首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 875 毫秒
1.
The yeast Saccharomyces cerevisiae was immobilized in cubes of polyurethane foam and the ability of this immobilized material to separate Sb(III) and Sb(V) was investigated. A method based on sequential determination of total Sb (after on-line reduction of Sb(V) to Sb(III) with thiourea) and Sb(III) (after on-line solid–liquid phase extraction) by hydride generation inductively coupled plasma optical emission spectrometry is proposed. A flow system assembled with solenoid valves was used to manage all stages of the process. The effects of pH, sample loading and elution flow rates on solid–liquid phase extraction of Sb(III) were evaluated. Also, the parameters related to on-line pre-reduction (reaction coil and flow rates) were optimized. Detection limits of 0.8 and 0.15 μg L 1 were obtained for total Sb and Sb(III), respectively. The proposed method was applied to the analysis of river water and effluent samples. The results obtained for the determination of total Sb were in agreement with expected values, including the river water Standard Reference Material 1640 certified by the National Institute of Standards and Technology (NIST). Recoveries of Sb(III) and Sb(V) in spiked samples were between 81 ± 19 and 111 ±15% when 120 s of sample loading were used.  相似文献   

2.
An analytical method was developed for antimony speciation and antimony(III) preconcentration in water samples. The method is based on the selective retention of Sb(III) by modified Saccharomyces cerevisiae in the presence of Sb(V). Heat, caustic and solvent pretreatments of the biomass were investigated to improve the kinetics and thermodynamics of Sb(III) uptake process at room temperature. Heating for 30 min at 80 degrees C was defined as the optimal treatment. Antimony accumulation by the cells was independent of pH (5-10) and ionic strength (0.01-0.1 mol L(-1)). 140 mg of yeast and 2h of contact were necessary to ensure quantitative sequestration of Sb(III) up to 750 microg L(-1). In these conditions, Sb(V) was not retained. Sb(V) was quantified in sorption supernatant by inductively coupled plasma mass spectrometry (ICP-MS) or inductively coupled plasma optical emission spectrometry (ICP-OES). Sb(III) was determined after elution with 40 mmol L(-1) thioglycolic acid at pH 10. A preconcentration factor close to nine was achieved for Sb(III) when 100mL of sample was processed. After preconcentration, the detection limits for Sb(III) and Sb(V) were 2 and 5 ng L(-1), respectively, using ICP-MS, 7 and 0.9 microg L(-1) using ICP-OES. The proposed method was successfully applied to the determination of Sb(III) and Sb(V) in spiked river and mineral water samples. The relative standard deviations (n=3) were in the 2-5% range at the tenth microg L(-1) level and less than 10% at the lowest Sb(III) and Sb(V) tested concentration (0.1 microg L(-1)). Corrected recoveries were in all cases close to 100%.  相似文献   

3.
A study was undertaken to ascertain the analytical capabilities of l-methionine immobilized on controlled pore glass for Sb preconcentration and speciation. A fully automated on-line system, implemented with hydride generation (HG) and inductively coupled plasma optical emission spectrometry (ICP OES), was used. Sb(III), at pH 10 was selectively retained in the column containing the immobilized aminoacid, while Sb(V) was not retained at all. A 30% HCl solution was used as eluent agent. Prior to total Sb determination, a pre-reduction step with thiourea was necessary. An on-line pH adjusting and pre-reduction of Sb(V) was achieved in a fully automated system. The detection limit for the preconcentration of 10 mL of an aqueous solution was 70 ng L−1 with a relative standard deviation of 2%. An enrichment factor of 20 was achieved when 10 mL of sample was passed through the system, reaching a throughput of 23 samples per hour. The method was successfully applied to the determination of Sb(III) and total Sb in urine.  相似文献   

4.
A novel absorbent was prepared by dimercaptosuccinic acid chemically modifying mesoporous titanium dioxide and was employed as the micro-column packing material for simultaneous separation/preconcentration of inorganic arsenic and antimony species. It was found that both trivalent and pentavalent of inorganic As and Sb species could be adsorbed quantitatively on dimercaptosuccinic acid modified TiO2 within a pH range of 4–7, and only As(III) and Sb(III) could be quantitatively retained on the micro-column within a pH range of 10–11 while As(V) and Sb(V) were passed through the micro-column without the retention. Based on this fact, a new method of flow injection on-line micro-column separation/preconcentration coupled to inductively coupled plasma optical emission spectrometry was developed for simultaneous speciation of trace inorganic arsenic and antimony in natural waters. Under the optimized conditions, an enrichment factor of 10 and sampling frequency of 10 h− 1 were obtained with on-line mode. The detection limits of As(III), As(V), Sb(III), and Sb(V) are 0.53, 0.49, 0.77 and 0.71 ng mL− 1 for on-line mode and as low as 0.11, 0.10, 0.15 and 0.13 ng mL− 1 for off-line mode due to its higher enrichment factor (50), respectively. The relative standard deviations of two modes are less than 6.7% (C = 20 ng mL− 1, n = 7). The concentration ratio of lower oxidation states/higher oxidation states changing from 1:10 to 10:1 has no obvious effect on the recoveries of As(III) and Sb(III). In order to validate the developed method, two certified reference materials of GSBZ5004-88 and GBW(E)080545 water sample were analyzed and the determined values are in good agreement with the certified values. The proposed method was successfully applied to the simultaneous speciation of inorganic arsenic and antimony in natural waters.  相似文献   

5.
An on-line separation preconcentration system coupled to electrothermal (graphite furnace) atomic absorption spectrometry was developed. A miniature column packed with iminodiacetic acid ethyl cellulose (IDAEC) was inserted into the loop. A peristaltic pump was used to deliver solutions. A flow of air was driven into the packed column, evacuating it between sample loading, washing and elution. The retained analyte was introduced on-line to graphite furnace using countercurrent elution with HNO3. The system was applied for the determination of V, Co and Pb in medicinal mineral water samples, and nickel in sea water samples. The detection limits (3σ) were 0.058, 0.022, 0.067, 0.062 μg/l for Co, Pb, V, and Ni, respectively. The R.S.D. (n=5) was <5% at 0.4–1.0 μg/l concentration range.  相似文献   

6.
On-line system incorporating a microcolumn of Muromac A-1 resin was used for the developing of method for preconcentration of trace elements followed by inductively coupled plasma (ICP) atomic emission spectrometry determination. A chelating type ion exchange resin has been characterized regarding the sorption and subsequent elution of 24 elements, aiming to their preconcentration from water samples of different origins. The effect of column conditioning, pH and flow rate during the preconcentration step, and the nature of the acid medium employed for desorption of the retained elements were investigated. A sample (pH 5) is pumped through the column at 3 ml min−1 and sequentially eluted directly to the ICP with 3 M HNO3/HCl mixtures. In order to remove residual matrix elements from the column after sample loading a short buffer wash was found to be necessary. The effectiveness of the matrix separation process was illustrated. The procedure was validated by analyzing several simple matrices, Standard River water sample as well as artificial seawater. Proposed method can be applied for simultaneous determination of In, Tl, Ti, Y, Cd, Co, Cu and Ni in seawater and for multielement trace analysis of river water. Recovery at 1 μg l−1 level for the determination of investigated 24 elements in pure water ranged from 93.1 to 96% except for Pd (82.2%) and Pb (88.1%). For the same concentration level for seawater analysis recovery was between 81.9 and 95.6% except for Hg (38.2%).  相似文献   

7.
A flow injection on-line sorption preconcentration system has been synchronously coupled to an electrothermal atomic absorption spectrometry (ETAAS) system for the selective determination of trace amounts of Sb(III) in water, soil and plant. The determination was achieved by selective complexation and sorption of Sb(III) with [1,5-bis(2-pyridyl)-3-sulphophenyl methylene thiocarbonohydarzide (PSTH) immobilized on an anion-exchange resin (Dowex 1× 8-200)] at a wide range of pH, quantitative elution with 50 μl of 2 M HNO3 and subsequent ETAAS detection. ETAAS determination of the analyte was performed in parallel with the preconcentration of the next sample. Using a preconcentration time of 60 s and a sample loading flow rate of 2.8 ml min−1, an enhancement factor of 12 was obtained in comparison with direct injection of 50 μl aqueous solution, resulting in a sampling frequency of 31 samples h−1. The detection limit (3 s) was 2 μg l−1 and the precision was 3.1% (R.S.D.) for 11 replicate determinations at 10 μg l−1. The accuracy of the proposed method was demonstrated by analyzing one certified sample and different spiked samples.  相似文献   

8.
Liquid-liquid extraction preconcentration technique which allows the achievement of extremely high ratio between the aqueous and organic phase was specified as semi-microextraction. A modified highly effective liquid phase semi-microextraction (LSME) procedure was developed for preconcentration and determination of ultra trace levels of inorganic antimony species in environmental waters using electrothermal atomic absorption spectrometry (ETAAS) for quantification. Antimony(III) species were selectively extracted as dithiocarbamate complexes from 100 mL aqueous phase into 250 μL xylene at pH range of 5-8. Total Sb was determined using the same extraction system over a sample acidity range of pH 0-1.2 without the need for pre-reduction of Sb(V) to Sb(III). The concentration of Sb(V) was obtained as the difference between that of total antimony and Sb(III). With an 8 min extraction an enrichment factor of 400 was achieved. The limit of detection (3 s) was 2 ng L−1 Sb. The method was not affected by the presence of up to 0.01% humic acid, 0.025 mol L−1 EDTA, 0.01 mol L−1 tartaric acid and 0.001 mol L−1 F. Recoveries of spiked Sb(III) and Sb(V) in river, tap, and sea water samples ranged from 93 to 108%. The results for total antimony concentration in the river water reference material SLRS-5 were in good agreement with the information value. The procedure was applied to the determination and quantification of dissolved antimony species in natural waters.  相似文献   

9.
A new method was developed for the simultaneous speciation of inorganic arsenic and antimony in water by on-line solid-phase extraction coupled with hydride generation-double channel atomic fluorescence spectrometry (HG-DC-AFS). The speciation scheme involved the on-line formation and retention of the ammonium pyrrolidine dithiocarbamate complexes of As(III) and Sb(III) on a single-walled carbon nanotubes packed micro-column, followed by on-line elution and simultaneous detection of As(III) and Sb(III) by HG-DC-AFS; the total As and total Sb were determined by the same protocol after As(V) and Sb(V) were reduced by thiourea, with As(V) and Sb(V) concentrations obtained by subtraction. Various experimental parameters affecting the on-line solid-phase extraction and determination of the analytes species have been investigated in detail. With 180 s preconcentration time, the enrichment factors were found to be 25.4 for As(III) and 24.6 for Sb(III), with the limits of detection (LODs) of 3.8 ng L− 1 for As(III) and 2.1 ng L− 1 for Sb(III). The precisions (RSD) for five replicate measurements of 0.5 μg L−1 of As(III) and 0.2 μg L−1 of Sb(III) were 4.2 and 4.8%, respectively. The developed method was validated by the analysis of standard reference materials (NIST SRM 1640a), and was applied to the speciation of inorganic As and Sb in natural water samples.  相似文献   

10.
A new method for the speciation of inorganic [Sb(III) and Sb(V)] and organic (Me3SbCl2) antimony species by using a polystyrene-divinylbenzene-based anion-exchange HPLC column (Hamilton PRP-X100) coupled to hydride generation atomic fluorescence spectrometry (HG-AFS) is presented. Several mobile phases were tested for the baseline separation of these three antimony species, investigating in detail experimental parameters such as concentration and pH. The best efficiency and resolution was achieved by using a gradient elution between diammonium tartrate 250 mmol l(-1) pH 5.5 (A) and KOH 20 mmol l(-1) pH 12 (B). The gradient programme used was 100% B for 1.5 min, decreasing to 0% B in 0.1 min and maintained the elution with 100% A for 5.5 min. Analysis time was less than 7 min. Equilibration of the column with the complexing mobile phase was found to be critical in order to avoid Sb(III) double peak formation. Dilution in diammonium tartrate medium was necessary in order to avoid Sb(III) oxidation at microg l(-1) concentration level. Detection limits of 0.06 microg l(-1) for Sb(V), 0.09 microg l(-1) for Me3SbCl2 and 0.04 microg l(-1) for Sb(III) as well as repeatability and reproducibility better than 5% R.S.D. (n = 10) and 9% R.S.D. (n = 30) (for 1 and 5 microg l(-1) of Sb(V) and Sb(III) and 5 and 10 microg l(-1) of Me3SbCl2) were obtained. Accuracy and recovery studies were carried out by analysing one river freshwater sample and two water certified reference materials. The proposed methodology can be considered reliable and straightforward for antimony speciation in fresh water samples.  相似文献   

11.
Yu C  Cai Q  Guo ZX  Yang Z  Khoo SB 《The Analyst》2002,127(10):1380-1385
A novel and simple method for inorganic antimony speciation is described based on selective solid phase extraction (SPE) separation of antimony(III) and highly sensitive inductively coupled plasma mass spectrometric (ICP-MS) detection of total antimony and antimony(V) in the aqueous phase of the sample. Non-polar SPE cartridges, such as the Isolute silica-based octyl (C8) sorbent-containing cartridge, selectively retained the Sb(III) complex with ammonium pyrrolidine dithiocarbamate (APDC), while the uncomplexed Sb(V) remained as a free species in the solution and passed through the cartridge. The Sb(III) concentration was calculated as the difference between total antimony and Sb(V) concentrations. The detection limit was 1 ng L(-1) antimony. Factors affecting the separation and detection of antimony species were investigated. Acidification of samples led to partial or complete retention of Sb(V) on C8 cartridge. Foreign ions tending to complex with Sb(III) or APDC did not interfere with the retention behavior of the Sb(III)-APDC complex. This method has been successfully applied to antimony speciation of various types of water samples.  相似文献   

12.
A new modified nanometer SiO2 using 5-sulfosalicylic acid (SSA) as a solid-phase extractant was used for separation, preconcentration and determination of Fe(III) in aqueous solutions by inductively coupled plasma atomic emission spectrometry (ICP-AES). Its adsorption and preconcentration behaviour for Fe(III) in aqueous solutions was investigated using static procedures in detail. The optimum pH value for the separation of Fe(III) on the newly designed sorbent was 3.5. Complete elution of the adsorbed Fe(III) from the nanometer SiO2-SSA was carried out using 2.0 mL of 0.01 mol L− 1 of HCl. The time of 90% sorption was less than 2 min for Fe(III) at pH 3.5. Common coexisting ions did not interfere with the separation and determination of Fe(III) at pH 3.5. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 44.01 mg of Fe(III) per gram of sorbent. The relative standard deviation (RSD) of the method under optimum conditions was 3% (n = 5). The procedure was validated by analyzing three certified reference materials (GBW 08301, GBW 08504, GBW 08511), the results obtained were in good agreement with standard values. The nanometer SiO2-SSA was successfully employed in the separation and preconcentration of the investigated Fe(III) from the biological and natural water samples yielding 100-folds concentration factor.  相似文献   

13.
A quick and reliable analytical method for the separation and quantification of extractable Sb(III) and Sb(V) in atmospheric particulate matter (PM) by ion chromatography(IC)-inductively coupled plasma-mass spectrometry (ICP-MS) has been optimized, validated on pairs of real, equivalent PM10 samples and applied to a field monitoring campaign in a urban site. Both Sb(III) and Sb(V) forms were detected in real samples with Sb(III)/Sb(V) ratios up to 1.5. These two Sb species accounts only for a portion, of variable magnitude, of the total extractable Sb (10–70%); anyway, no other soluble Sb species were detected in the samples. The analysis of size-segregated samples collected by a 13-stage impactor showed that the recovery of [Sb(III) + Sb(V)] versus total extractable Sb is almost quantitative in the coarse fraction while it is below than 10% in the fine fraction. In the extracted solution from particles below 1 μm we could highlight the presence of Sb-containing suspended solid nano-particles, which probably constitute the missing fraction. The contribution of nano-particles can be estimated as the difference between ICP-MS and IC-ICP-MS data, as small size solid bodies are able to pass through the nebulizer and reach the plasma torch, while they are retained by the chromatographic column. The aggregation state of these nano-particles seems to be easily altered when they are suspended in a water solution; a similar behavior could be hypothesized when in contact with biological fluids. It has been confirmed that brake pad abrasion is the prevalent source of Sb(III) in PM and that Sb(V) may be formed by oxidation during the braking processes. Differing from other environmental matrices, there is no evidence of any spontaneous oxidative conversion within the two species.  相似文献   

14.
Solidified floating organic drop microextraction was applied as a separation/preconcentration step prior to the electrothermal atomic absorption spectrometric (ETAAS) determination of ultra trace of antimony species. The method was based on the formation of an extractable complex between Sb(III) and ammonium pyrrolidinedithiocarbamate at pH ~ 5, while Sb(V) was remained in the aqueous phase. The antimony extracted into 1-undecanol was determined by ETAAS. Total antimony was determined after the reduction of Sb(V) to Sb(III) with potassium iodide and ascorbic acid. The amount of Sb(V) was determined from the difference of concentration of total antimony and Sb(III). Under the optimum conditions an enhancement factor of 437.5 and a detection limit of 5.0 ng L?1for the preconcentration of 25 mL of sample was achieved. The relative standard deviation at 300 ng L?1 of antimony was found to be 3.5 % (n = 6). The proposed method was successfully applied to the determination of antimony in tea, basil and natural water samples.  相似文献   

15.
Xiong C  He M  Hu B 《Talanta》2008,76(4):772-779
A new, simple, and selective method has been presented for the separation and preconcentration of inorganic arsenic (As(III)/As(V)) and selenium (Se(IV)/Se(VI)) species by a microcolumn on-line coupled with inductively coupled plasma-optical emission spectrometry (ICP-OES). Trace amounts of As(V) and Se(VI) species were separated and preconcentrated from total As and Se at desired pH values by a conical microcolumn packed with cetyltrimethylammonium bromide (CTAB)-modified alkyl silica sorbent in the absence of chelating reagent. The species adsorbed by CTAB-modified alkyl silica sorbent were quantitatively desorbed with 0.10 ml of 1.0 mol l−1 HNO3. Total inorganic arsenic and selenium were similarly extracted after oxidation of As(III) and Se(IV) to As(V) and Se(VI) with KMnO4 (50.0 μmol l−1). The assay of As(III) and Se(IV) were based on subtracting As(V) and Se(VI) from total As and total Se, respectively. All parameters affecting the separation/preconcentration of As(V) and Se(VI) including pH, sample flow rate and volume, eluent solution and volume have been studied. With a sample volume of 3.0 ml, the sample throughput was 24 h−1 and the enrichment factors for As(V) and Se(VI) were 26.7 and 27.6, respectively. The limits of detection (LODs) were 0.15 μg l−1 for As(V) and 0.10 μg l−1 for Se(VI). The relative standard deviations (RSDs) for nine replicate determinations at 5.0 μg l−1 level of As(V) and Se(VI) were 4.0% and 3.6%, respectively. The calibration graphs of the method for As(V) and Se(VI) were linear in the range of 0.5–1000.0 μg l−1 with a correlation coefficient of 0.9936 and 0.9992, respectively. The developed method was successfully applied to the speciation analysis of inorganic arsenic and selenium in natural water samples with satisfactory results.  相似文献   

16.
A separation procedure for antimony(III) and antimony(V) was developed with the use of chelating celluloses. Sb(III) was separately pre-concentrated on imino diacetic acid–ethyl cellulose in the acidic pH range, in which the uptake of Sb(V) was negligible in the μg L− 1 concentration range. On the other hand, both Sb species Sb(V) and Sb(III) were pre-concentrated on a chloride form of 2,2′-diaminodiethylamine-cellulose. These solid phase extraction procedures were combined with graphite furnace atomic absorption spectrometry (SPE–GFAAS) for Sb detection. Pharmaceutical compounds of organic and inorganic types (ten compounds), as well as mineral water samples (twelve types) were analyzed. Detection limits of 0.18 µg L− 1 Sb(III) and 0.25 µg L− 1 Sb(V) were found in aqueous sample solutions and water samples, respectively, considering a 25-fold pre-concentration. The total Sb, mostly in the form of Sb(V), could be determined in phosphate-containing pharmaceuticals, while in phosphoric acid, Sb(III) was the dominant form. In all other types of samples the Sb content was below the detection threshold, and therefore, the potential suitability of the SPE–GFAAS method for the determination of Sb(III) species was proven by recovery tests of spiked samples. This method ensures the required detection power with regard to the allowable Sb limits established by international organizations.  相似文献   

17.
Antimony is a common contaminant at abandoned sites for non-ferrous ore mining and processing. Because of the possible risk of antimony by transfer to plants growing on contaminated sites, it is of importance to analyze antimony and its species in such biota. A method based on high performance liquid chromatographic separation and inductively coupled plasma mass spectrometric detection (HPLC-ICP-MS) was developed to determine inorganic antimony species such as Sb(III) and Sb(V) as well as possible antimony-organic metabolisation products of the antimony transferred into plant material within one chromatographic run. The separation is performed using anion chromatography on a strong anion exchange column (IonPac AS15/AG 15). Based on isocratic optimizations for the separation of Sb(III) and Sb(V) as well as Sb(V) and trimenthylated Sb(V) (TMSb(V)), a chromatographic method with an eluent gradient was developed. The suggested analytical method was applied to aqueous extracts of Chinese break fern Pteris vittata samples. The transfer of antimony from spiked soil composites into the fern, which is known as a hyperaccumulator for arsenic, was investigated under greenhouse conditions. Remarkable amounts of antimony were transferred into roots and leaves of P. vittata growing on spiked soil composites. Generally, P. vittata accumulates not only arsenic (as shown in a multiplicity of studies in the last decade), but also antimony to a lower extent. The main contaminant in the extracts was Sb(V), but also elevated concentrations of Sb(III) and TMSb(V) (all in μg L−1 range). An unidentified Sb compound in the plant extracts was detected, which slightly differ in elution time from TMSb(V).  相似文献   

18.
A sensitive and simple method for flame atomic absorption spectrometry (FAAS) determination of antimony species after separation/preconcentration by cloud point extraction (CPE) has been developed. When the system temperature is higher than the cloud point extraction temperature, the complex of antimony (III) with N-benzoyl-N-phenyhydroxylamine (BPHA) can enter the surfactant-rich phase, whereas the antimony (V) remains in the aqueous phase. Antimony (III) in surfactant-rich phase was analyzed by FAAS and antimony (V) was calculated by subtracting of antimony (III) from the total antimony after reducing antimony (V) to antimony (III) by L-cysteine. The main factors affecting the cloud point extraction, such as pH, concentration of BPHA and Triton X-114, equilibration temperature and time, were investigated systematically. Under optimized conditions, the detection limits (3σ) were 1.82 ng mL−1 for Sb(III) and 2.08 ng mL−1 for Sb(total), and the relative standard deviations (RSDs) were 2.6% for Sb(III) and 2.2% for Sb(total). The proposed method was applied to the speciation of antimony species in artificial seawater and wastewater, and recoveries in the range of 95.3–106% were obtained by spiking real samples. This technique was validated by means of reference water materials and gave good agreement with certified values.  相似文献   

19.
A sensitive, precise and automated non-chromatographic method for Sb(III) and Sb(V) analytical speciation based on a continuous tandem on-line separation device in connection with inductively coupled plasma-atomic emission (ICP-AES) detection is proposed. Two on-line successive separation steps are included into this method: a continuous liquid-liquid extraction of Sb(III) with ammonium pyrrolidine dithiocarbamate (APDC) into methylisobuthylketone (MIBK), followed by direct stibine generation from the organic phase. Both separation steps are carried out in a continuous mode and on-line with the ICP-AES detector. Optimization of experimental conditions for the tandem separation and ICP-AES detection are investigated in detail. Detection limits for Sb(III) were 3 ng.mL–1 and for Sb(V) 8 ng.mL–1. Precisions observed are in the range ± 5%. The proposed methodology has been applied to Sb(III) and Sb(V) speciation in sea-water samples.  相似文献   

20.
Antimony(V) is volatilized by reaction with potassium bromide in concentrated sulfuric acid media. After volatilization, the gases can be transported to an inductively coupled plasma spectrometer for atomic emission of antimony and its analytical determination. The influent factors, concentrated sulfuric acid volume, concentration and volume of the potassium bromide aqueous solution and carrier gas flow were investigated and optimized using different alternatives. A detection limit of 48 ng ml−1 of Sb was achieved under the optimized conditions with a precision of 7.6% and the calibration graph was linear from 0.10 to 10.0 μg ml−1 for a sample injection of 130 μl.The study of interferences from common cations and anions revealed a good tolerance for most ions, although there was a significant improvement in Sb(V) volatility when As(III) was present. Furthermore, the As(III) sensitization was only produced with Sb(V) species, while the volatility of the Sb(III) bromide species was unaltered.The method was applied to the determination of Sb in real river waters. The results were checked using alternative atomic spectroscopy methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号