首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Summary A method has been developed for the determination of very low concentrations (pg/m3) of organic chlorinated compounds in air. Chlorinated benzenes, hexachlorocyclohexanes, polychlorinated biphenyls and the DDT group. Since most of the atmospheric burden of such compounds occurs in the gas phase, a high volume sampling method has been developed using carefully precleaned polyurethane foam as collection medium. Samples of 2000–4000 m3 were taken at different sites in the Arctic. The foam quality as well as the precleaning procedure of the foam and the clean-up of the sample are described in detail. The recovery of both the extraction and sample pretreatment was in the range of 80–115% for nanogram amounts. Sampling efficiency for the first foam plug was 80–100%.The sampling efficiency is influenced by different factors (temperature, air humidity, sampling volume). For quantification and identification, the highly selective methods of negative ion chemical ionization mass spectrometry and electron capture detection were combined with high resolution gas chromatography. The detection limit of the method was for most compounds less than a few pg/m3. Some preliminary data from the Arctic measurements are presented and are briefly discussed.
Quantitative Bestimmung von Ultraspuren chlorierter Verbindungen in großvolumigen Luftproben aus der Arktis mit Hilfe von Polyurethanschaum als Sammelmedium
Zusammenfassung Das beschriebene Verfahren dient zur Bestimmung von chlorierten Verbindungen (chlorierte Benzole, Hexachlorcyclohexane, polychlorierte Biphenyle, DDT-Gruppe) in niedrigen Konzentrationen (pg/m3) in Luft. Da die meisten dieser Verbindungen gasförmig vorkommen, wurde eine Probenahmemethode für große Volumina unter Verwendung von sorgfältig vorgereinigtem Polyurethanschaum als Adsorptionsmedium entwickelt. Proben von 2000–4000 m3 wurden an verschiedenen Stellen der Arktis genommen. Die Vorbehandlung des Schaums und der Probe wird ausführlich beschrieben. Bei ng-Mengen lag die Wiederfindung bei 80–115%. Die Leistungsfähigkeit der ersten Schaumschicht lag bei 80–100%. Durch Temperatur, Luftfeuchtigkeit und Probenahmevolumen wird die Leistungsfähigkeit beeinflußt. Zur Identifizierung und quantitativen Bestimmung wurde die Negativionen-Massenspektrometrie mit chemischer Ionisation und die EC-Detektion mit der Hochleistungs-Gas-Chromatographie kombiniert. Die Nachweisgrenze lag für die meisten Verbindungen bei weniger als einigen pg/m3. Einige Daten der arktischen Messungen werden vorgestellt und kurz diskutiert.


Partly presented at the Fourth European Conference on Analytical Chemistry, Helsinki/Espoo, Finland 1981  相似文献   

2.
The thermal properties of organic compounds intended to be applied as latent cold storage substances were investigated by methods of analysis according to Tammann, and by DTA and DSC. Findings were made concerning the melting and solidification behaviour, subcooling, specific melting enthalpies and specific heat capacities of paraffin mixtures, low and high-molecular glycols, ethylenediamine hydrates and formamide. Ethylenediamines and ethylene glycol, with high storage densities of 200–300 MJ·m–3, appear to be promising cold storage substances if subcooling is reduced. Through the use of congruently melting low-molecular glycols and formamide, storage densities of about 170 MJ·m–3 are obtained. Paraffin mixtures and high-molecular glycols melt in wide ranges of temperatures and give values of about 100 MJ·m–3, which are not relevant to cold storage units.
Zusammenfassung Mittels DTA, DSC und dem Analysenverfahren von Tammann wurden die thermischen Eigenschaften von organischen Substanzen untersucht, die als Kältespeichersubstanzen verwendet werden sollen. Dabei wurden Aussagen bezüglich des Schmelz- und Erstarrungsverhaltens, der Unterkühlung, der spezifischen Schmelzenthalpien und spezifischen Wärmekapazitäten von Paraffingemischen, nieder- und hochmolekularen Glykolen, Ethylendiaminhydraten und von Formamid getroffen. Ethylendiamine und Ethylenglykole mit einer hohen Speicherkapazität von 200–300 MJ·m–3 scheinen gute Kältespeicherstoffe zu sein, wenn die Unterkühlung unterbunden wird. Bei der Verwendung von kongruent schmelzenden niedermolekularen Glykolen und von Formamid wurden Speicherkapazitäten von 170 MJ·m–3 erreicht. Paraffingemische und hochmolekulare Glykole schmelzen in einem weiten Temperaturbereich und sind mit einer Speicherkapazität von 100 MJ·m–3 für Kühlbatterien ungeeignet.
  相似文献   

3.
Summary Ambient concentrations of organic pollutants in various environmental compartments are largely determined by the compounds' fate and their release rate. The change of such concentrations with time can be followed by a variety of monitoring programs. In addition to the traditional chemical analysis methods this paper discusses the use of combinations of chemical analyses with biological tests.
Umweltprozesse und Überwachung von organischen Mikroverunreinigungen
Zusammenfassung Die Konzentrationen von organischen Verunreinigungen in den verschiedenen Bereichen der Umwelt werden weitgehend bestimmt von dem Verhalten der Verbindungen und der Geschwindigkeit der Freisetzung. Die Konzentrationsveränderungen mit der Zeit können mit Hilfe verschiedener Überwachungsprogramme verfolgt werden. Zusätzlich zu den üblichen chemisch-analytischen Verfahren werden Kombinationen von chemischer Analytik und biologischen Tests diskutiert.
  相似文献   

4.
Summary General aspects of chemical enhancement of sensitivity are discussed. Experimental results for the reaction of HCl with organic compounds and a gas chromatographic separation of the products with electron-capture detection, are given. The reaction of HCl with99m TcO3 and the formation of TcO3Cl is discussed.
Zusammenfassung Allgemeine Gesichtspunkte der Empfindlichkeitssteigerung auf chemischem Wege wurden besprochen. Experimentelle Ergebnisse der Reaktion von Chlorwasserstoff mit organischen Verbindungen und eine gaschromatographische Trennung der Reaktionsprodukte sowie deren Nachweis durch EC-Detektoren wurden beschrieben. Die Reaktion von HC1 mit99m TcO3 und die Bildung von TcO3Cl wurde besprochen.
  相似文献   

5.
Summary The solid state ion-selective chloride and bromide electrodes are used for the microdetermination of chlorine and bromine in organic compounds. After combustion in an oxygen-filled flask, potentiometric titration with silver nitrate at pH 5–7 in presence of 50% dioxan is carried out. Results accurate to ±0.3% absolute are obtained with some partially and highly halogenated compounds.
Mikrobestimmung von Chlor und Brom in einigen organischen Verbindungen mit Hilfe von ionenselektiven Elektroden
Zusammenfassung Chlorid- und bromidselektive Festkörperelektroden wurden zur Chlor- und Brombestimmung in teilweise bzw. hochhalogenierten organischen Verbindungen benutzt. Nach Verbrennung im Sauerstoffkolben erfolgt eine potentiometrische Titration mit Silbernitrat bei pH 5–7 in Gegenwart von 50% Dioxan. Die erhaltenen Ergebnisse sind auf ±0,3 % genau.
  相似文献   

6.
Zusammenfassung Die Bestimmung von Helium wird an der Schnüffelsonde eines Lecksuchgerätes ausgeführt. Zwischen 10% und 10–4% He ist die Anzeige fast linear mit einem Fehlerfaktor von 10±0,15. Die Analyse von Luft und Naturgas ist rasch durchführbar.
Determination of Helium in natural gases with a Leah-detector
Summary The determination of Helium is made with a Leak-detector by the shifting valve. Between 10% and 10–4% Ho the record is nearly linear, with an errorfactor of 10±0,15. It is easily possible to analyze air and natural gases.
  相似文献   

7.
Summary To identify and determine amounts above 10–10 mole of such substances as thiols, dithiocarbamates and thioureas in organic solvents, the use of an alcoholic solution of tetramercurated fluorescein (TMF) with oxine or prominal has been suggested. The determination is based on the displacement of oxine or prominal from their complexes with TMF and recording the change in fluorescence. The fluorescence of TMF complexes relative to the prominal complex as reference has been established for aqueous and organic solvent media. Fluorimetric titration with TMF-oxine and TMF-prominal is illustrated by determination of butanethiol in chloroform and thiomalic acid in hexanol.
Zusammenfassung Zum Nachweis und zur Bestimmung von Thiolen, Dithiocarbamaten, Thioharnstoffderivaten und ähnlichen Verbindungen in organischen Lösungsmitteln wird die Verwendung einer alkoholischen Lösung von tetramercuriertem Fluoreszein (TMF) mit Oxin bzw. mit Prominal vorgeschlagen. Die Bestimmung beruht auf der durch Dekomplexierung verursachten Fluoreszenzänderung. Die Fluoreszenz von TMF-Komplexen wurde mit der von Prominalkomplexen in Wasser und in organischen Lösungsmitteln verglichen. Als Beispiel für fluorimetrische Titrationen mit TMF—Oxin wurde die Bestimmung von Butanthiol in Chloroform, für die Titration mit TMF—Prominal die Bestimmung von Thioäpfelsäure in Hexanol beschrieben. Der Schnittpunkt zweier Geraden zeigt den Endpunkt an.
  相似文献   

8.
Zusammenfassung Es wird eine Methode beschrieben, die routinemäßig die Trennung und Identifizierung organischer Verunreinigungen im Konzentrationsbereich 10–4 bis 10–8 Vol.-% ermöglicht. Die Anreicherung der Komponenten erfolgt mit einem Mikrogradientenrohr, die Trennung an Glas-Dünnfilmkapillaren mit linearprogrammierter Tieftemperatur-Gas-Chromatographie (LTGC), die Identifizierung mit einem angekoppelten Massenspektrometer. Auswertbare Massenspek tren werden noch bei Substanzkonzentrationen von 0,02 ppb*) erreicht. Für die Analyse können handelsübliche Geräte verwendet werden.
Investigation of volatile organic micropollutants in air and water using low-temperature capillary GC-MS
Summary This paper describes a method which allows routine separation and identification of organic micropollutants within a concentration range 10–4 to 10–8% by volume. Enrichment of the components occurs in a microgradient tube, separation on glass-thin film open tubular columns by linear-programmed low-temperature gas chromatography (LTGC) and identification by a mass spectrometer coupled to it. Evaluable mass-spectra are obtained for concentrations as low as 0,02 ppb*). Analyses can be performed on commercial equipment.
  相似文献   

9.
Zusammenfassung n-Butylzinnverbindungen (Tetra-, Tri-, Di-) wurden aus der angesaugten Luft an Chromosorb 102 adsorbiert, mit HCl-haltigem Diethylether desorbiert, falls nötig mit Methylmagnesiumchlorid umgesetzt und die methylierten Verbindungen gas-chromatographisch mit einem zinnspezifischen flammenphotometrischen Detektor bestimmt. Die mittlere Wiederfindungsrate (0,09–40 g) von Bis(tri-n-butylzinn)oxid (TBTO) betrug: 93,3%; Streubereich der Einzelwerte ± 9,3% (P=95%, N=11). Wird 1 m3 Luft angesaugt, lassen sich noch Konzentrationen an n-Butylzinnverbindungen (Tetra-, Tri-, Di-) von 0,05 g/m3 bestimmen.In einem mit einer TBTO-haltigen Dispersionsfarbe gestrichenen Raum wurde die Temperaturabhängigkeit der Tri-n-butylzinn-Konzentration in der Luft untersucht. Der Vergleich mit den Resultaten von Bestimmungen des Totalzinngehaltes läßt den Schluß zu, daß in der Luft nur Tri-n-butylzinnverbindungen vorlagen.
GLC-determination of traces of n-butyltin compounds (tetra-, tri-, di-) in the air
Summary n-Butyltin compounds (tetra-, tri-, di-) have been adsorbed on Chromosorb 102 from the aspired air, desorbed with HCl-containing diethylether and, if necessary, converted to the corresponding methyl derivatives by reaction with methylmagnesium chloride. The derivatives were determined by GLC with a tin-specific flame photometric detector. The mean recovery (0.09–40 g) of bis(tri-n-butyltin)oxide (TBTO) was 93.3%; tolerance limit ±9.3% (P=95%, N=11). With an air sample of 1 m3 it is possible to measure n-butyltin compounds (tetra-, tri-, di-) in concentrations down to 0.05 g/m3.In a room coated with a TBTO-containing latex-based paint, the temperature dependence of the tri-n-butyltin concentration in the air has been studied. Comparison with results of total tin determinations allows the conclusion that the air contained only tri-n-butyltin compounds.
  相似文献   

10.
Summary Formaldehyde collection efficiency from air and its determination by DC and DP polarography and linear sweep voltammetry at mercury electrode in basic and acidic solutions are scrutinized. Some statements from older literature about this subject are found to be too conservative. The experimental conditions and reliable procedure for formaldehyde sampling from air, standardization and determination from solution using polarographic and related techniques are presented. Detection limits of formaldehyde determination by these techniques are estimated.
Bestimmung von Formaldehyd in Luft mittels differentieller Puls-Polarographie und ähnlichen Verfahren
Zusammenfassung Die Anreicherung von Formaldehyd aus Luft und dessen Bestimmung mittels DC-und DP-Polarographie sowie mittels linearer Voltammetrie an der Quecksilber-Elektrode in basischem und saurem Milieu wurde eingehend geprüft. Gewisse Feststellungen in der älteren Literatur erwiesen sich als ungeeignet. Die experimentellen Voraussetzungen zur Probenahme, die Standardisierung und Bestimmung aus Lösung mit Hilfe polarographischer und ähnlicher Verfahren wurden angegeben. Die Nachweisgrenzen wurden ermittelt.
  相似文献   

11.
Zusammenfassung Die bleisensitive Elektrode der Fa. Orion spricht neben Bleiionen auch auf Sulfationen an. Dies ermöglicht die potentiometrische Titration von Sulfat mit Bariumperchlorat sowie die Titration von Barium und Strontium mit Natriumsulfat. Der günstigste pH-Bereich liegt zwischen 5 und 7. Titriermedium sind Dioxan-Wasser-Gemische. Die Verfahren sind sehr empfindlich und erlauben in allen Fällen die Titration bis herab zu 5·10–4 mMol.Anwendungsbeispiele für die Bestimmung von Schwefel in organischen Verbindungen nach Schöniger- oder Wickbold-Verbrennung sind angegeben.
Potentiometric titration of sulphate, barium and strontium by means of a lead-sensitive electrode
The Orion lead electrode was found to be responsive not only to lead ions but to sulphate ions, too. This offers possibilities to titrate sulphate with barium perchlorate and reversely barium and strontium with sodium sulphate. The useful pH range is 5–7. Dioxan-water mixtures serve as solvents. The described methods are highly sensitive and allow determinations down to 5×10–4 millimoles.Examples are given for the determination of sulphur in organic samples after combustion according to Schöniger or Wickbold.
  相似文献   

12.
Summary A method is described for determining the plutonium concentration by Isotope Dilution Alpha Spectrometry (IDAS) using238Pu as a spike. It involves the addition of a pre-calibrated spike solution to a known aliquot of the plutonium sample solution followed by source preparation using TEG as a spreading agent. The results obtained on a number of samples using this method are compared with those of IDMS using242Pu as a spike as well as with those obtained by IDAS using TTA for purification, with respect to precision and accuracy. Precision of 0.3–0.5% and an accuracy of 0.5% is demonstrated. This method eliminates the need of any separation and purification of plutonium from241 Am and a bulk of other impurities.
Plutoniumbestimmung durch Isotopenverdünnungs-Alpha-Spektrometrie ohne Abtrennung von Americium-241 und anderen Verunreinigungen
Zusammenfassung Bei dem beschriebenen Verfahren der Isotopenverdünnungs-Alpha-Spektrometrie (IDAS) wird238Pu als Spike benutzt. Eine vorgeeichte Spike-Lösung wird zu einem bekannten Aliquot der Probe gegeben und anschließend die Strahlungsquelle unter Verwendung von Tetraethylenglykol als Spreading-Reagens vorbereitet. Die nach diesem Verfahren erhaltenen Ergebnisse werden in bezug auf Präzision und Genauigkeit mit solchen verglichen, die mit Isotopenverdünnungs-Massenspektrometrie unter Verwendung von242Pu als Spike oder mit IDAS unter Verwendung von Thenoyltrifluoraceton zur Reinigung erhalten wurden. Eine Präzision von 0,3–0,5% und eine Genauigkeit von 0,5% wurden erzielt. Durch das beschriebene Verfahren erübrigt sich eine Reinigung des Pu von241Am und anderen Verunreinigungen.
  相似文献   

13.
Zusammenfassung Ein mit der Voranreicherung mit Triphenylchlormethan kombiniertes spektrographisches Verfahren zur quantitativen Bestimmung des Spurenelements Bor im Bereich von 1 · 10–9 bis 1 · 10–5 g B/g in Siliciumtetrachlorid und Silicochloroform wird mitgeteilt.Die Wirkung der Atmosphäre auf die Intensität der Linien von Bor wurde untersucht. Die Vorteile des Arbeitens in Luft wurden ausgenutzt und mit Hilfe der koinzidierenden SiO-Linien eine einfache Berechnungsmethode angegeben. Zwei Verfahren zur Herstellung von Standardserien wurden entwickelt.
Summary A spectrographic method combined with triphenylchloromethane pre-enrichment is recommended which is suitable for the determination of boron trace-impurities in SiCl4(GeCl4) and SiHCl3 ranging from 1 · 10–9 to 1 · 10–5 g B/g.The effect of the atmosphere on the intensity of the boron line was examined; a simple method is reported for taking into consideration the influence of the coincident SiO line utilising the advantage of excitation in the air-atmosphere. Two reliable standard-methods are discussed.


Die Verfasser sprechen Frau E. Sztankó für ihre Hilfe bei den Messungen ihren aufrichtigen Dank aus.  相似文献   

14.
Summary The influence of X-ray radiation on samples of organic binders (starch, graphite and cellulose) and briquetted samples of sinter and sinter mixture of blast furnace charge was examined. The time of irradiation by the primary X-ray beam was from 0 to 300 min. The usability of standard and reference samples, which are formed into briquettes with organic binders, depends upon the resistance of the binder to irradiation.
Einfluß der Bestrahlungsdauer auf die Verwendbarkeit von brikettierten Proben in der Röntgenfluorescenz-Spektrometrie
Zusammenfassung Der Einfluß von Röntgenbestrahlung auf Proben der organischen Bindemittel Stärke, Graphit und Cellulose sowie auf brikettierte Sinter- und Sintermischungsproben aus Hochofenbeschickung wurde untersucht. Die Bestrahlungsdauer betrug 0–300 min. Die Verwendbarkeit der mit organischen Bindemitteln brikettierten Standard- und Vergleichsproben hängt von der Widerstandsfähigkeit der Bindemittel gegen die Bestrahlung ab.
  相似文献   

15.
Summary Light-induced transformations of organic chemicals have been studied to provide kinetic results concerning the influence of sunlight on pollutant behavior in lakes and rivers. A review of these studies shows that the humus component of the dissolved organic matter in natural water affects aquatic photoreactions in two important ways: by attenuating sunlight and by sensitizing photoreactions. Studies of humus-sensitized photoreactions of furans, sulfides, dienes, nitroaromatic compounds, and other chemicals are discussed. Research concerning effects of aquatic particulates on pollutant photoreaction rates are reviewed. Suspended sediments mainly affect photolysis rates through light attenuation and scattering. Algae, diatoms, and bacteria accelerate light-induced transformations of anilines and phosphorothioate insecticides, suggesting that photobiological processes may play a significant role in the breakdown of certain pollutants in aquatic environments. Evidence is presented that nitrate, iron species, and peroxides may be responsible for sunlight-initiated free radical oxidations of pollutants in some natural waters.
Dynamik der Photoreaktionen von Verunreinigungen in der Hydrosphäre
Zusammenfassung Um kinetische Daten über den Einfluß von Sonnenlicht auf das Verhalten von Verunreinigungen in Seen und Flüssen zu erhalten, wurden licht-induzierte Umwandlungsreaktionen von organischen Chemikalien untersucht. Es ergab sich, daß die Humuskomponente der in natürlichen Wässern gelösten organischen Substanzen auf zwei Arten die aquatischen Photoreaktionen beeinflußt. durch Schwächung des Sonnenlichtes und durch Sensibilisierung der Photoreaktionen. Humus-sensibilisierte Photoreaktionen von Furanen, Sulfiden, Dienen, nitroaromatischen Verbindungen u.a. werden diskutiert. Ein Überblick wird gegeben über die Wirkung aquatischer Partikel auf die Geschwindigkeit der Photoreaktion von Verunreinigungen. Suspendierte Sedimente wirken hauptsächlich durch Lichtabschwächung und Streuung auf die Photolysegeschwindigkeit. Algen, Diatomeen und Bakterien beschleunigen lichtinduzierte Umwandlungen von Anilinen und Phosphorthioat-Insecticiden, was darauf hindeutet, daß photobiologische Prozesse eine bedeutende Rolle beim Abbau gewisser Verunreinigungen in aquatischer Umgebung spielen könnten. Es wird gezeigt, daß Nitrat, Eisenverbindungen und Peroxide für die Sonnenlicht-induzierte Oxidation freier Radikale von Verunreinigungen in natürlichen Wässern verantwortlich sein können.
  相似文献   

16.
Summary The possibility of specific removal of carbon monoxide from a stream of air in the presence of vapours of volatile organic compounds was investigated. Weighed samples of oxalic acid were pyrolyzed to obtain standard mixtures of CO with air. Carbon monoxide present in the stream of air (at the flow rate of 700 cm3/ min) is quantitatively oxidized to CO2 by a layer of the Körbl catalyst (diameter=12 mm, length=35 mm) heated to 90° C. The CO2 formed can be specifically bound by a heated layer of ascarite46. On the basis of model experiments it was concluded that under the conditions described in the paper the degree of oxidation of 16 various organic compounds ranged from 0.7 to 8.7%. Thus, the developed method can be applied as a mean of practically specific removal of CO from a stream of analyzed air in the course of determination of total organic carbon (TOC).
Zusammenfassung Die Möglichkeit einer spezifischen Entfernung von Kohlenoxid neben Dämpfen flüchtiger, organischer Verbindungen aus dem Luftstrom wurde untersucht. Zur Herstellung von CO-Luftstandardgemischen dienten gewogene Mengen Oxalsäure, die thermisch zersetzt wurden. Das im Luftstrom (700 cm3/Minute) anwesende CO wird an einer auf 90° C erhitzten Körblkatalysatorschicht von 35 mm Länge und 12 mm Durchmesser quantitativ zu Kohlendioxid oxydiert, das dann an einer erhitzten Ascariteschicht46 spezifisch gebunden wird. Bei Modellversuchen mit 16 verschiedenen organischen Verbindungen wurde festgestellt, daß der Oxydationsgrad unter den angegebenen Bedingungen 0,7–8,7% beträgt. Das entwickelte Verfahren kann somit zur praktisch spezifischen Entfernung von Kohlenoxid aus dem analysierten Luftstrom bei der Bestimmung des TOC-Gehaltes aus flüchtigen, organischen Verunreinigungen nach ihrer Oxydation Anwendung finden.
  相似文献   

17.
Summary A method was developed for the determination of 10 trace elements in ammonium sulphate, or sulphuric acid, respectively. The detection limits for the separate elements vary from 1×10–5 to 5×10–7%. The method includes a new approach for calibration in organic medium, consisting of conversion of the aqueous metal standards into chelate compounds in a homogeneous solution.A three-step optimization scheme for pulse aspiration of organic extracts is proposed which permits to obtain a highly reproducible and accurate signal. The solutions of the organic reagents used are subjected to a purification procedure, which lowers their impurity level for approx. one order of magnitude.
Extraktions-flammenatomabsorptiometrische Bestimmung von Mikrospuren Ag, Bi, Cd, Co, Cu, Fe, Mn, Ni, Pb und Zn in Ammoniumsulfat
Zusammenfassung Ein Verfahren wurde entwickelt zur Bestimmung dieser 10 Elemente in Ammoniumsulfat bzw. Schwefelsäure. Die Nachweisgrenzen der Elemente liegen zwischen 1 · 10–5 und 5 · 10–7%. Das Verfahren beinhaltet auch eine neue Methode zur Eichung in organischem Medium, die auf Umwandlung der wässrigen Metallstandardlösungen in Chelatverbindungen in homogener Lösung beruht. Eine dreistufige Optimierung des pulsierenden Ansaugens der organischen Extrakte wird vorgeschlagen, wodurch genaue und reproduzierbare Signale erhalten werden. Die Lösungen der organischen Reagentien werden einem Reinigungsverfahren unterzogen, das die Konzentration an Verunreinigungen um etwa eine Größenordnung senkt.
  相似文献   

18.
Zusammenfassung Es wird eine Methode für die Probenahme und den Nachweis von geringen Mengen Chlorwasserstoff in Luft vorgestellt. Für die Entwicklung der Probenahmemethode wurden eine Reihe von anorganischen und organischen, in der Gas-Chromatographie üblichen Adsorbentien untersucht, von denen sich Silicagel als am besten geeignet erwies. Bei der Probenahme werden Diffusionsrohre verwendet, um eine Trennung von gasförmigem HCl und Cl in Aerosolen zu ermöglichen. Nach der Adsorption von HCl wird bei 700° C desorbiert und eine Trennung von HCl und Wasser mit einem Perma Pure-Folientrockner durchgeführt. Anschließend wird HCl in einem Teflonrohr kondensiert, mit Cyclohexenoxid zu 2-Chlorcyclohexanol umgesetzt und eine gas-chromatographische Trennung vorgenommen. Der Nachweis erfolgt mit einem elektrolytischen Leitfähigkeitsdetektor nach Hall (HECD). Die minimal nachweisbare Konzentration liegt bei 0,035 ppb HCl.Wir möchten dem Bundesminister für Forschung und Technologie für finanzielle Unterstützung danken.  相似文献   

19.
Summary The simultaneous determination of lead, cadmium and zinc in air particulate matter by anodic stripping voltammetry is described. Optimum conditions for the anodic stripping of lead, cadmium and zinc were determined using ammonium tartrate buffer at pH 4.5. Interferences from other metals were not encountered and the estimations were reproducible within a standard deviation of ±10%. Low blank values and high sensitivity of the method allowed the determinations at sub-ppb levels with an electrolysis time of 3–10 min. The geometric mean concentrations of lead, cadmium and zinc at various locations in Greater Bombay during 1979 are also presented.
Simultanbestimmung von Blei, Cadmium und Zink in Aerosolen durch anodische Stripping-Voltammetrie
Zusammenfassung Die optimalen Bedingungen für die Bestimmung von Pb, Cd und Zn unter Verwendung von Ammoniumtartratpuffer pH 4,5 wurden ausgearbeitet. Störungen durch andere Metalle traten bei den untersuchten Aerosolen nicht auf. Die Standardabweichungen lagen bei ±10%. Infolge niedriger Blindwerte und hoher Empfindlichkeit konnten Bestimmungen im sub-ppb-Bereich mit Elektrolysenzeiten von 3–10 min durchgeführt werden. Ein Überblick über die Konzentration der genannten Metalle in der Luft von Bombay wird gegeben.
  相似文献   

20.
Summary The possibilities of extraction chromatography are investigated for the separation of impurities from high-purity CdTe and ZnSe. The conditions of a quantitative separation of the impurities are determined. As a result of the investigations the techniques are developed for neutron activation analysis of CdTe and spectral analysis of ZnSe, the impurity-detection limits being from 10–5% to 10–7%.
Die Anwendung der Extraktionschromatographie zur Analyse von hochreinem CdTe und ZnSe
Zusammenfassung Die Möglichkeiten der Extraktions-Chromatographie für die Anreicherung von Mikrobeimengungen in hochreinem CdTe und ZnSe wurden untersucht. Dazu wurden die Bedingungen der quantitativen Trennung von Mikrobeimengungen in Cd, Te und Zn ermittelt.Als Ergebnis der Untersuchungen wurden Methoden der Neutronen-Aktivierungsanalyse von ZnSe ausgearbeitet. Bei der Kombination der extraktions-chromatographischen Anreicherung mit diesem Analyseverfahren beträgt die Bestimmungsgrenze für Mikrobeimengungen 10–5–10–7%.


Presented at the 9th International Symposium on Microchemical Techniques, Amsterdam, August 28—September 2, 1983.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号