigated. Limit of detection obtained by the proposed system is better than 0.5 μmol/mol for total sulfur and superior to those previously reported. The proposed method not only retains the advantages of the conventional SCD but also provides several unique advantages including no hydrocarbon interference, better stability, and easier calculation. The utility of this technique was demonstrated by the determination of total sulfur in real samples and two certified reference materials (GBW 06332 and GBW (E) 061320).  相似文献   

16.
Sandmann  B. W.  Grayeski  M. L. 《Chromatographia》1994,38(3-4):163-167
Summary A detection scheme based upon peroxyoxalate chemiluminescence, which utilizes two post-column pumps and two stages of depressurization is investigated. The chemiluminescent detection limit for perylene is 23 times lower than determined by fluorescence, and is in the attomole range. This detection technique is investigated for packed column supercritical fluid chromatography (SFC). Due to the interface design used and the chemical band narrowing effects of chemiluminescence, an apparent increase in efficiency is observed. The interface design affords a wide range of pressures to be used for a separation. During pressure programming the column effluent changes flow rate. Because of a back-pressure regulator, the reaction and detection take place at nearly constant pressure. Therefore pressure gradient work is possible without concern for post-column reagent solubility (which is a concern for high-performance liquid chromatography). The effects of the expanded CO2 from the SFC on the chemiluminescence signal and background are studied. The post-column detection is optimized for pH, photomultiplier voltage, concentrations and flow rates of the peroxide and oxalate ester.  相似文献   

17.
An overview is presented of the analytical approaches developed by our research group over the last ten years for analysis of alternative fuel, both biomass and fossil. The alternative fuels are analyzed successively by PLC-8 (preparative liquid chromatography–group-type) fractionation and high resolution gas chromatography. Some of the possibilities for fractionation and characterization of alternative fuels are herein exemplified with sugar cane bagasse pyrolysis products.  相似文献   

18.
Gas chromatrography (GC) with sulfur chemiluminescence detection (SCD) is an outstanding combination for selectively determining trace concentrations of sulfur compounds in hydrocarbon samples. GC peaks can be identified by retention times when reproducible, automated injection techniques are used. However, as described in this work, analysts should be on the look out for retention shifting due to solvent effects from sample components. Three examples of retention shifting are presented: (1) thiophene by benzene; (2) methylthiophenes by toluene; and (3) dibenzothiophene by gas oil. Depending on samples and analysis conditions, retention shifts from a few hundredths to 1.5 min have been observed. Such retention shifts are likely to cause errors in peak identifications. Therefore, when using SCD, simultaneous FID monitoring is recommended as an aid in evaluating chromatograms for possible retention shifting due to solvent effects.  相似文献   

19.
Sulfur mustard (HD), bis(2-chloroethyl)sulfide, is one of a class of mustard agents which are chemical warfare agents. The main chemical warfare hydrolysis degradation products of sulfur mustards are: thiodiglycol, bis(2-hydroxyethylthio)methane, 1,2-bis(2-hydroxyethylthio)ethane, 1,3-bis(2-hydroxyethylthio)propane, and 1,4-bis(2-hydroxyethylthio)butane. The aim of this study is to identify these five hydrolysis degradation products utilizing reversed-phase high-performance liquid chromatography coupled with inductively coupled plasma mass spectrometry (ICP-MS) for element-specific sulfur detection using a collision/reaction cell and electrospray ionization mass spectrometry to confirm the identification. To date, this is the first study utilizing ICP-MS with 32S element-specific detection for the analysis of vesicant chemical warfare agent degradation products.  相似文献   

20.
Sulfur has been detected in a spectral window (around 868 nm) previously unexplored by laser-induced breakdown spectrometry (LIBS), using an ablation laser with an ultraviolet wavelength, a gated detector, and inert ambient gas at a low, controlled pressure. This spectral window enables new-generation gated iCCD cameras to be used, which have adequate quantum efficiencies up to 900 nm. Application of our technique can substantially improve signal strength and thus extends the ability of LIBS to detect many nonmetallic elements.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号