首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A novel matrix-assisted laser desorption/ionisation quadrupole ion trap time-of-flight (MALDI QIT ToF) mass spectrometer has been used to analyse high mass peptide ions exceeding 2000 Da. Human adrenocorticotropic hormone (fragment 18-39) and oxidised bovine insulin chain B were utilised to evaluate the performance of the instrument both in MS and in MS/MS mode. Its ability to efficiently isolate ions and to fragment them using collisionally activated decomposition (CAD) has been demonstrated using mixtures diluted to the low-femtomole level on target. Additionally, multiple stage mass spectrometry (MS/MS/MS) provides a second-generation product ion spectrum in which new fragment ions are detected and new stretches of amino acids are identified.  相似文献   

2.
Extending the dynamic range of microcapillary liquid chromatography/tandem mass spectrometry (LC/MS/MS) peptide sequencing methods is essential for extracting new discoveries from proteomic studies. The complexity of global protein digests and in vivo processed peptide repertoires (as isolated from immunologically important HLA complexes) have led to the development of novel separation methods to increase the number of peptides identified by a single analysis. Separation of complex mixtures by multidimensional high-performance liquid chromatography (HPLC) decreases the number of isolated peptides contained in each fraction and increases the likelihood of detecting low abundant peptides in a background of dominant signals. In this study, we have evaluated the use of two dimensions of reversed-phase chromatography for resolving and sequencing naturally processed HLA-A2 presented peptide repertoires. The first dimension of separation was reversed-phase chromatography using the strong ion pairing reagent trifluoroacetic acid (TFA) to ensure the highest efficiency of peptide fractionation. The second dimension of reversed-phase chromatography was online with an electrospray ionization (ESI) ion trap mass spectrometer. Mobile phases used for the second dimension of chromatography were modified with volatile reagents including a contemporary acetate-modified acidic solvent, which was compared with mobile phases prepared with ammonium hydroxide at an alkaline pH. As expected, we demonstrate improved separation of the HLA-A2 presented fractions using the alkaline pH conditions. However, less obvious was the improved peptide signal-to-noise detected for peptide signals by positive ion ESI ion trap mass spectrometric detection, which was attributed to a reduced chemical background when using the alkaline pH mobile phases that allowed the ion trap to fill with the peptide ions until the automatic gain control detected a full trap. The term 'wrong-way-round ionization' has been used to describe intense [M+H](+) ions generated during ESI under strongly basic solutions. Ultimately, a larger number of the HLA-A2 peptide repertoire was sequenced by coupling TFA-modified reversed-phase fractionation with alkaline-modified microcapillary LC/MS/MS analysis of each fraction. In the present report, we compare the two second-dimension approaches and demonstrate the quality of data that was acquired using alkaline pH reversed-phase conditions.  相似文献   

3.
A better understanding of the scan-to-scan signal intensity variation can lead to more sophisticated algorithms for database searching and de novo peptide sequencing using single scan mass spectra. In this study, we systematically studied the variation in relative intensity of m/z values in the single scan product ion mass spectra (MS2) derived from five representative precursor ions (MS1) collected using an LTQ linear ion trap under constant flow direct infusion conditions with peptide concentrations held constant. We applied a matching algorithm based on a pair hidden Markov model to align the peaks from each scan belonging to the same m/z value prior to assessing the signal intensity variation. The most significant single contributor to scan-to-scan signal intensity variation for high abundance ions was centroider error. Our study also showed that the variation in signal intensity is higher than what would be expected if the ion statistics derived from the dual geometry electron multiplier detector followed a Poisson distribution.  相似文献   

4.
The importance of imaging mass spectrometry (MS) for visualizing the spatial distribution of molecular species in biological tissues and cells is growing. We have developed a new system for imaging MS using MeV ion beams, termed MeV-secondary ion mass spectrometry (MeV-SIMS) here, and demonstrated more than 1000-fold increase in molecular ion yield from a peptide sample (1154 Da), compared to keV ion irradiation. This significant enhancement of the molecular ion yield is attributed to electronic excitation induced in the near-surface region by the impact of high energy ions. In addition, the secondary ion efficiency for biologically important compounds (>1 kDa) increased to more than 10(10) cm(-2), demonstrating that the current technique could, in principle, achieve micrometer lateral resolution. In addition to MeV-SIMS, peptide compounds were also analyzed with cluster-SIMS and the results indicated that in the former method the molecular ion yields increased substantially compared to the latter. To assess the capability of MeV-SIMS to acquire heavy-ion images, we have prepared a micropatterned peptide surface and successfully obtained mass spectrometric imaging of the deprotonated peptides (m/z 1153) without any matrix enhancement. The results obtained in this study indicate that the MeV-SIMS technique can be a powerful tool for high-resolution imaging in the mass range from 100 to over 1000 Da.  相似文献   

5.
The use of the recently introduced Q-Trap mass spectrometer in the study of protein glycosylation is described. The combined ion trap and triple quadrupole scan functions make it a powerful system in both oligosaccharide and glycopeptide analysis. Several oligosaccharides, both linear and branched, were analyzed to obtain information on sequence, linkage, and branching. Quadrupole like MS/MS spectra with ion trap sensitivity but without the typical ion trap low mass cut-off were obtained. To determine the origin of fragments and to reveal the existence of new ions, the MS(3) capabilities of the system proved to be useful. Glycopeptides were selectively detected in peptide mixtures using the triple quadrupole precursor ion scan function, either in off-line experiments or during LC/MS using information dependent acquisition (IDA).  相似文献   

6.
Atmospheric pressure matrix-assisted laser desorption/ionisation quadrupole ion trap (AP-MALDI/QIT) mass spectrometry has been investigated for the analysis of polyethylene glycol (PEG 1500) and a hyperbranched polymer (polyglycidol) in the presence of alkali-metal salts. Mass spectra of PEG 1500 obtained at atmospheric pressure showed dimetallated matrix/analyte adducts, in addition to the expected alkali-metal/PEG ions, for all matrix/alkali-metal salt combinations. The relative intensities of the desorbed ions were dependent on the matrix, the alkali-metal salt added to aid cationisation and the ion trap interface conditions [capillary temperature, in-source collisionally-induced dissociation (CID)]. These data indicate that the adducts are rapidly stabilised by collisional cooling enabling them to be transferred into the ion trap. Experiments using identical sample preparation conditions were carried out on a vacuum MALDI time-of-flight (ToF) mass spectrometer. In all cases, vacuum MALDI-ToF spectra showed only alkali-metal/PEG ions and no matrix/analyte adducts. The tandem mass spectrometry (MS/MS) capability of the ion trap has been demonstrated for a lithiated polyglycol yielding a rich fragment-ion spectrum. Analysis of the hyperbranched polymer polyglycidol by AP-MALDI/QIT reveals the characteristic ion series for these polymers as also observed under vacuum MALDI-ToF conditions.  相似文献   

7.
Capillary high-performance liquid chromatography has been coupled on-line with an ion trap storage/reflectron time-of-flight mass spectrometer to perform tandem mass spectrometry for tryptic peptides. Selection and fragmentation of the precursor ions were performed in a three-dimensional ion trap, and the resulting fragment ions were pulsed out of the trap into a reflectron time-of-flight mass spectrometer for mass analysis. The stored waveform inverse Fourier transform waveform was applied to perform ion selection and an improved tickle voltage optimization scheme was used to generate collision-induced dissociation. Tandem mass spectra of various doubly charged tryptic peptides were investigated where a conspicuous y ion series over a certain mass range defined a partial amino acid sequence. The partial sequence was used to determine the identity of the peptide or even the protein by database search using the sequence tag approach. Several peptides from tryptic digests of horse heart myoglobin and bovine cytochrome c were selected for tandem mass spectrometry (MS/MS) where it was demonstrated that the proteins could be identified based on sequence tags derived from MS/MS spectra. This approach was also utilized to identify protein spots from a two-dimensional gel separation of a human esophageal adenocarcinoma cell line.  相似文献   

8.
In this study positive ESI tandem mass spectra of the [M + H]+ ions of morphinan alkaloids obtained using an ion trap MS were compared with those from a triple quadrupole MS. This allows to assess the differences of the tandem-in-time versus the tandem-in-space principle, often hampering the development of ESI MS/MS libraries. Fragmentation pathways and possible fragment ion structures were discussed. In order to obtain elemental composition, accurate mass measurements were performed. According to the MS/MS fragmentation pathway, the investigated compounds can be grouped into 4 subsets: (1) morphine and codeine, (2) morphinone, codeinone, and neopinone, (3) thebaine and oripavine, (4) salutaridine and salutaridinol. Salutaridinol-7-O-acetate shows a different fragmentation behavior because of the favored loss of acetic acid. Although most fragment ions occur in both ion trap and triple quad tandem mass spectra, some are exclusively seen in either type. For triple quad, quadrupole time-of-flight and FT-ICR MS/MS, the base peak of morphine results from an ion at m/z 165 that contains neither nitrogen nor oxygen. This ion is not found in ion trap MS/MS, but in subsequential MS3 and MS4.  相似文献   

9.
Various feruloylated arabinose- and galactose-containing mono- and disaccharides with known linkage configurations (2-O-(trans-feruloyl)-L-arabinopyranose, 5-O-(trans-feruloyl)-L-arabinofuranose, O-[2-O-(trans-feruloyl)-alpha-L-arabinofuranosyl]-(1-->5)-L-arabinofuranose, and O-[6-O-(trans-feruloyl)-beta-D-galactopyranosyl]-(1-->4)-D-galactopyranose) were analyzed by electrospray ionization mass spectrometry using an ion trap or a quadrupole time-of-flight (Q-TOF) mass analyzer. Collision-induced dissociation (CID) experiments using the two mass analyzers generated similar tandem mass spectrometric (MS/MS) fragmentation patterns. However, the ester-bond cleavage ions were more abundant using the Q-TOF mass analyzer. Compared with the positive ion mode, the negative ion mode produces simpler and more useful CID product-ion patterns. For arabinose-containing feruloylated compounds, results obtained with both analyzers show that it is possible to assign the location of the feruloyl group to the O-2 or O-5 of arabinosyl residues. In the characterization of the 2-O-feruloyl and 5-O-feruloyl linkages, the relative abundance of the cross-ring fragment ions at m/z 265 (-60 u or -62 u after 18O-labelling) and at m/z 217 (-108 u or -110 u after 18O-labelling) play a relevant role. For galactose-containing feruloylated compounds, losses of 60, 90 and 120 Da observed in MS3 experiment correspond to the production of 0,2A1, 0,3A1 and (0,2A1-60 Da) cross-ring cleavage ions, respectively, fixing the location of feruloyl group at the O-6 of the galactose residue.  相似文献   

10.
The determination of tetra- to octachlorodibenzo-p-dioxins and tetra- to octachlorodibenzofurans (PCCD/Fs) by high-resolution gas chromatography/tandem mass spectrometry (HRGC/MS/MS) and high-resolution gas chromatography/triple mass spectrometry (HRGC/MS(3)) in a quadrupole ion trap, equipped with an external ion source, is presented. MS/MS involves a typical four-step process, namely ionization, parent ion isolation, collision-induced dissociation (CID) and mass analysis of the daughter ions. For the MS(3) experiment, the MS/MS scan function is used with the addition of selected daughter ion isolation, their CID and the mass analysis of second-generation product ions called 'grand-daughter ions.' For both methods, the energies necessary for the CID of the 17 PCDD/Fs were determined and optimized using multiple scan functions with different CID amplitudes. The CID efficiency, defined as the signal ratio of fragment ions detected from the major dissociation channels to molecular ions isolated, was 1.15-2.40 V for parent ion dissociation (MS/MS) and 1.05-1.50 V for daughter ion dissociation (MS(3)) and for all the chloro congeners. The same sensitivity (1 pg microl(-1)) can be reached with both the MS/MS and MS(3) methods and linear responses were obtained between 1 and 100 pg microl(-1) injected.  相似文献   

11.
Analysis of crude methanolic extracts of fresh khat (Catha edulis) by liquid chromatography/mass spectrometry (LC/MS) revealed the presence of 62 cathedulin alkaloids (compared with 15 published structures). Many cathedulins generated doubly protonated molecules following electrospray ionisation and the ratio of doubly to singly protonated species could be manipulated by adjusting the electrospray capillary position and source conditions. By selecting the doubly protonated species for serial mass spectrometric analysis (MS/MS), it was possible to use an ion trap mass spectrometer to observe singly charged product ions at lower m/z values than ion trap MS/MS analysis of [M+H](+) would have allowed. These spectra were particularly valuable in elucidating the acylation patterns of cathedulins where MS/MS analysis of [M+H](+) resulted in loss of a large neutral species to yield a small singly charged fragment below the lower limit for ion trapping. Acylation patterns for most of the 62 cathedulins are proposed from mass spectrometric analysis, and the data obtained for a major unreported cathedulin of mass 1001 Da suggest that it belongs to a new group of cathedulins having a cathate dilactone bridge but not an evoninate bridge.  相似文献   

12.
Electrospray ionization (ESI) mass spectrometry was applied to the structural analysis of 23 2,6-[bis(alkyloxy)methyl]phenyltin(IV) derivatives. The mass spectra were measured in both polarity modes and multistage tandem mass spectrometric (MS(n)) measurements were performed on the ion trap analyser for positively charged tin-containing ions. The sum of complementary ions observed in the positive-ion mode (i.e. [M-R(3)](+) ion) and in the negative-ion mode (i.e. [R(3)](-) ion) permits molecular mass determination in spite of the fact that the molecular adducts were often missing even in the first-order mass spectra. The subsequent fragmentation of [M-R(3)](+) ions studied by MS(n) and the correlation of observed fragment ions with the expected structures of synthesized organotin(IV) compounds allowed us to understand the fragmentation behaviour and the mechanism of the ion formation for studied compounds. The typical neutral losses are alkenes, alcohols and aldehydes. The fragmentation pattern of one selected compound was supported by MS(n) measurements of an isotopically labelled analogue to confirm unusual ion-molecule reactions of some fragment ions with water in the ion trap.  相似文献   

13.
Product ions obtained by tandem mass spectrometry (MS/MS) are quite effective for the amino acid sequencing of linear peptides. However, in the case of cyclic peptides, the fragmentation pattern is complicated because the cleavages occur randomly and product ions are generated as a(n), b(n), c(n), x(n), y(n) and z(n) series ions; therefore, the authors have never obtained sufficient sequence information. In order to overcome this problem, we applied ion trap liquid chromatography/multi-stage mass spectrometry (LC/MS(n)) and characterized the product ions obtained from anabaenopeptins and aeruginopeptins as the cyclic peptides. For the anabaenopeptins, MS(2) analysis did not provide sufficient sequence information on the cyclic structure, and MS(3) analysis was applied to sequence the constituent amino acids. Diagnostic product ions were obtained by the MS(3) analysis and were quite effective for obtaining the sequence information of the constituent amino acids. MS(2) analysis was, however, sufficient to obtain the sequence information of the aeruginopeptins. In both cases, the resulting product ions obtained from the cyclic structures were formed by the two-bond fission mechanism of the precursor ion, in which an initial fission of the cyclic structure to a linear one and subsequent fission(s) at the peptide bonds are included. The fragmentations were similar for the structurally related compounds, indicating that the cleavages occurred at definite peptide bonds. In addition, the resulting product ions are generated as b(n) series ions and the mass difference facilitates the amino acid sequencing. Thus, ion trap LC/MS(n) provides sequence information, and the resulting product ions are reproducible among the structurally related compounds and reliable for the sequencing of the constituent amino acids of the cyclic structure.  相似文献   

14.
A mass spectrometric (MS) comparative study of dextran samples using two different ionization techniques (matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI)) in both positive- and negative-ion modes is reported. The experiments were carried out with two polydisperse dextrans (1000 and 8800 Da) and isomaltotriose. In the positive-ion mode, the expected alkali metal ion adducts of dextrans were observed in both techniques. In contrast, the expected preferential formation of deprotonated molecules [M - H](-) was not confirmed in negative mode MALDI time-of-flight (TOF) MS, where the series of ions [M(x)- H +42](-) or [M(x+1)- H - 120](-), coming either from some addition or fragmentation, were observed. In both ionization techniques, these ions formed the main distributions of dextrans in the negative-ion mode. It seems that the negative molecular ions formed from the alpha1 --> 6 linkage of polyglucose oligomers easily decompose, and the product ions [M - H - 120](-) markedly dominate. The fragmentation experiments and especially the investigation of the fundamental role of the nozzle-skimmer potential in ESI-MS supported our explanation of the observed behavior because its higher values caused higher fragmentation. The experiments with isomaltotriose excluded any addition of 42 Da during the MS procedures, which is not distinguishable from the loss of 120 Da in the case of polydisperse dextrans. MALDI-TOFMS was found to be more sensitive for the detection of higher oligosaccharides and ESI-MS more useful for structural studies.  相似文献   

15.
An API 3000 triple-quadrupole instrument and a QSTAR Pulsar quadrupole time-of-flight (TOF) mass spectrometer were compared for the determination of phosphopeptides by precursor ion scanning in both the positive and negative nanoelectrospray ionization modes. The limits of detection for synthetic phosphopeptides were similar (500 amol microl(-1)) for both types of instruments when monitoring precursors of -79 Da (PO(3)(-)). However, the quadrupole TOF system was approximately fivefold more sensitive (1 fmol microl(-1)) than the triple-quadrupole instrument (5 fmol microl(-1)) when monitoring precursors of 216 Da (immonium ion of phosphotyrosine). The recently introduced Q(2)-pulsing function, which enhances the transmission of fragment ions of a selected m/z window from the collision cell into the TOF part, improved the sensitivity of precursor ion scans on a quadrupole TOF instrument. The selectivity of precursor ion scans is much better on quadrupole TOF systems than on triple quadrupoles because the high resolving power of the reflectron-TOF mass analyzer permits high-accuracy fragment ion selection at no expense of sensitivity. This minimizes interferences from other peptide fragment ions (a-, b-, and y- type) of the same nominal mass but with sufficient differences in their exact masses. As a result, the characteristic immonium ion of phosphotyrosine at m/z 216.043 can be utilized for the selective detection of tyrosine phosphorylated peptides. Our data suggest that, in addition to their superior performance for peptide sequencing, quadrupole TOF instruments also offer a very viable alternative to triple quadrupoles for precursor ion scanning, thus combining high sensitivity and selectivity for both MS and MS/MS experiments in one instrument.  相似文献   

16.
Isobaric product ions cannot be differentiated by exact mass determinations, although in some cases deuterium labeling can provide useful structural information for identifying isobaric ions. Proposed fragmentation pathways of fentanyl were investigated by electrospray ionization ion trap mass spectrometry coupled with deuterium labeling experiments and spectra of regiospecific deuterium labeled analogs. The major product ion of fentanyl under tandem mass spectrometry (MS/MS) conditions (m/z 188) was accounted for by a neutral loss of N‐phenylpropanamide. 1‐(2‐Phenylethyl)‐1,2,3,6‐tetrahydropyridine (1) was proposed as the structure of the product ion. However, further fragmentation (MS3) of the fentanyl m/z 188 ion gave product ions that were different from the product ion in the MS/MS fragmentation of synthesized 1, suggesting that the m/z 188 product ion from fentanyl includes an isobaric structure different from the structure of 1. MS/MS fragmentation of fentanyl in deuterium oxide moved one of the isobars to 1 Da higher mass, and left the other isobar unchanged in mass. Multistage mass spectral data from deuterium‐labeled proposed isobaric structures provided support for two fragmentation pathways. The results illustrate the utility of multistage mass spectrometry and deuterium labeling in structural assignment of isobaric product ions. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
This study has elucidated the fragmentation pathway for deprotonated isoflavones in electrospray ionization using MS(n) ion trap mass spectrometry and triple quadrupole mass spectrometry. Genistein-d(4) and daidzein-d(3) were used as references for the clarification of fragment structures. To confirm the relationship between precursor and product ions, some fragments were traced from MS(2) to MS(5). The previous literature for the structurally related flavones and flavanones located the loss of ketene (C(2)H(2)O) to ring C, whereas the present fragmentation study for isoflavones has shown that the loss of ketene occurs at ring A. In the further fragmentation of the [M-H-CH(3)](-*) radical anion of methoxylated isoflavones, loss of a hydrogen atom was commonly found. [M-H-CH(3)-CO-B-ring](-) is a characteristic fragment ion of glycitein and can be used to differentiate glycitein from its isomers. Neutral losses of CO and CO(2) were prominent in the fragmentation of deprotonated anions in ion trap mass spectrometry, whereas recyclization cleavage accounted for a very small proportion. In comparison with triple quadrupole mass spectrometry, ion trap MS(n) mass spectrometry has the advantage of better elucidation of the relationship between precursor and product ions.  相似文献   

18.
To enable the development of a tandem mass spectrometry (MS/MS) based methodology for selective protein identification and differential quantitative analysis, a novel derivatization strategy is proposed, based on the formation of a "fixed-charge" sulfonium ion on the side-chain of a methionine amino acid residue contained within a protein or peptide of interest. The gas-phase fragmentation behavior of these side chain fixed charge sulfonium ion containing peptides is observed to result in exclusive loss of the derivatized side chain and the formation of a single characteristic product ion, independently of charge state or amino acid composition. Thus, fixed charge containing peptide ions may be selectively identified from complex mixtures, for example, by selective neutral loss scan mode MS/MS methods. Further structural interrogation of identified peptide ions may be achieved by subjecting the characteristic MS/MS product ion to multistage MS/MS (MS3) in a quadrupole ion trap mass spectrometer, or by energy resolved "pseudo" MS3 in a triple quadrupole mass spectrometer. The general principles underlying this fixed charge derivatization approach are demonstrated here by MS/MS, MS3 and "pseudo" MS3 analysis of side chain fixed-charge sulfonium ion derivatives of peptides containing methionine formed by reaction with phenacylbromide. Incorporation of "light" and "heavy" isotopically encoded labels into the fixed-charge derivatives facilitates the application of this method to the quantitative analysis of differential protein expression, via measurement of the relative abundances of the neutral loss product ions generated by dissociation of the light and heavy labeled peptide ions. This approach, termed "selective extraction of labeled entities by charge derivatization and tandem mass spectrometry" (SELECT), thereby offers the potential for significantly improved sensitivity and selectivity for the identification and quantitative analysis of peptides or proteins containing selected structural features, without requirement for extensive fractionation or otherwise enrichment from a complex mixture prior to analysis.  相似文献   

19.
Three samples of albumin derived from human plasma (pharmaceutical grade, HSA) obtained from different commercial sources were investigated for their micro-heterogeneities by means of electrospray ionization (ESI) ion trap mass spectrometry (ITMS). The study covered MS analyses of the intact proteins as well as on the tryptic peptide level. The intact protein samples were analyzed without any separation step except for simple desalting. With these samples we observed in the positive ion ESI mass spectra that the multiply charged ion signals of HSA consisted of a number of fully or partly resolved peaks with relative intensities depending on the analyzed sample. The non-modified form of HSA was detected in the three HSA preparations at m/z values of 66448 +/- 3.6, 66450 +/- 0.6 and 66451 +/- 3.2 ([MH]+), respectively. The value calculated from the amino acid sequence was 66439. The second compound present with high intensity (in two cases the base peak in the deconvoluted mass spectrum) is interpreted as a modified HSA, and the molecular mass increase in relation to the unmodified HAS was between 116 and 118 Da (m/z of 66 564, 66 567 and 66 569), suggesting the presence of a covalently bound cysteine residue. A further peak in the deconvoluted ESI spectra was found in all three samples with rather low signal/noise ratio at m/z 66 619, 66 621 and 66 613, respectively, which may correspond to a non-enzymatic glycation described in the literature. The verification of the proposed covalent HSA modifications was subsequently done on the peptide level using high-performance liquid chromatography (HPLC)/ESI-MS and HPLC/ESI-MS/MS including low-energy collision-induced dissociation (CID). Prior to the tryptic digestion, the HSA samples were alkylated without a prior reduction step. Following this procedure we detected peptides of the sequence T21-41 that included the Cys-34 residue in both forms: cysteinylated (m/z 639.15 [M+4H]4+) as well as vinylpyridine-alkylated (m/z 635.69 [M+4H]4+, which means in its previously native free SH form). In the next step on-line LC/ESI low-energy CID MS/MS experiments were performed to verify these two proposed structures. By means of MS/MS analysis of the mentioned ions the described modification (cysteinylation) at the Cys-34 residue could be proven. This abundant modification of HSA in pharmaceutical-grade preparations could be unambiguously identified as cysteinylation at the Cys-34 residue. On the other hand, the proposed non-enzymatic glycation was not detectable on the peptide level in the on-line HPLC/ESI-MS mode, maybe due to the low concentration in the three samples under investigation.  相似文献   

20.
Fragmentation of polyethers, such as poly(ethylene glycol) (PEG), poly(propylene glycol) and poly(tetramethylene glycol) was analyzed by matrix-assisted laser desorption/ionization tandem mass spectrometry (MALDI-MS/MS) using a quadrupole ion trap time-of-flight mass spectrometer (QIT-ToF). The Li adduct ion provided more abundant fragments than the Na and K adduct ions in the MS/MS spectra. A previous study had demonstrated four series fragments of hydroxyl-, vinyl- and formyl-terminated ions, as well as distonic cations, in high-energy fast atom bombardment MS/MS and MALDI collision-induced dissociation measurements of poly(ethylene glycol). In the present study, the low-energy MS/MS measurements using MALDI-QIT-ToF, showed hydroxyl-, vinyl- and formyl- terminated fragments with or without other fragment groups, but not distonic cations. The fragmentation depended on the types of polyethers examined. MS/MS measurements using MALDI-QIT-ToF are expected to allow structural characterization of unknown components of polyethers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号