首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 843 毫秒
1.
Fatty hydroxamic acid (FHA) immobilized in polyvinyl chloride (PVC) has been studied as a sensor element of an optical fibre chemical sensor for V(V). By using this instrument, V(V) in solution has been determined in the log concentration range of 0-2.5 (i.e. 1.0-300 mg/L). The detection limit was 1.0 mg/L. The relative standard deviation (R.S.D.) of the method for the reproducibility study at V(V) concentration of 200 mg/L and 300 mg/L were calculated to be 2.9% and 2.0%, respectively. Interference from foreign ions was also studied at 1:1 mole ratio of V(V):foreign ions. It was found that, Fe(III) ion interfered most in the determination of vanadium(V). Excellent agreement with ICP-AES method was achieved when the proposed method was applied towards determination of V(V).  相似文献   

2.
Junsomboon J  Jakmunee J 《Talanta》2008,76(2):365-368
A simple flow injection system using three 3-way solenoid valves as an electric control injection valve and with a simple home-made chloride ion selective electrode based on Ag/AgCl wire as a sensor for determination of water soluble chloride in admixtures and aggregates for cement has been developed. A liquid sample or an extract was injected into a water carrier stream which was then merged with 0.1M KNO(3) stream and flowed through a flow cell where the solution will be in contact with the sensor, producing a potential change recorded as a peak. A calibration graph in range of 10-100 mg L(-1) was obtained with a detection limit of 2 mg L(-1). Relative standard deviations for 7 replicates injecting of 20, 60 and 90 mg L(-1) chloride solutions were 1.0, 1.2 and 0.6%, respectively. Sample throughput of 60 h(-1) was achieved with the consumption of 1 mL each of electrolyte solution and water carrier. The developed method was validated by the British Standard methods.  相似文献   

3.
建立湿巾产品中苄索氯铵的超高效液相色谱检测方法。湿巾样品以甲醇-水溶液(1∶1)超声提取,振荡离心过滤后,用Phenomenex C18液相色谱柱分离,以二极管阵列检测器于220 nm波长处检测进行定性、定量。苄索氯铵的质量浓度在1~200 mg/L范围内与色谱峰面积线性良好,相关系数(r2)为0.9999。苄索氯铵的检出限为0.50 mg/L,色谱峰面积的相对标准偏差为2.17%(n=9),苄索氯铵的加标回收率为91.28%~98.65%。该方法样品处理简便快捷,测定结果准确可靠。  相似文献   

4.
Muzikár M  Havel J  Macka M 《Electrophoresis》2003,24(12-13):2252-2258
In this work, using a combination of experimental design (ED) and artificial neural networks (ANN), the composition of a triethanolamine-buffered chromate electrolyte was optimised for determination of sulphate anions in the presence of high chloride excess. The optimal electrolyte, allowing a baseline-resolved separation of sulphate from chloride present in a 1500 multiple excess in less than 170 s, consists of 10 mmol/L CrO(3), 2 mmol/L hexamethonium hydroxide, 10% methanol, and triethanolamine added to adjust the pH to 8.0. The method is suitable to a wide concentration range of chloride (4-1757 mg/L) and sulphate (4-590 mg/L) with linear calibration plots (R(2) = 0.9937-0.9999). Relative standard deviations are less than 2.0% for both anions for migration times and peak areas. The detection limits (hydrodynamic injection of 1 s) were 0.6 mg/L for sulphate and 0.5 mg/L for chloride. The method was successfully applied to determination of sulphate in mineral waters containing a high chloride concentration and to determination of sulphate traces in an anticancer drug injection preparation containing a physiological level of chloride. It was shown that alpha-cyclodextrin as an electrolyte additive has a significant potential for further increasing the separation selectivity for inorganic anions.  相似文献   

5.
张忠  王力春  鲁蕴甜 《色谱》2012,30(11):1113-1116
采用离子色谱法测定“地沟油”样品中钠离子和氯离子的含量,通过计算两者的比例关系确定样品中是否含有“地沟油”。使用去离子水提取“地沟油”样品中钠离子和氯离子。氯离子以20 nmol/L KOH溶液为淋洗液,AS19分离柱(250 mm×4 mm)分离,抑制器电流112 mA;钠离子以20 nmol/L甲基磺酸(MSA)为淋洗液,CS12分离柱(250 mm×4 mm)分离,抑制器电流59 mA;两者分离采用的其他相同色谱条件为: 柱温、检测器温度30 ℃,电导检测器检测,进样量25 μL,流量1 mL/min,峰面积定量。氯离子的检出限为0.005 mg/L,在0~5 mg/L范围内有良好的线性关系(r2=0.999988);钠离子的检出限为0.001 mg/L,在0~5 mg/L范围内有良好的线性关系(r2=0.999926)。氯离子平均加标回收率为94.2%,相对标准偏差(RSD)为2.4%;钠离子平均加标回收率为92.5%, RSD为2.7%。经测定、计算,正常食用油中钠离子和氯离子的物质的量比约为1,而“地沟油”中钠离子与氯离子的物质的量比高于4。“地沟油”中钠离子和氯离子的含量及其比例关系可作为判断“地沟油”的重要依据。  相似文献   

6.
A flow-through bulk optode based on the use of 1-(2-pyridylazo)-2-naphthol (PAN) immobilized in a plasticized poly(vinyl chloride) membrane entrapped in a cellulose support, in conjuntion with the flow injection analysis technique, is proposed for the determination of manganese(II). The calibration graph obtained at 570 nm was linear in the range 0.27-27.5 mg L(-1) (5 x 10(-6)-5 x 10(-4) M) Mn(II) with a detection limit of 0.18 mg L(-1). The coefficients of variation of the sensor response for 5.5 mg L(-1) of Mn(II) were +/-0.22% for consecutive measurements (n = 10), +/-0.48% between days (n = 5) and +/-0.38% between different membranes (n = 6). The sensor was readily regenerated with the carrier acetic acid/acetate buffer of pH 4.5. The method was applied to the determination of manganese in steels, waters and lemon tree leaves.  相似文献   

7.
An ion-exclusion chromatographic method with on-line desalinization for the determination of volatile fatty acids in landfill leachates is described. Highly sensitive conductivity detection of the organic acids was achieved by using dilute p-hydroxybenzoic acid solution as an eluent. Interference with mineral acids was reduced by treatment with barium chloride solution prior to desalinization. A silver-loaded cation-exchange guard column for the desalinization was installed in series with the analytical column to avoid the contamination of organic acids. This method features detection limits of 0.01 mg L(-1) formic acid, 0.02 mg L(-1) acetic acid, 0.05 mg L(-1) propionic acid, and 0.1 mg L(-1) butyric acid, respectively, with an injection of 20 microL sample. Application of the on-line desalinization LC method is illustrated for leachate samples from a Japanese sanitary landfill.  相似文献   

8.
A flow injection(FI) spectrophotometric method for the determination of anionic surfactants was developed on the basis of the competition for the cationic surfactant cetyl pyridine (CP+) chloride between the acidic dye methyl orange (MO) and anionic surfactants. In a pH 5.0 medium the cation of cetyl pyridine (CP+) reacts with dissociated methyl orange (MO-) to form an ion-associate complex, causing a blue shift of lambda(max) from 465 nm for MO- to 358 nm for the CP+ x MO- associate. The MO- in the ion-associate complex can be quantitatively substituted by such anionic surfactants as sodium dodecyl benzene sulfonate (DBS) or sodium lauryl sulfate (LS), leading to an increase in the absorbance measured at 465 nm. This increased absorbance value is proportional to the concentration of anionic surfactants. Various chemical and physical parameters for the FI spectrophotometric method were optimized, and interference-free levels were examined. At the optimized conditions, Beer's law was obeyed in the range 1.4 approximately 25 mg/L sodium DBS for an injected sample volume of 180 microL, and a detection limit of 0.22 mg/L for sodium DBS was achieved at a sampling rate of 90 h(-1). Eleven determinations of a 16 mg/L sodium DBS solution gave a RSD of 0.4%. The proposed method has successfully been applied to the determination of anionic surfactant concentration in waste water and in detergents.  相似文献   

9.
建立了阀切换-离子色谱法测定分析纯硫酸钠固体中痕量氯离子含量的方法。ICS-2100离子色谱系统,配置十通阀,用IonPac AS18色谱柱将硫酸钠固体样品中的氯离子和硫酸根离子预分离后,以IonPac TAC-ULP1为富集柱,将氯离子富集后在相同的IonPac AS18色谱柱上进行定量分析。同时以淋洗液发生器产生的不同浓度的KOH作为淋洗液,以抑制型电导检测器测定氯离子的含量。结果表明,阀切换-离子色谱法测定分析纯硫酸钠固体中的痕量氯离子,检出限为10 μg/L,线性相关系数(r2)大于0.999,实际样品的加标回收率为98.0%~103.0%,具有分离度和灵敏度高,选择性好,操作简单等特点。该方法能够准确测定硫酸钠固体中痕量氯离子的含量,适用于高纯化学试剂中痕量氯离子的分离测定。  相似文献   

10.
建立了离子色谱-抑制型电导快速检测氯化钾中微量溴离子和硫酸根离子的方法. 在优化的色谱条件下,Br?和SO4 2?分别在0.05~10 mg/L质量浓度范围内线性关系良好(相关系数r分别为0.995 1、0.996 2),方法检出限分别为0.029、0.020 mg/L. 氯化钾中Br?和SO4 2?的加标回收率在93.7%~99.0%范围内. 方法具有线性范围好、易于操作、灵敏度高等特点,可作为氯化钾中快速检测Br? 和SO4 2? 的质量控制方法.  相似文献   

11.
A new method based on surface-enhanced Raman spectroscopy (SERS) has been developed for sensitive and rapid detection of melamine. Spherical magnetic-core gold-shell nanoparticles (AuNPs) and rod-shaped gold nanoparticles (nanorods) labeled with a Raman-active compound were used to form a complex with the melamine molecules. 5,5'-Dithiobis(2-nitrobenzoic acid) was used as Raman-active compound because it is readily adsorbed by a gold nanoparticle surface forming a self-assembled monolayer (SAM) and has strong Raman scattering at 1330 cm(-1), because of the symmetric NO(2) stretch. The calibration curve was obtained by plotting Raman band area at 1330 cm(-1) against melamine concentration. A linear relationship was obtained with a high determination coefficient (R(2)=0.997). The method was validated for linearity, sensitivity, precision (intra-day and inter-day repeatability), and recovery. In the model system, the limits of detection (LOD) and quantification (LOQ) were 0.38 and 1.27 mg L(-1), respectively. For melamine-spiked milk samples, LOD and LOQ values were 0.39 mg L(-1) and 1.30 mg L(-1), respectively. Intra and inter-day precision were 3.73 and 4.94 %, respectively. This method was applied to samples of skimmed milk that had been spiked with melamine at different concentrations. The recovery of the method was 95-109 % in the concentration range 2-15 mg L(-1), and average RSD was 1.71 %. Total analysis time was less than 15 min.  相似文献   

12.
汪辉  刘江  李晰晖  曹阳  黄小贝  李永强 《色谱》2017,35(5):558-562
建立了固相萃取-超高效液相色谱-串联质谱测定乳粉和果冻中氯化胆碱的分析方法。样品在10 mL 0.02mol/L乙酸铵溶液(冰乙酸调节pH至3.0)中水解3 h后离心,上清液经DIKMA ProElut PLS固相萃取柱(60 mg/3 mL)净化后,用Agilent ZORBAX 300 SCX色谱柱(150 mm×2.1 mm,5μm)进行分离,通过电喷雾正离子(ESI~+)模式电离,多反应监测(MRM)模式进行定性和定量分析。方法的检出限(LOD,S/N=3)和定量限(LOQ,S/N=10)分别为0.15 mg/kg和0.50 mg/kg,加标回收率为70.8%~100.2%,相对标准偏差(RSD)均不大于6.83%(n=6)。目标化合物在0.05~8.0 mg/L范围内线性关系良好,线性方程为Y=2.05×10~5X+3.24×10~4,相关系数(r)为0.996。对市售乳粉和果冻中的氯化胆碱进行检测,结果表明,乳粉和果冻中氯化胆碱的含量分别为251.0~2 448 mg/kg和0.261~0.314 mg/kg。该法准确可靠、灵敏度高,适用于乳粉和果冻中氯化胆碱的测定。  相似文献   

13.
建立了一种在线基体消除的方法,采用离子色谱法测定了墨水染料中的氯和硫酸盐。样品经溶解、稀释后直接进样,在纯水的输送下依次经过DIONEX OnGuard Ⅱ P和IonPac NG1柱,在线实现了墨水样品中染料和疏水性干扰基体的去除,死时间流出的待测阴离子浓缩于阴离子交换柱IonPac AG11-HC。浓缩柱经阀切换进入离子色谱系统,以4.5 mmol/L Na2CO3-0.8 mmol/L NaHCO3作为淋洗液,流速1.2 mL/min,待测离子经IonPac AS23(4 mm×250 mm)分析柱分离,采用DIONEX DS6电导检测器检测,外标法定量。Cl-和SO2-4的线性范围分别为0.05~5.0、0.1~10.0 mg/L,相关系数分别为0.999 8和 0.999 7,加标回收率为94%~103%,相对标准偏差(n=11)小于1.0%,检出限(S/N=3)分别为0.02、0.05 mg/L。该方法用于墨水染料中氯和硫酸盐的测定,结果满意。  相似文献   

14.
Bis(8-hydroxy quinoline-5-solphonate) cerium(III) chloride (Ce(QS)(2)Cl) (L) was synthesized and then used as a novel fluorescent sensor for anion recognition. Preliminarily study showed that fluorescence of L enhanced selectively in the presence of HPO(4)(2-) ion. This enhancement is attributed to a 1:1 complex formation between L and HPO(4)(2-) anion. The association constant of 1:1 complex of L-HPO(4)(2-) was calculated as 3.0×10(6). Thus, L was utilized as a basis for a selective detection of HPO(4)(2-) anion in solution. The linear response range of the proposed fluorescent chemo-sensor covers a concentration range of HPO(4)(2-) from 3.3×10(-7) to 5.0×10(-6) mol L(-1) with a detection limit of 2.5×10(-8) mol L(-1). L showed selective and sensitive fluorescence enhancement response toward HPO(4)(2-) ion in comparison with I(3)(-), NO(3)(-), CN(-), CO(3)(2-), Br(-), Cl(-), F(-), H(2)PO(4)(-) and SO(4)(2-) ions. It was probably attributed to the higher stability of the inorganic complex between HPO(4)(2-) ion and L. The method was successfully applied for analysis of phosphate ions in some fertilizers samples.  相似文献   

15.
Hu Z  Ye M  Pan G  Zhang T  Zhong N 《色谱》2012,30(4):391-394
建立了一种抑制电导检测-离子色谱(IC)同时测定草甘膦生产工艺中母液里的草甘膦及其副产物、无机阴离子的方法。样品经过滤后直接进样,色谱条件: IonPac AS11-HC分离柱(250 mm×4 mm)和IonPac AG11-HC保护柱(50 mm×4 mm),在线淋洗液发生器KOH梯度淋洗,流速1.0 mL/min,采用抑制电导检测。草甘膦、甲基草甘膦、六甲基磷酰三胺(HMPA)、增甘膦、亚磷酸、磷酸、Cl~和SO2~4的线性范围分别为0.1~20 mg/L、0.1~20 mg/L、0.1~50 mg/L、0.25~50 mg/L、0.05~20 mg/L、0.2~50 mg/L、0.02~20 mg/L和0.05~50 mg/L,相关系数分别为0.9995、0.9993、0.9999、0.9998、0.9999、0.9985、0.9999和0.9980,加标回收率为93.7%~104.0%,相对标准偏差均小于2.5% (n=7),检出限(以信噪比(S/N)=3计)为0.002~0.025 mg/L。该方法用于草甘膦生产工艺中母液里草甘膦及其含磷副产物和无机阴离子的测定,结果令人满意。  相似文献   

16.
研究了离子色谱-直接电导检测法分离测定离子液体中的卤素离子(F~-、Cl~-、Br~-)杂质.采用Shim-pack IC-A3阴离子交换色谱柱,考察了淋洗液种类及浓度、流速和色谱柱温度对分离测定的影响.最佳色谱条件为:以1.25 mmol/L邻苯二甲酸氢钾为淋洗液,流速1.5 mL/min,色谱柱温45 ℃.在此条件下可以基线分离卤素离子,且NO~-_3、BF~-_4、SO~(2-)_4不干扰测定.该法测定卤素离子的检出限(S/N=3)为0.02 ~0.11 mg/L,峰面积的相对标准偏差(n=5)不大于0.7%,F~-、Cl~- 和Br~- 的标准曲线的线性范围分别为0.1 ~50、0.1 ~50、0.5 ~100 mg/L.将方法用于烷基咪唑四氟硼酸盐离子液体中卤素离子杂质的测定,加标回收率为98% ~102%.  相似文献   

17.
A new counterion-buffered molybdate electrolyte was developed and optimized for simultaneous quantitative determination of up to eight anions (chloride, sulphate, oxalate, fluoride, formate, malonate, succinate, and acetate) in Bayer liquor by capillary electrophoresis with indirect detection at 214 nm. The separation parameters were optimized in respect to separation of the critical analyte group fluoride-formate-malonate, with the optimal electrolyte prepared from molybdic trioxide containing 5.0 mmol/L MoO3, 1.3 mmol/L cetyltrimethylammonium bromide (CTAB), and buffered with diethanolamine (DEA) to pH 9.2 (ca. 20 mM DEA). Total length of separation capillary was 80 cm, resulting in run time of under 4 min. The method is suitable for a wide concentration range of the analytes (1-50 mg/L) with linear calibration plots (R2 = 0.9983-0.9999). Relative standard deviations were 0.05%-0.07% for migration times and 0.67%-2.04% for peak areas. The detection limits were in the range of 0.17-0.51 mg/L or 2-10 micromol/L (hydrostatic injection of 30 s of 1000 x diluted sample). Due to its good buffering capacity, the electrolyte exhibited an excellent ruggedness and good tolerance to the alkaline samples. Consequently, Bayer liquor samples could be diluted as little as 100 x which allows more sensitive determination of minor components over previous methods. The method was successfully applied to analysis of Bayer liquor samples with recoveries in the range of 95-105%.  相似文献   

18.
Zinc ions form a yellow complex with di-2-pyridyl ketone salicyloylhydrazone (DPKSH). This complex showed maximum absorption at 376 nm, and it was used to develop spectrophotometric flow injection methods for Zn(II) determination in different samples. Two types of flow systems were proposed. In the first system, a linear analytical curve was obtained in a concentration range from 0.217 to 4.60 mg L(-1) Zn(II), with a detection limit of 48.8 microg L(-1). In the second system, a minicolumn packed with an anion exchanger resin was used to concentrate Zn(II) as a chlorocomplex, and a linear analytical curve within a concentration range from 0.0824 to 2.06 mg L(-1) Zn(II) was obtained, having a detection limit of 13.9 microg L(-1). The developed methods were applied to biological and pharmaceutical samples, and a great compliance was observed by comparing the results with ones obtained by an atomic absorption technique.  相似文献   

19.
A sensitive spectrophotometric method for the direct determination of copper in aqueous samples without a preconcentration step has been developed. It is based on the formation of a yellow complex with the chromogenic reagent di-2-pyridyl ketone benzoylhydrazone (dPKBH) in an alkaline medium. The complex stoichiometry was 1:2 (Cu:dPKBH) and presents maximum absorbance at 370 nm. The influence of chemical variables affecting the behaviour of the system such as pH, concentration of dPKBH, buffer solution and ethanol, order of addition of the reagents and stability of the complex, were evaluated. The molar absorptivity (epsilon) was 3.92x10(4) L mol(-1) cm(-1), and Beer's law was obeyed up to 3 mg L(-1) of copper. The relative standard deviation was 0.46% (n=11) for a sample containing 1 mg L(-1) Cu(II). The limit of detection was 2.5 micro g L(-1) and was therefore more sensitive than the direct methods reported previously. Finally, the method was successfully validated by analysing several real samples with different matrices, such as tap water, natural water or copper alloys, with an average relative error of 2.46%.  相似文献   

20.
The present work reports a new, simple and rapid reversed flow-injection (r-FI) method for the accurate and precise spectrophotometric determination of captopril (CPL) in pharmaceutical formulations. The method is based on the inhibitory effect of CPL on the complex formation of Co(II) with 2,2'-dipyridyl-2-pyridylhydrazone (DPPH). The chemical and FI variables were studied and optimized. The calibration graph was linear in the range 0-250 mg l(-1) CPL, at a sampling rate of 60 injections per hour. The method was found to be very precise [s(r)=0.8% at 100.0 mg l(-1) CPL (n=12)] and the 3sigma detection limit (c(L)=2.5 mg l(-1)) was quite satisfactory. Its application to commercially available pharmaceuticals produced excellent results, with a mean relative error of e(r)<1.0%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号