首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
A precise, accurate, and sensitive UV spectrophotometric method was developed and validated for routine quantification of total bioflavonoids, expressed as rutin, from a topical oil-in-water pharmaceutical emulsion containing the extract of Trichilia catigua Adr. Juss and Ptychopetalum olacoides Bentham. The method was validated experimentally, and the data were treated rigorously by statistical analysis. The following analytical parameters were assessed: linearity, specificity, intra- and interrun precision measured as relative standard deviation (RSD, %), intra- and interrun accuracy (E, %), recovery (Rec., %), limit of detection (LOD, microg/mL), and limit of quantification (LOQ, microg/mL). The UV spectrophotometric method was linear (r = 0.9995) for standard rutin over the concentration range of 5.0-15.0 microg/mL with specificity for total bioflavonoids (expressed as rutin) at 361.0 nm with an absence of interferents from the complex matrix; RSD of < or = 1.79%, intrarun (E = 97.88 +/- 1.75 to 99.0 +/- 0.33%) and interrun (E = 98.38 +/- 1.12 to 100.79 +/- 1.30%) accuracy; Rec. = 98.64 +/- 0.42 to 100.74 +/- 0.41%; LOD = 0.20 microg/mL; and LOQ = 0.30 microg/mL.  相似文献   

2.
Two sensitive and selective methods were developed for the determination of some oxicams, namely, lornoxicam (LOX), tenoxicam (TEX), and meloxicam (MEX), in the presence of their alkaline degradation products. The first method is based on the thin-layer chromatographic separation of the 3 drugs from their alkaline degradation products, followed by densitometric measurement of the intact drug spots for LOX, TEX, and MEX at 380, 370, and 364 nm, respectively. The developing systems used for separation are ethyl acetate-methanol-26% ammonia (17 + 3 + 0.35, v/v/v) for LOX and TEX and chloroform-n-hexane-96.0% acetic acid (18 + 1 + 1, v/v/v) for MEX. The linear ranges were 0.25-6.0 microg/spot for LOX and TEX and 0.5-10 microg/spot for MEX, with mean recoveries of 99.80 +/- 1.32, 100.57 +/- 1.34, and 100.71 +/- 1.57%, respectively. The second method is based on the liquid chromatographic separation of the 3 drugs from their alkaline degradation products on a reversed-phase C18 column, using mobile phases of methanol-acetonitrile-acetate buffer, pH 4.6 (4.5 + 0.5 + 5.0, v/v/v) for LOX and MEX and methanol-acetonitrile-acetate buffer, pH 4.6 (1.9 + 0.1 + 3.0, v/v/v) for TEX at ambient temperature. Quantification is achieved by UV detection at 280 nm, based on peak area. The linear ranges were 0.5-20 microg/mL for LOX and TEX and 1.25-50 microg/mL for MEX, with mean recoveries of 99.81 +/- 1.01, 98.90 +/- 1.61, and 100.86 +/- 1.55%, respectively. The methods were validated according to guidelines of the International Conference on Harmonization. The developed methods were successfully applied to the determination of LOX, TEX, and MEX in bulk powder, laboratory-prepared mixtures containing different percentages of degradation products, and pharmaceutical dosage forms.  相似文献   

3.
A selective, precise, and accurate method was developed for the determination of cimetidine (C), famotidine (F), and ranitidine hydrochloride (R x HCl) in the presence of their sulfoxide derivatives. The method involves quantitative densitometric evaluation of mixtures of the drugs and their derivatives after separation by high-performance thin-layer chromatography on silica gel plates (10 x 20 cm) with ethyl acetate-isopropanol-20% ammonia (9 + 5 + 4, v/v) as the mobile phase for both C and F and ethyl acetate-methanol-20% ammonia (10 + 2 + 2, v/v) as the mobile phase for R x HCl; Rf values for C, F, and R x HCl and their corresponding derivatives were 0.85 and 0.59, 0.73 and 0.41, and 0.56 and 0.33, respectively. Developing time was approximately 20 min. For densitometric evaluation, peak areas were recorded at 218, 265, and 313 nm for C, F, and R x HCl, respectively. The relationship between concentration and the corresponding peak area was plotted for the ranges of 5-50 microg/spot for C and 2-20 microg/spot for F and R x HCl. Mean recoveries were 100.39 +/- 1.33, 99.77 +/- 1.30, and 100.09 +/- 0.69% for C, F, and R x HCl, respectively. The proposed method was used successfully for stability testing of the pure drugs in the presence of up to 90% of their degradates, in bulk powder and dosage forms. The results obtained were analyzed statistically and compared with those obtained by the official methods.  相似文献   

4.
A simple, sensitive and selective RP-HPLC method has been developed for quantification of nodakenin in rat plasma. Nodakenin in rat plasma was extracted with acetonitrile, which also acted as a deproteinization agent. Chromatographic separation of nodakenin was performed on an analytical Diamonsil ODS C18 column, with a mobile phase of MeOH-H2O (1:1, v/v) at a flow-rate of 1.0 mL/min, and UV detection was set at 330 nm. The calibration curve was linear over the range 0.2-12.0 microg/mL (R2 = 0.9995) in rat plasma. The lower limit of detection and quantification were 0.01 and 0.1 microg/mL, respectively, using the rat plasma sample. The extraction recoveries were 77.36 +/- 4.56, 82.89 +/- 1.84 and 81.66 +/- 2.49% at concentrations of 1.0, 5.0 and 10.0 microg/mL, respectively. The intra- and inter-day precision and accuracy were validated by relative standard deviation and relative error, which were in the ranges 5.07-5.83 and 3.95-6.29%, respectively. After i.v. administration to rats at a single dose of 40 mg/kg, the plasma concentration-time curve of nodakenin was best conformed to a two-compartment open model. This assay method has been successfully applied to the study of the pharmacokinetics of nodakenin in rats.  相似文献   

5.
A simple, sensitive and precise high-performance thin-layer chromatographic (HPTLC) method of analysis of trans-resveratrol in Polygonum cuspidatum root extracts and in dosage forms was developed and validated. The separation was carried out on a TLC aluminium plates precoated with silica gel 60F-254 as the stationary phase, eluted with chloroform-ethylacetate-formic acid (2.5 : 1 : 0.1) as mobile phase. Densitometric analysis of trans-resveratrol was carried out in the absorbance mode at 313 nm. This system was found to give compact spot for trans-resveratrol (Rf value of 0.40+/-0.03). A good linear regression relationship between peak areas and the concentrations was obtained over the range of 0.5-3.0 microg/spot with correlation coefficient 0.9989. The limit of detection and quantification was found to be 9 and 27 ng/spot. The method was validated for precision and recovery. The spike recoveries were within 99.85 to 100.70%. The RSD values of the precision in the range 0.37-1.84%. The proposed developed HPTLC method can be applied for identification and quantitative determination of trans-resveratrol in herbal extracts and dosage forms.  相似文献   

6.
A simple and reproducible HPLC method for quantification of hydroxysafflor yellow A (HSYA) in rat plasma and tissues after oral administration of safflower extract or safflor yellow (SY) was developed. Sample preparation was achieved by protein precipitation of plasma and tissue homogenates with three volumes of methanol. p-Hydroxybenzaldehyde was used as the internal standard (IS). HSYA and IS were separated on a Hypersil BDS-C(18) column with a gradient elution system composed of acetonitrile and aqueous acetic acid. UV detection was used at 320 nm. The calibration curves were linear in all matrices (r(2) > 0.999) in the concentration ranges 0.51-101.36 microg/mL for plasma, 12.27-2454.46 microg/g for intestines and 0.96-192.20 microg/g for lung. The intra-day and inter-day precision were all less than 12.5%, and the extract recovery was in the range 64.1-103.7% with RSD less than 15.6% for HSYA in all matrices. The method was used successfully to quantify HSYA in rat plasma and tissue samples to support a pharmacokinectic study.  相似文献   

7.
An ion chromatographic (IC) method with suppressed conductivity detection (CD) was developed and validated for the quantitative determination of several low-molecular-mass aliphatic mono- and dicarboxylic acids as their carboxylate anions together with some inorganic anions (chloride, sulfate, and thiosulfate) from kraft black liquors. To confirm the identification of some carboxylate anions which lack commercial model substances, a qualitative IC method with suppressed electrospray ionization mass spectrometry (ESI-MS) was also developed. The separations were performed on an IonPac AS 11-HC anion-exchange column operated at 25 degrees C within 25 min by a gradient elution with aqueous potassium hydroxide (suppressed CD in the AutoRegen mode) or sodium hydroxide (suppressed ESI-MS in the pressurized bottle mode). In the validation process a mixture of carboxylic acids and inorganic anions in aqueous media and in seven different types of wood and non-wood black liquor samples were quantitatively analyzed by IC-CD. As a result, calibration lines with correlation coefficients of 1.00 for all analytes were achieved at a concentration range from 0.05 to 105 mg L(-1). In black liquor samples intra-day (n=6) precision values ranged from 0.9 to 5%. Day-to-day (n1=3) and intermediate precision values were less than 5% for all other compounds except sulfate and thiosulfate. The variability in the thiosulfate and sulfate results is due in large part to the oxidation of sulfide and thiosulfate, respectively. Recoveries were close to 100% with standard deviations less than 8%. Depending of the analyte, the limits of detection and quantification were, respectively, between 1 and 8 microg L(-1) and between 3 and 27 microg L(-1) for standard compounds in aqueous media and between 6 and 106 microg L(-1) and between 14 and 148 microg L(-1) for black liquor samples. These validation results clearly indicated that with respect to selectivity, linearity, limits of detection and quantification, precision, and accuracy, the IC-CD method showed good applicability in the determinations described above.  相似文献   

8.
An inexpensive, rapid and reproducible capillary electrophoretic method has been developed and validated for the determination of metformin in pharmaceutical preparations. The method was developed utilizing a fused silica capillary (60 cm x 50 microm I.D.), phosphate buffer (50 mM, 3.0 pH)-acetonitrile (95:5, v/v) as background electrolyte (BGE), 20 kV applied voltage with UV detection at 254 nm and at a working temperature of 23 +/- 1 degrees C. Linearity was observed in the concentration range from 100 ng/L to 5 microg/L, with a correlation coefficient (R2) of 0.9998. The limits of detection and quantification achieved were 60 and 100 ng/mL, respectively. The recovery of metformin from pharmaceutical preparations was 99.1%. These validation parameters demonstrate the precision of the method and its suitability for the determination of metformin in pharmaceutical tablet formulations.  相似文献   

9.
A simple high-performance liquid chromatographic (HPLC) method was developed and validated for the quantification of mizoribine in human serum. After the addition of 70% perchloric acid and 3-methylxanthine (50 microg/mL, internal standard) to human serum, the samples were mixed and centrifuged at 12,000 rpm (1432 g) for 10 min. The supernatant was injected onto a C(18) column eluted with a mobile phase of 20 mm Na2HPO4 and methanol (93:7, v/v, pH 3) containing 0.04% octanesulfonic acid and detected utilizing an ultraviolet detector at 275 nm. The linear calibration curve was obtained in the concentration range of 0.1-4.0 microg/mL and the lower limit of quantification was 0.1 microg/mL. This method was validated with selectivity, linearity, precision and accuracy. In addition, the method was successfully applied to estimate the pharmacokinetic parameters of mizoribine in Korean subjects following an oral administration of 100 mg mizoribine (two Bredinine 50 mg tablets). The maximum serum concentration (C(max)) of 2.30 +/- 0.83 microg/mL was reached 2.27 +/- 0.66 h after an oral dose. The mean AUC(0-12 h) and the elimination half-life (t(1/2)) were 13.2 +/- 4.79 microg h/mL and 3.10 +/- 0.74 h, respectively.  相似文献   

10.
A rapid, simple, and highly sensitive second derivative synchronous fluorometric method has been developed for the simultaneous determination of metoclopramide (MT) and pyridoxine (PY) in a binary mixture. The method is based on measurement of the native fluorescence of these drugs at delta lambda = 80 nm in methanol. The different experimental parameters affecting the native fluorescence of the drugs were carefully studied and optimized. The fluorescence-concentration plots were rectilinear over the ranges of 0.02-0.4 and 0.1-2 microg/mL for MT and PY, respectively. The limits of detection were 0.003 and 0.007 microg/mL and the limits of quantification were 0.008 and 0.02 microg/mL for MT and PY, respectively. The proposed method was successfully applied to the determination of MT and PY in synthetic mixtures and in commercial syrup. The results were in good agreement with those obtained with a reported method. The high sensitivity attained by the proposed method allowed the determination of MT in spiked and real human plasma samples. The mean percent recoveries of MT from spiked and real human plasma (n = 3) were 93.72 +/- 3.15 and 89.72 +/- 2.19 respectively.  相似文献   

11.
A liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the determination of residues of the anaesthetic tricaine mesilate (MS222) in fish tissues is described. Residues were extracted from homogenized tissues with McIllvaine buffer/methanol and purified over a C18 solid-phase extraction column followed by LC-MS/MS analysis. In the multiple-reaction monitoring mode of the mass spectrometer, chromatograms were recorded by monitoring the m/z 166-->m/z 138 and m/z 166-->m/z 94 transitions for quantification and confirmation of the residues in the finfish matrix, respectively. Recoveries were in the range of 67%+/-10% (n=6) for tilapia at 2 microg kg(-1), 95%+/-7% (n=6) at 2 microg kg(-1) in salmon and 92%+/-3% (n=5) for trout at 2.5 microg kg(-1). The limits of detection were 0.5, 0.6 and 0.6 microg kg(-1) in trout, salmon and tilapia, respectively. No residues of tricaine were found in eight sampled aquacultured fish (salmon and trout) bought from the local market.  相似文献   

12.
手性衍生-高效液相色谱法拆分和定量测定茶氨酸对映体   总被引:1,自引:0,他引:1  
李银花  刘仲华  黄建安 《色谱》2007,25(5):719-722
建立了以1-氟-2,4-二硝基苯基-5-L-丙氨酰胺(FDAA)为手性衍生试剂、高效液相色谱拆分茶氨酸对映体的方法。采用的色谱条件为:Kromasil C18色谱柱;三乙胺-磷酸缓冲液和乙腈为流动相,梯度洗脱,流速1.0 mL/min;检测波长为340 nm;柱温为35 ℃。L-茶氨酸的进样量在1.732×10-3~2.077 μg范围内峰面积与进样量之间的线性关系良好,加标回收率为97.3%~102.0%,检测限为4.973×10-4 μg,定量限为1.223×10-3 μg。D-茶氨酸的进样量在1.696×10-3~2.044 μg范围内峰面积与进样量之间的线性关系良好,加标回收率为97.2%~103.2%,检测限为5.871×10-4 μg,定量限为1.236×10-3 μg。该方法灵敏度高,分析过程中不发生消旋化。  相似文献   

13.
A packaging contaminant: isopropylthioxanthone (ITX) in dairy products   总被引:2,自引:0,他引:2  
A fast, simple and very selective liquid chromatography-mass spectrometry (LC-MS) method for the detection of isopropylthioxanthone (ITX) in dairy products has been developed and validated. After addition of an ITX-d(3) as internal standard and a simple extraction from the sample with acetonitrile, the extract was centrifuged and directly injected into the LC-MS system. Chromatographic separation was achieved by means of a Gemini C18 column (100 mm x 2.0 mm i.d. 5 microm) using a gradient of aqueous 20 mM ammonium formiate at pH 4.5 and methanol as the mobile phase, at a flow rate of 0.25 mL min(-1). The method was validated according to the guidelines laid down by the Commission Decision 2002/657/EC using the parent ion [M+H](+) (m/z 255) as quantification ion, and the fragment ion (m/z 213) obtained by in-source collision-induced dissociation (IS-CID) as confirmation ion. Absolute and relative recoveries rates were verified at 5, 10, 15 microg kg(-1) in yoghurt samples and at 5 microg kg(-1) in milk and pudding: mean absolute recoveries were 77% in yoghurt, 50% in pudding and 67% in milk; relative recoveries (after internal standard correction) were always >97% in each matrix. The detection limit (CCalpha) and the detection capability (CCbeta) of method were 6.2 and 7.2 microg kg(-1), respectively.  相似文献   

14.
Four new methods were developed and validated for the determination of cinnarizine HCl in its binary mixture with piracetam in pure and pharmaceutical preparations. The first one was a densitometric analysis that provides a simple and rapid method for the separation and quantification of cinnarizine HCI. The method depends on the quantitative densitometric evaluation of thin-layer chromatograms of cinnarizine HCI at 252 nm over concentration range of 1-6 microg/spot, with a mean accuracy of 100.05 +/- 0.91%. The second method was determination of the drug using a colorimetric method that utilizes the reaction of 3-methyl-benzothiazolin-2-one in the presence of FeCl3 as an oxidant. The green color of the resulting product was measured at 630 nm over concentration range 10-40 microg/mL, with a mean accuracy of 100.10 +/- 1.13%. The third method was a direct spectrophotometric determination of cinnarizine HCI at 252 nm over the concentration range 7-20 microg/mL, while piracetam was determined by derivative ratio spectrophotometry at 221.6 nm over concentration range 5-30 microg/mL, with a mean accuracy of 100.14 +/- 0.79 and 100.26 +/- 1.24% for cinnarizine HCI and piracetam, respectively. The last method was a liquid chromatography analysis of both cinnarizine HCI and piracetam, depending on quantitative evaluation of chromatograms of cinnarizine HCI and piracetam at 252 and 212 nm, respectively, over the concentration range 10-200 microg/mL for cinnarizine HCI and 20-500 microg/mL for piracetam, with a mean accuracy of 100.03 +/- 0.89 and 100.40 +/- 0.94% for cinnarizine HCI and piracetam, respectively. The proposed procedures were checked using laboratory-prepared mixtures and successfully applied for the analysis of their pharmaceutical preparations. The validity of the proposed procedures was further assessed by applying the standard addition technique. Recoveries were quantitative, and the results obtained agreed with those obtained by other reported methods.  相似文献   

15.
A liquid chromatography method was developed for the determination of antifungal/antimicrobial proteins Rs-AFP1 and Dm-AMP1 in sandy loam soils. The extraction of these highly basic proteins was achieved by mechanical shaking with aqueous Tris buffer pH 9 containing guanidinium thiocyanate salt (4.1 M), EDTA and nonionic polyoxyethylene 20 cetyl ether, Brij-58 detergent. The extracts were cleaned up on Oasis HLB polymer solid-phase extraction cartridges and quantified by liquid chromatography fluorescence detection based on the fluorescence properties of the tryptophan content of these proteins. The detector response was linear for 0.3-10 microg mL(-1). Procedural recoveries were tested in the range 10-100 mg kg(-1). The limit of quantification was 10 mg kg(-1 )protein in the soil sample representing the lowest validated fortification level. The antifungal proteins were found to be stable in soil extract tested up to 9 days when stored at 4 degrees C.  相似文献   

16.
A method was developed for the generation of a "cold vapor" of cadmium by means of flow injection-chemical vapor generation from aqueous samples, the determination being conducted with an atomic absorption spectrometer (Pyrex glass T-cell). Several gas-liquid separator designs, atomizer designs, and the effect of several reagents previously reported as sensitivity enhancers (including cobalt, nickel, thiourea and didodecyl-dimethylammonium bromide) were investigated. The limit of detection, calculated as the concentration giving a signal equal to three times the standard deviation of the blank, was 16 ng L(-1), and the relative standard deviation was 1.4% for a concentration of 2 microg L(-1) and 3.8% for 0.1 microg L(-1). The addition of nickel and thiourea to the samples provided improved tolerance to the interference of coexisting ions. Two NIST certified reference materials, Montana Soil and Apple Leaves (respectively containing 41.7+/-0.25 mg kg(-1) Cd and 0.013+/-0.002 mg kg(-1) Cd) were accurately analyzed. The interference of lead was overcome by coprecipitation with barium sulfate, and the experimental values obtained were 41+/-1 mg kg(-1) Cd and 0.013+/-0.002 mg kg(-1) Cd, respectively.  相似文献   

17.
An improved method has been developed for the determination of acrylamide in infant powdered milk and baby foods in jars, a particular class of foodstuffs which represent an important source of nutrition for young infants and babies. This method uses isotope dilution liquid chromatography coupled to a tandem mass spectrometer with electrospray ionization and is significantly more sensitive than previous published methods with a limit of quantification estimated at 1 microg kg(-1). The new method offers effective sample preparation procedures including defatting with petroleum ether, extraction with aqueous solution of sodium chloride, further liquid-liquid extraction with ethyl acetate and clean-up by solid-phase extraction (SPE) with HLB 200 mg cartridges. The analytical method was well validated and good results were obtained with respect to repeatability (RSD < 5%) and recovery (86-97%) which fulfilled the requirements defined by European Union (EU) legislation. The acrylamide level in infant powdered milk and baby foods in jars were 3.01-9.06 microg kg(-1) and 6.80-124.93 microg kg(-1), respectively. Especially, this new method is successfully applied to the trace quantification of acrylamide in infant/baby foods, the content of which is less than 10 microg kg(-1).  相似文献   

18.
The present study developed an improved analytical method for the simultaneous quantification of 17 kinds of Aspergillus, Fusarium and Penicillium mycotoxin contaminants in foods and feeds by ultra-performance liquid chromatography combined with electrospray ionization triple quadrupole tandem mass spectrometry (UPLC-MS/MS) under the multiple reaction monitoring (MRM) mode, and especially focused on the optimization of extraction, clean-up, UPLC separation and MS/MS parameters of analytes. Homogenized samples were sequentially extracted by 84% (v/v) of acetonitrile aqueous solution with the selected internal standard (zearalanone) spiking, SPE clean-up with Mycosep 226 Aflazon+ Multifunctional cartridges, filtration, concentration and secondary filtration. Using double sample injection method, the analytes were separated by UPLC BEH C18 column (100 mm x 2.1 mm I.D., 1.7 microm), and eluted with ammonium acetate/methanol and aqueous ammonia/methanol for the ESI+ and ESI- analysis, respectively. The 10 positive ions and 7 negative ions of mycotoxins were separated by gradient elution with the retention time of 6.5 and 4 min, respectively. The LOQ of selected analytes ranged from 0.01 to 0.70 microg kg(-1), which was lower than the criteria of EU, USA and other countries on the determination of the minimum limiting level of various mycotoxins in foods including baby foods and feed stuffs. Meanwhile, high correlation coefficients (r2>0.99) of 17 mycotoxins were obtained within their respective linear ranges (0.05-20 microg kg(-1) for 10 positive ions and 0.5-50 microg kg(-1) for 7 negative ions) and reasonable recoveries (70.6-119.0%) of them were also demonstrated in different spiked levels. This quantitative method has many advantages including simple pretreatment, rapid determination and high sensitivity, which could be applied to the determination and quantification of multi-component mycotoxin contaminants in complex matrixes. Meanwhile, the method successfully fulfilled the minimum limiting level requests from various countries.  相似文献   

19.
Potato glycoalkaloids are produced in high amounts in potato fields during the growth season and losses to soil potentially impact shallow groundwater and via tiles to fresh water ecosystems. A quantitative liquid chromatography-electrospray ionization time-of-flight mass spectrometry (LC-ESI-TOF-MS) method for determination and quantification of potato glycoalkaloids and their metabolites in aqueous soil extracts was developed. The LC-ESI-TOF-MS method had linearities up to 2000microg/L for alpha-solanine and alpha-chaconine and up to 760microg/L for solanidine. No matrix effect was observed, and the detection limits found were in the range 2.2-4.7microg/L. The method enabled quantification of the potato glycoalkaloids in environmental samples.  相似文献   

20.
Gas chromatography coupled with electron capture detector (GC-ECD) was successfully developed and applied for the rapid determination of acrylamide in conventional fried foods, such as potato crisps, potato chips, and fried chicken wings. The method included defatting with n-hexane, extraction with aqueous solution of sodium chloride (NaCl), derivatization with potassium bromate (KBrO3) and potassium bromide (KBr), and liquid-liquid extraction with ethyl acetate. The final acrylamide extract was analyzed by GC-ECD for quantification and by GC-MS for confirmation. The chromatographic analysis was performed on the HP-INNOWax capillary column, and good retention and peak response of acrylamide were achieved under the optimal conditions (numbers of theoretical plates N = 83,815). The limit of detection (LOD) was estimated to be 0.1 microg kg(-1) on the basis of ECD technique. Recoveries of acrylamide from conventional samples spiked at levels of 150, 500 and 1000 microg kg(-1) (n = 4 for each level) ranged between 87 and 97% with relative standard deviations (RSD) of less than 4%. Furthermore, the GC-ECD method showed that no clean-up steps of acrylamide derivative would be performed prior to injection and was slightly more sensitive than the MS/MS-based methods. Validation and quantification results demonstrated that this method should be regarded as a new, low-cost, and robust alternative for conventional investigation of acrylamide.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号