首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The Penning-trap mass spectrometer SHIPTRAP allows precision mass measurements of rare isotopes produced in fusion-evaporation reactions. In the first period of operation the masses of more than 50 neutron-deficient radionuclides have been measured. In this paper the perspectives for direct mass measurements of rare isotopes around nobelium are discussed and the achievable precision is addressed. The temporal stability of the magnetic field, an important issue for the long measurement times resulting from the low production rates, was investigated and the time-dependent uncertainty due to magnetic field fluctuations was determined. Based on the present performance direct mass measurements of nobelium isotopes are already feasible. With several technical improvements heavier elements between Z=102–105 will be in reach.  相似文献   

2.
A carbon-cluster ion source has been installed and tested at SHIPTRAP, the Penning-trap mass spectrometer for precision mass measurements of heavy elements at GSI. Carbon-cluster ions 12Cn +, 5 ≤n ≤23, were produced by laser-induced desorption and ionization from a carbon sample. They were tested for the first time as reference ions in an on-line mass measurement of the radionuclides 144Dy, 146Dy and 147Ho. In addition, carbon clusters of various sizes were used for an investigation of the systematic uncertainty of SHIPTRAP covering a mass range from 84 u to 240 u. The mass-dependent uncertainty was found to be negligible for the case of (m-m ref)< 100 u. However, a systematic uncertainty of 4.5 ×10-8 was revealed.  相似文献   

3.
The Penning-trap mass spectrometer SHIPTRAP was designed for precision mass measurements of radionuclides produced in fusion–evaporation reactions. The latest measurement campaign covered heavy nuclei (A>90) related to the astrophysical rapid proton capture process. The masses of 34 neutron-deficient radionuclides have been measured since February 2006 with relative uncertainties between 5×10−8 and 1×10−7. Furthermore, the use of an octupolar RF excitation for the time-of-flight ion-cyclotron-resonance technique was investigated and an increase of the resolving power by a factor of ten was observed in agreement with simulations. This will allow to resolve isomeric states with excitation energies of a few 10 keV only.   相似文献   

4.
The theory of octupolar-excitation ion-cyclotron-resonance mass spectrometry is presented which predicts an increase of up to several orders of magnitude in resolving power under certain conditions. The new method has been applied for a direct Penning-trap mass-ratio determination of the (164)Er-(164)Dy mass doublet. (164)Er is a candidate for the search for neutrinoless double-electron capture. However, the measured Q(??) value of 25.07(12) keV results in a half-life of 10(30) years for a 1 eV Majorana-neutrino mass.  相似文献   

5.
6.
Penning traps are used to perform very precise mass measurements on exotic and stable nuclei covering a variety of topics. In order to reach the highest accuracy, only one ion must be stored and measured in the trap. The mass is determined from the oscillation frequencies, by detecting the current the stored ion induces on the trap electrodes. This is a well-known technique demonstrated for ions with low or medium mass-to-charge ratios. Another technique recently proposed, and referred to as Quantum Sensor, aims at extending the applicability of single-ion Penning-trap measurements through the full atomic mass scale. The technique substitutes the electronic detection by the detection of fluorescence photons from a laser-cooled ion stored in a second Penning trap, thereafter this ion interacts with the ion of interest. The new device is under completion at the University of Granada (Spain) within the project TRAPSENSOR. This paper will present the status of this project.  相似文献   

7.
《Hyperfine Interactions》2001,132(1-4):491-495
SHIPTRAP will allow direct measurement of masses of transuranium nuclides. The method of choice is a Penning trap spectrometer coupled to the SHIP (Separator for Heavy Ion Products) facility at GSI, Darmstadt. In this paper the impact of the SHIPTRAP facility, with its capability of systematic mass measurements with high precision, is explored. Rather few masses of nuclides above uranium are presently known experimentally. In the region of nuclides above Z=100 no ground state masses were measured directly. SHIPTRAP will play an important role in systematically mapping out this area. Possible candidates for direct mass measurements, even with small or very small production cross sections, are presented. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

8.
A novel system consisting of RF quadrupole and time-of-flight sections is proposed, in which ions can be cooled, bunched, mass separated with a resolution sufficient to differentiate between isobars, and guided to different experimental setups, e.g. for precision mass measurements or mass-resolved decay spectroscopy. It enables multiplexed operation of several connected experiments and interleaved measurements using different nuclides in one connected experiment. Such a system could be employed advantageously at in-flight facilities, at which experiments with stopped exotic nuclei are made possible using gas-filled stopping cells, such as SHIPTRAP at GSI, or potentially at ISOL facilities. First results for individual stages of the system are presented.  相似文献   

9.
The cyclotron frequencies of singly charged carbon clusters Cn + (n ≥ 2) were measured with the Penning-trap mass spectrometer ISOLTRAP at ISOLDE/CERN. The present limit of mass accuracy δm/m = 1.2 . 10-8 and the extent of the mass-dependent systematic shift (δm/m)sys = 1.7(0.6) . 10-10/u . (m - m ref) of the setup were investigated for the first time. In addition, absolute mass measurements by use of pure clusters of the most abundant carbon isotope 12C are now possible at ISOLTRAP. Received: 21 March 2002 / Accepted: 16 May 2002 / Published online: 31 October 2002 RID="a" ID="a"Present address: CERN, CH-1211 Geneva 23, Switzerland; e-mail: klaus.blaum@cern.ch  相似文献   

10.
SHIPTRAP is an ion trap facility which is being set up to deliver very clean and cool beams of singly-charged recoil ions produced at the SHIP velocity filter at GSI Darmstadt. SHIPTRAP consists of a gas cell for stopping and thermalizing high-energy recoil ions from SHIP, a rf ion guide for extraction of the ions from the gas cell, a linear rf trap for accumulation and bunching of the ions, and a Penning trap for isobaric purification. The physics programme of the SHIPTRAP facility comprises mass spectrometry, nuclear spectroscopy, laser spectroscopy and chemistry of transeinsteinium elements. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   

11.
A novel Penning-trap tower consisting of five compensated cylindrical Penning traps is developed for the PENTATRAP mass spectrometer at the Max-Planck-Institut für Kernphysik in Heidelberg, Germany. An analytical expression for the electrostatic potential inside the trap tower is derived to calculate standard Penning-trap properties like the compensation of anharmonicities and an orthogonal geometry of the trap electrodes. Since the PENTATRAP project described in the preceding article aims for ultra high-precision mass-ratio measurements of highly charged ions up to uranium, systematic effects for highly charged ions inside the trap tower are considered for the design process as well. Finally, a limit due to remaining anharmonic shifts at large amplitudes is estimated for the resulting geometry, which is important for phase-sensitive measurements of the reduced cyclotron frequency of the ions.  相似文献   

12.
For the determination of the bound-electron g factor in hydrogen-like heavy ions the mass of the ion is needed at a relative uncertainty of at least 1 ppb. With the SMILETRAP Penning trap mass spectrometer at the Manne Siegbahn Laboratory in Stockholm several mass measurements of ions with even-even nuclei at this level of precision have been performed so far, exploiting the fact that the mass precision increases linearly with the ion charge. Measurements of masses of the hydrogen-like ions of the two Mg-isotopes 24Mg and 26Mg are reported. The masses of the hydrogen-like ions are 23.979011054(14) u and 25.976562354(34) u, corresponding to the atomic masses 23.985041690(14) u and 25.982592986(34) u, respectively. The possibility to use these two isotopes for the first observation of an isotope effect in the bound-electron g factor in hydrogen-like heavy ions is discussed.  相似文献   

13.
ISOLTRAP is a Penning trap mass spectrometer for high-precision mass measurements on short-lived nuclides installed at the on-line isotope separator ISOLDE at CERN. The masses of close to 300 radionuclides have been determined up to now. The applicability of Penning trap mass spectrometry to mass measurements of exotic nuclei has been extended considerably at ISOLTRAP by improving and developing this double Penning trap mass spectrometer over the past two decades. The accurate determination of nuclear binding energies far from stability includes nuclei that are produced at rates less than 100 ions/s and with half-lives well below 100ms. The mass-resolving power reaches 107 corresponding to 10keV for medium heavy nuclei and the uncertainty of the resulting mass values has been pushed down to below 10-8. The article describes technical developments achieved since 1996 and the present performance of ISOLTRAP.  相似文献   

14.
15.
16.
The present status and recent results from direct mass measurements of exotic nuclei are presented. ISOL, in-flight, and combined facilities provide a wide variety of nuclides far-off stability covering a wide range of half-lives down to the sub-millisecond region. Modern direct mass measurements are carried out using frequency and time-of-flight techniques. The obtained accurate mass data point to nuclear-structure phenomena and serve as a basis for astrophysical and weak-interaction studies. Received: 21 March 2002 / Accepted: 16 May 2002 / Published online: 31 October 2002 RID="a" ID="a"e-mail: c.scheidenberger@gsi.de  相似文献   

17.
Mass measurements of 34Ar, 73-78Kr, and 74,76Rb were performed with the Penning-trap mass spectrometer ISOLTRAP. Very accurate Q EC-values are needed for the investigations of the t-value of 0+ → 0+ nuclear β-decays used to test the standard model predictions for weak interactions. The necessary accuracy on the Q EC-value requires the mass of mother and daughter nuclei to be measured with δm/m ⩽ 3 . 10-8. For most of the measured nuclides presented here this has been reached. The 34Ar mass has been measured with a relative accuracy of 1.1 . 10-8. The Q EC-value of the 34Ar 0+ → 0+ decay can now be determined with an uncertainty of about 0.01%. Furthermore, 74Rb is the shortest-lived nuclide ever investigated in a Penning trap. Received: 21 March 2002 / Accepted: 16 May 2002 / Published online: 31 October 2002 RID="a" ID="a"e-mail: frank.herfurth@cern.ch  相似文献   

18.
A novel approach to mass measurements at the 10?9 level for short-lived nuclides with half-lives well below one second is presented. It is based on the projection of the radial ion motion in a Penning trap onto a position-sensitive detector. Compared with the presently employed time-of-flight ion-cyclotron-resonance technique, the novel approach is 25-times faster and provides a 40-fold gain in resolving power. Moreover, it offers a substantially higher sensitivity since just two ions are sufficient to determine the ion’s cyclotron frequency. Systematic effects specific to the technique that can change the measured cyclotron frequency are considered in detail. It is shown that the main factors that limit the maximal accuracy and resolving power of the technique are collisions of the stored ions with residual gas in the trap, the temporal instability of the trapping voltage, the anharmonicities of the trapping potential and the uncertainty introduced by the conversion of the cyclotron to magnetron motion.  相似文献   

19.
20.
We summarize our recent 1.5 parts per billion measurement of the antiproton magnetic moment using the multi Penning-trap system of the BASE collaboration. The result was achieved by combining the detection of individual spin-transitions of a single antiproton with a novel two-particle spectroscopy technique, which dramatically improved the data sampling rate. This measurement contributes to improve the test of the fundamental charge, parity, time reversal (CPT) invariance in the baryon sector by a factor of 350 compared to our last measurement, and by a factor of 3000 compared to the best competing measurement. We review the measurement technique and discuss the improved limits on CPT-violating physics imposed by this measurement.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号