首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
An original method based on LC-MS for determination of the flame retardant tetrabromobisphenol A (TBBPA) in air is presented, as an alternative to the traditionally used GC-MS. The soft ionization in LC-MS makes it possible to monitor the intact molecule and to use 13C-labelled TBBPA as an internal surrogate standard, two features that improve both accuracy and precision of the analyses. Comparison of different acquisition modes in electrospray ionization showed that the lowest detections limit, 3.1 pg TBBPA injected, was obtained in SIM monitoring the molecular ions 542.7/544.7. A fragmentation pathway of TBBPA in LC-ESI-MS is suggested. The only sample clean-up steps required are solvent reduction and filtration of the sample extract. Recoveries were 93% at a 30 ng level and 75% at 3 ng. The new method was tested by analyses of air samples collected at a recycling plant for electronic equipment. The amount of TBBPA found was 13.8 ng/m3 with an RSD of 5.9%. Furthermore, it was found that TBBPA in a standard solution could be partially debrominated, if not carefully protected from light during storage.  相似文献   

3.
《中国化学快报》2023,34(4):107715
Liquid chromatography tandem mass spectrometry (LC-MS/MS) plays an important role in clinical diagnostics. Although LC-MS/MS is superior in terms of accurately quantifying molecules in complex matrices, instrument footprint, operation and maintenance complexity also hinder its expansion as the analytical technique of choice. In this study, a compact LC-MS instrument was developed, in which an assembled liquid chromatograph was coupled with a miniature ion trap mass spectrometer. The overall instrument has a footprint of 69 cm × 31 cm × 31 cm, and it requires no gas supply as well as minimum maintenance. Furthermore, the use of LC-MS is in accord with conventional clinical diagnostic protocols, and the choice of ion trap offers tandem MS performance. The results showed that the use of LC could improve both mixture analysis capability and detection sensitivity of the miniature mass spectrometer. After optimization, feasibility of this instrument in clinical practice was demonstrated by the quantitation of four widely used immunosuppressants in blood samples. Relatively good linearities were obtained, which spanned the reference ranges of effective therapeutic concentrations of each immunosuppressant. Intra-day and inter-day accuracy and precision of analytical method were also assessed. This work showed that a compact LC-MS instrument could be used in clinical diagnosis, either to replace conventional lab-scale instruments or to be used in POCT applications.  相似文献   

4.
C. Giachetti 《Chromatographia》1998,48(5-6):443-449
Summary Low amounts of triethanolamine, collected in ORBO 53 tubes during air sampling, required the development of a very sensitive method for determination. After desorption and silylation reaction with trimethylsilyl imidazole/trimethyl chlorosilane, the derivative was analyzed by gas chromatography-mass spectrometry on an Ultra 2 silica capillary column in single ion monitoring mode (retention time: about 6 min). The method has a detection limit of 1–2 pg with a desorption efficiency of about 81%. Linearity of response was ascertained in the ranges 10–100 ng and 100–1000 ng. Short-term method validation was carried out by intra- and inter-day assays on three amounts for each reference calibration curve. All results satisfied the pre-defined acceptance criteria. In general, the whole procedure was easily performed and was appropriate for our needs. Breakthrough volume was appropriate for our needs. Breakthrough volume was determined on authentic samples and was about 40–60 L, using a flow rate of 1 L·min−1. The amounts of triethanolamine found in the samples ranged from 150 to 250 ng (about 2.5–4.2 μg·m−3).  相似文献   

5.
A sensitive method with liquid chromatography-electrospray ionization mass spectrometry has been developed and validated for the determination of aristololactam-I in rat plasma after oral administration of aristolochic acid-I using finesteride as the internal standard. Chromatographic separation was achieved on a Lichrospher C(18) column using methanol:0.05% acetic acid in water (71:29, v/v) as a mobile phase delivered at a flow rate of 1 mL/min. The assay was linear for aristololactam-I over the range 0.3-300 ng/mL. The analysis of quality control samples demonstrated precision with coefficient of variation less than 20% (n = 5). Absolute recovery of aristololactam-I was 90.4-97.3%. The LC-MS method for the determination of aristololactam-I is sensitive, specific and can be used to investigate the toxicokinetics of aristololactam-I.  相似文献   

6.
A sensitive and selective liquid chromatography-mass spectrometry method has been developed for the simultaneous identification and quantitation of drug substances and metabolites in rat plasma. The method combines on-line turbulent-flow chromatography, high-performance liquid chromatography and mass spectrometry. This combination is considered to be a new approach suitable for fast bio-analysis in drug discovery. Dextromethorphan, and its two metabolites, dextrorphan and 3-methoxymorphinan served as model substances. The analytes present in plasma were collected on a Cyclone column using turbulent-flow chromatography and were subsequently transferred on-line to and focused on an X-Terra MS C8 column. The analytes were eluted by a linear gradient and detected by a fast scanning mass spectrometer. The detector response was quadratic and the dynamic range was estimated to be 0.5-100 ng/ml plasma or 12.5 pg to 2.50 ng injected into the system.  相似文献   

7.
高效液相色谱法测定车内空气中醛酮类羰基化合物   总被引:1,自引:0,他引:1  
采用填充有表面涂渍2,4-二硝基苯肼(DNPH)的硅胶吸附管采集汽车内空气中的醛酮类羰基化合物,经乙腈洗脱定容,洗脱液采用高效液相色谱.紫外检测器(HPLC/UV)分析检测.该方法平行样品的相对标准偏差<10%,回收率为95%~105%,检出限为1.6~7.1μg/m3.方法适用于车内环境中醛酮类羰基化合物的分析测试.  相似文献   

8.
Liquid chromatography–mass spectrometry (LC–MS) is a powerful tool for analysis of drugs and their metabolites. We used a column-switching system in combination with atmospheric pressure chemical ionization LC–MS (LC–APCI–MS) for the determination of theophylline and its metabolites in biological samples. The separation was carried out on a reversed-phase column using methanol–20 mM ammonium acetate as a mobile phase at a flow-rate of 1 ml/min in 30 min. In the mass spectrum, the molecular ions of these drugs and metabolites were clearly observed as base peaks. This method is sufficiently sensitive and accurate for the pharmacokinetic studies of these drugs.  相似文献   

9.
Liquid chromatography-mass spectrometry (LC-MS) and coupled column chromatography can be used to overcome problems likely to occur in direct separation and determination of drug enantiomers in biological samples. This is exemplified here with the direct separation and determination of terbutaline in human plasma at the nmol/l level. A beta-cyclodextrin column with an aqueous mobile phase was used for chiral separation. For coupled column chromatography, the concentration of each enantiomer was calculated from the enantiomeric area ratio and the racemate concentration. A deuterium-labelled internal standard was used in the LC-MS experiments.  相似文献   

10.
A method for the detection and quantification of the microcystins (MCs)-MC-LR, MC-RR and MC-YR-in biological samples by matrix solid-phase dispersion (MSPD) has been developed. The optimum extraction conditions were 500 mg of liver or kidney, C18 bonded silica as dispersant, and a mixture methanol-water (70:30) as eluent. The MCs were determined by liquid chromatography electrospray mass spectrometry (LC/ES/MS). Recoveries of biological extracts at three different spiked levels (1-10 mg kg(-1)) ranged from 40.5 to 87.0% in liver, and from 52.5 to 74.5 in kidney. R.S.D.s were < 15.6% and < 10.6%, respectively. The detection and quantification limits were 0.05 and 0.5 mg kg(-1), for all MCs. The method was applied to MCs detection in liver and kidney of rat previously injected i.p. with MC-LR. Results showed the presence of MC-LR in the liver of the animals injected with the highest dose.  相似文献   

11.
A high-performance liquid chromatographic (HPLC) method was developed for the separation and determination of individual (C10-C13) linear alkylbenzene sulfonates (LAS). New sets of conditions have been established for routine analysis of individual chemical forms of four LAS surfactants, i.e. C10-C13 LAS. Under a condition set using a mobile phase containing 1.5 mM ammonium acetate in methanol/water 80:20 (v/v) mixture, detection limits obtained were in the range 1.5 ppb (for C10 LAS) to 11.5 ppb (for C13 LAS). This offers the advantages of significant improvement in resolution, short separation time and using less amount of common salt under isocratic condition. In addition, the use of simple mobile phase containing a simple low amount of salt cannot deposit at the entrance of mass spectrometric detector. The method is applicable to the simultaneous determination of LAS surfactants in various water samples. LAS surfactants presented in these samples were also successfully confirmed by using electrospray mass spectrometry.  相似文献   

12.
A procedure for coating in situ silica gel in prepacked cartridges with 2,4-dinitrophenylhydrazine (DNPH) acidified with hydrochloric acid is described. The coated cartridge was compared with a validated DNPH impinger method for sampling organic carbonyl compounds (aldehydes and ketones) in diluted automotive exhaust emissions and in ambient air for subsequent analysis of the DNPH derivatives by high performance liquid chromatography. Qualitative and quantitative data are presented that show that the two sampling devices are equivalent. The coated cartridge is ideal for long-term sampling of carbonyls at sub to low parts-per-billion level in ambient air or for short-term sampling of carbonyls at low ppb to parts-per-million level in diluted automotive exhaust emissions. An unknown degradation product of acrolein has been tentatively identified as x-acrolein. The disappearance of acrolein in the analytical sample matrix correlates quantitatively almost on a mole for mole basis with the growth of x-acrolein. The sum of the concentration of acrolein and x-acrolein appears to be invariant with time.  相似文献   

13.
A method for the simultaneous determination of two biocidal quaternary ammonium compounds; didecyldimethylammonium chloride (didecyldimethyl quat) and dodecylbenzyldimethylammonium chloride (benzyl quat), in seawater by solid phase extraction (SPE) followed by liquid chromatography-mass spectrometry (LC-MS) was developed. The optimised procedure utilised off-line extraction of the analytes from seawater using polymeric (Strata-X) SPE cartridges. Recoveries ranged from 80 to 105%, with detection limits at the low parts-per-trillion (ng/l) level for both analytes. To demonstrate sensitivity, environmental concentrations were measured at three different locations along the North East coast of England with measured values in the range 120-270ng/l.  相似文献   

14.
A new analytical method, using gas chromatography-mass spectrometry (GC/MS) and liquid chromatography-mass spectrometry (LC/MS) techniques, was developed for the determination in packaged food beverages of five ink photoinitiator residues: 2-isopropylthioxanthone (ITX), benzophenone, 2-ethylhexyl-4-dimethylaminobenzoate (EHDAB), 1-hydroxycyclohexyl-1-phenyl ketone (IRGACURE 184) and ethyl-4-dimethylaminobenzoate (EDAB). Samples were extracted from selected beverages (milk, fruit juices and wine) and relative packagings, using n-hexane and dichloromethane, respectively, purified on solid-phase extraction (SPE) silica gel cartridges, and then analyzed in GC/MS and LC/MS. The recovery percentages, obtained spiking the beverage samples at concentrations of 4 and 10 microgl(-1) with a standard mixture of photoinitiators, were in the range 42-108% (milk), 50-84% (wine), and 48-109% (fruit juices). The repeatability of the method was assessed in all cases by the % of correlation value, that was lower than 19%. The lowest limits of detection (LODs) and limits of quantification (LOQs), obtained using GC/MS, were in the range 0.2-1 and 1-5 microgl(-1), respectively. The method was applied to the analysis of forty packaged food beverages (milk, fruit juices and wine samples). The most significant contamination was that of benzophenone, found in all samples in a concentration range of 5-217mugl(-1). Its presence was confirmed by an LC/Atmospheric-Pressure PhotoIonization (APPI)/MS/MS analysis. The photoinitiator (EHDAB) was found in eleven out of forty beverages in a concentration range of 0.13-0.8 microgl(-1). Less important was the ITX contamination, found in three out of forty samples in a range 0.2-0.24 microgl(-1). The work proposes a new method to analyze ink photoinitiator residues in polycoupled carton packaging and in contained food beverages.  相似文献   

15.
A sensitive and simultaneous liquid chromatographic-mass spectrometric (LC/MS) method for the determination of current four HIV protease inhibitors (PIs), indinavir (IDV), saquinavir (SQV), nelfinavir (NFV) and amprenavir (APV) in rat plasma and liver dialysate by a microdialysis method was described. An isocratic LC/MS method in combination with atmospheric pressure chemical ionization was developed for the determination of these four PIs in biological samples in the same run. The analytes including an internal standard were extracted from 100 microL of plasma or 150 microL of liver dialysate samples by salting-out with 100 microL of ice-cold 2 M K(3)PO(4) followed by ether extraction. The separation of analytes was carried out on a reversed-phase semi-micro column using 50% of acetonitrile containing 1% acetic acid as mobile phase at a flow rate of 0.2mL/min(-1). The separation was completed within 5 min. Precision, recovery and limits of detection indicated that the method was suitable for the quantitative determination of these PIs in rat plasma or liver dialysate. This simple, sensitive and highly specific LC/MS method is suitable for pharmacokinetic studies and therapeutic drug monitoring in AIDS patients who receive double protease therapy.  相似文献   

16.
Mehmet Akyüz 《Talanta》2007,71(1):486-492
A gas chromatography-mass spectrometry (GC-MS) method has been proposed for the simultaneous determination of aliphatic and aromatic amines in indoor and outdoor air samples. The method includes pre-concentration of the compounds by percolating the air samples through the acidic solution, ion-pair extraction with bis-2-ethylhexylphosphate (BEHPA), derivatisation of compounds with isobutyl chloroformate (IBCF) and their GC-MS analysis. Aliphatic and aromatic amines were isolated from aqueous samples using BEHPA as ion-pair reagent and derivatised with IBCF for their chromatographic analysis. Aliphatic and aromatic amines were then analysed with GC-MS in both electron impact (EI) and positive and negative ion chemical ionisation (PNICI) mode as their isobutyloxycarbonyl (isoBOC) derivatives. The obtained recoveries ranged from 75.6 to 96.8% and the precision of this method, as indicated by the relative standard deviations (R.S.D.) was within the range of 1.0-4.4%. The detection limits obtained from calculations by using GC-MS results based on S/N: 3 were within the range of 0.08-0.01 ng/m3.  相似文献   

17.
Identification and quantitation of trace amounts of trenbolone in bovine tissue by capillary gas chromatography-mass spectrometry-selected-ion monitoring (GC-MS-SIM) has been developed. Three-phase liquid-liquid extraction using a mixture of water-acetonitrile-dichloromethane-hexane was utilized for the sample extraction from tissue. Target compounds were extracted from the tissue into the acetonitrile layer. The residue from this extraction was then subjected to solid-phase extraction by C18 and silica gel disposable cartridges using methanol-water and benzene-acetone as eluents. To overcome extensive matrix interferences, preparative reversed-phase high-performance liquid chromatographic separation was used with an octadecyl-bonded column using methanol-water as mobile phase for sample clean-up prior to GC-MS analysis. A structural analogue of trenbolone, 19-nortestosterone, was chosen as the internal standard for quantitation by GC-MS. The sample was co-injected with N,O-bis (trimethylsilyl) trifluoroacetamide-1-(trimethylsilyl) imidazole (95:5, v/v) for flash heater derivation. Identification and quantitation were simultaneously carried out by SIM of characteristic ions of the trimethylsilyl derivatives of trenbolone and 19-nortestosterone. The limit of detection for trenbolone and epitrenbolone was 0.5 ppb in muscle and liver tissue. A comparison of sensitivity and specificity between GC-MS under electron ionization in addition to positive- and negative-ion chemical ionization conditions using methane reagent gas is also discussed.  相似文献   

18.
With the renovation of Boston Harbor's Deer Island wastewater treatment plant and the extension of its diffuser pipes 15 km further into Massachusetts Bay, there arose the question whether the increased load of its secondary-treated wastewater contained significant amounts of phenolic endocrine disrupting chemicals (EDCs). Sampling from an oceanographic research vessel during the summers of 2003 and 2004 allowed for a unique opportunity to obtain clam, zooplankton, and bottom sediment samples. The samples were prepared by enhanced organic-solvent microwave digestion, followed by solid-phase extraction (SPE), derivatization and then analyzed by gas chromatography-mass spectrometry (GC-MS) or left un-derivatized and analyzed by LC-UV and liquid chromatography-mass spectrometry (LC-MS). The marine samples, especially parts of the clams, zooplankton and certain bottom sediments were found to contain primarily bisphenol A (BPA) at concentrations of 1-30 ng/g.  相似文献   

19.
20.
A method was developed for the determination of benzothiazoles from municipal wastewater, which may originate from their use as corrosion inhibitors, vulcanization accelerators or fungicides. Extraction is performed by SPE using a polymeric sorbent, followed by LC-MS analysis with electrospray ionization. Due to the diversity of the analytes, two LC-MS runs are required: 2-aminobenzothiazole, benzothiazole and 2-methylthiobenzothiazole are detected in the positive ion mode, while benzothiazole-2-sulfonic acid (BTSA), 2-mercaptobenzothiazole and 2-hydroxybenzothiazole are determined in the negative ion mode. Limits of quantification range from 20 to 200 ng/L in treated wastewater. Reliable quantification with R.S.D.s below 25% is achieved by standard addition in a limited number of samples of each sample series. A significant reduction of matrix effects in positive electrospray ionization is achieved by reducing the flow directed into the ESI-interface. When applied to untreated municipal wastewater most analytes were found at concentrations in the high ng/L- to low microg/L-range with the most polar BTSA being the dominant compound of this class. Removal of benzothiazoles in biological wastewater treatment appears to be limited.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号