首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A pervaporation flow injection (PFI) method is described for the determination of ammonia in beers. After injecting the sample into a NaOH donor solution, ammonia and other volatiles are transferred in the pervaporation unit from the donor stream to an acceptor stream containing sodium salicylate and nitroprusside, which subsequently mixes with alkaline sodium dichloroisocyanurate to allow the classical Berthelot reaction to take place. The blue-coloured complex formed is monitored spectrophotometrically at 655 nm. A linear calibration curve with a range of 0.1–40 mg l−1 was obtained. The method has a detection limit of 0.05 mg l−1 and is capable of a sampling frequency of 11 h−1 at 4 mg l−1 ammonia. It was applied successfully to the determination of ammonia in synthetic samples and unfiltered lager beers. The advantages of the present method over the ammonia ion-selective electrode method and the PFI system based on mixed indicator detection are discussed.  相似文献   

2.
A supported liquid membrane system has been developed for the extraction of vanillin from food samples. A porous PTFE membrane is impregnated with an organic solvent, which forms a barrier between two aqueous phases. The analyte is extracted from a donor phase into the hydrophobic membrane and then back extracted into a second aqueous solution, the acceptor. The determination (100–1400 μg ml−1 vanillin) was performed using a PVC-graphite composite electrode versus Ag/AgCl/3MKCl at +0.850 V placed in a wall-jet flow cell as amperometric detector. The solid sample is directly placed in the membrane unit without any treatment, and the analyte was extracted from the sample, passes through the membrane and conduced to the flow cell by the acceptor stream. The limit of detection (3σ) was 44 μg ml−1. The method was applied to the determination of vanillin (9–606 μg g−1) in food samples.  相似文献   

3.
A method for the determination of total selenium in serum samples by graphite furnace atomic absorption spectrometry was evaluated. The method involved direct introduction of 1:5 diluted serum samples (1% v/v NH4OH+0.05% w/v Triton X-100®) into transversely heated graphite tubes, and the use of 10 μg Pd+3 μg Mg(NO3)2 as chemical modifier. Optimization of the modifier mass and the atomization temperature was conducted by simultaneously varying such parameters and evaluating both the integrated absorbance and the peak height/peak area ratio. The latter allowed the selection of compromise conditions rendering good sensitivity and adequate analyte peak profiles. A characteristic mass of 49 pg and a detection limit (3s) of 6 μg 1−1 Se, corresponding to 30 μg l−1 Se in the serum sample, were obtained. The analyte addition technique was used for calibration. The accuracy was assessed by the determination of total selenium in Seronorm™ Trace Elements Serum Batch 116 (Nycomed Pharma AS). The method was applied for the determination of total selenium in ten serum samples taken from individuals with no known physical affection. The selenium concentration ranged between 79 and 147 μg l−1, with a mean value of 114±22 μg l−1.  相似文献   

4.
Tang AN  Ding GS  Yan XP 《Talanta》2005,67(5):942-946
Cloud point extraction was applied as a preconcentration step for electrothermal atomic absorption spectrometry (ETAAS) determination of As(III) in aqueous solutions. After complexation with ammonium pyrrolidinedithiocarbamate, the analyte was quantitatively extracted to the surfactant-rich phase in the non-ionic surfactant octylphenoxypolyethoxyethanol (Triton X-114) after centrifugation. 0.1 mol L−1 HNO3 in methanol was added to the surfactant-rich phase before ETAAS determination. The precision (R.S.D.) for 11 replicate determinations of 5.0 μg L−1 of As(III) was 3.0%. The concentration factor, which is defined as the concentration ratio of the analyte in the final diluted surfactant-rich extract ready for ETAAS determination and in the initial solution, was 36 for As(III). The linear concentration range was from 0.1 to 20 μg L−1. The developed method was applied to the determination of As(III) in lake water and river water.  相似文献   

5.
A low solvent consumption method for Fourier transform infrared spectroscopy (FT-IR) determination of doxylamine succinate in pharmaceuticals has been developed. The analyte was continuous and selectively extracted with a 13% (v/v) ethanol:chloroform solvent mixture, recirculating the solvent through the sample and monitoring the process by FT-IR. Doxylamine succinate was determined by on-line standard addition measuring the peak area in the regions 1730–1710 and 1485–1462 cm−1 corrected with a two-point baseline established between 2000 and 1800 cm−1. This new method implies low volumes of chloroformic solvent mixture, only 2.6 mL per sample, in front of classical batch FT-IR methods, improving analytical efficiency and reducing waste generation. The on-line extraction and standard addition determination of doxylamine succinate allowed a throughput of 10 h−1.  相似文献   

6.
Four solid-phase reagents have been tested for indirect determination of cyanide using flow injection analysis-flame atomic absorption spectrometry (FIA-FAAS). The method is based on insertion of aqueous cyanide solutions into an on-line Ag2X (where X are SO32−, Cr2O72−, C2O42− and CO32−) packed column (25%, m/m suspended on silica gel beads) and re-distilled water or sodium hydroxide are used as the carrier stream. The eluent containing the analyte as silver cyanide complexes, produced from reaction between Ag2X and cyanide, measured by flame atomic absorption spectrometry. The method is simple, fast and selective than other published FIA procedures. A relative standard deviation (R.S.D.) better than 1.12% was obtained in a repeatability study. The method was applied to the determination of cyanide in industrial electrolytic baths.  相似文献   

7.
Cao Q  Li S  He C  Li K  Liu F 《Analytica chimica acta》2007,590(2):187-194
Based on aqueous two-phase system (ATPS) of poly(ethylene glycol) (PEG)–(NH4)2SO4, a simple pretreatment approach was developed for the extraction and determination of papaverin in pericarpium papaveris. The influence factors on phase behavior of the ATPS and partition behavior of papaverin was investigated, and partition mechanism based on the hydrophobic interaction between PEG and analyte molecules was proposed. Under the optimal conditions, the extraction efficiencies for papaverin were 93–96%, and the recoveries of the added standard were 97–106% with relative standard deviations of 1.8–2.5%. Combined with a high-performance liquid chromatography (HPLC) method, this extraction technique has been successfully applied to the determination of papaverin in pericarpium papaveris with the detection limit of 2 ng mL−1 and the linear range of 0.10–10 μg mL−1. Compared with the conventional liquid–liquid extraction or solid-phase extraction, this method was more environmentally benign, more cost effective and much simpler due to the direct injection of the upper phase into HPLC system.  相似文献   

8.
The determination of tannic acid is performed in a FIA assembly on the basis of the analytical output obtained by oxidation of the acid. The analyte solution was daily prepared in a mixture of quinine as sensitiser and perchloric acid and it was injected into a pure water stream acting as a carrier. This solution merges with the mixture potassium permanganate in perchloric medium and the resulting chemiluminescence is monitored. The method was applied over the range 0.5–20 mg l−1 of tannic acid with a LOD 100 μg l−1. The reproducibility was 2.1% and the sample throughput 54 h−1. The influence of foreign substances was studied and the new method is applied to the determination of tannic acid in pharmaceutical and galenic formulations in human urine and surface waters.  相似文献   

9.
Arancibia JA  Escandar GM 《Talanta》2003,60(6):1113-1121
Two different spectrofluorimetric methods for the determination of piroxicam (PX) in serum are presented and discussed. One of them is based on the use of three-way fluorescence data and multivariate calibration performed with parallel factor analysis (PARAFAC) and self-weighted alternating trilinear decomposition (SWATLD). This methodology exploits the so-called second-order advantage of the three-way data, allowing to obtain the concentration of the studied analyte in the presence of any number of uncalibrated (serum) components. The method was developed following two different procedures: internal standard addition and external calibration with standard solutions, which were compared and discussed. The second approach investigated is based on the combination of solid-phase extraction (SPE) and room temperature fluorimetry. Both methods here presented yield satisfactory results. The concentration range in which PX could be determined in serum was 1–10 μg ml−1. The limits of quantification for the experimental solutions using the chemometric approach were 0.09 μg ml−1 for the standard addition mode and 0.12 μg ml−1 using external calibration (both for PARAFAC and SWATLD algorithms). In the solid-surface fluorimetric method, the calibration graph was linear up to 0.22 μg ml−1 and the limit of quantification was 0.02 μg ml−1.  相似文献   

10.
Ahmed MJ  Banoo S 《Talanta》1999,48(5):711-1094
The very sensitive, fairly selective direct spectrophotometric method for the determination of trace amount of vanadium (V) with 1,5-diphenylcarbohydrazide (1,5-diphenylcarbazide) has been developed. 1,5-diphenylcarbohydrazide (DPCH) reacts in slightly acidic (0.0001–0.001 M H2SO4 or pH 4.0–5.5) 50% acetonic media with vanadium (V) to give a red–violet chelate which has an absorption maximum at 531 nm. The average molar absorption coefficient and Sandell’s sensitivity were found to be 4.23×104 l mol−1 cm−1 and 10 ng cm−2 of Vv, respectively. Linear calibration graph were obtained for 0.1–30 μg ml−1 of Vv: the stoichiometric composition of the chelate is 1:3 (V: DPCH). The reaction is instantaneous and absorbance remain stable for 48 h. The interference from over 50 cations, anions and complexing agents has been studied at 1 μg ml−1 of Vv. The method was successfully used in the determination of vanadium in several standard reference materials (alloys and steels), environmental waters (potable and polluted), biological samples (human blood and urine), soil samples, solution containing both vanadium (V) and vanadium (IV) and complex synthetic mixtures. The method has high precision and accuracy (s=±0.01 for 0.5 μg ml−1).  相似文献   

11.
Wang J  Zhang C  Wang H  Yang F  Zhang X 《Talanta》2001,54(6):146-1193
A simple, fast chemiluminescence (CL) flow-injection method based on the reaction of luminol with H2O2 in the presence of a cationic surfactant (cyltrimethylammonium bromide, CTMAB) has been described for the direct determination of dichlorvos pesticide (DDVP). Under the optimal conditions, the CL intensity was linear to the DDVP concentration in the range of 0.02–3.1 μg ml−1 (r=0.9998, n=10). The relative standard deviation was 3.4% at 0.35 μg ml−1 (n=10), with a detection limit (3σ) of 0.008 μg ml−1 DDVP. The possible reaction mechanism was also discussed. This method has been successfully applied to the determination of trace DDVP residue in vegetable sample and results have been compared with that of the UV method.  相似文献   

12.
In this work an automatic photometric procedure for the determination of chlorine in bleach samples employing N,N′-diethyl-p-phenylenediamine (DPD) as chromogenic reagent is described. The procedure was based on a falling drop system where the analyte (Cl2) was collected by a DPD solution drop (50 μL) after its delivery from the sample bulk that was previously acidified. The flow system was designed based on the multicommutation process assembling a set of three-way solenoid valves, which under microcomputer control afforded facilities to handle sample and reagent solution in order to control analyte delivering and solution drop generation. The analyte volatilization was improved by coupling online a little heating device. The detection system comprised a green LED (515 nm) and a phototransistor. Aiming to prove the usefulness of the proposed procedure a set of bleach samples was analyzed. Comparing the results with those obtained with reference method no significant difference at 95% confidence level was observed. Other profitable features such as a linear response ranging from 15 up to 100 mg L−1 Cl2 (R = 0.999); a detection limit of 4.5 mg L−1 Cl2 estimated based on the 3σ criterion; a relative standard deviation of 2.5% (n = 10) using a typical bleach sample containing 25.0 mg L−1 Cl2; a consumption of 55 μg of DPD per determination; and a analytical frequency of 20 determinations per hour were also achieved.  相似文献   

13.
A flow injection-pervaporation approach, where the samples – beech or olive leaves – were introduced as slurry, has been used for continuous derivatization hydride generation and separation of cadmium prior to determination by atomic absorption spectrometry. The removal of the analyte is achieved with an 1 mol/l HCl + 16% H2O2 aqueous solution with the help of an ultrasound probe acting for 17 min. Thiourea and cobalt were also added to the slurry for kinetic catalysis of hydride generation. A CRM – beech leaves – where the analyte had not been certified but estimated was used for optimisation of the leaching step. The results obtained using direct calibration against aqueous standards demonstrated the reliability of the method. The linear concentration range of the calibration curve was from pg/ml to ng/ml, with a correlation coefficient, r2, better than 0.99. The detection and quantification limits were 0.3 and 0.9 ng/ml, respectively. The relative standard deviation for within-laboratory reproducibility was 5.7%. Olive leaves CRM was used for validation.  相似文献   

14.
Kapoor J  Kumar A  Gupta U  Rao AL 《Talanta》1994,41(12):2061-2065
A rapid, simple, direct, and sensitive method has been developed for the determination of maneb (manganese ethylenebisdithiocarbamate) based on the formation of manganese-4-(2′-pyridylazo) resorcinol complex by a ligand displacement reaction, which is rendered water soluble by a cationic surfactant cetyltrimethylammonium bromide (CTAB) by the formation of an ion association complex. Beer's law is obeyed over the concentration range 0.08–2.4 μg/ml of the final solution at 500 nm in pH range 8–12. The molar absorptivity and Sandell's sensitivity are calculated to be 8.84 × 104 l.mol−1.cm−1 and 0.003 μg/cm2, respectively. The developed method has been applied to the determination of maneb in commercial formulations, synthetic mixture, grain samples and vegetables.  相似文献   

15.
Li B  Zhang Z  Liu W 《Talanta》2001,55(6):1097-1102
A novel chemiluminescence (CL) flow system for the determination of chlortetracycline is described. It is based on the direct CL reaction of chlortetracycline and [Cu(HIO6)2]5− in KOH medium. The unstable [Cu(HIO6)2]5− was on-line electrogenerated by constant-current electrolysis. The CL intensity was linear with chlortetracycline concentration in the range of 0.1–100 μg ml−1. The determination limit was 5.3×10−8 g ml−1. The whole process could be completed in 1 min. The proposed method is suitable for automatic and continuous analysis, and has been applied satisfactorily to analysis of chlortetracycline in biological fluid.  相似文献   

16.
A flow injection wetting-film extraction system without segmentor and phase separator has been coupled to flame atomic absorption spectrometry for the determination of trace copper. Isobutyl methyl ketone (MIBK) was selected as coating solvent and 8-hydroxyquinoline (oxine) as the chelating reagent. By switching of a 8-channel valve and alternative initiation of two peristaltic pumps, MIBK, sample solution containing copper chelate of oxine, and air-segment sandwiched eluting solution (1.0 mol l−1 nitric acid) were sequentially aspirated into an extraction coil made of PTFE tubing of 360 cm length and 0.5 mm i.d. The formation of organic film in the wall of the extraction coil, extraction of the copper chelate into the organic film and back-extraction of the analyte into the eluting solution occurred consecutively when these zones aspirated into the extraction coil were propelled down the extraction coil by a carrier solution at a flow rate of 2 ml min−1. After leaving the extraction coil, the concentrated zone was transported to the nebulizer at its free uptake rate for atomization. Under the optimized conditions, an enrichment factor of 43 and a detection limit of 0.2 μg l−1 copper were achieved at a sample throughput rate of 30 h−1. Eleven determinations of a standard copper solution of 60 μg l−1 gave a relative standard deviation of 1.5%. Foreign ions possibly present in tap water and natural water did not interfere with the copper determination. The developed method has been successfully used to the determination of copper content of tap water and river water.  相似文献   

17.
Zanjanchi MA  Noei H  Moghimi M 《Talanta》2006,70(5):933-939
Diffuse reflectance spectroscopy (DRS) can be used as a rapid and sensitive method for the quantitative determination of low amounts of aluminum. In this analytical technique, the analyte in samples are extracted onto a solid sorbent matrix loaded with a colorimetric reagent and then quantified directly on the adsorbent surface. Alternatively, colored aluminum complexes formed in solution can also be immobilized onto adsorbent surface and be measured by DRS technique. Octadecyl silica disk, methyltrioctylammonium chloride–naphthalene and MCM-41 were examined as adsorbents. Eriochrome cyanine R and quinalizarin were used as coloring reagents. Optimal sorption conditions were found for each system of analyte–reagent–adsorbent. The concentration of analyte is determined using the appropriate form of the Kubelka–Munk function. We obtained for each of the aluminium–reagent–adsorbent system a calibration curve by plotting the absorbance versus the log 102[Al3+] μg ml−1. The linear dynamic range extends over two orders of magnitude within 0.01–15 μg ml−1 with little differences in the range and in the correlation coefficients among the adsorbents. We consider that for a rapid determination of aluminum a spot-test-DRS combination with a detection limit of 1.0 × 10−2 μg ml−1 is the more facile and preferred technique.  相似文献   

18.
Soylak M  Tuzen M  Mendil D  Turkekul I 《Talanta》2006,70(5):1129-1135
A solid phase extraction procedure based on biosorption of copper(II), lead(II), zinc(II), iron(III), nickel(II) and cobalt(II) ions on Aspergillus fumigatus immobilized Diaion HP-2MG has been investigated. The analytical conditions including amounts of A. fumigatus, eluent type, flow rates of sample and eluent solutions were examined. Good recoveries were obtained to the spiked natural waters. The influences of the concomitant ions on the retentions of the analytes were also examined. The detection limits (3sigma, N = 11) were 0.30 μg l−1 for copper, 0.32 μg l−1 for iron, 0.41 μg l−1 for zinc, 0.52 μg l−1 for lead, 0.59 μg l−1 for nickel and 0.72 μg l−1 for cobalt. The relative standard deviations of the procedure were below 7%. The validation of the presented procedure is performed by the analysis of three standard reference materials (NRCC-SLRS 4 Riverine Water, SRM 1515 Apple leaves and GBW 07605 Tea). The procedure was successfully applied for the determination of analyte ions in natural waters microwave digested samples including street dust, tomato paste, black tea, etc.  相似文献   

19.
A flow injection (FI) on-line solvent extraction system for electrothermal atomic absorption spectrometry (ETAAS) was developed with nickel as a model trace element. The nickel pyrrolidine-dithiocarbamate chelate was extracted on line into isobutyl methyl ketone, which was delivered into the FI system by a peristaltic pump equipped with poly(tetrafluoroethylene) tubing. The organic phase was separated from the aqueous phase by a novel gravity phase separator with a small conical cavity, and stored in a collector tube, from which 50 μl organic concentrate was introduced into the graphite tube by an air flow. ETAAS determination of the analyte was performed in parallel with the extraction process. An enrichment factor of 25 was obtained in comparison with 50 μl direct introduction while achieving a detection limit of 4 ng l−1 (3σ), and a precision of 1.5% relative standard deviation for 1.0 μg l−1 nickel (n = 11). The proposed method was successfully applied to the determination of nickel in body fluids and other biological samples.  相似文献   

20.
A rapid and simple flow-through solid phase spectrofluorimetric system is described in this paper for the determination of the diuretic amiloride in physiological fluid (serum) and pharmaceuticals. The sensor was developed in conjunction with a monochannel flow-injection analysis system with fluorimetric transduction. Amiloride was transitorily retained on cationic exchanger gel Sephadex SP-C25 placed in the detection area into the cell. The determination is carried out without any derivatization reaction, by measuring directly the intrinsic fluorescence of the analyte and using the peak height as analytical signal. The wavelengths of excitation and emission were 291 and 419 nm, respectively. Amiloride could be determined in the concentration ranges of 10–600 and 4–250 μg l−1 at a sampling rate of 24 and 30 h−1, respectively with detection limits of 0.92 and 0.33 μg l−1 for 100, and 600 μl of sample volume injected, respectively. The relative standard deviations for ten independent determinations were better than 0.65%. The method was satisfactorily applied to the determination of amiloride in spiked biological fluids (serum) and pharmaceutical preparations without any pretreatment of the samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号