首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
For separation of enantiomers in presence of a chiral selector, data obtained with the 1D dynamic simulators SIMUL5complex and GENTRANS are compared to data predicted by PeakMaster 6, a recently released generalized model of the linear theory of electromigration. Four electrophoretic systems with stereoisomers of weak bases were investigated. They deal with the estimation of input data for complexation together with the elucidation of the origin of observed system peaks, the interference of analyte and system peak migration, the change of enantiomer migration order as function of the selector concentration and the inversion of analyte migration direction in presence of a multiply negatively charged selector. For all systems, data predicted with PeakMaster 6 are in agreement with those of the dynamic simulators and simulation data compare well with experimental data that were monitored with setups featuring conductivity and/or UV absorbance detection along the capillary. SIMUL5complex and GENTRANS provide the full dynamics of any buffer and sample arrangement and require very long execution time intervals. PeakMaster 6 is restricted to conventional CZE, is based on an approximate solution of the transport equations, provides data for realistic experimental conditions within seconds and represents a practical tool for an experimentalist.  相似文献   

2.
饮用水中9种卤乙酸的超高效液相色谱法测定   总被引:1,自引:0,他引:1  
建立了固相萃取/超高效液相色谱(SPE/UPLC)测定饮用水中9种痕量卤乙酸(HAAs)的分析方法.对固相萃取和液相色谱等分析条件进行了优化,选择Lichrolut EN固相萃取小柱富集饮用水中的HAAs,三乙胺-磷酸缓冲液和甲醇作为UPLC的流动相.在优化的分析条件下,9种卤乙酸在6min内实现基线分离,所有目标物在一定质量浓度范围内线性良好,相关系数为0.995 7~0.9999;一氯乙酸(MCAA)的检出限为10.85μg/L,其它8种化合物的检出限为0.25~0.70μg/L;除MCAA外,其它目标物在低、中、高3种加标水平的回收率为60%~106%.方法的相对标准偏差(RSD,n=5)为2.0%~5.7%.将此方法应用于我国北方某城市自来水中卤乙酸的测定,5种HAAs被检出.方法灵敏度高、简便快捷,可用于生活饮用水中痕量卤乙酸的测定.  相似文献   

3.
Capillary electrophoresis (CE) was applied to analyse the long-chain fatty acid composition of vegetable oils, and their degradation products formed upon ageing when drying oils are used as binding media. The analytes were detected with contactless conductivity detection (CCD) and indirect UV absorption, both detectors positioned on-line at the separation capillary. The long-chain fatty acids were resolved in a background electrolyte (BGE) consisting of phosphate buffer (pH = 6.86, 15 mM) containing 4 mM sodium dodecylbenzensulfonate, 10 mM Brij 35, 2% (v/v) 1-octanol and 45% (v/v) acetonitrile. As in this system dicarboxylic analytes, the products of oxidative degradation of unsaturated fatty acids, cannot be determined, a suitable background electrolyte was developed by the aid of computer simulation program PeakMaster. It makes use of a 10 mM salicylic acid, 20 mM histidine buffer, pH 5.85, which combines buffering ability with the optical properties obligatory for indirect UV detection. This buffer avoids system eigenpeaks, which are often impairing the separation efficiency of the system. Separation of the dicarboxylic analytes was further improved by a counter-directed electroosmotic flow (EOF), obtained by dynamically coating the capillary wall with 0.2 mM cetyltrimethylammonium bromide. Long-chain fatty acids and their decomposition products could be determined in recent and aged samples of drying oils, respectively, and in samples taken from two paintings of the 19th century.  相似文献   

4.
We introduce a computer implementation of the mathematical model of capillary zone electrophoresis described in the previous paper in this issue (Hru?ka et al., Electrophoresis 2012, 33), the program PeakMaster 5.3. The computer model calculates eigenmobilities, which are the eigenvalues of the Jacobian matrix of the electromigration system, and which are responsible for the presence of system eigenzones (system zones, system peaks). The model also calculates parameters of the background electrolyte: pH, conductivity, buffer capacity, ionic strength, etc., and parameters of the separated analytes: effective mobility, transfer ratio, molar conductivity detection response, and relative velocity slope. In addition to what was possible in the previous versions of PeakMaster, Version 5.3 can predict the shapes of the system peaks even for a complex injected sample profile, such as a rectangular plug. PeakMaster 5.3 can replace numerical simulation in many practically important configurations and the results are obtained in a very short time (within seconds). We demonstrate that the results obtained in real experiments agree well with those calculated by PeakMaster 5.3.  相似文献   

5.
Investigations into the thermodynamic parameters that characterize the binding of citrate to tris-guanidinium host 1 in water are reported. The parameters K(a), DeltaH degrees, DeltaS degrees, and DeltaG degrees for the binding event were quantified using isothermal titration calorimetry (ITC) techniques. The 1:1 binding stoichiometry was verified by a Job plot derived from NMR data, and the microcalorimetry data was collected for solutions of 1 and citrate ranging from 1 to 100 mM using phosphate buffer concentrations of 5 and 103 mM. At low buffer concentrations (low ionic strength) complexes with greater than 1:1 stoichiometries were observed by ITC, and K(1) was determined to range from 2.0 x 10(3) to 3.0 x 10(3) M(-1). At higher buffer concentrations (high ionic strength) the higher-order complexes were not detected, and K(1) was determined to be 409 M(-1). The 1:1 association of host 1 and citrate is characterized by a large favorable entropy component and negative enthalpy. However, the complexes with higher-order stoichiometry arise from desolvation processes that result from the association of polyions in aqueous media and is entirely entropy driven. This leads to an unusual observation: the dilution of one component of the host/guest complex leads to the formation of the higher-order complexes. The reason for this observation is discussed.  相似文献   

6.
Bicarbonate and phosphate constitute major salivary buffering components, and their importance consists in the neutralization of acidic gastric contents during reflux episodes. In this work, capillary electrophoresis with capacitively coupled contactless conductivity detector was applied for the analysis of bicarbonate, phosphate, and another inorganic (chloride, nitrite, nitrate, sulfate, thiocyanate) and organic anions (acetate, butyrate) to evaluate their levels in saliva. The background electrolytes of different composition and pH between 6.02–9.41 were assessed for the bicarbonate and phosphate determination by comparison of the real analyses of a model solution with the simulation by PeakMaster software. The optimized background electrolyte was composed of 10 mM 2-(N-morpholino)ethanesulfonic acid, 20 mM arginine, and 30 µM cetyltrimethylammonium bromide, pH 8.95. Using this BGE, the anion levels were compared in saliva from 20 patients suffering from gastroesophageal reflux disease (GERD) and saliva from 12 healthy subjects. Bicarbonate levels were significantly elevated in saliva from GERD patients suggesting the possible applicability of bicarbonate as a biomarker in non-invasive diagnostics of GERD by CE-C4D.  相似文献   

7.
Disinfection by products of haloacetic acids and perchlorate pose significant health risks, even at low microg/l levels in drinking water. A new method for the simultaneous determination of nine haloacetic acids (HAAs) and perchlorate as well as some common anions in one run with ion chromatography was developed. The HAAs tested included mono-, di-, trichloroacetic acids, mono, di-, tribromoacetic acids, bromochloroacetic acid, dibromochloroacetic acid, and bromodichloroacetic acid. Two high-capacity anion-exchange columns, a carbonate-selective column and a hydroxide-selective hydrophilic one, were used for the investigation. With the carbonate-selective column, the nine HAAs as well as fluoride, chloride, nitrite, nitrate, phosphate and sulfate could be well separated and determined in one run. With the very hydrophilic column and a gradient elution of sodium hydroxide, methanol and deionized water, the nine HAAs, fluoride, chloride, nitrite, nitrate as well as perchlorate could be simultaneously determined in one run within 34 min. The detection limits for HAAs were between 1.11 and 9.32 microg/l. For perchlorate, it was 0.60 microg/l.  相似文献   

8.
Lin CE  Liao WS  Chen KH 《Electrophoresis》2003,24(18):3139-3146
Enantioseparations of phenothiazines with gamma-cyclodextrin (gamma-CD) as a chiral selector were investigated using citrate and phosphate buffer electrolytes at pH 3.0. Reversal of the enantiomer migration order of promethazine, ethopropazine, and trimeprazine was observed by varying gamma-CD concentration in the range of 5-9 mM, 2.5-4.5 mM and 1.5-2.8 mM, respectively, using 100 mM citrate buffer at pH 3.0. As in the case of beta-CD, the (+)-enantiomers of phenothiazines possess greater binding strength to gamma-CD than the (-)-enantiomers. The evaluation of the binding constants and limiting mobility of the complexes formed between the enantiomers of phenothiazines and gamma-CD reveals that the binding strength of phenothiazines to gamma-CD and the differences in the binding constants and limiting mobility of the complexes are responsible for the enantiomer migration reversal. Both the binding constants and limiting mobility of the complexes between the (+)-enantiomers of phenothiazine and gamma-CD are greater than those of the corresponding (-)-enantiomers in a citrate buffer, while the binding constants of the complexes primarily determined the migration order of the enantiomers in a phosphate buffer. Compared with the results obtained using a phosphate buffer, we may conclude that citrate buffer which involves competitive complexation with chiral selector plays a significant role in the enantiomer migration reversal.  相似文献   

9.
A new way to determine the critical micelle concentration (CMC) based on the mobilities of system peaks is presented. A general approach for the CMC determination is based on the change of the slope or on finding the inflection point in the plot of a physical property of solution as a function of surfactant concentration. The determination of CMC by system peaks in CE utilizes a "jump" instead of a continuous change in the measured quantity. This phenomenon was predicted by the program PeakMaster, which was modified for simulation of micellar systems. The simulation of the steep change in mobilities of the anionic system peaks showing the CMC value was verified experimentally in a set of measurements, where the concentration of the surfactant was varied while the ionic strength was kept constant. The experimental work fully proved our model. A comparative electric current measurement was carried out. The proposed method seems to offer easier CMC determination as compared to the standard methods.  相似文献   

10.
The influences of buffer pH, buffer concentration and buffer electrolyte on the migration behavior and separation of 12 cephalosporin antibiotics in capillary zone electrophoresis using three different types of buffer electrolyte, including phosphate, citrate, and 2-(N-morpholino)ethanesulfonate (MES), were investigated. The results indicate that, although buffer pH is a crucial parameter, buffer concentration also plays an important role in the separation of cephalosporins, particularly when cefuroxime and cefazolin, cephalexin and cefaclor, or cefotaxime and cephapirin are present as analytes at the same time. The electrophoretic mobility of cephalosporins and electroosmotic mobility measured in citrate and MES buffers are remarkably different from those measured in phosphate buffer. With citrate buffer, optimum buffer concentration is confined to a small range (35-40 mM), whereas buffer concentrations up to 300 mM can be used with MES buffer. Complete separations of 12 cephalosporins could be satisfactorily achieved with these three buffers under various optimum conditions. However, the separability of 12 cephalosporins with citrate or MES buffer is better than that with phosphate buffer. As a consequence of a greater electrophoretic mobility of cephalosporins than the electroosmotic mobility with citrate buffer at pH below about 5, some cephalosporins are not detectable. The cloudiness of the peak identification and of the magnitudes of the electrophoretic mobility of cefotaxime and cefuroxime reported previously are clarified. In addition, the pKa values of cephradine, cephalexin, cefaclor, and cephapirin attributed to the deprotonation of either an amino group or a pyridinium group are reported, and the migration behavior of these cephalosporins in the pH range studied is quantitatively described.  相似文献   

11.
Capillary electrophoresis (CE) with direct UV detection is proposed for speciation of inorganic Se in high-level liquid waste. In this aim, the optimal conditions of measurements (pH, electrolyte buffer concentration) and the influence of nitrate excess on the quantitative determination of Se(IV) and Se(VI) were studied. Different electrolyte buffers were considered: carbonate, phosphate and citrate. It was found, that citrate buffer is the most suitable for the application under consideration. Under the chosen optimal conditions (20 mmol L(-1) citrate buffer, pH 2.5), calibration curves for Se(IV) and Se(VI) are linear in the concentration range 10(-4)-10(-3) mol L(-1). The detection limits are 4x10(-6 )for Se(IV) and 2x10(-5) for Se(VI). The accuracy of the procedure was checked by calculating the recovery by spiking simulation solutions. Relative standard deviation (S(r)) is less than 10%.  相似文献   

12.
Abstract

Retention behaviour of ionogenic species in high-performance liquid chromatography on reversed phase materials was studied, specifically dependence of buffer quality applied to mobile phases. The buffers' effect on retention of organic acids, amino acids and dipeptides is quantified by modelling capacity factors as a function of pH-values. At constant ionic strength, increasing capacity factors were observed going from phosphate to less polar citrate buffer, modification of accessible silanol groups of the stationary phase being responsible for this effect. Application of citrate buffer for separation of a seven-component mixture is demonstrated on the basis of a computerized search for optimum chromatographic performance. The evaluated factor levels (pH, methanol content and ionic strength) differ from those found using phosphate buffer-containing mobile phases.  相似文献   

13.
14.
Acetylcysteine and captopril can be determined in pharmaceutical formulations after precolumn derivatization of the thiol with 1-benzyl-2-chloropyridinium bromide (BCPB) by reversed-phase ion-pair HPLC separation and UV detection. The thiol group of the drugs reacts with BCPB in 0.1 mol/L phosphate buffer (pH 8) to form S-pyridinium derivatives showing an absorption maximum at 314 nm. The S-pyridinium derivative was separated isocratically on an Asahipak ODP-50 column at 45°C with 0.2 mol/L citrate buffer containing 10 mmol/L of sodium octanesulfonate (pH 2.5) and acetone (4:1, v/v). Calibration curves for both analytes were linear over the range of 2–20 μg/mL with variation coefficients of 3.12–1.28% for acetylcysteine and 9.22–1.51% for captopril.  相似文献   

15.
On the basis of gas chromatography(GC) coupled with a short capillary column and an electron capture detector(ECD), a simple and rapid method for the determination of five haloacetic acids(HAAs) in drinking water was developed by the optimization of derivation conditions and the modification of gas chromatographic program. HAAs formation potential(HAAFP) of the reaction of humic acid with chlorine was determined via this method. The major advantages of the method are the simplicity of chromatographic temperature program and the short run time of GC. Dichloroacetic acid(DCAA) and Trichloroacetic acid(TCAA), which were detected in the determination of HAAFP, were rapidly formed in the first 72 h of the reaction of humic acid with chlorine. HAAFP of the reaction of humic acid with chlorine increased with the increase in the concentrations of humic acid and chlorine. The average HAAFP of the reaction of humic acid with chlorine was 39.9 μg/mg TOC under the experimental conditions. When the concentration of humic acid was 4 mg/L, the concentration of HAAs, which were produced in the reaction of humic acid with chorine, may exceed MCL of 60 μg/L HAAs as the water quality standards for urban water supply of China and the first stage of US EPA disinfection/disinfection by-products(D/DBP) rule; when the concentration of humic acid was 2 mg/L, the concentration of HAAs may exceed MCL of 30 μg/L HAAs for the second stage of US EPA D/DBP rule. When humic acid was reacted with chlorine dioxide, only DCAA was detected with a maximum concentration of 3.3 μg/L at a humic acid content of 6 mg/L. It was demonstrated that the substitution of chlorine dioxide for chorine may entirely or partly control the formation of HAAs and effectively reduce the health risk associated with disinfected drinking water.  相似文献   

16.
Haloacetic acids (HAAs) were determined in different water samples by a new, fast and simple analysis method based on enrichment of 50-ml water samples at pH 1.8 by solid-phase extraction (SPE) followed by liquid chromatography (LC) separation and electrospray ionization mass spectrometric detection in the negative ionization mode. Deprotonated (M-H)-haloacetates and decarboxylated (M-COOH)- ions were detected. Different polymeric SPE sorbents were tested, and LiChrolut EN was found to be the best material for the extraction. Complete LC separation of all compounds could only be achieved by ion-pair chromatography using triethylamine as volatile ion-pairing reagent. The detection limits were in the low microg/l range. High microg/l concentration levels for the chlorinated and brominated haloacetates were found in drinking water from a drinking water treatment plant in Barcelona, and the corresponding tap water. In swimming pool water samples from Catalonia mg/l levels and in surface river water from Portugal microg/l values were detected. These results confirm other recent reports on the ubiquitous occurrence of HAAs in aqueous environments.  相似文献   

17.
Huang Y  Zhang Z  Zhang D  Lv J 《Talanta》2001,53(4):835-841
The bovine serum album binding of streptomycin sulfate was studied in vitro using the technique of microdialysis combined with flow-injection analysis-chemiluminescence detection. The principle of the determination of streptomycin sulfate is that it increases the radiation emitted during the chemiluminescence oxidation of luminol by potassium hexacyanoferrate (III) in sodium hydroxide medium. The drug and protein were mixed in different molar ratios in 0.067 M phosphate buffer, pH 7.4, and incubated at 37 degrees C in a water bath. The microdialysis probe was utilized to sample the mixed solution at a perfusion rate of 5 mul min(-1). The concentration of unbound streptomycin sulfate in the microdialysate was determined by FIA-CL. In vitro recovery of streptomycin sulfate under experimental conditions was 22%. The data obtained by the present microdialysis-FI-CL system was analyzed using the Scatchard analysis and Klotz plot. The results show that the Scatchard plot and Klotz plot are linear, showing that studied drug has only one type of binding sites. The estimated binding parameters agreed well with literature values.  相似文献   

18.
Two in‐line enrichment procedures (large volume sample stacking (LVSS) and field amplified sample injection (FASI)) have been evaluated for the CZE analysis of haloacetic acids (HAAs) in drinking water. For LVSS, separation on normal polarity using 20 mM acetic acid–ammonium acetate (pH 5.5) containing 20% ACN as BGE was required. For FASI, the optimum conditions were 25 s hydrodynamic injection (3.5 kPa) of a water plug followed by 25 s electrokinetic injection (?10 kV) of the sample, and 200 mM formic acid–ammonium formate buffer at pH 3.0 as BGE. For both FASI and LVSS methods, linear calibration curves (r2>0.992), limit of detection on standards prepared in Milli‐Q water (49.1–200 μg/L for LVSS and 4.2–48 μg/L for FASI), and both run‐to‐run and day‐to‐day precisions (RSD values up to 15.8% for concentration) were established. Due to the higher sensitive enhancement (up to 310‐fold) achieved with FASI‐CZE, this method was selected for the analysis of HAAs in drinking water. However, for an optimal FASI application sample salinity was removed by SPE using Oasis WAX cartridges. With SPE‐FASI‐CZE, method detection limits in the range 0.05–0.8 μg/L were obtained, with recoveries, in general, higher than 90% (around 65% for monochloroacetic and monobromoacetic acids). The applicability of the SPE‐FASI‐CZE method was evaluated by analyzing drinking tap water from Barcelona where seven HAAs were found at concentration levels between 3 and 13 μg/L.  相似文献   

19.
高效液相法测定牛肉干制品中10种杂环胺含量   总被引:4,自引:0,他引:4  
Wan K  Peng Z  Shao B  Yao Y  Shi J 《色谱》2012,30(3):285-291
建立了固相萃取-高效液相色谱同时分析牛肉干制品中10种杂环胺含量的方法。样品经二氯甲烷(含5%甲苯)萃取,丙基磺酸(PRS)柱和C18固相萃取小柱净化后,以甲醇-氨水定容,经TSK-gel ODS-80TM色谱柱分析,采用乙腈和0.05 mol/L醋酸-醋酸铵缓冲液(pH 3.5)作为流动相进行梯度洗脱,紫外-荧光检测器的串联方式检测杂环胺含量。结果表明,10种杂环胺在线性范围内线性关系良好,相关系数r>0.999,检出限为0.02~2.46 ng/g。杂环胺的加标回收率为61.69%~101.81%,相对标准偏差(RSD)为0.28%~7.81%。8种市售牛肉干制品中均检测出1-甲基-9H-吡啶并[4,3-b]吲哚(Harman)和9H-吡啶并[4,3-b]吲哚(Norharman),可测杂环胺总量为16.65~60.38 ng/g。该方法线性范围广,灵敏度高,净化效果好,可满足实际样品分析的需求。  相似文献   

20.
The activity of cellulase has traditionally been described by pH and temperature; however, the buffering medium is also an important factor, Taking plain water as a reference medium, three kinds of buffer including KH2PO4/K5HPO4, citric acid/sodium citrate, and acetic acid/sodium acetate were adopted to survey their effects on the activity of cellulase. Chromatographic assays indicated that xylose, glucose, and cellobiose were the major products and that minor products such as cellotriose and cellotetraose were present in some cases. The activities of cellulase based on glucose production showed that the phosphate buffer acted as a deactivator for cellulase and each of the two organic acid buffers acted as activators for cellulase. The concentration of activation buffer should be high to reach a high cellulase activity; however, this effect would be compensated for by the product inhibition of cellulase. The highest activity obtained was 4.16 ± 0.08 (× 10?3) IU mg?1 for the citric acid/sodium citrate buffer under pH 4.80, 40 °C and an agitation speed of 150 rpm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏