首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.

Pharmaceutical analysis based on chromatographic separation is an important part of studies aimed at developing routine quality analysis of drugs. High-performance liquid chromatography (HPLC) is one of the main analytical techniques recommended for drug analysis. Although it meets many criteria vital for analysis, it is time-consuming and uses a relatively high amount of organic solvents compared to other analytical techniques. Recently, Ultra-high-performance liquid chromatography (UHPLC) has been frequently proposed as an alternative to HPLC, which means introducing an environment-friendly approach to drug analysis achieved by reducing the consumption of solvents. It also offers greater chromatographic resolution and higher sensitivity as well as requiring less time due to faster analysis. This review focuses on the basics of UHPLC, compares that technique with HPLC and discusses the possibilities of applying UHPLC for the analysis of different pharmaceuticals and biopharmaceuticals.

  相似文献   

2.
Micellar liquid chromatography (MLC) is an analytical technique belonging to the wide range of reversed-phase liquid chromatographic (RP-LC) separation techniques. MLC with the use of surfactant solutions above its critical micellar concentration (CMC) and the addition of organic modifiers is currently an important analytical tool with still growing theoretical considerations and practical applications in pharmaceutical analysis of drugs and other biologically active compounds. The use of MLC as an alternative, relatively much faster in comparison to conventional chromatographic separation techniques has several advantages, especially as being suitable for screening pharmaceutical analysis. The analytical data received from MLC analysis are considered a useful source of information to predict passive drug absorption, drug transport and other pharmacokinetics and physicochemical measures of pharmaceutical substances.  相似文献   

3.
A general scheme is set up for the estimation of the impurity profile of bulk drug substances by the complex use of chromatographic, spectroscopic and hyphenated techniques. Several examples are presented as illustrations to the scheme from the authors' laboratory involving the use of chromatographic methods such as thin-layer-(TLC), gas-(GC), analytical and preparative high-performance liquid chromatography (HPLC), spectroscopic methods such as mass spectrometry (MS) and NMR spectroscopy as well as hyphenated techniques (HPLC/diode-array UV, GC/MS and HPLC/MS). In addition to summarizing earlier work, new examples are also presented: identification of an impurity (propyl 4-[diethylcarbamoyl(methoxy)]-3-methoxy phenylglyoxylate, II) in propanidid (I) and two unsaturated impurities in allylstrenol (VII) by GC/MS and HPLC/diode-array UV as well as estimation of the impurity profile of mazipredone (III) by HPLC/MS and HPLC/diode-array UV.  相似文献   

4.
The analysis of impurities and degradation products in pharmaceutical preparations are usually performed by chromatographic techniques such as high-performance liquid chromatography (HPLC). This approach demands extensive analysis time, mostly due to extraction and separation phases. These steps must be carried out in samples in order to adapt them to the requirements of the analytical method of choice. In the present contribution, matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) was employed to quantify an important degradation product in atorvastatin calcium 80 mg tablets: the atorvastatin lactone. Through the standard of the impurity, it was possible to perform quantitative analysis directly on the drug tablet, using a quick and novel approach, suitable for quality control processes in the pharmaceutical industry.  相似文献   

5.
This paper demonstrates the analysis of levetiracetam, a new chiral antiepileptic drug, at ng/mL levels using an ultra-high-performance liquid chromatography (UHPLC)-photodiode absorbance (PDA) method. Three different sample preparation methods, liquid-liquid extraction with Extrelut, solid phase extraction (SPE) with Oasis HLB and Oasis MAX SPE cartridges, and protein precipitation with organic solvents were carried out. The last preparatory method is the simplest and provides the best recoveries: between 97.1% and 100.4% with RSD value below 5%. The column for separation is BEH C18 column (1.7 μm particle size and 100 × 2.1 mm i.d.) and acetonitrile-phosphate buffer (pH = 6.6; 0.01 M) (10/90 v/v) is the mobile phase. The results obtained are compared to analysis conducted by the HPLC method. The UHPLC method was validated in the range of 2-100 μg/mL levetiracetam concentration (R(2) = 0.9997). LOD and LOQ are 10 ng/mL and 33 ng/mL, respectively. The developed UHPLC method was applied to plasma samples of patient with epilepsy.  相似文献   

6.
Most phenylthiohydantoin (PTH) amino acids and most methylthiohydantoin (MTH) amino acids may be separated from one another by thin-layer chromatography (TLC) using the same sequential development technique with the same two solvents. Similarly, a single solvent system may be used in high-performance liquid chromatography (HPLC) to separate most PTH-amino acids and most MTH-amino acids. When both TLC and HPLC separations are performed on a sample, all MTH-and PTH-amino acids can be uniquely identified. Since many solid-phase protein sequencing techniques generate both MTH-and PTH-amino acids, these analytical systems simplify identification of the amino acid derivatives. Although the chromatographic properties of MTH-and PTH-amino acids are similar, they are not identical (contrary to a previous report).  相似文献   

7.
Ultra high pressure liquid chromatography (UHPLC) systems operating at very high pressures and using sub-2 microm packing columns have allowed a remarkable decrease in analysis time and increase in peak capacity, sensitivity, and reproducibility compared to conventional HPLC. This technology has rapidly been widely accepted by the analytical community and is being gradually applied to various fields of plant analysis such as QC, profiling and fingerprinting, dereplication, and metabolomics. For many applications, an important improvement of the overall performances has been reported. In this review, the basic principles of UHPLC are summarized, and practical information on the type of columns used and phase chemistry available is provided. An overview of the latest applications to natural product analysis in complex mixtures is given, and the potential and limitations as well as some new trends in the development of UHPLC are discussed.  相似文献   

8.
Captopril (CAP) is an orally active angiotensin-converting enzyme (ACE) inhibitor and has been widely used for management of hypertension and congestive heart failure. CAP lacks an aromatic chromophore required for facile direct UV detection and also has two chiral centers. These factors can render the determination of CAP in complex matrices challenging. This review covers more than 20 years of analytical research on this drug, focusing mainly on pharmaceutical and biological applications. The primary separation techniques discussed are gas chromatography, liquid chromatography, and capillary electrophoresis. The structures of the CAP derivatizing agents as well as a table summarizing various HPLC methods are provided. A discussion of key recent chromatographic and electrophoretic methods for other ACE inhibitors is also present.  相似文献   

9.
The compatibility of liquid chromatography solvents with oxidizing reagents frequently employed in direct chemiluminescence reactions is examined in this study. Various oxidizing reagents were examined for their response in hydro-organic and micellar mobile phases in both isocratic and gradient elution modes. Mild oxidants like hydrogen peroxide, periodate, cerium and hypochlorite were found to be completely compatible with common reversed phase HPLC solvents posing as no threat to the detection procedure. On the other hand, stronger oxidants like acidic permanganate were found to oxidize organic solvents towards the production of an intense light signal. Although several analytical applications can emerge from this finding, the conjunction of this system with reversed phase HPLC is impractical owing to a significant baseline increase which deteriorates the sensitivity of the analysis. A convenient solution to this problem is proposed based on the regulated on-line post-column pre-oxidation of the organic solvent (SPOC) with mild oxidants that have no influence on the final signal. The analytical utility of this new approach in the determination of organic compounds after chromatographic separation is demonstrated.  相似文献   

10.
Post Column derivatisation (PCD) coupled with high performance liquid chromatography or ultra-high performance liquid chromatography is a powerful tool in the modern analytical laboratory, or at least it should be. One drawback with PCD techniques is the extra post-column dead volume due to reaction coils used to enable adequate reaction time and the mixing of reagents which causes peak broadening, hence a loss of separation power. This loss of efficiency is counter-productive to modern HPLC technologies, -such as UHPLC. We reviewed 87 PCD methods published from 2009 to 2014. We restricted our review to methods published between 2009 and 2014, because we were interested in the uptake of PCD methods in UHPLC environments. Our review focused on a range of system parameters including: column dimensions, stationary phase and particle size, as well as the geometry of the reaction loop. The most commonly used column in the methods investigated was not in fact a modern UHPLC version with sub-2-micron, (or even sub-3-micron) particles, but rather, work-house columns, such as, 250 × 4.6 mm i.d. columns packed with 5 μm C18 particles. Reaction loops were varied, even within the same type of analysis, but the majority of methods employed loop systems with volumes greater than 500 μL.  相似文献   

11.
Phenolic compounds represent a class of highly complex naturally occurring molecules that possess a range of beneficial health properties. As a result, considerable attention has been devoted to the analysis of phenolics in a variety of samples. HPLC is the workhorse method for phenolic separation. However, conventional HPLC methods provide insufficient resolving power when faced with the complexity of real-world phenolic fractions. This limitation has been traditionally circumvented by extensive sample fractionation, multiple analysis methods and/or selective detection strategies. On the other hand, there is an increasing demand for improved throughput and resolving power from the chromatographic methods used for phenolic analyses. Fortunately, during the last decade, a number of important technological advances in LC have demonstrated significant gains in terms of both speed and resolution. These include ultra high-pressure liquid chromatography (UHPLC), high-temperature liquid chromatography (HTLC), multi-dimensional separations as well as various new stationary phase chemistries and morphologies. In recent years, these technologies have also found increasing application for phenolic analysis. This review seeks to provide an updated overview of the application of recent advances in HPLC to phenolic separation, with the emphasis on how these methodologies can contribute to improve performance in HPLC analysis of phenolics.  相似文献   

12.
Several recently developed analytical techniques, based on high-end mass spectrometry and chromatography, for dealing with challenges in petroleum characterization are reported. Folded flight path time-of-flight mass spectrometry provides resolving power up to 100000, enabling accurate mass measurement for molecular formula determination with high confidence. Atmospheric pressure chemical ionization (APCI) can be used in both gas chromatography (GC, as APGC) and liquid chromatography (LC) for analyzing non-polar hydrocarbons as well as polar compounds. The improvement in chromatography facilitates the mass spectrometric analysis through online coupling. Comprehensive two-dimensional gas chromatography (GC×GC) resolves overlapping components, rendering accurate identification and quantitation. Supercritical fluid extraction has been developed as an alternative method to replace traditional solvent extraction methods and eliminate the use of large volumes of solvents that can be harmful to health and environment. Supercritical fluid chromatography (SFC) has been developed as a convergence of GC and LC chromatographic techniques. The use of SFC for heavy oils and residua has been demonstrated. Prospective developments in the use of mass spectrometric and chromatographic methods for petroleum characterization are also described.  相似文献   

13.
Comprehensive two-dimensional (2D) chromatographic techniques can be considered innovative methods, only quite recently developed. Since their introduction to the chromatographic community, these techniques have been used in several fields and have gained an excellent reputation as valuable and powerful analytical tools. The revolutionary aspect of comprehensive multidimensional (MD) techniques, in respect to classical MD chromatography, is that the entire sample is subjected to the 2D advantage. The resulting unprecedented separating capacity makes these approaches prime choices when analysts are challenged with highly complex mixtures. Furthermore, in the case of automated systems, instrumental analysis times are roughly the same as in monodimensional applications. The present review reports various comprehensive chromatographic applications on different food matrices. The GC x GC section highlights two fundamental aspects for component separation/identification: the exceptional peak capacity and the formation of group types on the 2D space plane. The LC x LC section reports the employment in food analysis of a recently developed multidimensional normal-phase (NP)-reversed-phase (RP) high performance liquid chromatography (HPLC) system. Also reported are comprehensive LC x GC and packed column supercritical fluid chromatography (pSFC x pSFC) applications in this field.  相似文献   

14.
The evolution of chromatography has led to the reduction in the size of the packing materials used to fabricate HPLC columns. The increase in the backpressure required has led to this technique being referred to as ultrahigh-pressure liquid chromatography (UHPLC) when the column backpressure exceeds 10000 psi (approximately 700 bar). Until recently, columns packed with sub-2-microm materials have generally fitted into two classes; either short (less than 5 cm) columns designed for use on traditional HPLC systems at pressures less than 5000 psi (350 bar), or capillary columns (inner diameters less than 100 microm). By using packing materials with diameters <2 microm to fabricate UHPLC columns, there is an increase in efficiency and a decrease in the analysis time that are directly proportional to the size of the packing material. In order to realize and exploit the increase in efficiency, however, the columns must maintain lengths typically associated with analytical columns (15-25 cm). We have packed 1 mm diameter, 150 mm in length columns with 1.5 microm packing material, and evaluated their performance in UHPLC. The pressure required to achieve optimum linear velocities in plots of plate height versus linear velocity was in the vicinity of 1104 bar (16000 psi). The 1.5 microm particle-packed column was compared with the more traditional 150 mm long analytical columns packed with 3 microm materials. This column showed an efficiency that was approximately twice that observed with the 3 microm packed column and a concomitant reduction in the analysis time, theoretically predicted.  相似文献   

15.
In-process control (IPC) is an important task during chemical syntheses in pharmaceutical industry. Despite the fact that each chemical reaction is unique, the most common analytical technique used for IPC analysis is high performance liquid chromatography (HPLC). Today, the so-called “Quality by Design” (QbD) principle is often being applied rather than “Trial and Error” approach for HPLC method development. The QbD approach requires only for a very few experimental measurements to find the appropriate stationary phase and optimal chromatographic conditions such as the composition of mobile phase, gradient steepness or time (tG), temperature (T), and mobile phase pH. In this study, the applicability of a multifactorial liquid chromatographic optimization software was studied in an extended knowledge space. Using state-of-the-art ultra-high performance liquid chromatography (UHPLC), the analysis time can significantly be shortened. By using UHPLC, it is possible to analyse the composition of the reaction mixture within few minutes. In this work, a mixture of route of synthesis of apixaban was analysed on short narrow bore column (50 × 2.1 mm, packed with sub-2 µm particles) resulting in short analysis time. The aim of the study was to cover a relatively narrow range of method parameters (tG, T, pH) in order to find a robust working point (zone). The results of the virtual (modeled) robustness testing were systematically compared to experimental measurements and Design of Experiments (DoE) based predictions.  相似文献   

16.
Summary: The synthesis and characterization of polyolefins continues to be one of the most important areas for academic and industrial polymer research. One consequence of the development of new “tailor-made” polyolefins is the need for new and improved analytical techniques for the analysis of polyolefins with respect to molar mass and chemical composition distribution. The present article briefly reviews different new and relevant chromatographic techniques for polyolefin analysis. For the fast analysis of the chemical composition distribution of polyolefins a new high-temperature gradient high-performance liquid chromatography (HPLC) system has been introduced. The efficiency of this system for the separation of various olefin copolymers is demonstrated. The correlation between elution volume and chemical composition can be accessed by on-line coupling of high temperature HPLC with FTIR spectroscopy. For the elucidation of the chemical composition as a function of molar mass high-temperature size exclusion chromatography and 1H-NMR spectroscopy can be coupled. It is shown that the on-line NMR analysis of chromatographic fractions yields information on microstructure and chemical composition in addition to molar mass distribution.  相似文献   

17.
As a biological affinity chromatographic method, cell membrane chromatography (CMC) using a silica stationary phase covered with specific cell membrane has been used in screening active components. The innovation of this work is that the bioactive cell membrane and the chromatographic packing are mixed and absorbed for the first time to form the pre-column. The pre-column was placed in front of a C18 column to create dynamic CMC online high-performance liquid chromatography (HPLC) system. The retention behavior and dynamic changes of pharmaceuticals were studied for this system. The results indicate that the retention time of the drug was increased and the symmetry factor reached the analytical level after the addition of the dynamic cell membrane pre-column. Therefore, the dynamic CMC coupled with HPLC system may be a potentially rapid and efficient drug analysis approach for the interaction of drug molecule and receptor on red blood cell membranes.  相似文献   

18.
Throughput for early discovery drug metabolism studies can be increased with the concomitant acquisition of metabolite screening information and quantitative analysis using ultra-fast gradient chromatographic methods. Typical ultra-fast high-performance liquid chromatography (HPLC) parameters used during early discovery pharmacokinetic (PK) studies, for example, employ full-linear gradients over 1-2 min at very high flow rates (1.5-2 mL/min) on very short HPLC columns (2 x 20 mm). These conditions increase sample throughput by reducing analytical run time without sacrificing chromatographic integrity and may be used to analyze samples generated from a variety of in vitro and in vivo studies. This approach allows acquisition of more information about a lead candidate while maintaining rapid analytical turn-around time. Some examples of this approach are discussed in further detail.  相似文献   

19.
This report presents a highly automated procedure for the determination of drug concentrations in plasma samples. The method is generic, in that it has been applied without adaptation to many different drug candidate molecules, but is also flexible, in that variations in the nature and number of samples to be analyzed can be readily accommodated. The method includes preparation of dilutions of analyte stock solutions, spiking these into control plasma to generate analytical standards, and preparation of samples suitable for analysis by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) by precipitation of plasma proteins with acetonitrile, centrifugation, and dilution of the supernatants with HPLC buffer. All of these steps, apart from centrifugation, are performed without manual intervention on an automated liquid-handling workstation using 96-well plates. Analysis is by HPLC/MS/MS, using a generic HPLC gradient. Commercially available software was used for optimization of parameters for analysis by HPLC/MS/MS, integration of chromatographic peaks, and quantification of drug concentrations. The use of this methodology in our laboratory has greatly facilitated the analysis of small sample sets for a large number of analytes, a situation regularly encountered in an early drug discovery environment.  相似文献   

20.
A higher-throughput bioanalytical method based on fast-gradient (1 min run time) high-performance liquid chromatography (HPLC) coupled with tandem mass spectrometry (MS/MS) was developed for screen-type analyses of plasma samples from early drug discovery studies in support of exploratory pharmacodynamic studies. The HPLC system equipped with minibore column was interfaced with either atmospheric pressure chemical ionization (APCI) or electrospray (ESI) ionization techniques. The matrix ion suppression effect of both quantitative HPLC/MS/MS analyses was compared using the post-column infusion system. The use of the described methods provided advantages such as a shorter chromatographic region of ion suppression, less solvent consumption and shorter run times in comparison with standard analytical column HPLC/MS/MS methods. The analytical results obtained by both HPLC/MS/MS methods were in good agreement (within 15% of error) and displayed a good correlation with the pharmacodynamic outcome.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号