首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The application of multiple known-addition or dilution techniques to the evaluation of potentiometric selectivity coefficients of ion-selective electrodes is proposed. The validity of the common form of the Nikolskii—Eisenman equation is assumed and experimental data are processed by using Gran-type linear functions. Six possible methods are derived which make it possible to work under bi-ionic conditions for the electrode response. Optimization of the experimental procedures is discussed.  相似文献   

2.
《Analytical letters》2012,45(7):1391-1396
Abstract

A simple formula is proposed for the definition and the calculation of the highest acceptable selectivity coefficient values of ion-selective electrodes. On the basis of the formula which is based on the consideration of the precision of the direct potentiometric measuring techniques one can easily decide whether the selectivity of an electrode is sufficient or not for solving a well defined analytical task correctly. On the other, hand it indicates clearly for ion-selective electrode developing teams or manufacturers how far the ion-selectivity of an electrode should be improved for a certain type of analytical application.

Characteristic selectivity values for a few concrete analytical sample types are given in table together with the selectivity coefficients of the corresponding, existing ion-selective electrodes.  相似文献   

3.
Deyhimi F 《Talanta》1999,50(5):1129-1134
In this work a new method is reported for the determination of potentiometric selectivity coefficients of ion-selective electrode in which, similar to real samples, several interfering ions are simultaneously present in test solutions and where the electrode shows its practical behavior. In order to illustrate this method, the potentiometric selectivity coefficients of a commercial liquid membrane ammonium selective electrode is determined for biologically important interfering ions: Li(+), Na(+) and K(+).  相似文献   

4.
The possible influence of the selectivity of the membrane used in an indicating electrode with potentiometric titrations was investigated by introducing some simple modifications in the calculations performed earlier. The influence of the selectivity is visible only before the equivalence point when the counter-ion is precipitated initially from the titrated solution. When the co-ion is precipitated initially, the shape of the titration curve is altered only after the equivalence point. The reliability of the determination of the equivalence point can be either advantageously or disadvantageously influenced by the selectivity, depending on the value of the selectivity coeffcient and the ratio of the diffusion coefficients.  相似文献   

5.
A new, simple, sensitive, low cost and rapid potentiometric method for direct determination of ultra trace amounts of sodium dodecyl sulfate (SDS) with a new DS(-)-selective electrode is reported. The electrode was prepared by electropolymerization of aniline in acidified DS- ion on the surface of a Pt electrode. The cyclic voltammetry (CV) was used for electropolymerization of polyaniline (PA) in the potential range of -200 to +1000 mV vs. Ag/AgCl. This sensor showed a Nernstian behavior (59.0 +/- 2.3 mV/decade) over a very wide linear range (1.0 x 10(-9)-3.0 x 10(-6) M) with a detection limit of 1.0 x 10(-9) M. The response time of the electrode was 15 s for 1.0 x 10(-7) M of analyte; the electrode can be used for 4 weeks without any major deviation. This electrode can be used in the pH range of 3.5-9.8. The selectivity of electrode to DS- over some organic, inorganic and anionic surfactants was investigated with the fixed primary ion method. The results show that the electrode is highly selective to DS- ion over other ions. The proposed electrode was applied to the determination of DS- in real samples.  相似文献   

6.
The potentiometric anion selectivity of two polymer membrane based electrodes (I and II) formulated with two new cyclopalladated amine complexes as the active components are examined. The electrodes exhibit a non-Hofmeister selectivity pattern with a significantly enhanced response towards thiocyanate, iodide and nitrite. The graph potential versus log c is linear over the concentration range 10(-6)-6x10(-2) M thiocyanate with electrode I and 10(-6)-10(-3) M with electrode II; 10(-5)-10(-2) M iodide with electrode I and 10(-3)-6x10(-2) M with electrode II; and 10(-3)-6x10(-2) M nitrite with both electrodes. The influence of the plasticizer and pH are studied. The potentiometric selectivity coefficients for I, II and blank membrane electrodes are reported. The selective interaction between Pd(II) thiocyanate, iodide and nitrite is postulated to be the reason for its higher response.  相似文献   

7.
Cu2+ selective PVC membrane electrode based on new Schiff base 2, 2'-[1,9 nonanediyl bis (nitriloethylidyne)]-bis-(1-naphthol) as a selective carrier was constructed. The electrode exhibited a linear potential response within the activity range of 1.0 x 10(-6) - 5.0 x 10(-3) moll(-1) with a Nernstian slope of 29 +/- 1 mV decade(-1) of Cu2+ activity and a limit of detection 8.0 x 10(-7) mol l(-1). The response time of the electrode was fast, 10 s, and stable potentials were obtained within the pH range of 3.5- 6.5. The potentiometric selectivity coefficients were evaluated using two solution method and revealed no important interferences except for Ag+ ion. The proposed electrode was applied as an indicator electrode to potentiometric titration of Cu2+ ions and determination of Cu2+ content in real samples such as black tea leaves and multivitamin capsule.  相似文献   

8.
The Neural Network (NN) technique was applied to the calibration of an ion selective electrode (ISE) array comprising a bromide selective electrode, two chloride ISEs and one thiocyanate ISE. The measured samples were synthetic mixture solutions of chlorides and bromides in concentration ranges such that interference occurs. The NN method allowed to perform the calibration without estimating the coefficients of the Nikolskii-Eisenman theoretical relation. Only the determination of bromide was detailed. The results obtained using this method were better than those obtained using linear multivariate calibration methods.  相似文献   

9.
主成分回归-络合滴定法测定混合金属离子   总被引:3,自引:0,他引:3  
提出了用络合滴定法测定混合金属离子.以汞膜电极为指示电极,银-氯化银电极为参比电极,以标准EDTA溶液滴定混合金属离子溶液.采集-系列指定电位点处滴定剂的体积,并以主成分回归法处理滴定数据.利用本文方法对铜、锌、铅、钻混合溶液进行了测定,结果满意.  相似文献   

10.
The potentiometric behavior of coated wire electrodes based on dodecylbenzenesulfonate-doped polypyrrole (PPy-DBS) and hyamine as ion exchanger was investigated. The PPy-DBS was prepared electrochemically by anodic polymerization of pyrrole in the presence of DBS ions in aqueous solution and used as ionophore for construction of the sensor. Two types of coated wire electrodes made of PVC-PPy-DBS and PVC-Hyamine-DBS, plasticized with ortho-nitrophenyloctylether (o-NPOE) showed the Nernstian behavior (with respective calibration slopes of about 58 and 60 mV per decade) over the DBS concentration range of 3.0×10−6 to 1.1×10−3 M and 5.0×10−6 to 1.3×10−3 M, respectively. The influence of membrane composition, type of plasticizer, and pH of test solution on the potentiometric responses of the two electrodes was investigated. The potentiometric response was independent of the pH of test solution in the range 3-10. The response time of electrodes was fast (10 s for both types of electrode), and they can be used for at least 3 months without any significant change in potential. The proposed electrodes revealed very good selectivity for DBS ion over diverse inorganic and organic anions. The potentiometric selectivity coefficients for the PPy-DBS based electrode revealed a significant improvement as compared to the electrode made by conventional Hyamine-DBS (Hya-DBS) anion exchanger. The proposed electrode was used for determination of DBS ion in some commercial detergents. The results of the potentiometric determinations were in satisfactory agreement with those obtained by a standard method (two-phase titration).  相似文献   

11.
It is a problem to be solved that the experimental selectivity coefficients of ion selective electrodes( ISEs) depend on the activity. This paper studied the new method of determining selectivity coefficients. A mixed ion response equation, which was similar to Nicolsky-Eisenman (N-E) equation recommended by IUPAC, was proposed. The equation includes the practical response slope of ISEs to the primary ion and the interfering ion. The selectivity coefficient was defined by the equation instead of the N-E equation. The experimental part of the method is similar to that based on the N-E equation. The values of selectivity coefficients obtained with this method do not depend on the activity whether the electrodes exhibit the Nernst response or non-Nernst response. The feasibility of the new method is illustrated experimentally.  相似文献   

12.
两点电位滴定法及其应用   总被引:16,自引:0,他引:16  
提出了只需两组数据即可计算电位滴定计量点的电位滴定数据处理新方法-两点法,并在此理论基础上,提出了两点电位测定法。该法只需记录两次电极电位值和相应滴定剂体积,利用公式即可计算滴定化学计量点。详细讨论了各因素对方法准确度的影响,给出了衡量滴定进行程度的客观指标,为两点位置的选择提供了充分的理论依据。实验结果表明:该法操作方便,数据处理简单,精密度与准确度均较高,分析速度较经典电位滴定法有较大提高。  相似文献   

13.
The potentiometric response of a metallic silver-wire electrode in the presence of silver ion complexing agents is theoretically derived on the basis of the Nernst equation. The cyanide response is shown to be in good agreement with the theory. The analytical utility of this inherently non-selective sensor is demonstrated by its application in gas-diffusion flow-injection analysis. By making use of a membrane barrier that prevents other than gaseous species from passing through, the almost specific determination of cyanide becomes feasible. Gaseous interferents (i.e., hydrogen sulphide, sulphur dioxide and nitrogen oxides) are chemically converted prior to entering the gas-diffusion unit. The apparent selectivity coefficients thus obtained are significantly better than those reported for common cyanide-selective electrodes.  相似文献   

14.
A triiodide-selective electrode based on copper (II)-Schiff base complex as a membrane carrier is proposed. The electrode was prepared by incorporating the carrier into a plasticized polyvinylchloride (PVC) membrane and was directly coated on the surface of a graphite electrode. The obtained electrode showed a near Nernstian slope of 57.0 ± 0.4 mV/decade to I 3 ions over an activity range of 1.0 × 10−5−1.0 × 10−1 M with a limit of detection of 4.8 × 10−6 M. The response time of the electrode was fast (5 s) and the electrode could be used for about 2 months without considerable divergence in response. The potentiometric selectivity coefficients were evaluated and displayed anti-Hofmeister behavior. The electrode was used as an indicator electrode in the potentiometric titration of the triiodide ion and in the determination of ascorbic acid in vitamin C tablets. The text was submitted by the authors in English.  相似文献   

15.
The potentiometric characteristics of a new Cu2+‐selective electrode based on 2‐(benzyliminomethyl)‐6‐methoxy‐4‐(4‐methoxyphenyl‐azo) phenol as an efficient ionophore has been evaluated. The effects of influential parameters on the potentiometric responses such as the amount of plasticizer, the amount of ionophore, pH of the sample solution, and the effect of coexisting ions on the electrode signal were subsequently investigated . The selectivity of the electrode was assessed by calculating the selectivity coefficients using the matched potential method. The optimum ratio of the amount of materials required for the preparation of the electrode was found to be 1.7: 32.1: 64.2: 2.0 corresponding to carboxylated PVC, dimethyl sebacate as solvent mediators, potassium tetrakis (p‐chlorophenyl) borate as the anion localizing agent, and ionophore, respectively. The electrode had a fast response (7s) as well as a satisfactory Nernstian slope (29.26±0.91 mV/decade) to Cu2+ over a wide concentration range of 2.0×10?6‐ 5.0×10?2 M with a low detection limit of 5.9×10?7 M. The developed sensor was successfully used for the potentiometric titration of Cu2+ ion with EDTA and subsequently, efficient determination of this metal ion in a mineral water sample was performed.  相似文献   

16.
A theory is presented that describes the matched potential method (MPM) for the determination of the potentiometric selectivity coefficients (KA,Bpot) of ion-selective electrodes for two ions with any charge. This MPM theory is based on electrical diffuse layers on both the membrane and the aqueous side of the interface, and is therefore independent of the Nicolsky-Eisenman equation. Instead, the Poisson equation is used and a Boltzmann distribution is assumed with respect to all charged species, including primary, interfering and background electrolyte ions located at the diffuse double layers. In this model, the MPM-selectivity coefficients of ions with equal charge (ZA = ZB) are expressed as the ratio of the concentrations of the primary and interfering ions in aqueous solutions at which the same amounts of the primary and interfering ions permselectively extracted into the membrane surface. For ions with unequal charge (ZA not equal to ZB), the selectivity coefficients are expressed as a function not only of the amounts of the primary and interfering ions permeated into the membrane surface, but also of the primary ion concentration in the initial reference solution and the delta EMF value. Using the measured complexation stability constants and single ion distribution coefficients for the relevant systems, the corresponding MPM selectivity coefficients can be calculated from the developed MPM theory. It was found that this MPM theory is capable of accurately and precisely predicting the MPM selectivity coefficients for a series of ion-selective electrodes (ISEs) with representative ionophore systems, which are generally in complete agreement with independently determined MPM selectivity values from the potentiometric measurements. These results also conclude that the assumption for the Boltzmann distribution was in fact valid in the theory. The recent critical papers on MPM have pointed out that because the MPM selectivity coefficients are highly concentration dependent, the determined selectivity should be used not as "coefficient", but as "factor". Contrary to such a criticism, it was shown theoretically and experimentally that the values of the MPM selectivity coefficient for ions with equal charge (ZA = ZB) never vary with the primary and interfering ion concentrations in the sample solutions even when non-Nernstian responses are observed. This paper is the first comprehensive demonstration of an electrostatics-based theory for the MPM and should be of great value theoretically and experimentally for the audience of the fundamental and applied ISE researchers.  相似文献   

17.
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on an N,N'-ethylene-bis(4-methyl-salicylidineiminato) nickel(II) [Ni(EBMSI)] complex as a carrier for a thiocyanate-selective electrode is reported. The influences of the membrane composition, pH and possible interfering anions were investigated based on the response properties of the electrode. The electrode exhibited a good Nernstian slope of -58.9 +/- 0.7 mV decade(-1), over a wide pH range of 3.5 - 8.5 and a linear range of 1.0 x 10(-6) - 1.0 x 10(-1) M for thiocyanate. The detection limit of electrode was 3.1 x 10(-7) M SCN(-). The selectivity coefficients determined by a fixed interference method (FIM) indicate that a good discriminating ability towards the SCN- ion compared to other anions. The proposed sensor had a fast response time of about 5 - 15 s and could be used for at least 3 months without any considerable divergence in the potential. It was applied as an indicator electrode in the titration of thiocyanate with Ag+ and in the potentiometric determination of thiocyanate in saliva and urine samples.  相似文献   

18.
A new heterogeneous precipitate of an organic-inorganic composite cation-exchanger poly-o-toluidine Zr(IV) phosphate was utilized for the preparation of a Hg(II) ion-sensitive membrane electrode for the determination of Hg(II) ions in real aqueous as well as in real samples. The electrode showed good potentiometric response characteristics, and displayed a linear log[Hg(2+)] versus EMF response over a wide concentration range of 1 x 10(-1) - 1 x 10(-6) M with a Nernstian slope of 30 mV per decade change in concentration with a detection limit of 1 x 10(-6). The membrane electrode showed a very fast response time of 5 s and could be operated well in the pH range 2 - 8. The selectivity coefficients were determined by the mixed-solution method, and revealed that the electrode was selective in the presence of interfering cations; however most of these did not show significant interference in the concentration range of 1 x 10(-1) - 1 x 10(-4) M. The lifetime of the membrane electrode was observed to be 120 days. The analytical utility of this electrode was established by employing it as an indicator electrode in the potentiometric titrations of Hg(2+) ions from a synthetic mixture as well as drain water.  相似文献   

19.
A nitrate-selective electrode based on a recently synthesized bis(2-hydroxyanil)acetylacetone lead(II) complex [(haacac)Pb] has been developed. Among different compositions studied, a membrane containing 30.7% poly(vinyl chloride) (PVC), 61.3% dibutyl phthalate (DBP) as a plasticizer, 3% methyltrioctylammonium chloride (MTOAC) as a cationic additive and 5% ionophore (all w/w) exhibited the best potentiometric response toward nitrate ion in aqueous solutions. The potentiometric response of the electrode was linear with a Nernstian slope of -58.8 mV decade(-1) within the NO3- concentration range of 2 x 10(-5)-1 x 10(-1) mol dm(-3). The response time of the electrode was < or =10 s over the entire linear concentration range of the calibration plot. The electrode is suitable for use within the pH range of 5.3-11. The selectivity coefficients for the proposed electrode were improved for some interferences, when compared with those of commercially available nitrate-selective electrodes.  相似文献   

20.
A novel membrane coated platinum-wire electrode (MCPWE) based on N,N'-bis(2-thienylmethylene)-1,2-diaminobenzene (BTMD) for highly selective determination of Ag+ ion has been developed. The influences of membrane composition and pH on the potentiometric responses of electrode were investigated. The potentiometric responses are independent of the pH of the test solution in the range of 5.0 - 9.0. The electrode shows a linear response for Ag+ ion over the concentration range of 1.0 x 10(-60 to 1.0 x 10(-1) M with a lower detection limit of 6.0 x 10(-7) M. The electrode possesses a Nernstian slope of 59.7 mV decade(-1) and a fast response time of < or = 17 s and can be used for at least 2 months without any observable deviation. The proposed electrode displayed very good selectivity for Ag+ ion with respect to NH4+ and alkali, alkaline earth and some common transition metal ions. The practical utility of the electrode has been demonstrated by its use as the indicator electrode in the potentiometric titration of an AgNO3 solution with a NaI solution and in determination of the silver content of a developed radiological film.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏