首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A hard X‐ray transparent triaxial deformation apparatus, called HADES, has been developed by Sanchez Technologies and installed on the microtomography beamline ID19 at the European Radiation Synchrotron Facility (ESRF). This rig can be used for time‐lapse microtomography studies of the deformation of porous solids (rocks, ceramics, metallic foams) at conditions of confining pressure to 100 MPa, axial stress to 200 MPa, temperature to 250°C, and controlled aqueous fluid flow. It is transparent to high‐energy X‐rays above 60 keV and can be used for in situ studies of coupled processes that involve deformation and chemical reactions. The rig can be installed at synchrotron radiation sources able to deliver a high‐flux polychromatic beam in the hard X‐ray range to acquire tomographic data sets with a voxel size in the range 0.7–6.5 µm in less than two minutes.  相似文献   

2.
A series of computed microtomography experiments are reported which were performed by using a third‐generation synchrotron radiation source on volcanic rocks from various active hazardous volcanoes in Italy and other volcanic areas in the world. The applied technique allowed the internal structure of the investigated material to be accurately imaged at the micrometre scale and three‐dimensional views of the investigated samples to be produced as well as three‐dimensional quantitative measurements of textural features. The geometry of the vesicle (gas‐filled void) network in volcanic products of both basaltic and trachytic compositions were particularly focused on, as vesicle textures are directly linked to the dynamics of volcano degassing. This investigation provided novel insights into modes of gas exsolution, transport and loss in magmas that were not recognized in previous studies using solely conventional two‐dimensional imaging techniques. The results of this study are important to understanding the behaviour of volcanoes and can be combined with other geosciences disciplines to forecast their future activity.  相似文献   

3.
A compact transmission X‐ray microscope has been designed and implemented based on a cylindrical symmetry around the optical axis that sharply limits the instabilities due to thermal mechanical drift. Identical compact multi‐axis closed‐loop actuation modules drive different optical components. The design is modular and simplifies the change of individual parts, e.g. the use of different magnification and focusing devices. This compact instrument can be easily transported between laboratory and synchrotron facilities and quickly put into operation. An automated alignment mechanism simplifies the assembly of different modules after transportation. After describing the design details, the results of the first tests are presented.  相似文献   

4.
A miniature (1 ml volume) reaction cell with transparent X‐ray windows and laser heating of the sample has been designed to conduct X‐ray absorption spectroscopy studies of materials in the presence of gases at atmospheric pressures. Heating by laser solves the problems associated with the presence of reactive gases interacting with hot filaments used in resistive heating methods. It also facilitates collection of a small total electron yield signal by eliminating interference with heating current leakage and ground loops. The excellent operation of the cell is demonstrated with examples of CO and H2 Fischer–Tropsch reactions on Co nanoparticles.  相似文献   

5.
Hydrothermal formation of tobermorite from a pre‐cured cake has been investigated by transmission X‐ray diffraction (XRD) using high‐energy X‐rays from a synchrotron radiation source in combination with a newly designed autoclave cell. The autoclave cell has a large and thin beryllium window for wide‐angle X‐ray diffraction; nevertheless, it withstands a steam pressure of more than 1.2 MPa, which enables in situ XRD measurements in a temperature range of 373 to 463 K under a saturated steam pressure. Formation and/or decomposition of several components has been successfully observed during 7.5 h of reaction time. From the intensity changes of the intermediate materials, namely non‐crystalline C–S–H and hydroxylellestadite, two pathways for tobermorite formation have been confirmed. Thus, the newly developed autoclave cell can be used for the analyses of reaction mechanisms under specific atmospheres and temperatures.  相似文献   

6.
A cell for the investigation of interfaces under pressure is presented. Given the pressure and temperature specifications of the cell, P≤ 100 bar and 253 K ≤T≤ 323 K, respectively, high‐energy X‐rays are required to penetrate the thick Al2O3 windows. The CH4(gas)/H2O(liquid) interface has been chosen to test the performance of the new device. The measured dynamic range of the high‐energy X‐ray reflectivity data exceeds 10?8, thereby demonstrating the validity of the entire experimental set‐up.  相似文献   

7.
O K‐edge and Co L‐edge near‐edge X‐ray absorption fine structure has been used to examine the cathode of an intact solid‐state lithium ion battery. The novel technique allowed for the simultaneous acquisition of partial electron yield and fluorescence yield data during the first charge cycle of a LiCoO2‐based battery below the intercalation voltage. The chemical environments of oxygen and cobalt at the surface are shown to differ chemically from those in the bulk. The present design enables a wide variety of in situ spectroscopies, microscopies and scattering techniques.  相似文献   

8.
The developed curved image plate (CIP) is a one‐dimensional detector which simultaneously records high‐resolution X‐ray diffraction (XRD) patterns over a 38.7° 2θ range. In addition, an on‐site reader enables rapid extraction, transfer and storage of X‐ray intensity information in ≤30 s, and further qualifies this detector to study kinetic processes in materials science. The CIP detector can detect and store X‐ray intensity information linearly proportional to the incident photon flux over a dynamical range of about five orders of magnitude. The linearity and uniformity of the CIP detector response is not compromised in the unsaturated regions of the image plate, regardless of saturation in another region. The speed of XRD data acquisition together with excellent resolution afforded by the CIP detector is unique and opens up wide possibilities in materials research accessible through X‐ray diffraction. This article presents details of the basic features, operation and performance of the CIP detector along with some examples of applications, including high‐temperature XRD.  相似文献   

9.
Phase‐contrast synchrotron X‐ray microtomography (pcSyncX) based on the highly coherent X‐ray beam has previously been used to visualize the microstructures of biologic specimens, but it has never been used to evaluate embolic debris adherent on a cerebral protection device (CPD). The purpose of this study was to demonstrate the feasibility of pcSyncX for evaluating embolic debris during carotid artery stenting (CAS). Five patients (four males, age range 67–77 years) with severe carotid artery stenosis underwent CAS. The retrieved CPD was exposed to synchrotron radiation and 1000 pcSyncX projection images were obtained by rotating the CPD through 180°. An X‐ray shadow of a CPD was converted into a visual image by the scintillator. After microtomographic reconstruction, the three‐dimensionally reconstructed images were further segmented into the embolic debris and CPD. The total volume of emboli was calculated by summing the volume at each scanning level. The number of membrane pores covered by emboli as seen from the outer surface was counted and the percentage of covered area was calculated. Embolic debris was clearly demonstrated not only on the inner surface and within pores but also on the outer surface of the CPD. The mean total volume of embolic debris was 0.538 × 10–6 mm3 (range 0.225–0.965 × 10–6 mm3). Most (61.5%) of the debris was located at the apical one‐third of the CPD and 20.8% of the pore area was covered by debris.  相似文献   

10.
A compact portable vacuum‐compatible chamber designed for surface X‐ray scattering measurements on beamline ID01 of the European Synchrotron Radiation Facility, Grenoble, is described. The chamber is versatile and can be used for in situ investigation of various systems, such as surfaces, nanostructures, thin films etc., using a variety of X‐ray‐based techniques such as reflectivity, grazing‐incidence small‐angle scattering and diffraction. It has been conceived for the study of morphology and structure of semiconductor surfaces during ion beam erosion, but it is also used for the study of surface oxidation or thin film growth under ultra‐high‐vacuum conditions. Coherent X‐ray beam experiments are also possible. The chamber is described in detail, and examples of its use are given.  相似文献   

11.
This paper describes the design, construction and implementation of a relatively large controlled‐atmosphere cell and furnace arrangement. The purpose of this equipment is to facilitate the in situ characterization of materials used in molten salt electrowinning cells, using high‐energy X‐ray scattering techniques such as synchrotron‐based energy‐dispersive X‐ray diffraction. The applicability of this equipment is demonstrated by quantitative measurements of the phase composition of a model inert anode material, which were taken during an in situ study of an operational Fray–Farthing–Chen Cambridge electrowinning cell, featuring molten CaCl2 as the electrolyte. The feasibility of adapting the cell design to investigate materials in other high‐temperature environments is also discussed.  相似文献   

12.
Core–shell X‐ray emission spectroscopy (XES) is a valuable complement to X‐ray absorption spectroscopy (XAS) techniques. However, XES in the hard X‐ray regime is much less frequently employed than XAS, often as a consequence of the relative scarcity of XES instrumentation having energy resolutions comparable with the relevant core‐hole lifetimes. To address this, a family of inexpensive and easily operated short‐working‐distance X‐ray emission spectrometers has been developed. The use of computer‐aided design and rapid prototype machining of plastics allows customization for various emission lines having energies from ~3 keV to ~10 keV. The specific instrument described here, based on a coarsely diced approximant of the Johansson optic, is intended to study volume collapse in Pr metal and compounds by observing the pressure dependence of the Pr Lα emission spectrum. The collection solid angle is ~50 msr, roughly equivalent to that of six traditional spherically bent crystal analyzers. The miniature X‐ray emission spectrometer (miniXES) methodology will help encourage the adoption and broad application of high‐resolution XES capabilities at hard X‐ray synchrotron facilities.  相似文献   

13.
A systematic study is presented in which multilayers of different composition (W/Si, Mo/Si, Pd/B4C), periodicity (from 2.5 to 5.5 nm) and number of layers have been characterized. In particular, the intrinsic quality (roughness and reflectivity) as well as the performance (homogeneity and coherence of the outgoing beam) as a monochromator for synchrotron radiation hard X‐ray micro‐imaging are investigated. The results indicate that the material composition is the dominating factor for the performance. By helping scientists and engineers specify the design parameters of multilayer monochromators, these results can contribute to a better exploitation of the advantages of multilayer monochromators over crystal‐based devices; i.e. larger spectral bandwidth and high photon flux density, which are particularly useful for synchrotron‐based micro‐radiography and ‐tomography.  相似文献   

14.
The multipurpose portable ultra‐high‐vacuum‐compatible chamber described in detail in this article has been designed to carry out grazing‐incidence X‐ray scattering techniques on the BM25‐SpLine CRG beamline at the ESRF. The chamber has a cylindrical form, built on a 360° beryllium double‐ended conflate flange (CF) nipple. The main advantage of this chamber design is the wide sample temperature range, which may be varied between 60 and 1000 K. Other advantages of using a cylinder are that the wall thickness is reduced to a minimum value, keeping maximal solid angle accessibility and keeping wall absorption of the incoming X‐ray beam constant. The heat exchanger is a customized compact liquid‐nitrogen (LN2) continuous‐flow cryostat. LN2 is transferred from a storage Dewar through a vacuum‐isolated transfer line to the heat exchanger. The sample is mounted on a molybdenum support on the heat exchanger, which is equipped with a BORALECTRIC heater element. The chamber versatility extends to the operating pressure, ranging from ultra‐high vacuum (<10?10 mbar) to high pressure (up to 3 × 103 mbar). In addition, it is equipped with several CF ports to allocate auxiliary components such as capillary gas‐inlet, viewports, leak valves, ion gun, turbo pump, etc., responding to a large variety of experiment requirements. A movable slits set‐up has been foreseen to reduce the background and diffuse scattering produced at the beryllium wall. Diffraction data can be recorded either with a point detector or with a bi‐dimensional CCD detector, or both detectors simultaneously. The system has been designed to carry out a multitude of experiments in a large variety of environments. The system feasibility is demonstrated by showing temperature‐dependence grazing‐incidence X‐ray diffraction and conductivity measurements on a 20 nm‐thick La0.7Ca0.3MnO3 thin film grown on a SrTiO3(001) substrate.  相似文献   

15.
A facile heating cell has been designed for in situ transmittance and fluorescence X‐ray absorption spectroscopy (XAS) measurements up to 1273 K under vacuum or an inert atmosphere. These high temperatures are achieved using a tantalum heating element by ohmic heating. Because of the small specific heat capacity, the temperature can be changed in a matter of minutes from room temperature to high temperature. Furthermore, a commercial power controller was adapted to provide stable temperature control. The construction of the heat shielding system provides a novel approach to reducing the beam's path length and the cell's size. The cell is inexpensive and easy to build. Its performance was evaluated by in situ XAS measurements of the temperature‐dependent structure of ceria nanocrystals. Some preliminary results for the structural mechanism in ceria nanocrystal redox applications are given.  相似文献   

16.
An automatic sample changer chamber for total reflection X‐ray fluorescence (TXRF) and X‐ray absorption near‐edge structure (XANES) analysis in TXRF geometry was successfully set up at the BAMline at BESSY II. TXRF and TXRF‐XANES are valuable tools for elemental determination and speciation, especially where sample amounts are limited (<1 mg) and concentrations are low (ng ml?1 to µg ml?1). TXRF requires a well defined geometry regarding the reflecting surface of a sample carrier and the synchrotron beam. The newly installed chamber allows for reliable sample positioning, remote sample changing and evacuation of the fluorescence beam path. The chamber was successfully used showing accurate determination of elemental amounts in the certified reference material NIST water 1640. Low limits of detection of less than 100 fg absolute (10 pg ml?1) for Ni were found. TXRF‐XANES on different Re species was applied. An unknown species of Re was found to be Re in the +7 oxidation state.  相似文献   

17.
A commercial fuel cell has been successfully modified to carry out X‐ray absorption spectroscopy (XAS) measurements under optimized in operando conditions. The design is conceived for the performance of XAS experiments in transmission mode over a wide range of X‐ray energies above 6 keV, owing to the reduced absorption of the cell. The wide angular aperture allows the collection of XAS in fluorescence mode and of X‐ray diffraction patterns when needed. Details of the design of the cell and its performances are given. The quality of the extended X‐ray absorption fine‐structure spectra under working conditions has been verified at the ESRF and ELETTRA synchrotron radiation facilities, showing that relatively fast and low‐noise transmission measurements on electrodes over a wide range of catalyst concentrations and energies are feasible.  相似文献   

18.
A new technique for the parallel collection of X‐ray reflectivity (XRR) data, compatible with monochromatic synchrotron radiation and flat substrates, is described and applied to the in situ observation of thin‐film growth. The method employs a polycapillary X‐ray optic to produce a converging fan of radiation, incident onto a sample surface, and an area detector to simultaneously collect the XRR signal over an angular range matching that of the incident fan. Factors determining the range and instrumental resolution of the technique in reciprocal space, in addition to the signal‐to‐background ratio, are described in detail. This particular implementation records ~5° in 2gθ and resolves Kiessig fringes from samples with layer thicknesses ranging from 3 to 76 nm. The value of this approach is illustrated by showing in situ XRR data obtained with 100 ms time resolution during the growth of epitaxial La0.7Sr0.3MnO3 on SrTiO3 by pulsed laser deposition at the Cornell High Energy Synchrotron Source (CHESS). Compared with prior methods for parallel XRR data collection, this is the first method that is both sample‐independent and compatible with the highly collimated, monochromatic radiation typical of third‐generation synchrotron sources. Further, this technique can be readily adapted for use with laboratory‐based sources.  相似文献   

19.
A high‐temperature furnace with an induction heater coil has been designed and constructed for in situ X‐ray spectroscopic experiments under controlled atmospheric conditions and temperatures up to 3275 K. The multi‐purpose chamber design allows working in backscattering and normal fluorescence mode for synchrotron X‐ray absorption and emission spectroscopy. The use of the furnace is demonstrated in a study of the in situ formation of Cr oxide between 1823 K and 2023 K at logPO2 values between ?10.0 and ?11.3 using X‐ray absorption near‐edge spectroscopy. The set‐up is of particular interest for studying liquid metals, alloys and other electrically conductive materials under extreme conditions.  相似文献   

20.
A high‐pressure cell for in situ X‐ray reflectivity measurements of liquid/solid interfaces at hydrostatic pressures up to 500 MPa (5 kbar), a pressure regime that is particularly important for the study of protein unfolding, is presented. The original set‐up of this hydrostatic high‐pressure cell is discussed and its unique properties are demonstrated by the investigation of pressure‐induced adsorption of the protein lysozyme onto hydrophobic silicon wafers. The presented results emphasize the enormous potential of X‐ray reflectivity studies under high hydrostatic pressure conditions for the in situ investigation of adsorption phenomena in biological systems.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号