首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A simultaneous steam distillation-solvent extraction (SDE) procedure was used for determining polychrlorinated biphenyls, polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCBs, PCDDs and PCDFs) at sub-ppb levels in water samples. Recoveries of 39.8–138.7% and a standard deviation of lower than 10% were achieved for the individual coplanar PCB and the 2,3,7,8-substituted PCDD/F congeners. SDE is a fast, clean, inexpensive and reproducible procedure for the determination of individual PCBs, PCDDs and PCDFs in waters at very low concentrations.  相似文献   

2.
Gas chromatography coupled to ion trap tandem mass spectrometry (CG-MS-MS) has been evaluated for the analysis of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dl-PCBs) in vegetable oil samples containing different concentration levels (0.2-6 pg WHO-TEQ g(-1) for both PCDD/Fs and dl-PCBs) of the 29 toxic congeners of PCDD/F and dioxin-like PCBs. The effect of potential interfering compounds such as polychlorinated naphthalenes (PCNs), polychlorinated biphenyls (PCBs) and polychlorinated diphenylethers (PCDEs) on the quantification of mono-ortho PCBs has been investigated. In addition, the influence of the clean-up procedure on the final determination by CG-MS-MS was studied, showing that the quality of the results depends to a great extent on this analytical step. Quality parameters have been established and good precisions (CV: 3-19%) and low limits of detection for PCDD/Fs (0.04-0.20 pg g(-1) oil) and dl-PCBs (0.08-0.64 pg g(-1) oil) were obtained. The method was validated by a comparison of the CG-MS-MS results with those obtained by GC-HRMS.  相似文献   

3.
The chemical-activated luciferase expression (CALUX) assay is a reporter gene assay that detects dioxin-like compounds based on their ability to activate the aryl hydrocarbon receptor (AhR) and thus expression of the reporter gene. In this paper, the CALUX assay was examined for its application in the screening of polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (dioxin-like PCBs) in retail fish. The sample extracts were cleaned up on a sulfuric acid-silica gel column followed by an activated carbon column, and the AhR activity of the separated PCDD/F and dioxin-like PCB fractions was determined using the assay. The quantitative limit for 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) was 0.98 pg ml(-1) (0.19 pg assay(-1) in the standard curve, corresponding to 0.16 pg g(-1) of CALUX-based toxic equivalency (2,3,7,8-TCDD equivalents) in the tested sample. Recovery tests in which dioxins were added to fish samples resulted in acceptable recoveries (77-117%). The CALUX assay performed well in the analysis of dioxins in fish samples and a comparative study revealed a strong correlation between the CALUX assay and high-resolution gas chromatography-high-resolution mass spectrometry analysis for the determination of PCDD/Fs (r = 0.89) and dioxin-like PCBs (r = 0.91) in retail fish (n = 22). These data revealed that the CALUX assay would be a useful screening method for PCDD/Fs and dioxin-like PCBs in retail fish.  相似文献   

4.
Polychlorinated naphthalenes (PCNs) are candidates for inclusion in the Stockholm Convention on persistent organic pollutants. PCNs are structurally and toxicologically similar to 2,3,7,8-tetrachlorodibenzo-p-dioxin (2,3,7,8-TCDD) and its analogues. Intake in food is considered to be an important human exposure pathway for PCNs. In this preliminary study, cheese and butter samples were analysed for PCNs, polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) using an isotope dilution gas chromatography high-resolution mass spectrometry method. The aim of this study was to evaluate the PCN concentrations in the cheese and butter samples and to compare them with the PCDD, PCDF and PCB concentrations. The PCN concentrations were 5.6–103 pg g?1 of wet weight in the seven cheese samples tested and 5.0–199 pg g?1 of wet weight in the seven butter samples tested. The mass concentrations of lower chlorinated congeners were greater than those of the higher chlorinated congeners. Congeners of CN45/36, CN27/30 and CN33/34/37 were much more abundant than other congeners found in tetrachlorinated PCNs. Congeners of CN51, CN66/67 and CN73 were determined to be the predominant congeners in penta-, hexa- and heptachlorinated homologs, respectively. The PCNs contributed around 5% of the total PCN, PCDD, PCDF and PCB toxic equivalence (TEQ) values. CN73 was found to be the dominant PCN congener and contributed more than 40% to the PCN TEQ value. Congeners CN66/67, CN69 and CN63 were also found at relatively high levels. The PCB congener CB118 was the predominant congener (by mass-based concentration) of the 12 dioxin-like PCBs (dl-PCBs). The PCBs contributed 53.8% of the total TEQ, and congener CB126 contributed more than any other compound that was analysed to the total TEQ. The PCDDs and PCDFs contributed 11.6% and 29.7% of the total TEQ values, respectively.  相似文献   

5.
Pressurized liquid extraction (PLE) applying three extraction cycles, temperature and pressure, improved the efficiency of solvent extraction when compared with the classical Soxhlet extraction. Polychlorinated-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like PCBs (coplanar polychlorinated biphenyls (Co-PCBs)) in two Certified Reference Materials [DX-1 (sediment) and BCR 529 (soil)] and in two contaminated environmental samples (sediment and soil) were extracted by ASE and Soxhlet methods. Unlike data previously reported by other authors, results demonstrated that ASE using n-hexane as solvent and three extraction cycles, 12.4 MPa (1800 psi) and 150 degrees C achieves similar recovery results than the classical Soxhlet extraction for PCDFs and Co-PCBs, and better recovery results for PCDDs. ASE extraction, performed in less time and with less solvent proved to be, under optimized conditions, an excellent extraction technique for the simultaneous analysis of PCDD/PCDFs and Co-PCBs from environmental samples. Such fast analytical methodology, having the best cost-efficiency ratio, will improve the control and will provide more information about the occurrence of dioxins and the levels of toxicity and thereby will contribute to increase human health.  相似文献   

6.
 A novel, simple inexpensive and rapid clean-up procedure is presented for the separation and quantitative determination of polychlorinated biphenyls (ortho-PCBs), coplanar non-ortho-PCBs (PCB No. 77, 126, 169) and polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in environmental samples. This clean-up procedure is the first method separating ortho-PCBs, non-ortho-PCBs and PCDD/PCDFs in one step with a single activated alumina column. Firstly, the ortho-PCBs are eluted from the activated alumina with a non-polar solvent. The non-ortho-PCBs are isolated in the second fraction with a more polar solvent-mixture, and finally the PCDD/PCDFs are collected in a polar fraction. This clean-up procedure was used to determine the congener-specific concentrations of ortho-PCBs, non-ortho-PCBs 77, 126 and 169 and PCDD/PCDFs in two different seepage waters and in one sewage sludge by HRGC and HRMS. The toxic equivalent quantities (TEQs) of the individual PCDD/PCDF-congeners and some toxic coplanar PCB-congeners were estimated. Received: 26 June 1996/Revised: 11 September 1996/Accepted: 14 September 1996  相似文献   

7.
2014年1月在杭州市选择5个点位采集大气颗粒物PM2.5样品,采用同位素稀释高分辨气相色谱/高分辨质谱测定PM2.5中的二恶英(PCDD/Fs)和多氯联苯(PCBs),对PM2.5的污染状况以及PM2.5中PCDD/Fs和PCBs的污染水平及分布特征进行了研究。PM2.5的质量浓度范围为85~168 μg/m3,PM2.5污染较重,但与2004年同期相比明显降低。PM2.5中PCDD/Fs的毒性当量(TEQ)为0.277~0.488 pg I-TEQ/m3,明显高于2004年同期采集样品。颗粒物中PCDD/Fs以八氯代二苯并-对-二恶英(OCDD)为主,毒性当量主要贡献者为2,3,4,7,8-五氯代二苯并呋喃(2,3,4,7,8-PeCDF)。PM2.5中PCBs的质量浓度范围为2.9~8.1 pg/m3,二恶英类多氯联苯(DL-PCBs)的毒性当量范围为2.6~6.1 fg WHO-TEQ/m3,污染较低。PCBs在颗粒物中分布以PCB-28为主,但对毒性当量贡献最大的为PCB-126。PCDD/Fs和PCBs的气-固分配特征表现为PCDD/Fs主要分布于颗粒物中,而PCBs主要分布于气相中。  相似文献   

8.
Two gas chromatography-mass spectrometry systems equipped with an ion-trap mass analyzer working in tandem mode (GC-MS-MS) were evaluated for the determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (PCBs) in food samples. The performance of the two ion-trap instruments, which dispose of an external ion source (ThermoFinnigan GCQ/Polaris) and internal ionization (Varian Saturn 2,200), have been compared in terms of linearity, repeatability, limit of detection and long-term precision. Both instruments provided similar run-to-run and day-to-day precisions, ranging from 2% to 8% and between 2% and 13%, and instrumental limits of detection between 0.09 and 0.36 pg injected for PCDD/Fs and from 0.03 to 0.09 pg injected for dioxin-like PCBs. Although both instruments seem to be suitable for food analysis, only the use of external ionization allowed to achieve reliable results for PCDD/F determination at concentrations close to the maximum residue levels established by the EU for foods. Internal ionization provides high limits of detection (from 10- to 30-fold higher) and worse precision (RSD, 14-43%). In contrast, for dioxin-like PCBs both instruments allowed to obtain excellent results with precisions lower than 15%.  相似文献   

9.
样品采用索氏抽提,抽提液依次经酸性硅胶床、多段混合硅胶柱和凝胶渗透色谱柱(GPC)净化后,用Florisil硅藻土柱分离出样品中的二噁英(PCDD/Fs)和类二噁英多氯联苯(dioxin-like PCBs),采用同位素稀释法和气相色谱/高分辨质谱联用仪(GC/HRMS)测定了其中的17个2,3,7,8-氯取代二噁英类化合物和12个类二噁英多氯联苯。结果表明,用该法分析二噁英和多氯联苯标准溶液,平行4次的分析结果为:RSD(PCDD/Fs)<8.9%,RSD(PCBs)<11.4%;回收率可达60%-105%。PCDD/Fs和PCBs的检出限分别为0.1-0.8 pg/g和0.05-0.6 pg/g。应用本方法成功测定了沉积物、淤泥、土壤和飞灰中的二噁英和类二噁英多氯联苯,并计算出它们的毒性当量。  相似文献   

10.
Due to safety concerns regarding dietary exposure to POPs, regulatory bodies are issuing detailed guidelines for testing for polychlorodibenzodioxins (PCDDs) and polychlorodibenzofurans (PCDFs) ('dioxins') and dioxin‐like (DL)‐PCBs in foods of animal origin. Determination of the aforesaid chemicals at regulatory levels requires highly selective and sensitive testing techniques. The new generation of low‐resolution mass spectrometers (triple quadrupoles) allows very low levels of quantification to be reached (in the order of tens of femtograms), thus suggesting a potential for their application in food and feed analysis. The performance of the low‐resolution tandem mass spectrometry (LRMS/MS) approach with triple quadrupoles was assessed on a qualified set of food samples from proficiency tests (PTs) and defense analysis. Accuracy was tested comparing the results with data from high‐resolution mass spectrometry (HRMS) and with consensus values from PTs. The cumulative TEQ results were characterized by deviations not exceeding 15% of PCDD + PCDF, DL‐PCB, and PCDD + PCDF + DL‐PCB (TEQTOT) reference consensus values (sample TEQTOT range, 2.29–25.1 pgWHO‐TEQ97/g fat). Congener analytical variabilities did not influence significantly the WHO‐TEQ97 outcome of the corresponding sample. This preliminary performance evaluation highlights the potential of LRMS/MS as a routine technique for quantitative analysis of PCDDs, PCDFs, and DL‐PCBs in food. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

11.
Simultaneous determination of PCDDs, PCDFs, PCBs and PBDEs in food   总被引:4,自引:0,他引:4  
Fernandes A  White S  D'Silva K  Rose M 《Talanta》2004,63(5):1147-1155
Established and comprehensively validated methodology for the analysis of PCDDs, PCDFs and polychlorinated biphenyls (PCBs) in food, animal feed and other matrices is presented. The method achieves the analytical standards of EU protocols (2002/69/EC and 2002/70/EC) that are used to determine the compliance of food and animal feed to maximum permissible levels of chlorinated dioxins in these commodities. The methodology provides WHO–TEQ data for dioxins and PCBs as well as individual concentrations for toxic PCDD/F congeners and >50 commonly occurring PCBs. In addition, the methodology allows the simultaneous determination of individual polybrominated diphenylether (PBDE) congeners. A wide range of 13Carbon-labelled surrogates allow accurate internal standardisation, and measurements are carried out using high resolution GC coupled to high resolution mass spectrometry except for mono-, tetra, ortho-substituted PCBs where unit resolution mass spectrometry can be used instead. Evidence of internal as well as external validation through the frequent use of reference materials, and successful participation in international inter-comparison exercises over many years is presented. A large number of different food types have been analysed for dioxins and PCBs using this methodology over several years and typical congener profiles for various food matrices are discussed.  相似文献   

12.
采用HRGC/HRMS和同位素稀释定量技术对样品中17种4~8个氯原子取代的二噁英和呋喃(PCDDs/Fs)与12种共平面多氯联苯(PCBs)定量分析。样品经索式抽提、FMSPowerPrep系统净化、浓缩,利用高分辨气相色谱/高分辨质谱联用仪的多离子检测方式,同位素稀释技术对样品中的目标化合物进行定性和定量。该方法的检出限为pg/g水平。13C同位素内标回收率范围为47%~100%。对3个CRM鱼样中17个PCDDs/Fs和4个PCBs的检测值均在标准定值允许误差范围内。对5个不同的实际样品鱼进行测定表明,样品的回收率在48%~100%之间,回收率的相对标准偏差小于20%;对同一样品进行定量检测的精密度测试结果表明,17种PCDDs/Fs浓度的RSD低于16%,12种PCBs浓度的RSD低于11%。本方法定量分析重现性良好。  相似文献   

13.
Separations of eight persistent organohalogenated classes of pollutants, organochlorinated pesticides (OCPs), polychlorinated biphenyls (PCBs), polychlorinated diphenyl ethers (PBDEs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), polychlorinated naphthalenes (PCNs), polychlorinated terphenyls (PCTs) and toxaphene (CTT) by comprehensive two-dimensional gas chromatography (GC x GC) were evaluated. Columns with different polarity and selectivity, including ZB-5, HT-8, DB-17 and BP-10, were selected as first dimension and combined with columns of increasing polarity in the second dimension, i.e. HT-8, BPX-50 and Carbowax (or Supelcowax-10). In total nine column combinations were tested. Because the main interest of the study was fast screening of the test xenobiotic families in complex matrices, in all cases, attention was primarily focussed on group-type separation. Nevertheless, within-group separation was also considered, especially for those classes containing particularly toxic congeners, such as PCBs and PCDD/Fs. Although none of the assayed column sets allowed the simultaneous and complete separation of all pollutants classes, some column combinations provided satisfactory separations among selected families and the rest of pollutants investigated. That was, for instance, the case of HT-8 x BPX-50 for PBDEs and PCDD/Fs, DB-17 x HT-8 for PCNs and OCPs and BP-10 x BPX-50 for CTT, PCDD/Fs and PBDEs. The feasibility of the proposed approach for the fast screening of the target classes of pollutants in complex samples was illustrated by the analysis of food and marine fat samples prepared using simplified miniaturised sample treatment methods.  相似文献   

14.
Polychlorinated dibenzothiophenes (PCDT) have recently been identified in a series of environmental samples. Since their masses are very close to those of the polychlorinated dibenzodioxins (PCDD), low resolution mass selective detection cannot be used to distinguish between these two classes of compounds. A method is presented which may allow this, involving the oxidation of the PCDTs to the corresponding sulfones which have a higher mass than the PCDDs. If needed, the PCDTO2s can easily be separated from the PCDDs and the polychlorinated dibenzofurans (PCDFs) by simple chromatographic techniques. The PCDDs/Fs are apparently stable under the oxidative conditions so that now a determination of PCDDs and PCDFs becomes possible without interference from PCDTs.  相似文献   

15.
All the possible polychlorinated aromatic compounds in the classes of dibenzodioxins (PCDDs), dibenzofurans (PCDFs), and biphenyls (PCBs) were studied by the quantum chemical methods of HF/6-311++G(d,p), B3LYP/6-311++G(d,p), and MP2/cc-pVTZ. The calculated stabilities and structures of these compounds were compared with the available data on their abundance and toxicity. Prediction models for trends in energy and planarity among these congeners were proposed. The results discussed here can help contribute to the understanding of the role of dioxin-like compounds (DLCs) in the environment.  相似文献   

16.
Method validation was performed on the collection and extraction procedures for an analysis of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (DLPCBs) in flue gas. The adoption of the rapid pressurized liquid extraction (PLE) technique was evaluated for extraction from polyurethane foam plugs (PUFPs) and fly ash. With respect to extraction from PUFPs, dichloromethane PLE showed an extraction efficiency equivalent to that of conventional acetone Soxhlet, while toluene PLE was found to have a lower extraction efficiency from fly ash than toluene Soxhlet. The collection ability of three sampling methods, employed in the Japanese standard analytical method JIS K0311 (revised in 2005) was evaluated by evaluating the distribution of gaseous PCDD/Fs and DLPCBs in each collection compartment in sampling trains. A DiOANA® fibrous alumina filter and a PUFP, newly employed trapping devices in the revised JIS method, were found to trap gaseous analytes effectively. The validation of the two newly employed sampling methods (DiOANA and PUFP) was tested by parallel measurements of the methods with a conventional five-impinger method, and good agreements on the PCDD/Fs and DLPCBs quantities were demonstrated.  相似文献   

17.
A method consisting of automated supercritical fluid extraction (SFE) with simultaneous cleanup by a solid-phase trap was developed for fast analysis of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in soil. SFE was optimised to replace conventional liquid-based methods in routine analyses of PCDD/PCDFs in sawmill soil contaminated by a chlorophenol formulation. PCDD/PCDFs were quantitatively extracted in 60 min using CO2 at 400 atm and 100 degrees C without a modifier. A trap containing a small amount of activated carbon mixed with Celite efficiently collected PCDD/PCDFs after SFE. After SFE co-extracted impurities were eluted out from the trap with 4 ml of hexane and PCDD/PCDFs were eluted with 10 ml of toluene. The concentrations and TCDD-equivalent of PCDD/PCDFs corresponded to the results of traditional solvent extraction method (Soxhlet) in six sawmill soils tested. The performance of the trap was maintained over a long period of time (nearly 100 extractions).  相似文献   

18.
Matrix–matched environmental certified reference materials (CRMs) are one of the most useful tools to validate analytical methods, assess analytical laboratory performance and to assist in the resolution of data conflicts between laboratories. This paper describes the development of a lake sediment as a CRM for polychorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DLPCBs). The presence of DLPCBs in the environment is of increased concern and analytical methods are being developed internationally for monitoring DLPCBs in the environment. This paper also reports the results of an international interlaboratory study involving thirty-five laboratories from seventeen countries, conducted to characterize and validate levels of a sediment reference material for PCDDs, PCDFs and DLPCBs.  相似文献   

19.
Hydrogen gas and the valuable material hydroxylapatite have successfully been produced from biomass wastes by hydrothermal gasification. However, it was expected that toxic compounds might be produced through the reaction. It was therefore important to clarify whether toxic compounds were synthesized in hydrothermal gasification of biowastes since dioxins are categorized among the most toxic compounds for humans. This is particularly true of biomass wastes containing hetero-atoms in organic matrices. In this study, formation of the dioxins polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and certain dioxin-like polychlorinated biphenyls (PCBs) were examined. Chicken manure and cattle manure were tested as real biowastes for hydrothermal gasification and the produced compounds in the liquid and solid phases were analyzed for detection of dioxins by gas chromatography/mass spectrometry (GC/MS). The total toxic equivalent quantities (the total TEQ) of dioxins produced by the hydrothermal gasification were found to be much lower than regulation levels in Japan require and therefore the products require no additional post treatments.  相似文献   

20.
Matrix-matched environmental certified reference materials (CRMs) are one of the most useful tools to validate analytical methods, assess analytical laboratory performance and to assist in the resolution of data conflicts between laboratories. This paper describes the development of a lake sediment as a CRM for polychorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and dioxin-like polychlorinated biphenyls (DLPCBs). The presence of DLPCBs in the environment is of increased concern and analytical methods are being developed internationally for monitoring DLPCBs in the environment. This paper also reports the results of an international interlaboratory study involving thirty-five laboratories from seventeen countries, conducted to characterize and validate levels of a sediment reference material for PCDDs, PCDFs and DLPCBs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号