 共查询到20条相似文献,搜索用时 31 毫秒
1.
Mass selective axial ejection of ions from linear quadrupoles with added octopole fields is described. Quadrupoles with 2.0% and 2.6% added octopole fields have been tested and compared with a conventional quadrupole. The effects of trapping ions at different q values, excitation voltage, scan direction, balanced and unbalanced rf voltages on the rods, and dc applied between the rods have been investigated. The highest scan speeds and best resolution are obtained with resonant excitation and ejection at high q (q = 0.8). With axial ejection, the quadrupole with a 2.0% added octopole field provides mass resolution and ejection efficiencies similar to a conventional rod set. Quadrupole, dipole, and simultaneous dipole-dipole excitation between the x and y rod pairs were compared, and no advantage was found with quadrupole or dipole-dipole excitation. The effects of scan speed were investigated and a resolution at half height of about 1600 is possible at scans speed up to 5000 Th/s.  相似文献   

2.
Modeling and experimental studies of quadrupole excitation of ions in linear quadrupole traps with added octopole fields are described. An approximate solution to the equations of motion of ions trapped in a quadrupole with added octopole and dodecapole fields, with quadrupole excitation and damping is given. The solutions give the steady-state or stationary amplitudes of oscillation with different excitation frequencies. Trajectory calculations of the oscillation amplitudes are also presented. The calculations show that there can be large changes in the amplitude of ion oscillation with small changes in excitation frequency, on both the low and high-frequency sides of a resonance. Results of experiments with quadrupole excitation of reserpine ions in linear quadrupole traps with 2.0%, 2.6%, and 4.0% added octopole fields are given. It is found that as the excitation frequency is changed, two resonances are generally observed, which are attributed to the motion in the x and y directions. The two resonances can have quite different intensities. Sudden jumps or sharp sided resonances are not observed, although in some cases asymmetric resonances are seen. The calculated frequency differences between the two resonances are in approximate agreement with the experiments.  相似文献   

3.
Linear quadrupoles with added hexapole fields   总被引:1,自引:0,他引:1  
Linear quadrupoles with added hexapole fields are described. The shifts in ion oscillation frequency caused by the addition of a hexapole field are calculated within the effective potential model. Methods to construct linear quadrupoles with added hexapole fields with exact electrode geometries and with round rods are discussed. A quadrupole with added hexapole field can be constructed with round rods by rotating two rods (say the y rods) towards an x rod. Computer simulations are used to investigate the possibility of mass analysis with quadrupoles with added hexapole fields. We find that a quadrupole with an added hexapole field in the range 2-12% can provide mass analysis provided the dc is applied with the correct polarity and value. When a rod set is constructed with round rods, other multipoles in the potential degrade the peak shape, resolution and transmission. The largest of these after the quadrupole and hexapole are a dipole and octopole term. With round rod sets, the peak shape can be improved by using different diameters for the x and y rod pairs to minimize the octopole term in the potential and by injecting ions at the field center where the dipole term is zero. Calculations of the boundaries of the stability diagram for this case show the boundaries move out, relative to those of a pure quadrupole field, but remain sharp.  相似文献   

4.
Quadrupole mass filters with octopole fields   总被引:1,自引:0,他引:1  
The performance of quadrupole mass filters with added octopole fields in the range 2.0-4.0% has been investigated. The added fields are much greater than those normally added to conventional rod sets by mechanical tolerances or construction errors. Quadrupole rod sets with added octopole fields were constructed with round rods by making one pair of rods greater in diameter than the other pair. For positive ions, resolution at half height of only about 200 is possible if the negative direct current (dc) output of the quadrupole power supply is connected to the smaller rods. If the positive dc output of the quadrupole power supply is connected to the smaller rods, the resolution improves dramatically; a resolution at half height of 5800 has been observed with a rod set with 2.6% added octopole field. For negative ions the best resolution is obtained with the polarity of the dc reversed, i.e. with the negative dc applied to the smaller rods. These findings are unexpected in view of the literature that argues that to obtain high mass resolution with quadrupole mass filters, higher order multipoles must be kept as small as possible. Numerical simulations of peak shapes agree qualitatively with experiments. Simulation of the boundaries of the first stability region for positive ions shows that when the positive dc is applied to the smaller rods, the addition of a 2.0% octopole field causes the boundaries to shift slightly but the boundaries are well defined, and the tip of the stability region remains sharp. When the positive dc is applied to the larger rods, the boundaries of the stability region move out and become diffuse. For instruments that require a rod set that can be used both as a linear trap and a mass filter, these rod sets may offer improved trap performance while still being capable of providing conventional mass analysis.  相似文献   

5.
Mass analysis with linear quadrupole mass filters is possible by forming "islands" in the stability diagram with auxiliary quadrupole excitation. In this work, computer simulations are used to calculate stability boundaries, island positions, and peak shapes and ion transmission for mass analysis with linear quadrupole mass filters that have added octopole fields of about 2 to 4%. Rod sets with exact geometries that have quadrupole and octopole fields only in the potential, and round rod sets, with multipoles up to N = 10 (the twenty pole term) included in the calculations, show the same stability boundaries, island positions, and peak shapes. With the DC voltage applied to the rods so that the Mathieu parameter a < 0, conventional mass analysis is possible without the use of an island. With the DC polarity reversed so that a > 0, the resolution and transmission are poor preventing conventional mass analysis. In principle, mass analysis in an island is possible with operation at either of two tips. Provided the correct island tip is chosen for mass analysis, peak shapes comparable to those with a > 0 and no excitation are possible, both with a > 0 and with a < 0. In the latter case, the use of an island of stability allows mass analysis when the added octopole otherwise prevents conventional mass analysis.  相似文献   

6.
Two methods of adding relatively small octopole fields to the main quadrupole field of quadrupoles and linear ion traps with cylindrical rods are investigated. The first, 'stretching' the quadrupole by moving two rods out from the axis, produces a combination of higher order fields with similar magnitudes in which the octopole field is not necessarily the greatest. The quadrupole field strength is changed significantly and a large potential appears on the axis. The second method uses rod pairs of different diameters. It adds octopole components of up to several percent while all other higher order fields remain small. An axis potential is also added, but it is only a few percent of the radio-frequency (RF) voltage and approximately equal to the strength of the octopole field. The axis potential can be removed by moving the larger rod pair out from the axis or applying unbalanced RF to the electrodes.  相似文献   

7.
We describe a new mass selective ejection method from a linear ion trap, which we call axial resonant excitation (AREX). A set of vane lenses are inserted between each quadrupole rod to produce electrostatic potential that is approximately harmonic along the central axis of the quadrupole field. After ions with specific m/z are resonantly oscillated in the axial direction, the ions are mass selectively ejected in the axial direction. At a high scan rate of 11 Th/ms, AREX achieved a high ejection efficiency of more than 60%, which is more than three times higher than a conventional mass selective axial ejection method from a linear trap using fringing field.  相似文献   

8.
Collision induced dissociation (CID) in a quadrupole ion trap mass spectrometer using the conventional 30 ms activation time is compared with high amplitude short time excitation (HASTE) CID using 2 ms and 1 ms activation times. As a result of the shorter activation times, dissociation of the parent ions using the HASTE CID technique requires resonance excitation voltages greater than conventional CID. After activation, the rf trapping voltage is lowered to allow product ions below the low mass cut-off to be trapped. The HASTE CID spectra are notably different from those obtained using conventional CID and can include product ions below the low mass cut-off for the parent ions of interest. The MS/MS efficiencies of HASTE CID are not significantly different when compared with the conventional 30 ms CID. Similar results were obtained with a two-dimensional (linear) ion trap and a three-dimensional ion trap.  相似文献   

9.
We describe experimental investigations of mass analysis using an island of stability with a linear quadrupole with a 2.0% added octopole field. The island is formed by auxiliary quadrupole excitation. The experiments confirm the results of previous computer simulations (Konenkov et al., J. Am. Soc. Mass Spectrom. 2007; 18: 826-834). With the resolving direct current (dc) applied to the quadrupole so that the Mathieu parameter a > 0, conventional mass analysis with applied radio-frequency (rf) and dc and no auxiliary excitation is possible. In this case, use of an island of stability yields similar peak shape and resolution. However, with the polarity of the resolving dc reversed, so that a < 0, only very low resolution can be obtained; the added octopole prevents conventional mass analysis. By using a stability island when a < 0, the resolution is substantially improved. In this case the use of an island allows mass analysis under conditions where the added octopole field severely degrades conventional analysis. The experiments also confirm the position of the island predicted by the simulations.  相似文献   

10.
A theoretical method, the harmonic balance method, was introduced to study the coupling effects of hexapole and octopole fields on ion motion in a quadrupole ion trap. Ion motion characteristics, such as ion motion center displacement, ion secular frequency shift, nonlinear resonance curve and buffer gas damping effects, have been studied with the presence of both hexapole and octopole fields. It is found that hexapole fields have bigger impacts on ion motion center displacement, while octopole fields dominate ion secular frequency shift. Furthermore, the nonlinear features originated from hexapole and octopole fields could enhance or cancel each other, which provide us more space in a practical ion trap design process. As an example, an ion trap with improved performance was designed using a specific combination of hexapole and octopole fields. In this ion trap, a hexapole field was used to achieve efficient ion directional ejection, while an octopole field was added to correct the chemical mass shift and resolution degradation introduced by the hexapole field. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

11.
It is well known that superimposition of some positive octopole field will benefit the performance of ion trap mass analyzer. In the radial‐ejection linear ion trap (LIT), adding some octopole field component to the main quadrupole field is usually accomplished by stretching the ejection rod pair. In this study, the effect of octopole potential and some other higher order potential on the performance of LIT mass analyzer is investigated. A simple and effective method, which is to add some octopole component by building a LIT with a pair of rectangular electrodes and a pair of semi‐circular electrodes, is reported. Its properties were studied by numerical simulations and experiments. The results showed that a certain amount of positive octopole component could be produced by simply adjusting the position and width of the rectangular electrodes. A resolution of over 1200 at m/z 609 (~1600 Da/s) was observed in this type of LIT. They also performed tandem mass spectrometry well. The device with optimum geometry for ion ejection from rectangular electrodes provided comparable performance to that for ion ejection from semi‐circular electrodes. This type of LIT design is easy for fabrication and assembly. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

12.
A new collision-induced dissociation (CID) technique based on broadband tailored noise waveform (TNW) excitation of ions stored in a linear ion trap has been developed. In comparison with the conventional sustained off-resonance irradiation (SORI) CID method commonly used in Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS), this MS/MS technique increases throughput by eliminating the long pump-down delay associated with gas introduction into the high vacuum ICR cell region. In addition, the TNW-CID method speeds spectrum acquisition since it does not require Fourier transformation, calculation of resonant frequencies and generation of the excitation waveforms. We demonstrate TNW-CID coupled with on-line capillary reverse-phase liquid chromatography separations for the identification of peptides. The experimental results are compared with data obtained using conventional quadrupole ion trap MS/MS and SORI-CID MS/MS in an ICR cell.  相似文献   

13.
Investigations using ion trap devices for analytical atomic spectroscopy purposes have focused on the use of an inductively coupled plasma (ICP) ion source with ion trap mass spectrometric (ITMS) detection. Initial studies were conducted with an instrument assembled by simply appending an ion trap as the detector to a fairly conventional ICP/MS instrument, i.e. leaving an intermediate linear quadrupole between the plasma source and the ion trap. The principal advantages found with this system include the destruction of nearly all problematic and typical ICP/MS polyatomic ions (e.g., ArH(+), ArO(+), ArCl(+), Ar(2)(+), etc) and a dramatic reduction of the primary plasma source ion, Ar(+). These results prompted the development of a second-generation plasma source ion trap instrument in which direct coupling of the ICP and ion trap has been effected (i.e. no intermediate linear quadrupole); the same performance benefits have been largely preserved. Initial operation of this instrument is described, characterized, and compared to the originally described ICP/ITMS and conventional ICP/MS systems. In addition, experiments aimed at improving ICP/ITMS sensitivity and selectivity using broadband resonance excitation techniques are described. Finally, the potential for laser optical detection of trapped ions for analytical purposes is speculated upon.  相似文献   

14.
Ion motion with auxiliary dipole excitation and collisional damping in a linear radiofrequency quadrupole ion trap incorporating small amounts of even higher order multipoles is studied analytically. The ion motion is modeled in a pseudopotential that is mostly quadratic with small amounts of higher spatial harmonics. Ion motion along x and y axes is characterized by two uncoupled forced and damped anharmonic oscillator equations. A multiple time scales method is used to solve the equations of motion of ions with a first order perturbation correction. Analytical relations between the oscillation amplitudes at steady state (the stationary amplitudes) and excitation frequency are calculated. The frequency response curves show that in some cases bistable behavior might be obtained, i.e., there are two stable stationary amplitudes for a given excitation frequency.  相似文献   

15.
Investigations using ion trap devices for analytical atomic spectroscopy purposes have focused on the use of an inductively coupled plasma (ICP) ion source with ion trap mass spectrometric (ITMS) detection. Initial studies were conducted with an instrument assembled by simply appending an ion trap as the detector to a fairly conventional ICP/MS instrument, i.e. leaving an intermediate linear quadrupole between the plasma source and the ion trap. The principal advantages found with this system include the destruction of nearly all problematic and typical ICP/MS polyatomic ions (e.g., ArH+, ArO+, ArCl+, Ar2+, etc) and a dramatic reduction of the primary plasma source ion, Ar+. These results prompted the development of a second-generation plasma source ion trap instrument in which direct coupling of the ICP and ion trap has been effected (i.e. no intermediate linear quadrupole); the same performance benefits have been largely preserved. Initial operation of this instrument is described, characterized, and compared to the originally described ICP/ITMS and conventional ICP/MS systems. In addition, experiments aimed at improving ICP/ITMS sensitivity and selectivity using broadband resonance excitation techniques are described. Finally, the potential for laser optical detection of trapped ions for analytical purposes is speculated upon.  相似文献   

16.
In this paper, a modified version of the homotopy perturbation method, which has been applied to non-linear oscillations by V. Marinca, is used for calculation of axial secular frequencies of a non-linear ion trap with hexapole and octopole superpositions. The axial equation of ion motion in a rapidly oscillating field of an ion trap can be transformed to a Duffing-like equation. With only octopole superposition the resulted non-linear equation is symmetric; however, in the presence of hexapole and octopole superpositions, it is asymmetric. This modified homotopy perturbation method is used for solving the resulting non-linear equations. As a result, the ion secular frequencies as a function of non-linear field parameters are obtained. The calculated secular frequencies are compared with the results of the homotopy perturbation method and the exact results. With only hexapole superposition, the results of this paper and the homotopy perturbation method are the same and with hexapole and octopole superpositions, the results of this paper are much more closer to the exact results compared with the results of the homotopy perturbation method.  相似文献   

17.
The use of a new hybrid quadrupole/linear ion trap known as the Q TRAP offers unique benefits as a LC-MS-MS detector for both small and large molecule analyses. The instrument combines the capabilities of a triple quadrupole mass spectrometer and ion trap technology on a single platform. Product ion scans are conducted in a hybrid fashion with the fragmentation step accomplished via acceleration into the collision cell followed by trapping and mass analysis in the Q3 linear ion trap. This results in triple quadrupole fragmentation patterns with no inherent low molecular mass cutoff. In-trap fragmentation is also possible in order to provide triple MS (MS3) capabilities. There are also several scan modes that are not possible on conventional instruments that enable identification of analytes within complex biological matrixes for subsequent high sensitivity product ion scans. This report will describe the new hybrid instrument and the principles of operation, and also provide examples of the unique scan modes and capabilities of the Q TRAP for LC-MS-MS detection in metabolism identification.  相似文献   

18.
Technological advancements including an open-cylindrical Penning trap with capacitively coupled ICR cell, selective ion accumulation with a resolving quadrupole, and a voltage gradient used during ion extraction from an octopole ion trap, have individually improved dynamic range and sensitivity in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (FT-ICR MS). Documented here is a new instrument utilizing these technologies toward the robust detection and fragmentation of biomolecules >10 kDa. Up to 55-fold enhancement in ion population by selective ion accumulation combined with 10- to 20- fold signal-to-noise improvement by application of a DC voltage gradient to an accumulation octopole during the ion transfer event offers improved signal-to-noise (or speed) of MS/MS experiments, for proteins from Methanococcus jannaschii and Saccharomyces cerevisiae whole cell lysates. After external quadrupole filtering with a 40 m/z window, three proteins were fragmented (and identified) in parallel from the database of Methanococcus jannaschii. Electron capture dissociation (ECD) of an intact yeast protein provides extensive sequence information resulting in a high degree of localization for an N-terminal acetylation. Hybrid fragmentation, infrared multiphoton dissociation (IRMPD) followed by low energy electrons (ECD), with the electron source located laterally off the z-axis and external to the magnet bore, presents a strategy for identification of proteins by means of the sequence tag approach. Automated implementation of diverse MS(n) approaches in a Q-FTMS instrument promises to help realize "top-down" proteomics in the future.  相似文献   

19.
Fundamental aspects are presented of a two-temperature moment theory for quadrupole ion traps developed via transformation of the Boltzmann equation. Solutions of the moment equations correspond to changes in the ensemble average for any function of ion velocity, because the Boltzmann equation reflects changes to an ion distribution as a whole. The function of primary interest in this paper is the ion effective temperature and its behavior during ion storage and resonance excitation. Calculations suggest that increases in ion effective temperature during resonance excitation are due primarily to power absorption from the main RF trapping field rather than from the dipolar excitation signal. The dipolar excitation signal apparently serves mainly to move ions into regions of the ion trap where the RF electric field, and thus ion RF heating, is greater than near the trap center. Both ideal and non-ideal ion trap configurations are accounted for in the moment equations by incorporating parameterized variables a and q , which are modified versions of the commonly used forms for the DC and AC ring voltages, and b and d , which are new forms that account for the voltages applied to the endcaps. Besides extending the applicability of the moment equations to non-ideal quadrupole ion traps, the modified versions of the parameterized variables can have additional utility. Calculation of the spatial dependence of ion secular oscillation frequencies is demonstrated as an example.  相似文献   

20.
Methods to reduce mass shifts caused by space charge with mass‐selective axial ejection from a linear quadrupole ion trap are investigated. For axial ejection, dipole excitation is applied to excite ions at q ≈ 0.85. The trapping radiofrequency (rf) voltage is scanned to bring ions of different m/z values into resonance for excitation. In the fringing field at the quadrupole exit, excited ions gain axial kinetic energy, overcoming the trapping potential, and are ejected from the trap. Space charge causes the frequencies of ion oscillation to decrease. Thus, greater rf voltages are required to bring ions into resonance for excitation and ejection, and the ions shift to higher apparent masses in a mass spectrum. At the same time, the peaks broaden, lowering resolution. The effects of injection q value, ejection q value, excitation amplitude, quadrupole dc voltages applied to the electrodes, applying an rf voltage to the exit lens, and scan speed, on mass shifts have been studied experimentally. Most experiments were done with only ions of protonated reserpine (m/z 609.3 and its isotopic peaks) in the trap. Some experiments were done with ions of protonated reserpine and ions of m/z 622 in the trap. In general, the mass shifts are reduced with higher ejection q values, higher excitation amplitudes, with quadrupole dc applied, and at higher scan speeds. The application of quadrupole dc appears to increase the ion cloud temperature, which lowers mass shifts. Thus, a proper choice of operating conditions can reduce, but not eliminate, mass shifts caused by space charge. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   