共查询到20条相似文献,搜索用时 15 毫秒
1.
Hye Won Lee Hye Young Ji Hui Hyun Kim Il Kwang Kim Soon Hoe Kim Won Bae Kim Hye Suk Lee 《Chromatographia》2004,59(7-8):425-428
A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric method (LC-MS-MS) for the determination of eupatilin in human plasma has been developed. Eupatilin and an internal standard; (S)-N-(3-{3-fluoro-4-[6-(1-methyl-1H-tetrazol-5-yl)-pyridine-3-yl]-phenyl}-2-oxo-oxazolidin-5-ylmethyl)-acetamide (DA-7867) were extracted from human plasma by liquid-liquid extractionand analyzed on a phenyl-hexyl column using the mobile phase: acetonitrile-ammonium formate (10 mM, pH 3.0) (60:40, /). Analytes were detected using electrospray ionization-tandem mass spectrometry in multiple-reaction monitoring mode. The calibration curve was linear (r = 0.999) over the concentration range: 1.00–500 ng mL–1 with a lower limit of quantification of 1.0 ng mL–1 using a 100 L plasma sample. The precision (CV%) of this assay ranged: 2.4–7.0%, relative error: –7.0 to +2.0%. Recoveries of eupatilin ranged: 64.3–65.0%, with that of DA-7867 (internal standard) being 87.0 ± 5.3%. 相似文献
2.
《Analytical letters》2012,45(14):2317-2331
The genus Stellaria (Caryophyllaceae) presents widely distributed plants often used in traditional medicine. Flavonoids are highly active plant secondary metabolites that may be involved in some of the effects of Stellaria plants. In this study, two new high-performance liquid chromatography–electrospray ionization tandem mass spectrometry (HPLC–ESI-MS-MS) methods were developed for the determination of flavonoids and isoflavonoids in plant material. The separations were performed on a reverse-phase C18 column with gradient elution using methanol and water with 0.5% acetic acid as the mobile phase. Multiple reaction monitoring was used for the tandem mass spectrometry detection and the two most intensive transitions were chosen for the identification of each analyte. The limits of detection and the limits of quantification were between 0.2 and 15.0 ng/mL and 0.6 and 50.0 ng/mL. The developed methods were successfully used for the analyses of four representatives of the genus Stellaria. All the studied herbs contained luteolin and its 7-O-glycosides, naringenin, kaempferol, quercetin, its glycoside rutin, apigenin, and its 7-O-glycoside. One coumarin, scopoletin, was also found. Isoflavones were primarily represented by genistein, genistin, and ononin. Some of the analytes were detected for the first time in Stellaria sp. The findings support that these methods are suitable for analyses of plant material. 相似文献
3.
《Analytical letters》2012,45(13):1979-1987
Liquid chromatography with tandem mass spectrometry was used for the determination of nitrofurantoin, nitrofurazone, furazolidone, and furaltadone in chicken feed. The nitrofurans were extracted with phosphate buffer (pH 7) and sodium chloride. Proteins and lipids were removed with acetonitrile and hexane before purification with ethyl acetate, dilution in 1:1 acetonitrile-5 millimolar ammonium acetate at pH 7.3, and filtration prior to analysis. The limits of detection were 1.69, 1.74, 2.01, and 1.45 microgram per kilogram for nitrofurantoin, nitrofurazone, furazolidone, and furaltadone, respectively. The mean recoveries were between 84.6 and 110.6 percent. The method was employed to determine nitrofurans in chicken feed. 相似文献
4.
《Analytical letters》2012,45(10):1634-1649
A selective method for the determination of fourteen nitroimidazoles and their hydroxy-metabolites in honey was developed based on improved molecularly imprinted solid-phase extraction followed by liquid chromatography–tandem mass spectrometry. The separation of analytes was performed on a C18 column using a mobile phase of 0.1% formic acid in acetonitrile and 0.1% formic acid in water with gradient elution. The method was suitable for metronidazole, hydroxymetronidazole, dimetridazole, ronidazole, hydroxydimetridazole, ipronidazole, hydroxyipronidazole, carnidazole, menidazole, nimorazole, ornidazole, secnidazole, ternidazole, and tinidazole. The procedure was evaluated according to EU Commission Decision 2002/657/EC requirements by determining linearity, specificity, recovery, repeatability, within-laboratory reproducibility, decision limit, detection capability, matrix effects, and stability. The method determined nitroimidazoles and their hydroxy-metabolites below the recommended concentration level of 3 µg kg?1. The decision limits and detection capabilities ranged from 0.110 µg kg?1 to 0.387 µg kg?1 and from 0.179 µg kg?1 to 0.508 µg kg?1, respectively. The results from stability tests indicated that all analyzed nitroimidazoles were stable in honey stored at 4°C for at least 28 weeks and that elevated temperature and exposure to light exposure accelerated their degradation. The method was successfully applied to the analysis of a wide variety of honey samples. 相似文献
5.
High-performance liquid chromatography coupled with high-resolution mass spectrometry was used for the determination of polyphenols in Lycium barbarum leaves. Twenty compounds extracted by methanol–water were tentatively identified that included chlorogenic acids, flavonoids, and phenolic acids. Neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid, isochlorogenic acid B, isochlorogenic acid A, and isochlorogenic acid C were identified in Chinese cultivated L. barbarum leaves for the first time. Caffeic acid and isoquercitrin were also present. The concentrations of these compounds in L. barbarum leaves were determined. The results showed that all analytes had linear calibration relationships with limits of detection from 0.318 to 3.35?ng mL?1. The polyphenols and flavonoids in L. barbarum leaves provided strong 2,2-diphenyl-1-picrylhydrazyl radical-scavenging capacity (IC50 of 23.1?±?0.4 to 26.0?±?0.4?µg mL?1). This method is suitable for the determination of polyphenols in L. barbarum leaves, which provide polyphenols with suitable antioxidant activity. 相似文献
6.
An indirect method is described for determination of phytate in human urine. The method is based on hydrolysis of the phytate and determination of myo-inositol, one of the hydrolysis products. Chromatographic separations were performed on an Aminex HPX-87C column with Milli-Q water as mobile phase; 5 mM ammonium acetate was added post-column. The detector counted positive ions by monitoring m/z=198, which corresponds to the adduct of myo-inositol with the ammonium cation. The relative standard deviations obtained for standards containing 0.5, 1, and 1.5 mg L–1 phytate were 4.1, 3.0, and 2.7% respectively (n=5). The limit of detection was 60 g L–1. Different urine samples were analyzed both by this method and by an alternative analytical method based on GC–MS. The results from both methods were comparable. 相似文献
7.
《Analytical letters》2012,45(14):2307-2316
A facile method based on liquid chromatography coupled with triple quadrupole mass spectrometry was established to determine floridoside and isofloridoside in red algae. Correlation coefficients of the calibration curves were larger than 0.9989, indicated good linearity. Detection limits of floridoside and isofloridoside were 0.05 and 0.20 ng/mL, respectively, and the limits of quantification were 0.1 and 0.4 ng/mL. The recoveries varied from 75.7% to 76.8%, and relative standard deviations of inter-day and intra-day precision were lower than 8.5% (n = 5). The effects of sea level variations in the intertidal zone on the osmotic role of floridoside and isofloridoside concentrations in seven red algae were investigated. It was shown that algae that inhabit higher levels in the intertidal zone contained higher concentrations of floridoside and isofloridoside. The results suggest that the presence of direct sun, exposure time, and temperature influenced to the concentrations of floridoside and isofloridoside due to the osmotic pressure adjustments. 相似文献
8.
《Analytical letters》2012,45(13):2071-2086
Abstract A rapid, simple, and specific liquid chromatography–electrospray ionization–mass spectrometric method has been developed and validated for the determination of fluoxetine in human plasma. The method was validated with a linear range of 0.5–100 ng mL?1, and the lowest limits of quantification were 0.5 ng mL?1 for fluoxetine. The extraction efficiencies were about 65% and recoveries of method were in the range of 94.0–97.5%. The intraday relative standard deviation (RSD) was less than 11% and interday RSD was within 12%. The method has been successfully applied to the evaluation of pharmacokinetics and bioequivalence of fluoxetine. 相似文献
9.
Voriconazole is used to prevent invasive pulmonary aspergillosis. However, little is known about the concentrations of voriconazole in human lung epithelial cells (A549), which is the target for preventing invasive pulmonary aspergillosis. The goal of this study was to develop a high-performance liquid chromatography–tandem mass spectrometry method to quantify voriconazole in A549 cells. A triple-quadrupole mass spectrometer in selected reaction monitoring mode was used with positive electrospray ionization. The total duration of each run was 5?min. The calibration curves fit a least squares model for the voriconazole concentration ranging from 0.625 to 160?ng/mL. Intraday and interday coefficients of variation were less than 10%. Recoveries at the concentrations of the quality control samples where greater than 85%, and the matrix effects showed that the ratios of the peak response exhibited a 15% suppression of the signal in the matrix compared to water. Voriconazole may penetrate A549 cells. However, the voriconazole uptake was slow in A549 cells, reaching a plateau at 2?h, where the dose-dependent intracellular voriconazole concentrations were 1.98?±?0.38, 4.43?±?0.54, and 8.14?±?0.52?ng/mg protein for extracellular voriconazole concentrations of 5, 10, and 20?µg/mL, respectively. The uptake of voriconazole by A549 cells was linear at extracellular concentrations from 0 to 20?µg/mL. This study established a rapid and sensitive method suitable for determining voriconazole in A549 cells and described the kinetic properties of the absorption of voriconazole by A549 cells. 相似文献
10.
Xia Li Bin Liu Fengen Wang Xinfeng Ma Zengmei Li Dongliang Guo 《Analytical letters》2018,51(5):702-716
An ultrahigh-performance liquid chromatography–tandem mass spectrometry method was developed and validated for the simultaneous determination of sterigmatocystin, verruculogen, enniatin A, fusarenon-X, fumonisins B1, B2, B3, aflatoxins B1, B2, G1, G2, ochratoxin A, deoxynivalenol, 3-acetyldeoxynivalenol, 5-acetyldeoxynivalenol, and zearalenone. The mycotoxins were extracted and cleaned up using a multitoxin column, separated on a C18 column, and then detected on a triple-quadrupole mass spectrometer. The limits of detection and quantification ranged within 0.2–2?µg/kg and 1–10?µg/kg, respectively. The recoveries ranged from 70.8 to 118.4%, with relative standard deviations below 15%. The method was used to analyze 80 samples obtained from Shandong Province in China. Fifty-eight samples were contaminated with 10 mycotoxins at concentrations ranging from 1.4 to 6566.1?µg/kg. Some samples exceeded the maximum limits in China and in European regulations for mycotoxins in unprocessed maize. 相似文献
11.
《Analytical letters》2012,45(14):2157-2169
Abstract A rapid, sensitive, and specific liquid chromatography–tandem mass spectrometric (HPLC-MS/MS) method has been developed for quantification of ferulic acid in rat plasma. The analyte and docetaxel (internal standard) were extracted from plasma samples with diethyl ether and analyzed on a C18 column. The chromatographic separation was achieved within 3.5 min by using acetonitrile-water as the mobile phase and the flow rate was 0.2 mL · min?1. The method was linear within the range of 0.5 ? 800 ng · mL?1. The lower limit of quantification (LLOQ) was 0.5 ng · mL?1. Finally, the method is successfully applied for the pharmacokinetic study of ferulic acid in rats following intravenous administration. 相似文献
12.
Csilla Mišľanová Jana Príbojová Martina Valachovičová Zuzana Žilinská 《Analytical letters》2017,50(15):2359-2368
Cyclosporine, tacrolimus, sirolimus, and everolimus are commonly used immunosuppressants following organ transplantation. Their monitoring is used to determine the optimal dose for therapeutic effectiveness and minimize toxicity. High-performance liquid chromatographic–tandem mass spectrometry with positive electrospray ionization and multiple reaction monitoring mode was validated for the determination of cyclosporine A, tacrolimus, sirolimus, and everolimus in whole blood. A C18 analytical column was employed with a gradient elution of pH 4.0 aqueous 10?mmol/L ammonium acetate and acetonitrile. For the pretreatment of whole blood, simple protein precipitation was used with methanol:zinc sulfate. The calibration curves were linear from 20.0 to 1000?ng/mL for cyclosporine A, 1.0 to 50?ng/mL for tacrolimus and sirolimus, and 1.0 to 30?ng/mL for everolimus. The intra-assay precision and inter-assay precision were less than 15%. The method provides reliable and reproducible results according to the linearity, precision, accuracy, recovery, and matrix effects. The method has been introduced to routine clinical practice in Slovakia for the determination of immunosuppressants in patients after kidney transplantation. 相似文献
13.
《Analytical letters》2012,45(11):1862-1873
High performance liquid chromatography coupled with electrospray ionization quadrupole-time-of-flight tandem mass spectrometry was used to profile the phenylethanoid glycosides in Lagotis brevituba. A total of twenty-three phenylethanoid glycosides were characterized by comparing the retention time and fragmentation with standards, accurate mass measurements, and fragmentation at low and high collision energies. Most phenylethanoid glycosides were reported in L. brevituba for the first time. This established method may be employed for comprehensive quality control of L. brevituba. 相似文献
14.
《Analytical letters》2012,45(6):934-943
Infant formula provides a good source of fructooligosaccharides, which are considered to be functional ingredients of food due to their positive effects on gastrointestinal function. This study presents a simple and specific ultra-high performance liquid chromatography–tandem mass spectrometry method for the ultrasensitive determination of three fructooligosaccharides in infant formula. The analytes were extracted using acetonitrile-water solutions. The compounds were separated with an amide column by gradient elution using acetonitrile and water as mobile phases. The identification and quantification were achieved by using electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring. Accuracy, precision, limits of quantification, and limits of detection of the method were obtained. Under the optimal conditions, all calibration curves for fructooligosaccharides targets showed good linearity (R2 ≥ 0.998). The limits of detection and quantification were below 0.82 and 2.74 ng mL?1, respectively. The recoveries of the method ranged from 98.5% to 104.4%. To the knowledge of the authors, this is the first quantitative determination of fructooligosaccharides in infant formula by ultra-high performance liquid chromatography–tandem mass spectrometry. The method may be suitable for the determination of trace concentrations of fructooligosaccharides in other food. 相似文献
15.
《Analytical letters》2012,45(14):2288-2302
Polyacrylate stir bar sorptive extraction (SBSE) of 2,6-dichlorobenzamide followed by liquid desorption and analysis by liquid chromatography–tandem mass spectrometry using electrospray ionization is presented. The parameters influencing the methods were optimized and included a stirring speed of 500 revolutions per minute, an extraction time of two hours, a sample volume of 15 milliliters, 30 percent NaCl, and liquid desorption using acetonitrile under ultrasonication for fifteen minutes. A reverse phase C18 column was used with isocratic elution (50 percent acetonitrile and 50 percent 5 millimoles per liter aqueous ammonium acetate buffer at pH 2.4), a flow rate of 0.4 milliliter per minute, and an injection volume of 10 microliters. Quantitative analysis was carried out by multiple reaction monitoring using positive polarity. The developed method required low sample volume (15 milliliters) and provided satisfactory figures of merit with a limit of detection of 0.002 microgram per liter, a limit of quantification of 0.006 microgram per liter, and good precision (inter-day relative standard deviation below 10 percent). The polyacrylate Twister was employed for up to twenty-five extraction and liquid desorption cycles. The applicability of the method was assessed by analyzing ground water collected at five sites in North Italy. The concentrations of 2,6-dichlorobenzamide were between 0.070 and 0.282 microgram per liter. Preliminary results on the use of polar stir bars for the determination of other polar pesticides in water are also provided. 相似文献
16.
《Analytical letters》2012,45(16):2639-2649
The rapid speciation of lead is reported by high performance liquid chromatography and inductively coupled plasma – mass spectrometry. The separation of inorganic lead, trimethyllead, triethyllead and triphenyllead was achieved within 3.5 minutes on a C18 column using a gradient program of methanol and water containing 5 milligrams per liter sodium 1-pentanesulfonate at pH 5. The limits of detection for inorganic lead, trimethyllead, triethyllead, and triphenyllead were 0.01, 0.02, 0.02, and 0.02 micrograms per liter, respectively. The accuracy of the method was verified by the analysis of water (GSBZ 50009-88) and seawater (GBW (E) 080040) certified reference materials. The method was also employed for the analysis of water samples; inorganic lead was measured in river water. 相似文献
17.
An analytical method was established to simultaneously quantify flonicamid and its metabolites 4-trifluoromethylnicotinic acid (TFNA), N-(4-trifluoromethylnicotinoyl) glycine (TFNG), and 4-trifluoromethylnicotinamide (TFNA-AM) in tea using orthogonal experimental design and liquid chromatography–tandem mass spectrometry (LC–MS/MS). Residues were extracted from the samples with acetonitrile containing 1% acetic acid and were purified with graphitized carbon black. The linearity of the method was excellent in the concentration range of 0.01–10?µg/mL, producing correlation coefficients greater than 0.996 for the target compounds. The limits of detection and quantification of all analytes in tea were 0.0013–0.013?mg/kg and 0.004–0.040?mg/kg, respectively. The average recoveries of flonicamid, TFNA, TFNG, and TFNA-AM ranged from 75.14 to 92.72%, with intra- and interday relative standard deviations of 1.07–9.75%. The proposed method was successfully applied to the terminal residue determination of flonicamid and its metabolites in dry tea processed from three field trials’ fresh samples. The determined total terminal residue concentrations of flonicamid 10?days after the last application at all three sites were below the maximum residue limit (MRL) set by the European Union (0.1?mg/kg) and the residues in all samples were lower than the MRL established by the United States Environmental Protection Agency (EPA) (8?mg/kg). This method may be used to meet the requirements for the determination of flonicamid and its metabolites that could provide guidance for establishing a MRL for flonicamid in tea in China. 相似文献
18.
Antibiotics are often used in bee-keeping to control European and American foulbrood. The broad spectrum antibiotic chloramphenicol (CAP) was used for curative purposes in veterinary medicine, but is now forbidden in numerous countries, although still used in south-east Asia. A liquid-chromatographic method with tandem mass spectrometric detection (LC–MS–MS) has been developed for analysis of sub-g kg–1 residues of chloramphenicol in honey. Results from full validation of the procedure and analysis of 75 honey samples obtained commercially in Switzerland are presented. These show the method is satisfactory and useful for monitoring chloramphenicol residues in honey. 相似文献
19.
Multivariate response surface methodology optimization using Placket–Burman and Box–Behnken designs were respectively used for the screening and optimization of significant factors for liquid chromatography–tandem mass spectrometry. Consequently, the optimized instrument successfully improved the sample preparation protocol and the method was validated. However, modified QuEChERS dispersive solid phase extraction coupled with ionic liquid-based dispersive liquid–liquid microextraction were used for the determination of multi-pesticide residues in fruit and vegetable samples. The analysed samples were jackfruit, strawberries, cucumber, pears, and carrots. The resulting linearity range (5–400?µg/kg) and regression coefficient (>0.99) results were satisfactory. The 94.2 and 95.8% accuracy (89–138%) and precision (0–25%) results were satisfactory and within the recommended ranges (≤20%) and (70–120%), respectively. The limits of detection (0.01–0.54?µg/kg) and quantitation (0.03–1.79?µg/kg) were excellent. The matrix effects (≤?87%) for all analysed samples were not significant. The estimated measurement uncertainties (≤27%) were within the acceptable range (≤50%). Justifiably, the response surface methodology optimized instrument and sample treatment techniques were reliable and convenient for multi-pesticide residue determination in various fruits and vegetables. 相似文献
20.
Chlorophenols are a category of toxic pollutants that are ubiquitously present in the environment. This paper presents a reliable and feasible method for the determination of five chlorophenols in sewage sludge and soil using liquid chromatography–tandem mass spectrometry (LC-MS/MS). The pretreatment involved ultrasonic-assisted extraction and solid-phase extraction purification with hydrophilic–lipophilic balance cartridges. LC-MS/MS equipped with an electrospray ionization source operated in negative mode was used for detection, and multitude reaction monitoring mode was applied for data acquisition. The pretreatment and working conditions of LC-MS/MS were optimized to achieve satisfactory results. The intra-batch accuracies were 100.5–113.4% with relative standard deviations?≤?15.6% for the chlorophenols in sewage sludge and 71.3–102.7% with relative standard deviations?≤?14.0% for those in soil. The inter-batch accuracies were 86.1–100.5% (relative standard deviations?≤?33.6%) for sewage sludge samples and 70.5–112.5% (relative standard deviations?≤?28.2%) for soil samples, respectively. This method has been applied to the determination of chlorophenols in sewage sludge of wastewater treatment plants and soil collected from Guangzhou, China. Parachlorophenol, 2,4,6-trichlorophenol, 2,3,4,6-tetrachlorophenol, and pentachlorophenol were detected in some sewage sludge samples, with concentrations from 0.51 to 13.20?ng/g. In addition, parachlorophenol, 2,3,4,6-tetrachlorophenol, and pentachlorophenol were found in all the soil samples with concentrations from 0.33 to 5.21?ng/g. The chromatographic behavior, on-filter adsorption behavior, and the relationship between optimal collision energies and degree of chlorination of the chlorophenols was investigated. This method will be conducive to environmental research focusing on pollution investigation of chlorophenols in the environment. 相似文献