首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary Retention characteristics of metoprolol have been studied in reversed phase mode on RP2, RP8 and CN columns. The plots of retention time as a function of the acetonitrile content and of the ionic strength of the mobile phase permitted the choice of the best conditions to separate metoprolol from plasma components by switching of these three types of columns.Human plasma (0.5–1 ml) diluted with water is first injected on a RP2 column (25–40 m particle diameter, prepared by dry packing) and rinsed with water. The sample is then back eluted with acetonitrile-0.022 M acetate buffer (7525, v:v) and switched to a CN column (10 cm long, 5 m particle diameter). The heart cut of the eluate is selected and loaded on a RP8 analytical column (25 cm long, 5 m particle diameter) with acetonitrile-0.088 M acetate buffer (7525, v:v) as mobile phase.Auto-sampler and switching valves are actuated automatically by a computing integrator based on a fixed time schedule. The duration of one cycle is about 30 min, but the last analytical step is about 15 min and represents the time interval between two injections. Metoprolol, its alpha-hydroxy metabolite and the internal standard are detected by fluorescence (ex= 225 nm; em > 320 nm).Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

2.
Ramoplanin is a novel glycolipodepsipeptide antibiotic, currently undergoing clinical trials. This method describes the determination of ramoplanin by direct injection of human urine into a coupled-column liquid chromatographic system. An internal-surface reversed-phase column has been used for on-line sample clean-up and enrichment. Analytical separation of ramoplanin and MDL 62,456 used as internal standard, has been achieved on a ABZ+ reversed-phase column with ammonium acetate buffer-acetonitrile-methanol according to a gradient profile. Analytes were detected by their UV absorbance at 270 nm. The limit of quantitation was 0.1 microgram/ml urine and the limit of detection was found to be 0.035 microgram/ml, corresponding to 13.7 pmol/ml. Linearity was determined in the range 0.1-2 micrograms/ml. Precision (relative standard deviation) ranged from 0.71 to 8.75% and the accuracy from -9.9 to 11.6%. Different human sources were tested and no interference between analytes and urine constituents was observed. The method is simple and rapid, requiring a total analysis time of 35 min per sample and reaching greater selectivity and accuracy than microbiological assays.  相似文献   

3.
Melagatran is an active thrombin inhibitor showing oral and parenteral bioavailability for antithrombotic therapy. A simple and convenient liquid chromatographic method has been developed and applied to the analysis of melagatran in rabbit plasma. The clean-up and separation of the sample solutions were performed by automated on-line column switching HPLC. The method validation shows the suitability of the column switching liquid chromatographic system for the quantitation of melagatran in biological fluids.  相似文献   

4.
5.
A fully automated high-performance liquid chromatographic column-switching system is presented for the determination of cyclosporin A in whole blood. After blood proteins were precipitated with acetonitrile, the supernatant was automatically loaded on to a cyanopropyl column for initial separation, and then the fraction containing cyclosporin A was loaded on to a trimethylsilica column for final separation and quantitation. Cyclosporin A was detected by ultraviolet absorption at 205 nm. The minimum detectable concentration of cyclosporin A was 5 ng/ml in 100 microliter of blood. The coefficient of variation of the method was 1.755, 1.748 and 0.655% in whole blood when spiked at the 170, 425 and 850 ng/ml levels, respectively. One assay was completed in 15 min.  相似文献   

6.
An automated high-performance liquid chromatographic assay for the determination of an aldosterone antagonist (I) is described using column switching for direct injection of urine samples. After dilution with buffered internal standard solution, the sample was injected onto a clean-up column (17 X 4.6 mm I.D.), dry-packed with C18 reversed-phase material (particle size 30 micron). Polar urine components were removed by flushing the clean-up column with water. Retained substances, including I and the internal standard, were desorbed by backflush elution onto a 5-micron ODS-silica analytical column (125 X 4 mm I.D.), separated with water-methanol-tetrahydrofuran, and detected at 295 nm. After backflushing the analytical column and re-equilibrating the clean-up column, the system was ready for the next injection. The limit of quantification was ca. 100 ng/ml, using a 100-microliter specimen of diluted urine. The mean inter-assay precision of the method up to 25.6 micrograms/ml was 2%. Practicability and accuracy of the new method were demonstrated by the application to excretion studies performed with human volunteers.  相似文献   

7.
8.
9.
A highly sensitive method for the determination of myoglobin in serum is described, based on high-performance size-exclusion chromatography with chemiluminescence detection. Serum proteins are separated according to their molecular masses on columns packed with TSK-SW gel and those containing haem are detected selectively by post-column chemiluminescence reaction with luminol using a conventional fluorimetric detector. The method is rapid (30 min) and sufficiently sensitive for the diagnosis of myocardial infarction. The minimum detectable myoglobin concentration is 10 ng/ml.  相似文献   

10.
A sensitive column switching HPLC-fluorescence detection for determination of bisphenol A (BPA) in rat brain by coupling with microdialysis was developed. A microdialysis probe was inserted into the hypothalamus of rat brain and an artificial cerebrospinal fluid was used for perfusion. BPA in brain dialysate was subjected to a fluorescent derivatization with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride (DIB-Cl), and the excess reagent was removed by a column-switching technique. Separation was carried out on two ODS semimicro-columns with the mobile phase of acetonitrile-H(2)O-methanol-tetrahydrofuran (55:10:35:2.5, v/v) and acetonitrile-0.1 M acetate buffer (pH 3.0)-methanol (35:10:55, v/v) at a flow rate of 0.10 and 0.15 mL/min for a precolumn and a separation column, respectively. Fluorescence intensity was monitored at 475 nm with excitation of 350 nm. BPA could be sensitively detected at 0.3 ppb in 60 micro L brain microdialysate at a signal-to-noise ratio of 3. By the proposed method, concentrations of BPA in rat brain and plasma were monitored for 8 h after single i.v. or oral administration. It is proved that BPA is capable of penetrating the blood-brain barrier. The ratio of the area under the concentration-time curve of BPA in rat brain to that in blood was estimated to be about 3.0-3.8%.  相似文献   

11.
12.
13.
14.
Analytical procedures have been investigated for the separation, detection, identification and quantitation of some metabolites of N-benzyl-4-substituted anilines. Techniques based on gas-liquid chromatography were investigated and found to be unsatisfactory. By the use of reversed-phase high-performance liquid chromatography with gradient and ion-pairing techniques, methods were devised for the simultaneous analyses of a variety of metabolites. The method involves minimum sample work-up (acetonitrile precipitation) and allows easy and prompt analysis in biological media avoiding undue decomposition of unstable metabolites.  相似文献   

15.
16.
R K Harle  T Cowen 《The Analyst》1978,103(1226):492-496
  相似文献   

17.
A high-performance liquid chromatographic method was developed for monitoring the serum concentration of streptomycin. The method includes clean-up using a Sep-Pak C18 cartridge and quantitation using dihydrostreptomycin as an internal standard. Streptomycin and dihydrostreptomycin were separated by reversed-phase ion-pair chromatography on LiChrosorb RP-18 and detected by UV absorption (195 nm). The calibration graph of serum streptomycin concentration was linear over the range 5-50 micrograms/ml. Streptomycin was added to serum at the level of 20.0 micrograms/ml and its concentration was determined to be 18.9 micrograms/ml with a coefficient of variation of 2.07% (n = 5). The clinical application of this method was confirmed by comparison with fluorescence polarization immunoassay.  相似文献   

18.
A sensitive high-performance liquid chromatographic method for a routine assay of nadolol in serum is described. Serum samples spiked with atenolol (internal standard) were extracted with diethyl ether. After centrifugation, the organic layer was evaporated to dryness. The residue was redissolved in the mobile phase and injected onto an octadecyl silica column (150 mm x 4.6 mm I.D.). The mobile phase was 0.05 M ammonium acetate (pH 4.5)-acetonitrile (85:15, v/v). Fluorometric detection (excitation 230 nm, emission 300 nm) was used. The minimum detectable level of nadolol in serum was 1 ng/ml.  相似文献   

19.
A method is described for the determination of S-(carboxymethyl)-L-cysteine in serum. After addition of S-(carboxyethyl)-L-cysteine as internal standard, both compounds are extracted into methanol, converted into fluorescent derivatives with o-phthalaldehyde and quantitatively determined by reversed-phase high-performance liquid chromatography. Chromatography of unwanted amino acid derivatives is avoided by column switching, thereby shortening analysis time and increasing column lifetime. The technique was applied in a study of the bioavailability of S-(carboxymethyl)-L-cysteine after oral administration to humans. The concentration-response curve was linear from 2 to 16 micrograms/ml; mean serum concentrations are reported.  相似文献   

20.
H. Hosotsubo 《Chromatographia》1988,25(10):887-890
Summary A high-performance liquid chromatographic method for the analysis of thiopental in 100l of human serum or plasma is described. The procedure involves protein precipitation with acetonitrile. The supernatant is directly injected into a chromatograph containing a reversed-phase CLC-ODS (Shimadzu) column. A 5050 (v/v) mixture of water-acetonitrile, at a flow-rate of 1.0ml/min is used as the mobile phase. Detection is carried out ata wavelength of 280nm. Total analysis time per sample is 10min. The assay was found to be linear in the range of 0.1 to 120g/ml. Reproducibility was good, with intra-assay coefficients of variation from 1.780 to 3.208% and inter-assay coefficients of variation from 3.241 to 4.860%. The absolute recoveries were 97.4 to 101,4%. Other drugs were tested for potential interference with the assay, but none was found.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号