1.
2.
Sonodynamic therapy involving the non-invasive and local generation of lethal reactive oxygen species (ROS) via ultrasound (US) with sonosensitizers has been proposed as an emerging tumor therapy strategy. However, such therapy is usually associated with inertial cavitation and unnecessary damage to healthy tissue because current sonosensitizers have insufficient sensitivity to US. Here, we report the use of a new proposed sonosensitizer, carbon dots (C-dots), to assemble microbubbles with a gas core (C-dots MBs). As the C-dots were directly integrated into the MB shell, they could effectively absorb the energy of inertial cavitation and transfer it to ROS. Our results revealed the appearance of 1O2, •OH, and H2O2 after US irradiation of C-dots MBs. In in vitro experiments, treatment with C-dots MBs plus US induced lipid peroxidation, elevation of intracellular ROS, and apoptosis in 32.5%, 45.3%, and 50.1% of cells respectively. In an animal solid tumor model, treatment with C-dots MBs plus US resulted in a 3-fold and 2.5-fold increase in the proportion of ROS-damaged cells and apoptotic cells, respectively, compared to C-dots MBs alone. These results will pave the way for the design of novel multifunctional sonosensitizers for SDT tumor therapy.  相似文献   

3.
微泡对高强度聚焦超声(HIFU)治疗具有增效作用,而HIFU治疗中不同声学条件下微泡对HIFU治疗焦域的影响尚不清楚。本文基于声传播方程、Yang-Church气泡运动方程、生物热传导方程、时域有限差分法(FDTD)、龙格-库塔(RK)法数值仿真研究输入功率、激励频率和气泡初始半径对HIFU在含气泡体模中形成焦域的影响,并利用含Sono Vue造影剂的仿组织体模研究进行实验验证。结果表明,增大输入功率、气泡初始半径和升高激励频率均可增大焦域,随着输入功率的增大,焦域形状可能发生变化,而随着激励频率升高和气泡初始半径的增大,焦域会向远离换能器的方向移动。  相似文献   

4.
This paper demonstrated the use of flowing microbubbles (MBs) to minimize thermal losses from perfusion during focused ultrasound exposures due to acoustic cavitation. Temperature and cavitation were simultaneously investigated as MBs flowing through a wall-less flow phantom with varying flow velocities (2-55 cm/s) and concentrations (0%-0.1%) when exposed at different acoustic power levels (5-120 W). The peak temperature at the end of ultrasonic exposures in the flow and in the outer of the vessel as well as the cavitation were higher than those pure controls measured at the same exposure parameters and flow velocities but without MBs. All the peak temperatures initially increased with increasing flow velocities of MBs, followed by a decrease of the peak temperatures with increasing flow velocities when the velocity was higher than the inflection velocity. Meanwhile, cavitation showed a trend of increases with increasing flow velocity. The inflection velocity and cavitation increased with increasing acoustic power and MBs concentration. Thermal lesion appeared around the vessel as MBs flow through the vessel, at which lesion was not observed originally without MBs. These results suggested that this may provide an effective way to minimize thermal losses from perfusion during focused ultrasound exposures.  相似文献   

5.
为了研究脑组织和脑肿瘤组织在HIFU治疗时形成焦域的特性及坏死肿瘤组织、不同治疗剂量参数以及多次治疗时焦点间距和时间间隔对HIFU形成焦域的影响,本文以脑胶质瘤患者为例,利用患者头颅CT图像数据建立HIFU经颅治疗的仿真模型,基于Westervelt声波非线性传播方程和Pennes生物热传导方程进行HIFU经颅治疗的仿真研究。结果表明,脑组织和脑肿瘤组织内形成HIFU焦域的差异较小,坏死肿瘤组织对HIFU温度场分布有较小影响;辐照声强越大,焦点温升达到同一温度所用时间越短,焦域长短轴越短,颅骨处温升越低;当焦点间距在一定范围内时,第一次辐照形成的温度场分布对第二个焦点温升达到同一温度所需时间影响较大;两次辐照时间间隔对颅骨处温升和两次聚焦形成60?C以上温度分布影响较小。  相似文献   

6.
Many studies have shown that microbubble cavitation is one mechanism for vascular injury under ultrasonic excitation. Previous work has attributed vascular damage to vessel expansions and invaginations due to the expansion and contraction of microbubbles. However, the mechanisms of vascular damage are not fully understood. In this paper, we investigate, theoretically and experimentally, the vessel injury due to stress induced by ultrasound-induced cavitation (UIC). A bubble-fluid-vessel coupling model is constructed to investigate the interactions of the coupling system. The dynamics process of vessel damage due to UIC is theoretically simulated with a finite element method, and a focused ultrasound (FU) setup is carried out and used to assess the vessel damage. The results show that shear stress contributes to vessel injury by cell detachment while normal stress mainly causes distention injury. Similar changes in cell detachment in a vessel over time can be observed with the experimental setup. The severity of vascular injury is correlated to acoustic parameters, bubble-wall distance, and microbubble sizes, and the duration of insonation..  相似文献   

7.
Transcranial magnetic resonance-guided focused ultrasound (tMRgFUS) allows to perform incisionless thermoablation of deep brain structures. This feature makes it a very useful tool for the treatment of multiple neurological and psychiatric disorders. Currently, feedback of the thermoablation process is based on peak temperature readings assessed on real-time two-dimensional MRI thermometry. However, an accurate methodology relating thermal dosimetry with three-dimensional topography and temporal evolution of the lesion is still to be defined, thus hurdling the establishment of well-defined, evidence-based criteria to perform safe and effective treatments. In here we propose threshold-based thermoablation models to predict the volumetric topography of the lesion (whole lesion and necrotic core) in the short-to-mid-term based on thermal dosimetry estimated from intra-treatment MRI thermometry. To define and validate our models we retrospectively analyzed the data of sixty-three tMRgFUS thalamotomies for treating tremor. We used intra-treatment MRI thermometry to estimate whole-treatment three-dimensional thermal dose maps, defined either as peak temperature reached (Tmax) or thermal isoeffective dose (TID). Those maps were thresholded to find the dosimetric level that maximize the agreement (Sorensen-Dice coefficient - SDc) with the boundaries of the whole lesion and its core, assessed on T2w images 1-day (post-24h) and 3-months (post-3M) after treatment. Best predictions were achieved for the whole lesion at post-24h (SDc = 0.71), with Tmax /TID over 50.0 °C/90.5 CEM43. The core at post-24h and whole lesion at post-3M lesions reported a similar behavior in terms of shape accuracy (SDc ~0.35), and thermal dose thresholds ~55 °C/4100.0 CEM43. Finally, the optimal levels for post-3M core lesions were 55.5 °C/5800.0 CEM43 (SDc = 0.21). These thermoablation models could contribute to the real-time decision-making process and improve the outcome of tMRgFUS interventions both in terms of safety and efficacy.  相似文献   

8.
微泡对高强度聚焦超声声压场影响的仿真研究*   总被引:2,自引:1,他引:1  
微泡对高强度聚焦超声(HIFU)治疗焦域具有增效作用,而HIFU治疗中不同声学条件下微泡对HIFU形成声压场的影响尚不清楚。本文基于气液混合声波传播方程、Keller气泡运动方程、时域有限差分(FDTD)法和龙格-库塔(RK)法数值仿真研究输入声压、激励频率、气泡初始空隙率和气泡初始半径对HIFU形成声压场的影响。研究结果表明,随着输入声压的增大,焦点处声压升高但焦点处最大声压与输入声压的比值减小,焦点位置几乎不变;随着激励频率和气泡初始半径的增大,焦点处声压升高且焦点位置向远离换能器方向移动;随着气泡初始空隙率的增大,焦点处声压降低且焦点位置向换能器方向移动。  相似文献   

9.
郭各朴  张春兵  屠娟  章东 《物理学报》2015,64(11):114301-114301
包膜黏弹特性显著影响微气泡超声造影剂的诊断及治疗应用效果. 本文结合原子力显微镜技术及声衰减特性测量提出了一种对微气泡造影剂包膜黏弹特性定量表征的新方法. 首先采用原子力显微镜技术进行机械特性分析得到包膜微气泡的有效硬度及体弹性模量; 然后测量声衰减特性, 基于微气泡动力学理论, 计算包膜微气泡的体黏度系数. 为验证方法的有效性, 实验制备了直径为1-5 μm的白蛋白包膜微气泡造影剂, 原子力显微镜测量的有效硬度和体弹性模量分别为0.149±0.012 N/m和8.31±0.667 MPa, 并与粒径无关. 声衰减特性测量和动力学理论拟合的包膜微气泡的体黏度系数为0.374±0.003 Pa·s. 该方法可推广至其他种类包膜微气泡的黏弹特性表征, 对超声造影剂的制备及其诊断和治疗应用有积极意义.  相似文献   

10.
近年大鼠等动物实验表明经颅聚焦超声联合微泡技术可无创开放血脑屏障实现药物递送,但在临床治疗时由于人体头颅非均质结构及其高声衰减特性,需优化超声经颅聚焦参数和微泡参数。本文基于人头颅CT数据、82阵元相控换能器和血管建立了三维数值仿真模型,研究超声及微泡参数对机械指数和靶区声发射的影响,评估血脑屏障开放程度及组织损伤的可能性。结果表明,声功率和微泡初始密度增大,机械指数和宽带噪声强度增大;频率增大,稳态空化强度增大;当微泡初始半径大于5μm时,稳态空化显著增强。该研究结果为经颅聚焦超声联合微泡技术诱导可控的BBB开放及安全有效递送治疗药物提供了理论数据和技术参考。  相似文献   

11.
Advances in neuroscience have resulted in the development of new diagnostic and therapeutic agents for potential use in the central nervous system (CNS). However, the ability to deliver the majority of these agents to the brain is limited by the blood-brain barrier (BBB), a specialized structure of the blood vessel wall that hampers transport and diffusion from the blood to the brain. Many CNS disorders could be treated with drugs, enzymes, genes, or large-molecule biotechnological products such as recombinant proteins, if they could cross the BBB. This article reviews the problems of the BBB presence in treating the vast majority of CNS diseases and the efforts to circumvent the BBB through the design of new drugs and the development of more sophisticated delivery methods. Recent advances in the development of noninvasive, targeted drug delivery by MRI-guided ultrasound-induced BBB disruption are also summarized.  相似文献   

12.
A new quantitative method has been developed for real-time mapping of temperature changes induced by high intensity focused ultrasound (HIFU). It is based on the temperature dependence of the T1 relaxation time and the equilibrium magnetization. To calibrate the temperature measurement, the functional relationship between T1 and temperature was examined in different samples of porcine muscle and fatty tissue. The method was validated by a comparison of calculated temperature maps with fiber-optic measurements in heated muscle tissue. The experiment showed that the accuracy of the MR method for temperature measurements is better than 1 degree C. Since the acquisition time of the employed MR sequence takes only 3 s per slice and the calculation of the temperature map can be performed within seconds, the imaging technique works nearly in real-time. The temperature measurement could be realized during HIFU showing no disturbances by ultrasound sonication. In comparison to other MR approaches, the advantages of the introduced method lie in a sufficient accuracy and time resolution combined with a reasonable robustness against motion as well as the feasibility for temperature monitoring in fatty tissues.  相似文献   

13.
The activation of bubbles by an acoustic field has been shown to temporarily open the blood-brain barrier (BBB), but the trigger cause responsible for the physiological effects involved in the process of BBB opening remains unknown. Here, the trigger cause (i.e., physical mechanism) of the focused ultrasound-induced BBB opening with monodispersed microbubbles is identified. Sixty-seven mice were injected intravenously with bubbles of 1-2, 4-5, or 6-8 μm in diameter and the concentration of 10(7) numbers/ml. The right hippocampus of each mouse was then sonicated using focused ultrasound (1.5 MHz frequency, 100 cycles pulse length, 10 Hz pulse repetition frequency, 1 min duration). Peak-rarefactional pressures of 0.15, 0.30, 0.45, or 0.60 MPa were applied to identify the threshold of BBB opening and inertial cavitation (IC). Our results suggest that the BBB opens with nonlinear bubble oscillation when the bubble diameter is similar to the capillary diameter and with inertial cavitation when it is not. The bubble may thus have to be in contact with the capillary wall to induce BBB opening without IC. BBB opening was shown capable of being induced safely with nonlinear bubble oscillation at the pressure threshold and its volume was highly dependent on both the acoustic pressure and bubble diameter.  相似文献   

14.
Zhou XB  Qin H  Li J  Wang B  Wang CB  Liu YM  Jia XD  Shi N 《Ultrasonics》2011,51(3):270-274
Microbubbles (MBs) can augment the acoustic cavitation’ (US), thereby facilitating the thrombolysis of external ultrasound. But we observed re-thrombosis after successful thrombolysis by MBs and transcutaneous ultrasound in an endothelium injury model. This study was designed to explore whether platelet-targeted MBs can prevent the reformation of thrombi. Arterial injury was induced in canine femoral arteries with balloon, and the arteries were completely thrombotically occluded. The arteries were treated with intra-arterial MBs or platelet-targeted MBs (TMB) and transcutaneous low frequency ultrasound (LFUS) to achieve complete thrombolysis. The arterial flow was monitored with angiogram for 4 h following treatment. Results showed that both MBs and TMBs produced successful dissolution of clots in the presence of ultrasound. The re-occlusion began to occur 1 h after thrombolysis in MB/LFUS treatment, and 7 of 8 arteries were re-occluded within 3 h. Most of the arteries (7 of 8) in the TMB/LFUS group remained patent for 4 h following treatment. The flow tended to decrease after thrombolysis in MB/LFUS treatment. These results indicated that platelet-targeted microbubbles were beneficial in preventing re-thrombosis in vivo and microbubbles served as good carrier of thrombolytic and anticoagulation drugs.  相似文献   

15.
为研究颅骨中的剪切波对经颅聚焦超声的影响,该文利用Kelvin-Voigt固体声波方程并结合时间反转法,分别模拟了考虑剪切波和不考虑剪切波时,256-单元平面相控阵为实现超声经颅聚焦所需的相位调控,并将这两种相位调控都分别作用于考虑剪切波和不考虑剪切波时的聚焦情形。对这两种相位调控以及基于它们的经颅聚焦超声场的对比分析结果表明:聚焦深度较大时,剪切波对基于时间反转进行的相位调控影响较小;不过,剪切波对经颅聚焦超声场的强度分布影响较大,忽略剪切波会导致对焦域处声场聚焦强度的高估以及对颅骨附近声能量沉积的低估。  相似文献   

16.
This paper compares the efficiency of flowing polymer- and lipid-shelled microbubbles (MBs) in the heating and cavitation during focused ultrasound exposures. Temperature and cavitation activity were simultaneously measured as the two types of shelled MBs and saline flowing through a 3 mm diameter vessel in the phantom with varying flow velocities (0-20 cm/s) at different acoustic power levels (0.6-20 W) with each exposure for 5 s. Temperature and cavitation for the lipid-shelled MBs were higher than those for the polymer-shelled MBs. Temperature rise decreased with increasing flow velocities for the two types of shelled MBs and saline at acoustic power 1.5 W. At acoustic power 11.1 W, temperature rise increased with increasing flow velocities for the lipid-shelled MBs. For the polymer-shelled MBs, the temperature rise increased with increasing flow velocities from 3-15 cm/s and decreased at 20 cm/s. Cavitation increased with increasing flow velocity for the two shelled MBs and there were no significant changes of cavitation with increasing flow velocities for saline. These results suggested that lipid-shelled MBs may have a greater efficiency than polymer-shelled MBs in heating and cavitation during focused ultrasound exposures.  相似文献   

17.
Radionuclide tumour therapy with ultrasound contrast microbubbles   总被引:6,自引:0,他引:6  
Radionuclides have shown to be effective in tumour therapy. However, the side effects determine the maximum deliverable dose. Recently, it has been demonstrated that cells can be permeabilised through sonoporation using ultrasound and contrast microbubbles. The use of sonoporation in treatment of tumours may increase the anti-tumour efficacy of radionuclide treatment. The mechanisms as well as the effects sonoporation in tumour treatment strategies are still not understood. The purpose of this study is to determine the effects of ultrasound and contrast microbubbles on the internalisation of the radionuclide (111)In-DOTA-Tyr(3)-octreotate in tumour cells. To optimize ultrasound settings for ultrasound adjunctive tumour therapy we incubated rat pancreatic CA20948 tumour cells with two dyes (MW 40 and 70 kDa). The uptake levels were compared with cells treated with ultrasound and contrast microbubbles for different ultrasound settings. The highest molecular uptake was found with addition of contrast microbubbles (ratio of 10 bubbles to 1 cell) and with the ultrasound setting: duty cycle 0.013%, mechanical index (MI) 0.42, and treatment times of 30 and 60 min. These settings were used to enhance the internalisation of (111)In-DOTA-Tyr(3)-octreotate. We found a 160% higher internalisation of (111)In-DOTA-Tyr(3)-octreotate by tumour cells adjunctively treated with ultrasound and contrast microbubbles compared to untreated cells. These results show that adjunctive tumour treatment with the radionuclide (111)In-DOTA-Tyr(3)-octreotate and ultrasound contrast microbubbles may be feasible. When using adjunctive ultrasound contrast microbubble treatment, a lower radionuclide doses are required to reach the same anti-tumour effect.  相似文献   

18.
High intensity pulsed ultrasound, interacting with microbubble contrast agents, is potentially useful for drug delivery, cancer treatment, and tissue ablation, among other applications. To establish the fundamental understanding on the interaction of a microbubble (in an infinite volume of water) with an ultrasound pressure field, a numerical study is performed using the boundary element method. The response of the bubble, in terms of its shape at different times, the maximum bubble radius obtained, the oscillation time, the jet velocity, and its translational movement, is studied. The effect of ultrasound intensity and initial bubble size is examined as well. One important outcome is the determination of the conditions under which a clear jet will be formed in a microbubble in its interaction with a specific sound wave. The high speed jet is crucial for the aforementioned intended applications.  相似文献   

19.
Transcranial Magnetic Resonance guided Focused Ultrasound (TcMRgFUS) has been proven to be an effective treatment for some neurological disorders such as essential and Parkinson's tremor. However, magnetic resonance guidance at 3 Tesla (3T) frequencies and using the large hemispherical transducers required for TcMRgFUS results in artifactual low-signal bands that pass through key regions of the brain. The purpose of this work was to investigate the use of a circular conductive Radio Frequency (RF) screen, that is bent to have a 12 cm radius in one direction and positioned near the top or back of the head, to reduce or remove these artifactual low-signal bands in TcMRgFUS.The impact of using an RF screen to remove these low signal bands was studied in both imaging experiments and electromagnetic simulations. Hydrophone measurements of the acoustic transparency of the bronze 2 mm diameter square mesh screen used in the imaging studies were compared with temperature measurements with and without the screen in heating studies in the TcMRgFUS system.The imaging and simulation studies both show that for the different screen configurations studied in this work, RF screen removes the low-signal bands and increases both homogeneity and signal-to-noise ratio (SNR) throughout the region of the brain. Hydrophone and heating studies indicate that even a 2 mm wire mesh provides minimal attenuation to the ultrasound beam. Simulation results also suggest that a 1 cm mesh will provide adequate artifact suppression with even less ultrasound attenuation.An RF screen that disrupts the natural waveguide nature of the transducer in the 3T MR environment can change the electromagnetic field profile to reduce unwanted artifacts and provide an imaging region which has more homogeneity and higher SNR throughout the brain.  相似文献   

20.
The dispersion relation for a granular bed with a small amount of fine bubbles is formulated and analyzed. It is assumed that the grain size is much larger than the bubble's radius and that their volume concentration is small. The study is motivated by the problem of acoustic diagnostics of fixed bed chemical reactors operating in multiphase flow regime.  相似文献   