首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Monitoring anabolic steroids in meat-producing animals is a challenging task. It implies very specific and sensitive analytical methods able to detect and identify sub-μg kg?1 residue levels in complex biological matrices such as meat, urine, or hair. Gas and liquid chromatography coupled to mass spectrometry are the most efficient means of achieving these objectives. In this paper we review how developments in mass spectrometry have been rapidly applied to this problem, how efficient analysis of anabolic steroids in urine, edible tissue, and hair has been achieved, and, later, how measurement of conjugate steroids and determination of the origin of natural steroid hormones has been achieved. The performance characteristics of different mass spectrometers (quadrupole, ion-trap, electromagnetic, isotope-ratio, tandem, and hybrid instruments), the efficiency of different acquisition techniques (LR-SIM, HR-SIM, MRM), and, finally, sample introduction (gas chromatography and liquid chromatography, with discussion of alternative interfaces) are discussed, with numerous applications.  相似文献   

2.
The applicability of in-vial two-phase liquid-phase microextraction (LPME) in porous hollow polypropylene fiber was studied for the sample preparation of unconjugated anabolic steroids in urine. Four different anabolic steroids - metabolites of fluoxymesterone, 4-chlorodehydromethyltestosterone, stanozolol and danazol - were used as test compounds and methyltestosterone as an internal standard. A standard two-phase LPME method for use with liquid chromatography/mass spectrometry (LC/MS) was set up and the influence of different parameters, including the nature of organic solvent, extraction time, salting-out and temperature, on the LPME process was investigated. Taking advantage of the preliminary studies, a novel two-phase LPME method utilizing simultaneous in-fiber silylation was developed and validated for gas chromatographic/mass spectrometric (GC/MS) analysis of a danazol metabolite in urine. In all, LPME allowed a very straightforward, simple and selective way to prepare urine samples for steroid analysis, being most suitable for hydrophobic steroids. The LPME method with in-fiber derivatization for GC/MS analysis exhibited high sensitivity, repeatability and linearity and enabled simultaneous filtration, extraction, enrichment and derivatization of the analyte from urine matrix without any other steps in sample pretreatment.  相似文献   

3.
Within the European Union the use of anabolic steroids for promoting growth and improving meat-to-fat ratio in food-producing animals has been banned since 1988. For the unequivocal identification of hormone residues in a complex matrix such as meat we have developed a rapid, specific and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method, in combination with a simple extraction procedure based on the matrix solid-phase dispersion (MSPD). The performances of a triple quadrupole (QqQ) and a quadrupole/time-of-flight (QqTOF) were compared: the QqQ mass spectrometer was found to be more sensitive for almost all studied analytes, but the selectivity was superior using the QqTOF system; the full-scan spectra (acquired without losing sensitivity), mass accuracy and resolution of the hybrid instrument enabled a more probatory analyte identification than that obtained selecting two multiple-reaction monitoring (MRM) transitions with a QqQ. Average recoveries ranged from 80 to 100%, and the detection capabilities (CCbetas) were less than 1.06 ppb with the QqQ instrument and less than 5.20 ppb with the QqTOF instrument for the bovine meat, which proved to be the most complex matrix.  相似文献   

4.
A new combined doping control screening method for the analysis of anabolic steroids in human urine using liquid chromatography/electrospray ionization orthogonal acceleration time-of-flight mass spectrometry (LCoaTOFMS) and gas chromatography/electron ionization orthogonal acceleration time-of-flight mass spectrometry (GCoaTOFMS) has been developed in order to acquire accurate full scan MS data to be used to detect designer steroids. The developed method allowed the detection of representative prohibited substances, in addition to steroids, at concentrations of 10 ng/mL for anabolic agents and metabolites, 30 ng/mL for corticosteroids, 500 ng/mL for stimulants and beta-blockers, 250 ng/mL for diuretics, and 200 ng/mL for narcotics. Sample preparation was based on liquid-liquid extraction of hydrolyzed human urine, and the final extract was analyzed as trimethylsilylated derivatives in GCoaTOFMS and underivatized in LCoaTOFMS in positive ion mode. The sensitivity, mass accuracy, advantages and limitations of the developed method are presented.  相似文献   

5.
Mass spectrometers equipped with atmospheric pressure ion sources (API-MS) have been designed to be interfaced with liquid chromatographs (LC) and have rarely been connected to gas chromatographs (GC). Recently, we introduced a heated nebulizer microchip and showed its potential to interface liquid microseparation techniques and GC with API-MS. This study demonstrates the feasibility of GC-microchip atmospheric pressure photoionization-tandem mass spectrometry (GC-μAPPI-MS/MS) in the analysis of underivatized anabolic steroids in urine. The APPI microchip provides high ionization efficiency and produces abundant protonated molecules or molecular ions with minimal fragmentation. The feasibility of GC-μAPPI-MS/MS in the analysis of six selected anabolic steroids in urine samples was studied with respect to intra-batch repeatability, linearity, linear range, and limit of detection (LOD). The method showed good sensitivity (LODs 0.2-1 ng/mL), repeatability (relative standard deviation<10%), and linearity (regression coefficient≥0.9995) and, therefore, high potential for the analysis of anabolic steroids. Quantitative performance of the method was tested with two authentic urine samples, and the results were in good agreement with those obtained with conventional GC-electron ionization-MS after derivatization.  相似文献   

6.
The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods were optimized regarding eluent composition, ion source parameters and fragmentation. The methods were compared with respect to specificity and detection limit. Although all methods proved suitable, LC/ESI-MS/MS with a methanol-water gradient including 5 mM ammonium acetate and 0.01% acetic acid was found best for the purpose. Multiple reaction monitoring allowed the determination of steroids in urine at low nanogram per milliliter levels. LC/MS/MS exhibited high sensitivity and specificity for the detection of free steroids and may be a suitable technique for screening for the abuse of anabolic steroids in sports.  相似文献   

7.
8.
The detection of steroid residues in hair is a powerful strategy to demonstrate long-term administration of these growth promoters in meat production animals. A fast and reliable method was developed for monitoring anabolic steroids and their esters in hair. A 100 mg hair sample was converted into powder and extracted at 50 °C with methanol (sebum fraction). The remaining hair was digested with 1 M NaOH for further extraction of bound steroids. The two fractions were separately purified onto an aminopropyle solid-phase extraction column and onto a silica SPE cartridge. Steroids were detected either by gas chromatography-tandem mass spectrometry after silylation using N-methyl-N-(trimethylsilyl)-trifluoroacetamide/trimethyliodosilane/dithiothreitol or liquid chromatography-tandem mass spectrometry. This method was applied to hair samples collected over a three months period after treatment of three cows respectively with 17α-methyltestosterone, medroxyprogesterone acetate and 17β-estradiol-3-benzoate. The fixation kinetic into hair of the three steroids have been deeply examined and discussed; relation in-between concentration and distance from the injection site, influence of hair colour and sample treatment consequences have been discussed.  相似文献   

9.
For almost two decades we have known that enzymatic hydrolysis of "normal" urine samples from the entire male horse using Escherichia coli (E. coli) followed by solvolysis (ethyl acetate:methanol:sulphuric acid) results in the detection of significant amounts of estr-4-ene-3,17-dione (19-norandrost-4-ene-3,17-dione) along with estr-4-en-17beta-ol-3-one (19-nortestosterone, nandrolone) in extracts of the hydrolysed urine and that both steroids are isolated from the solvolysis fraction. This solvolysis process is targeted at the steroid sulphates. Also we have shown that 19-norandrost-4-ene-3,17-dione and 19-nortestosterone are isolated from testicular tissue extracts. Subsequently, evidence was obtained that 19-nortestosterone detected in extracts of "normal" urine from male horses may not be derived from the 17beta-sulphate conjugate. However, following administration of 19-nortestosterone based proprietary anabolic steroids to all horses (males, females and castrates), the urinary 19-nortestosterone arising from the administration is excreted primarily as the 17beta-sulphate conjugate. Thus, if the 19-nortestosterone-17beta-sulphate conjugate arises only following administration this has interesting implications for drug surveillance programmes to control administration of 19-nortestosterone based anabolic preparations to male horses. These results have led us to consider that the precursors to 19-nortestosterone and 19-norandrost-4-ene-3,17-dione, present in the urine prior to the hydrolysis steps, have the same basic structure except for the functionality at the 17-position. We have used preparative high pressure liquid chromatography (LC) and LC fractionation to separate these precursors from the high amounts of oestrogenic sulphates present in "normal" urine from the entire male horse. Purified fractions have then been studied by liquid chromatography-mass spectrometry (LC-MS) and gas chromatography-mass spectrometry (GC-MS) to identify the precursors.  相似文献   

10.
The detection of the abuse of anabolic steroids in equine sport is complicated by the endogenous nature of some of the abused steroids, such as testosterone and nandrolone. These steroids are commonly administered as intramuscular injections of esterified forms of the steroid, which prolongs their effects and improves bioavailability over oral dosing. The successful detection of an intact anabolic steroid ester therefore provides unequivocal proof of an illegal administration, as esterified forms are not found endogenously. Detection of intact anabolic steroid esters is possible in plasma samples but not, to date, in the traditional doping control matrix of urine. The analysis of equine mane hair for the detection of anabolic steroid esters has the potential to greatly extend the time period over which detection of abuse can be monitored.  相似文献   

11.
The European Union banned the use of anabolic steroids for cattle fattening in 1988. Analytical techniques able to detect trace amounts of the parent drugs and their metabolites are mandatory for the control of abuse. Stanozolol (Stan) is an anabolic steroid that is often found in injection sites and cocktails. However, it has never been detected in tissues (kidney fat, meat) or excreta (urine, faeces) taken during regulatory inspection. The difference between the structure of Stan and the other steroids (a pyrazole ring fused to the androstane ring system) is probably the cause of this phenomenon. In the multi-laboratory study described here, veal calves were treated with intramuscular doses of Stan. In the excreta of these calves the presence, absence and/or concentration of Stan and of its major metabolites 16 beta-hydroxystanozolol and 3'-hydroxystanozolol were determined. For the determination of these analytes the different laboratories used different extraction and clean-up procedures and also evaluated different analytical techniques such as GC-MS (negative chemical ionization) and LC-MS-MS. The aim of this investigation was to explore which analyte should be validated for veterinary inspection purposes.  相似文献   

12.
Norchlorotestosterone acetate (NClTA) is an anabolic steroid which resembles chlorotestosterone acetate. It cannot yet be detected by routine methods used for anabolic steroids, because there is no knowledge of its metabolic pathway. The invertebrate Neomysis integer has been used as an alternative model to study the metabolism of NClTA. The experimental results indicated the presence of 4-norchloroandrost-4-ene-17-ol-3-one (NClT) and 4-norchloroandrost-4-ene-3,17-dione (NorClAD) as possible metabolites of NClTA. Subsequently NClTA and the synthesised metabolites NClT and NorClAD were incorporated into the routine multi-residue method for detection of anabolic steroids in kidney fat, urine, and faeces.  相似文献   

13.
The control on use of anabolic agents in meat producing animals is generally based on urine, faeces or hair analysis. This exercise, which is usually performed in slaughterhouses or on farms, is not relevant to imported carcasses or retail meat. A single sensitive method for a wide range of anabolic steroids was developed. After extraction of the lyophilised meat, enzymatic hydrolysis was used for deconjugation. Solid-phase extraction on a polymeric stationary phase was performed prior to hydrolysis of ester residues under alkaline conditions. Liquid-liquid partitioning was used to separate the analytes into two main categories: phenol containing molecules, such as phenolic steroids, resorcylic acid lactones and stilbenes, and delta4-3-one containing molecules, such as most androgens and progestagens. Solid-phase extraction on silica columns was performed before applying a specific derivatisation for each compound sub-group. The combination of high-resolution chromatography with a quadrupole mass spectrometer permitted detection of 23 steroids in the 5-100 ng/kg range. Ion chromatograms for residue positive samples are shown and discussed.  相似文献   

14.
Rapid detection of trace level anabolic steroids in urine is highly desirable to monitor the consumption of performance enhancing anabolic steroids by athletes. The present article describes a novel strategy for identifying the trace anabolic steroids in urine using Leidenfrost phenomenon assisted thermal desorption (LPTD) coupled to dielectric barrier discharge (DBD) ionization mass spectrometry. Using this method the steroid molecules are enriched within a liquid droplet during the thermal desorption process and desorbed all-together at the last moment of droplet evaporation in a short time domain. The desorbed molecules were ionized using a dielectric barrier discharge ion-source in front of the mass spectrometer inlet at open atmosphere. This process facilitates the sensitivity enhancement with several orders of magnitude compared to the thermal desorption at a lower temperature. The limits of detection (LODs) of various steroid molecules were found to be in the range of 0.05–0.1 ng mL−1 for standard solutions and around two orders of magnitude higher for synthetic urine samples. The detection limits of urinary anabolic steroids could be lowered by using a simple and rapid dichloromethane extraction technique. The analytical figures of merit of this technique were evaluated at open atmosphere using suitable internal standards. The technique is simple and rapid for high sensitivity and high throughput screening of anabolic steroids in urine.  相似文献   

15.
Fuh MR  Huang SY  Lin TY 《Talanta》2004,64(2):408-414
The use of natural and synthetic anabolic steroids in animal fattening has been prohibited in Taiwan and many countries because of their potential toxic effect on public health. This paper describes a newly developed gas chromatography-ion trap-mass spectrometry (GC-IT-MS) method for the quantitative determination of various residual anabolic steroids in meat. Anabolic steroid was derivatized with N-methyl-N-trimethylsilytrifluoroacetamide prior to GC-IT-MS analysis. MS2 was employed for quantitative measurement. In addition, 2d-estradiol was used as an internal standard. Quantitative determination was based on the ratio of peak area of steroid derivative to peak area of internal standard derivative. Good linearity of each compound, 0.03-1.0 μg/ml, was determined. Solvent extraction was used to extract residual anabolic compounds in meat samples and a solid phase extraction (SPE) procedure was utilized for sample cleanup and pre-concentration. The limits of detection of anabolic compounds approximately ranged from 0.1 to 0.4 μg/kg. The detection limit was comparable with or better than reported methods and was below the minimum required performance limits (MRPLs) established by the European Community (EC). The application of this newly developed method was demonstrated by analyzing various beef, pork, chicken and several animal internal organ samples from local markets.  相似文献   

16.
The use of performance enhancing drugs in sports is prohibited. For the detection of misuse of such substances gas chromatography or liquid chromatography coupled to mass spectrometry are the most frequently used detection techniques. In this work the development and validation of a fast gas chromatography tandem mass spectrometric method for the detection of a wide range of doping agents is described. The method can determine 13 endogenous steroids (the steroid profile), 19-norandrosterone, salbutamol and 11-nor-Δ9-tetrahydrocannabinol.9carboxylic acid in the applicable ranges and to detect qualitatively over 140 substances in accordance with the minimum required performance levels of the World Anti-Doping Agency in 1ml of urine. The classes of substances included in the method are anabolic steroids, β2-agonists, stimulants, narcotics, hormone antagonists and modulators and beta-blockers. Moreover, using a short capillary column and hydrogen as a carrier gas the run time of the method is less than 8min.  相似文献   

17.
Doping control of anabolic substances is normally carried out with urine samples taken from athletes and horses. Investigation of alternative specimens, e.g. hair samples, is restricted to special cases, but can also be worthwhile, in addition to urine analysis. Moreover, hair material is preferred in cases of limited availability or complicated collection of urine samples, e.g. from horses. In this work, possible ways of interpretation of analytical results in hair samples are discussed and illustrated by practical experiences. The results demonstrate the applicability of hair analysis to detect anabolic steroids and also to obtain further information about previous abuse. Moreover, the process of incorporation of steroids into hairs is described and the consequences on interpretation are discussed, e.g. on the retrospective estimation of the application date. The chosen examples deal with the detection of the anabolic agent testosterone propionate. Hair samples of an application study, as well as a control sample taken from a racing horse, were referred to. Hair material was investigated by a screening procedure including testosterone, nandrolone and several esters (testosterone propionate, phenylpropionate, decanoate, undecanoate, cypionate; nandrolone decanoate, dodecanoate and phenylpropionate; limits of detection (LODs) between 0.1 and 5.0 pg/mg). Confirmation of testosterone propionate (LOD 0.1 pg/mg) was carried out by an optimised sample preparation. Trimethylsilyl (TMS) and tert-butyl dimethylsilyl derivatives were detected by gas chromatography-high-resolution mass spectrometry (GC-HRMS) and gas chromatography-tandem mass spectrometry (GC-MS/MS).  相似文献   

18.
The application of a comprehensive gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS)-based method for stable carbon isotopes of endogenous urinary steroids is presented. The key element in sample preparation is the consecutive cleanup with high-performance liquid chromatography (HPLC) of underivatized and acetylated steroids, which allows the isolation of ten analytes (11beta-hydroxyandrosterone, 5alpha-androst-16-en-3beta-ol, pregnanediol, androsterone, etiocholanolone, testosterone, epitestosterone, 5alpha-androstane-3alpha,17beta-diol, 5beta-androstane-3alpha,17beta-diol and dehydroepiandrosterone) from a single urine specimen. These steroids are of particular importance to doping controls as they enable the sensitive and retrospective detection of steroid abuse by athletes.Depending on the biological background, the determination limit for all steroids ranges from 5 to 10 ng/mL for a 10 mL specimen. The method is validated by means of linear mixing models for each steroid, which covers repeatability and reproducibility. Specificity was further demonstrated by gas chromatography/mass spectrometry (GC/MS) for each analyte, and no influence of the sample preparation or the quantity of analyte on carbon isotope ratios was observed. In order to determine naturally occurring (13)C/(12)C ratios of all implemented steroids, a reference population of n = 61 subjects was measured to enable the calculation of reference limits for all relevant steroidal Delta values.  相似文献   

19.
A sensitive and rapid method based on liquid chromatography-triple-quadrupole tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI) has been developed and validated for the screening and confirmation of 44 exogenous anabolic steroids (29 parent steroids and 15 metabolites) in human urine. The method involves an enzymatic hydrolysis, liquid-liquid extraction, and detection by LC-MS/MS. A triple-quadrupole mass spectrometer was operated in positive ESI mode with selected reaction monitoring (SRM) mode for the screening and product ion scan mode for the confirmation. The protonated molecular ions were used as precursor ions for the SRM analysis and product ion scan. The intraday and interday precisions of the target analytes at concentrations of the minimum required performance levels for the screening were 2-14% and 2-15%, respectively. The limits of detection for the screening and confirmation method were 0.1-10 ng/mL and 0.2-10 ng/mL, respectively, for 44 steroids. This method was successfully applied to analysis of urine samples from suspected anabolic steroid abusers.  相似文献   

20.
(E)-5-(2-Bromovinyl)-2'-deoxyuridine is an antiviral drug that is experimentally used for modulation of the antitumour effect of fluoropyrimidines, such as ftorafur and 5-fluorouracil. The isolation of the analyte, in the presence of 5-fluorouracil, from the matrix is performed either by means of a simple protein precipitation (plasma) or by means of a liquid-liquid extraction with ethyl acetate (urine). Following pretreatment, the analyte is analysed by reversed-phase chromatography and quantified by absorbance detection at 307 nm. The minimum detectable concentration in plasma and urine samples is ca. 6 ng/ml. The recovery after deproteination of plasma samples is 75%, while after liquid-liquid extraction of urine the recovery amounts 92%. The degree of protein binding of the analyte, measured by ultrafiltration, is found to be 97%. These data allow the bioanalysis of (E)-5-(2-bromovinyl)-2'-deoxyuridine for pharmacokinetic studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号