首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Uslu  Bengi  &#;zden  Tugba 《Chromatographia》2013,76(21):1487-1494

High efficiency and less elution are the basic requirements of high-speed chromatographic separation. In this study, a new gradient reverse phase chromatographic methods were developed using HPLC and UPLC systems for simultaneous determination of enalapril maleate (ENL) and hydrochlorothiazide (HCZ) in pharmaceutical dosage forms. The chromatographic separations of ENL and HCZ were achieved on a Waters μ-Bondapak C 18, (300 × 3.9 mm, 10 μm) and Waters Acquity BEH C18 (100 × 2.1 mm, 1.7 μm) columns for HPLC within 5.30 min and UPLC within a short retention time of 1.95 min, respectively. A linear response was observed over the concentration range 0.270–399 μg mL−1 of ENL, 0.260–399 μg mL−1 of HCZ for HPLC system and 0.270–399 μg mL−1 of ENL and 0.065–249 μg mL−1 of HCZ for UPLC system. Also, limit of detection for ENL was 1.848 ng mL−1 and 31.477 ng mL−1 for HCZ, 2.804 ng mL−1 for ENL and 2.943 ng mL−1 for HCZ using HPLC and UPLC, respectively. The proposed methods were validated according to ICH guideline with respect to precision, accuracy, and linearity. Forced degradation studies were also performed for both compounds in bulk drug samples to demonstrate the specificity and stability indicating power of the HPLC method. Comparison of system performance with conventional HPLC was made with respect to analysis time, efficiency, and resolution.

  相似文献   

2.
A stability-indicating UPLC method was developed for the simultaneous quantitative determination of losartan potassium, atenolol, and hydrochlorothiazide in pharmaceutical dosage forms in the presence of degradation products. The separation was achieved on a simple isocratic method (water: acetonitrile: triethyl amine: ortho phosphoric acid (60:40:0.1:0.1, v/v) at 0.7 mL min?1, a detection wavelength of 225 nm). The retention times of losartan potassium, atenolol, and hydrochlorothiazide were 2.3, 0.6 and 0.9 min. The total runtime was 3 min. Losartan potassium, atenolol, and hydrochlorothiazide were subjected to different ICH prescribed stress conditions. The method was validated with respect to linearity, accuracy, precision, robustness and ruggedness.  相似文献   

3.
A sensitive, selective and accurate ultra performance liquid chromatographic method has been developed and validated for the simultaneous determination of bisoprolol fumarate and hydrochlorothiazide in their combined dosage forms and as well as in spiked human urine samples. The separation was achieved on an Acquity UPLC BEH C18 1.7 μm (2.1 × 50 mm) column, at 40 °C with mobile phase consisting of acetonitrile:phosphate buffer (20 mM) at pH 3.0 with a gradient elution at 225 nm. Bisoprolol fumarate and hydrochlorothiazide were well separated in <1.5 min with good resolution and without any tailing and interference of excipients. The method was fully validated according to ICH guidelines in terms of accuracy, precision, linearity and specificity. A linear response was observed over the concentration range 0.5–150 μg mL?1 for hydrochlorothiazide and 0.5–250 μg mL?1 for bisoprolol fumarate. Limit of detection and limit of quantitation for hydrochlorothiazide were calculated as 0.01 and 0.03 μg mL?1, respectively, and for bisoprolol fumarate were 0.07 and 0.21 μg mL?1, respectively. Moreover, bisoprolol fumarate and hydrochlorothiazide were subjected to degradation conditions such as hydrolytic, oxidative and thermal stress conditions to evaluate the ability of the proposed method for the separation of bisoprolol fumarate and hydrochlorothiazide from their degradation compounds.  相似文献   

4.
Bari  P. D.  Rote  A. R. 《Chromatographia》2009,69(11):1469-1472

Two new, rapid, precise, accurate and specific chromatographic methods were described for the simultaneous determination of olmesartan medoxomil and hydrochlorothiazide in combined tablet dosage forms. The first method was based on reversed phase liquid chromatography using an Eurosphere 100 RP C18 column (250 × 4.6 mm ID, 5 μm). The mobile phase was methanol–0.05% o-phosphoric acid (60:40 v/v) at a flow rate of 1.0 mL min−1. Commercially available tablets and laboratory mixtures containing both drugs were assayed and detected using a UV detector at 270 nm. The second method involved silica gel 60 F254 high performance thin layer chromatography and densitometric detection at 254 nm using acetonitrile–ethyl acetate–glacial acid (7:3:0.4 v/v/v) as the mobile phase. Calibration curves ranged between 200–600 and 125–375 ng spot−1 for olmesartan and hydrochlorothiazide, respectively.

  相似文献   

5.
P. D. Bari  A. R. Rote 《Chromatographia》2009,69(11-12):1469-1472
Two new, rapid, precise, accurate and specific chromatographic methods were described for the simultaneous determination of olmesartan medoxomil and hydrochlorothiazide in combined tablet dosage forms. The first method was based on reversed phase liquid chromatography using an Eurosphere 100 RP C18 column (250 × 4.6 mm ID, 5 μm). The mobile phase was methanol–0.05% o-phosphoric acid (60:40 v/v) at a flow rate of 1.0 mL min?1. Commercially available tablets and laboratory mixtures containing both drugs were assayed and detected using a UV detector at 270 nm. The second method involved silica gel 60 F254 high performance thin layer chromatography and densitometric detection at 254 nm using acetonitrile–ethyl acetate–glacial acid (7:3:0.4 v/v/v) as the mobile phase. Calibration curves ranged between 200–600 and 125–375 ng spot?1 for olmesartan and hydrochlorothiazide, respectively.  相似文献   

6.
Two simple and sensitive spectrophotometric methods for the determination of cefetamet in either pure form or in its pharmaceutical formulations were described. The method Ⅰ is based on the interaction of 3-methylbenzo[d]- thiazolin-2-one hydrazone (MBTH) with cefetamet in the presence of freshly prepared ferric chloride in a neutral medium. The resulting blue colored product has λmax at 628 nm. The method Ⅱ describes the reduction of ferric ion by the drug to ferrous ion followed by a complex formation reaction with 1,10-phenanthroline (1,10-phen) to form an orange red colored chromogen exhibiting 2max at 510 nm. The products are stable for more than 5 and 8 h respectively. Common excipients used as additives in pharmaceutical preparations do not interfere in the proposed methods. Both methods are highly reproducible and have been applied to a wide variety of pharmaceutical preparations and the results are comparable with those of official methods.  相似文献   

7.
Abstract

A simple, high-pressure liquid chromatographic method for determination of bretylium in pharmaceutical dosage forms is described. The sensitivity of the method is 50 ng with high reproducibility. Exogenous additives from injection, infusion or tablet dosage forms do not interfere with the assay. An increase in the pH of the sample, however, caused a decrease in the peak height of bretylium. Bretylium is a chemically stable compound. Under conditions of either 1.5 N hydrochloric acid, nitric acid, or sodium hydroxide at 25°C and 100°C for a period of up to 48 hours did not influence the outcome of the assay.  相似文献   

8.
《Analytical letters》2012,45(8):1449-1464
Abstract

We developed three methods for the simultaneous determination of amiloride (AMI) and hydrochlorothiazide (HCT): zero-crossing, derivative quotient spectra with normalized divisor and multiple linear regression (MULTIC) methods. The two first methods use the derivative spectrophotometry, and the last one uses the absorbance measurement. The three methods were used to determine both compounds in synthetic mixtures and pharmaceutical preparations with errors less than 5% and 15%, respectively.  相似文献   

9.
Abstract

A reversed-phase, high performance liquid chromatographic method is developed and validated for the simultaneous determination of acetaminophen and hydrocodone bitartrate in pharmaceutical dosage forms. The method employs a Radialpak Cyanopropylsilane Cartridge with a mobile phase containing water, acetonitrile and dibutylamine phosphate (90:10:1). The detection is carried out using a variable wavelength UV-detector set at 215 nm. The acetaminophen showed linearity from 2.0 to 8.0 mg/mL range with a correlation coefficient of 0.999. The hydrocodone bitartrate showed linearity from 0.020 to 0.080 mg/mL range with a correlation coefficient of 0.999. Recoveries for acetaminophen averaged about 100.2% and hydrocodone bitartrate about 102.0% with a standard deviation of about 2.0%. System suitability showed excellent resolution of major peaks. The method is suitable for composite, content uniformity and dissolution assay of capsules and tablets.  相似文献   

10.
A reversed-phase high-performance liquid chromatographic method has been developed and validated for quantitative determination of deflazacort in tablets and in compounded capsules. Isocratic chromatography was performed on a C18 column with acetonitrile–water 80:20 (v/v) as mobile phase at a flow rate of 1.0 mL min?1. UV detection was at 240 nm. The linearity of the method was good (r > 0.999), as also were intra-day and inter-day precision (RSD <2%) and accuracy (recovery >98%). The method was also validated for specificity and robustness. The results showed the proposed method is suitable for its intended use.  相似文献   

11.
12.

A simple, sensitive, selective, precise and stability indicating high-performance thin-layer chromatographic method was developed for the determination of tamsulosin (TAM) in bulk and tablet formulation. Validation was carried out in compliance with International Conference on Harmonization guidelines. The method employed thin-layer chromatography aluminium plates pre-coated with silica gel 60F254 as the stationary phase and the mobile phase consisted of acetonitrile/methanol/dichloromethane (2.0: 1.0: 2.0, v/v/v). This solvent system was found to give compact spots for tamsulosin (R f = 0.27 ± 0.02). Densitometric analysis of TAM was carried out in the absorbance mode at 286 nm. Linear regression analysis showed good linearity (r 2 = 0.9993) with respect to peak area in the concentration range of 300–800 ng per band. The method was validated for precision, accuracy, ruggedness and recovery. Limits of detection and quantitation were 8.49 and 25.72 ng per band, respectively. TAM was subjected to acid and alkali hydrolysis, oxidation, photo degradation, dry heat and wet heat treatment. The drug underwent degradation under acidic, basic and photolytic conditions. The degraded products were well separated from the pure drug. Statistical analysis proved that the developed method, used for quantification of TAM as a bulk drug and present in pharmaceutical tablets, was reproducible and selective.

  相似文献   

13.
Fleroxacin is a third generation fluoroquinolone with broad spectrum antibacterial activity. In this work an LC-DAD method for the analysis of fleroxacin was developed and validated using UV detection at 286 nm. The method was validated for linearity, precision, robustness, LOD, LOQ, specificity and accuracy at concentrations of 0.2–20.0 μg mL−1 and r 2 = 1. The LOD and LOQ were 0.059 and 0.197 μg, respectively, the recoveries were 99.92–102.0% and the CV was less than 2.0%. The LC-DAD validated method provided analytical sensitivity, specificity and reproducibility suitable for quality control analysis.  相似文献   

14.
A simple, sensitive, selective, precise and stability indicating high-performance thin-layer chromatographic method was developed for the determination of tamsulosin (TAM) in bulk and tablet formulation. Validation was carried out in compliance with International Conference on Harmonization guidelines. The method employed thin-layer chromatography aluminium plates pre-coated with silica gel 60F254 as the stationary phase and the mobile phase consisted of acetonitrile/methanol/dichloromethane (2.0: 1.0: 2.0, v/v/v). This solvent system was found to give compact spots for tamsulosin (R f = 0.27 ± 0.02). Densitometric analysis of TAM was carried out in the absorbance mode at 286 nm. Linear regression analysis showed good linearity (r 2 = 0.9993) with respect to peak area in the concentration range of 300–800 ng per band. The method was validated for precision, accuracy, ruggedness and recovery. Limits of detection and quantitation were 8.49 and 25.72 ng per band, respectively. TAM was subjected to acid and alkali hydrolysis, oxidation, photo degradation, dry heat and wet heat treatment. The drug underwent degradation under acidic, basic and photolytic conditions. The degraded products were well separated from the pure drug. Statistical analysis proved that the developed method, used for quantification of TAM as a bulk drug and present in pharmaceutical tablets, was reproducible and selective.  相似文献   

15.
A simple, sensitive, selective, precise and stability-indicating thin-layer chromatographic method for determination of dutasteride both as a bulk drug and as pharmaceutical tablets was developed and validated as per the International Conference on Harmonization guidelines. The method employed thin-layer chromatography aluminium plates precoated with silica gel 60F254 as the stationary phase and the mobile phase consisted of acetonitrile:methanol:dichloromethane in the ratio of 2.0:1.0:2.0, v/v/v. This solvent system was found to give compact spots for dutasteride (R f value of 0.64 ± 0.02). Densitometric analysis of dutasteride was carried out in the absorbance mode at 244 nm. The linear regression analysis data for the calibration plots showed good linear relationship with r = 0.9943 with respect to peak area in the concentration range of 100–600 ng per band. The method was validated for precision, accuracy, ruggedness and recovery. The limits of detection and quantitation were 7.54 and 22.85 ng per band, respectively. Dutasteride was subjected to acid and alkali hydrolysis, oxidation, photo degradation, dry heat and wet heat treatment. The drug undergoes degradation under acidic, basic conditions, photolytic, oxidative and upon wet and dry heat treatment. The degraded products were well separated from the pure drug. The statistical analysis proves that the developed method for quantification of dutasteride as bulk drug and from pharmaceutical tablets is reproducible and selective. As the method could effectively separate the drug from its degradation products, it can be employed as stability-indicating.  相似文献   

16.

Fleroxacin is a third generation fluoroquinolone with broad spectrum antibacterial activity. In this work an LC-DAD method for the analysis of fleroxacin was developed and validated using UV detection at 286 nm. The method was validated for linearity, precision, robustness, LOD, LOQ, specificity and accuracy at concentrations of 0.2–20.0 μg mL−1 and r 2 = 1. The LOD and LOQ were 0.059 and 0.197 μg, respectively, the recoveries were 99.92–102.0% and the CV was less than 2.0%. The LC-DAD validated method provided analytical sensitivity, specificity and reproducibility suitable for quality control analysis.

  相似文献   

17.
Hegazy  Maha A.  Yehia  Ali M.  Mostafa  Azza A. 《Chromatographia》2011,74(11):839-845

Simple, sensitive, selective, precise, and stability-indicating thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC) methods for the determination of mosapride and pantoprazole in pharmaceutical tablets were developed and validated as per the International Conference on Harmonization guidelines. The TLC method employs aluminum TLC plates precoated with silica gel 60F254 as the stationary phase and ethyl acetate/methanol/toluene (4:1:2, v/v/v) as the mobile phase to give compact spots for mosapride (R f 0.73) and pantoprazole (R f 0.45) separated from their degradation products; the chromatogram was scanned at 276 nm. The HPLC method utilizes a C18 column and a mobile phase consisting of acetonitrile/methanol/20 mM ammonium acetate (4:2:4, v/v/v) at a flow rate of 1.0 mL min−1 for the separation of mosapride (t R 11.4) and pantoprazole (t R 4.4) from their degradation products. Quantitation was achieved with UV detection at 280 nm. The same HPLC method was successfully used in performing calibrations in lower concentration ranges for both drugs in human plasma using ezetimibe as internal standard. The methods were validated in terms of accuracy, precision, linearity, limits of detection, and limits of quantification. Mosapride and pantoprazole were exposed to acid hydrolysis and then analyzed by the proposed methods. As the methods could effectively separate the drugs from their degradation products, these techniques can be employed as stability-indicating methods that have been successively applied to pharmaceutical formulations without interference from the excipients. Moreover the HPLC method was successfully used in the determination of both drugs in spiked human plasma.

  相似文献   

18.
Simple, sensitive, selective, precise, and stability-indicating thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC) methods for the determination of mosapride and pantoprazole in pharmaceutical tablets were developed and validated as per the International Conference on Harmonization guidelines. The TLC method employs aluminum TLC plates precoated with silica gel 60F254 as the stationary phase and ethyl acetate/methanol/toluene (4:1:2, v/v/v) as the mobile phase to give compact spots for mosapride (R f 0.73) and pantoprazole (R f 0.45) separated from their degradation products; the chromatogram was scanned at 276 nm. The HPLC method utilizes a C18 column and a mobile phase consisting of acetonitrile/methanol/20 mM ammonium acetate (4:2:4, v/v/v) at a flow rate of 1.0 mL min?1 for the separation of mosapride (t R 11.4) and pantoprazole (t R 4.4) from their degradation products. Quantitation was achieved with UV detection at 280 nm. The same HPLC method was successfully used in performing calibrations in lower concentration ranges for both drugs in human plasma using ezetimibe as internal standard. The methods were validated in terms of accuracy, precision, linearity, limits of detection, and limits of quantification. Mosapride and pantoprazole were exposed to acid hydrolysis and then analyzed by the proposed methods. As the methods could effectively separate the drugs from their degradation products, these techniques can be employed as stability-indicating methods that have been successively applied to pharmaceutical formulations without interference from the excipients. Moreover the HPLC method was successfully used in the determination of both drugs in spiked human plasma.  相似文献   

19.
A simple, rapid, isocratic, stability-indicating reverse phase ultra-performance liquid chromatographic (RP-UPLC) method was developed and validated for the routine analysis of moxonidine in the presence of its degradation products in active pharmaceutical ingredient and pharmaceutical dosage forms. Forced degradation studies were performed according to the guidance of International Conference for Harmonization and were used to evaluate moxonidine intrinsic stability. The drug was subjected to acid, neutral and base hydrolysis as well as to oxidative, thermal and photolytic decomposition in both solution and solid state. The drug appeared to be unstable towards acid and base hydrolysis. To achieve desirable conditions for UPLC analysis, the method development was done with the assistance of experimental design and multivariate optimization methodology by means of Derringer’s desirability function. Stress samples were analyzed according to the experimental plan for fractional factorial screening design and Box-Behnken optimization design. The chromatographic separation was achieved on a C18 Hypersil Gold aq. column (100 mm × 2.1 mm, 1.9 μm) with the mobile phase consisting of methanol–ammonium acetate buffer (10 mM, pH 3.43) mixture (0.9:99.1, v/v) pumped at a flow rate of 870 μL min?1 and detection wavelength of 255 nm. The UPLC–MS and UPLC–MS/MS analyses were further used to characterize the found degradation products. The validation of the proposed method was also performed considering selectivity, linearity, accuracy, precision, limit of detection and limit of quantification, and the results indicated that the method fulfilled all required criteria. The method was successfully applied to the analysis of commercial tablets.  相似文献   

20.
A rapid, simple and accurate spectrophotometric method is developed for the determination of ondansetron hydrochloride in pure and tablet formulations. The method depends on the charge‐transfer complexation between ondansetron base as n‐electron donor with chloranil as π‐acceptor to give a colored complex, which absorbs maximally at 470 nm. Beer's law is obeyed in the concentration ranges 70–980 μg mL?1 with molar absorptivity of 4.47 × 102 L mole?1 cm?1. The proposed method is precise, accurate and specific for the quantitative determination of drug in bulk and tablet formulations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号