首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
《Analytical letters》2012,45(7):553-565
Abstract

Quadrupole mass spectral analysis of the volatile uranium ligand complex bis (1,1,1,5,5,5-hexafluoro-2,4 pentanedionato) dioxouranium-di-n-butyl sulfoxide is described utilizing electron impact (EI) and methane chemical ionization (CI) ion sources. All major ions are tentatively identified and the potential usefulness of this complex for determining uranium isotope 235U/238U abundance is demonstrated.  相似文献   

2.
The trace element Zn in the Zn-doped multi-layer ш - V group compound semiconductor was detected by means of Resonant Laser Ablation/lomzation(RLA). A detection limit of 2. 5 X 1017 atoms/cm3 (about 5 ppm) has been estimated. The mass spectra and the optical resonant ionization spectrum around 214 nm are given in this paper.  相似文献   

3.
论述了用激光解吸电离谱法分析富勒烯。因在电离过程中富勒分子不发生裂解,因此这种方法可直接用于富勒烯混合物的分析而勿需任何预分离。还给出了用本法分析较大、较稳定富勒烯分子的质谱图。  相似文献   

4.
研制了超声喷雾电离源(SSI)。采用核糖核酸A、溶菌酶等样品和商品化的线性离子阱质谱仪对该电离源进行了表征。实验发现,对于生物大分子,超声喷雾电离质谱(SSI-MS)能够获得与电喷雾质谱(ESI-MS)类似的多电荷离子。但与同等条件下ESI-MS所获得的谱图相比,SSI主要获得低价态的多电荷离子。在此基础上,系统考察了SSI-MS各主要操作参数对不同价态蛋白质多电荷离子信号强度的影响,并提出了SSI离子化的可能机理。结果表明,在喷雾气压3.4~3.6 MPa、喷雾口到质谱入口的距离4~6 mm、离子传输管温度250~300℃、样液流速50~100μL/min、2%~5%甲酸酸性且不含甲醇的条件下,各价态蛋白质离子信号强度及信号分布均达到最优;而离子传输管温度越高,喷雾压力越大或溶剂中甲醇等挥发性成分越高,则越有利于低价态离子的形成。  相似文献   

5.
Mass spectra of transition metal carbonyl cluster anions were recorded using laser desorption ionization time-of-flight (LDI-TOF) and electrospray ionization (ESI) techniques. The LDI spectra generally contain peaks corresponding the intact cluster together with extensive CO loss fragments ions whereas the ESI spectra exhibit peaks corresponding the intact cluster together with few (if any) CO loss fragment ions. The parameters of both techniques can be modified to vary the extent of fragmentation. In all cases no fragmentation of the metal core is observed. Overall, ESI is a more informative method for the analysis of these types of cluster anions.  相似文献   

6.
AnExplanationontheElectronIonizationMassSpectraofCrownEthersbyMNDOComputationalMethodYUANHu-shan,TANGMing-shengandWUYang-jie(...  相似文献   

7.
确定初始电离位点是EI源质谱解析中一个至关重要的环节. 本文提出了一种确定初始电离位点的新方法. 该法通过计算和分析分子离子自旋密度, 进而比较从中性分子到分子离子的电荷变化和键长变化, 从而确定初始电离位点. 对简单吲哚类生物碱质谱的特征裂解机理进行了预测, 结果与标准物质的质谱吻合. 在此基础上, 与传统的根据基团电离能确定电离位点的方法进行了比较. 结果表明, 该法优于电离能方法. 此法不仅可用于预测以α-裂解为主导的吲哚生物碱和其它含氮化合物的质谱裂解规律, 还为揭示其它小分子化合物以及气相多肽离子的裂解机理奠定了基础.  相似文献   

8.
An astonishingly simple new method to produce gas-phase ions of small molecules as well as proteins from the solid state under cold vacuum conditions is described. This matrix assisted ionization vacuum (MAIV) mass spectrometry (MS) method produces multiply charged ions similar to those that typify electrospray ionization (ESI) and uses sample preparation methods that are nearly identical to matrix-assisted laser desorption/ionization (MALDI). Unlike these established methods, MAIV does not require a laser or voltage for ionization, and unlike the recently introduced matrix assisted ionization inlet method, does not require added heat. MAIV-MS requires only introduction of a crystalline mixture of the analyte incorporated with a suitable small molecule matrix compound such as 3-nitrobenzonitrile directly to the vacuum of the mass spectrometer. Vacuum intermediate pressure MALDI sources and modified ESI sources successfully produce ions for analysis by MS with this method. As in ESI-MS, ion formation is continuous and, without a laser, little chemical background is observed. MAIV, operating from a surface offers the possibility of significantly improved sensitivity relative to atmospheric pressure ionization because ions are produced in the vacuum region of the mass spectrometer eliminating losses associated with ion transfer from atmospheric pressure to vacuum. Mechanistic aspects and potential applications for this new ionization method are discussed.   相似文献   

9.
敞开式电离质谱(Ambient ionization mass spectrometry,AIMS)是指在大气压环境下,无需或只需简单的样品前处理即可对样品中目标物进行分析的质谱技术.AIMS具有简单、快速、无损和适用范围广等优势,被广泛应用于法医毒物分析领域.该文对敞开式电离(Ambient ionization,A...  相似文献   

10.
采用柱切换高效液相色谱技术对人血清中的丹参素及其代谢产物进行富集和分离,利用对电喷雾离子阱多级质谱负离子模式进行结构分析。一级流动相为甲醇-水(30:70,V/V),流速0.8mL/min;二级流动相为甲醇-水-甲酸铵(15:85:0.5,V/V/V),流速0.2mL/min;在人血清中检测到丹参素及其代谢产物,并探讨了主要代谢产物乙酰化的丹参素(m/z 240.2)。建立一种复方丹参滴丸中丹参素及其代谢产物在人体内代谢过程的高效分析方法。该方法可用于复方丹参滴丸中丹参素及与其结构类似的其它药物的体内代谢研究。  相似文献   

11.
电喷雾解吸电离质谱法用于临床尿样的直接分析   总被引:2,自引:1,他引:2  
将电喷雾解吸电离质谱(DESI-MS)用于临床尿样的分析, 优化了电喷雾溶剂流速、电喷雾电压和喷雾锥距离等重要参数. 采用普通滤纸作为样品载体, 在不需要样品预处理的前提下同时快速测定了临床尿样中的钾、钠、尿素、尿酸、丙酮酸和肌苷等多种成分, 并对各种成分的主要离子进行了串联质谱鉴定. DESI-MS在进行多组分同时测定时不需要进行样品预处理, 缩短了测定时间, 单个样品的分析时间不到1 min. 同时, 采用内标法对所测定组分进行了半定量分析.  相似文献   

12.
13.
14.
电喷雾质谱在手性识别和分析中的应用   总被引:1,自引:0,他引:1  
近年来电喷雾质谱以其快速、灵敏、简便、样品用量少等特点被越来越多地应用于手性分析研究中。本文综述了目前电喷雾质谱法在手性识别和分析中的应用,包括常用的分析方法及常用的质谱手性选择剂,并对其发展进行了展望。  相似文献   

15.
16.
Atmospheric pressure chemical ionization (APCI)-mass spectrometry (MS) and electrospray ionization (ESI)-MS can cover the analysis of analytes from low to high polarities. Thus, an ion source that possesses these two ionization functions is useful. Atmospheric surface-assisted ionization (ASAI), which can be used to ionize polar and nonpolar analytes in vapor, liquid, and solid forms, was demonstrated in this study. The ionization of analytes through APCI or ESI was induced from the surface of a metal substrate such as a titanium slab. ASAI is a contactless approach operated at atmospheric pressure. No electric contacts nor any voltages were required to be applied on the metal substrate during ionization. When placing samples with high vapor pressure in condensed phase underneath a titanium slab close to the inlet of the mass spectrometer, analytes can be readily ionized and detected by the mass spectrometer. Furthermore, a sample droplet (~2 μL) containing high-polarity analytes, including polar organics and biomolecules, was ionized using the titanium slab. One titanium slab is sufficient to induce the ionization of analytes occurring in front of a mass spectrometer applied with a high voltage. Moreover, this ionization method can be used to detect high volatile or polar analytes through APCI-like or ESI-like processes, respectively.  相似文献   

17.
电喷雾质谱对洗发水中多种表面活性剂的快速分析   总被引:1,自引:0,他引:1  
利用电喷雾离子化质谱技术(ESIMS)快速鉴定了洗发水中的常用表面活性剂。在流动注射进样方式下,鉴定出所测试洗发水中含有2种主要表面活性剂:烷基单乙醇酰胺(CMEA)和脂肪醇聚氧乙烯十二烷基醚硫酸钠(SLES·nEO)。进一步通过高效液相色谱与质谱联用(HPLC—MS)利用ESI^+和ESI^-之间的切换完成对不同类型表面活性剂的定量检测,测定出该洗发水中CMEA的使用量为1.198%(质量分数),与实际添加量1.2%非常吻合。运用HPLC—MS对SLES·nEO在洗发水中的种类结构进行了鉴定。  相似文献   

18.
We explore the feasibility of conducting electron ionization (EI) in a radio-frequency (rf) ion source trap for mass spectrometry applications. Electrons are radially injected into a compact linear ion trap in the presence of a magnetic field used essentially to lengthen the path of the electrons in the trap. The device can either be used as a stand-alone mass spectrometer or can be coupled to a mass analyzer. The applied parallel magnetic field and the oscillating rf electric field produced by the trap give rise to a set of coupled Mathieu equations of motion. Via numerical simulations, electron trajectories are studied under varying intensities of the magnetic field in order to determine the conditions that enhance ion production. Likewise, the dynamic behavior of the ions are investigated in the proposed EI source trap and the fast Fourier transform FFT formalism is used to obtain the frequency spectrum from the numerical simulations to study the motional frequencies of the ions which include combinations of the low-frequency secular and the high-frequency micromotion with magnetron and cyclotron frequencies. The dependence of these motional frequencies on the trapping conditions is examined and particularly, the limits of applying a radial magnetic field to the EI ion trap are characterized.
Figure
?  相似文献   

19.
Despite many potential applications, miniature mass spectrometers have had limited adoption in the field due to the tradeoff between throughput and resolution that limits their performance relative to laboratory instruments. Recently, a solution to this tradeoff has been demonstrated by using spatially coded apertures in magnetic sector mass spectrometers, enabling throughput and signal-to-background improvements of greater than an order of magnitude with no loss of resolution. This paper describes a proof of concept demonstration of a cycloidal coded aperture miniature mass spectrometer (C-CAMMS) demonstrating use of spatially coded apertures in a cycloidal sector mass analyzer for the first time. C-CAMMS also incorporates a miniature carbon nanotube (CNT) field emission electron ionization source and a capacitive transimpedance amplifier (CTIA) ion array detector. Results confirm the cycloidal mass analyzer’s compatibility with aperture coding. A >10× increase in throughput was achieved without loss of resolution compared with a single slit instrument. Several areas where additional improvement can be realized are identified.
Graphical Abstract ?
  相似文献   

20.
A simple design for an open port sampling interface coupled to electrospray ionization (OPSI-ESI) is presented for the analysis of organic aerosols. The design uses minimal modifications to a Bruker electrospray (ESI) emitter to create a continuous flow, self-aspirating open port sampling interface. Considerations are presented for introducing aerosol to the open port sampling interface including aerosol gas flow and solvent flow rates. The device has been demonstrated for use with an aerosol of nicotine as well as aerosol formed in the pyrolysis of biomass. Upon comparison with extractive electrospray ionization (EESI), this device has similar sensitivity with increased reproducibility by nearly a factor of three. The device has the form factor of a standard Bruker/Agilent ESI emitter and can be used without any further instrument modifications.
Graphical Abstract ?
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号