首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 36 毫秒
1.
Summary The extraction of the elements Ti, V, Cr, Mn, Fe, Co, Ni, Zn, Ga, As, Nb, Mo, Ru, Rh, Pd, Ag, Cd, In, Sn, Sb, La, W, Re, Os, Ir, Pt, Au, Hg, Tl, Pb and Bi from hydrochloric acid into methyl isobutyl ketone has been studied as a function of hydrochloric acid concentration. The results are presented in graphical form. The data were obtained by studying the distribution patterns of the elements after equilibration on a Craig countercurrent liquid-liquid extraction apparatus.
Zusammenfassung Die Extraktion der Elemente Ti, V, Cr, Mn, Fe, Co, Ni, Zn, Ga, As, Nb, Mo, Ru, Rh, Pd, Ag, Cd, In, Sn, Sb, La, W, Re, Os, Ir, Pt, Au, Hg, Tl, Pb und Bi mit Methylisobutylketon aus salzsaurer Lösung als Funktion der Säurekonzentration wurde studiert. Die Ergebnisse wurden aus den Spitzen der Verteilungskurven nach Einstellung des Gleichgewichts in einem diskontinuierlichen Gegenstrom-flüssig-flüssig-Extraktionsapparat berechnet.

Résumé On a étudié l'extraction des éléments Ti, V, Cr, Mn, Fe, Co, Ni, Zn, Ga, As, Nb, Mo, Ru, Rh, Pd, Ag, Cd, In, Sn, Sb, La, W, Re, Os, Ir, Pt, Au, Hg, Tl, Pb et Bi en solution chlorhydrique par la méthylisobutylcétone. On présente les résultats sous forme graphique. Les données ont été obtenues en étudiant les diagrammes de distribution des éléments après équilibrage sur un appareil Craig à extraction à contre-courant liquide-liquide.
  相似文献   

2.
Donaldson EM 《Talanta》1976,23(6):411-416
The chloroform extraction of 32 elements (Fe, Co, Ni, Zn, Cd, Ge, Sn, Pb, V, As, Sb, Bi, Cu, Ag, Au, Mn, Re, Ga, In, Tl, Ce, Se, Te, Cr, Mo, U, Pt, Pd, Rh, Ir, Ru and Os) from O.1-10M hydrochloric acid media in the presence of potassium ethyl xanthate has been studied. The oxidation states in which some elements react, and potential analytical separations, are discussed. Pd(II), As(III) and Se(IV) are completely extracted as ethyl xanthate complexes, Te(IV) is almost completely extracted, and Au(III) is largely extracted over the range of acid concentration investigated. Mn(II), Zn, Rh(III), Ir(IV), Ru(III), Os(IV), Cr(III), Cr(VI), Ce(III) and Ce(IV) are not extracted. Ge is partly extracted from 6-10M media as the chloro-complex. Depending on the acid concentration, the remaining elements are all partially extracted as xanthate complexes.  相似文献   

3.
We have developed a modified Carius Tube design that permits the low-blank digestion of geological samples prior to platinum-group element analysis. The new Carius Tubes incorporate a liner of high-purity quartz glass that retains the sample and acids during the digestion procedure. This dramatically reduces the comparatively high Pt blank associated with dissolutions in conventional Carius Tubes. Using the new Carius Tube design we are able to achieve total procedural blanks for the determination of the PGE in geological samples that are at the 1–15 pg/g level for Ru, Pd, Ir and Pt. This constitutes a reduction of blank values by a factor of ∼10–100 compared to standard NiS fire assay sample preparation techniques. Received: 23 September 1997 / Revised: 24 October 1997 / Accepted: 31 October 1997  相似文献   

4.
A method is proposed for determining platinum-group elements, Ru, Pd, Os, Ir, Pt, and Re in geological samples by isotope dilution with mass spectrometric ending after sample decomposition with a mixture (1: 3) of conc. HCl + HNO3 in a microwave system and the chromatographic separation of the analytes from the matrix on an AG 50W × 8 cation exchanger. The concentrations and isotope ratios are determined on high-resolution mass spectrometers ELEMENT and ELEMENT2. The attained detection limits range from 0.005 ng/g (Ir) to 0.2 ng/g (Pd) in solid samples. The use of isotope dilution improves the accuracy of determination and takes into account the matrix effect and changes in plasma parameters on the analytical signal. The method is tested in the analysis of standard samples of spinel lherzolite (GP-13) and serpentinite (UB-N). The relative standard deviation of the results of analysis is 5–22%, depending on the element and its concentration level (Ru, Pd, Re, Pt). In determining Os and Ir, a certain decrease in the accuracy and repeatability of the results is noticed.  相似文献   

5.
Donaldson EM  Mark E 《Talanta》1982,29(8):663-669
The chloroform extraction of 30 elements (Fe, Co, Ni, Zn, Cd, Ge, Sn, V, As, Sb, Bi, Cu, Ag, Au, Mn, Re, Ga, In, Tl, Se, Te, Cr, Mo, U, Pt, Pd, Rh, Ir, Ru and Ce) from 0.1-8M sulphuric acid in the presence of potassium ethyl xanthate has been studied. Pd(II), Bi, As(III), Sb(III), Se(IV) and Te(IV) are completely extracted and Au(III) is largely extracted over the range of acid concentration investigated. Fe(II), Tl(I), Rh(III) and Cr(VI) are only slightly extracted and Se(VI), Te(VI), Ru(III), Cr(III), Mn(II), Zn, Ce(IV), Ir(IV) and Ge(IV) are not extracted at all. Depending on the acid concentration, the remaining elements are all partly extracted. Results are compared with those obtained in an earlier study of the extraction of xanthate complexes from hydrochloric acid media. The processes involved in the formation of some xanthate complexes and potential analytical separations are discussed.  相似文献   

6.
We have developed a modified Carius Tube design that permits the low-blank digestion of geological samples prior to platinum-group element analysis. The new Carius Tubes incorporate a liner of high-purity quartz glass that retains the sample and acids during the digestion procedure. This dramatically reduces the comparatively high Pt blank associated with dissolutions in conventional Carius Tubes. Using the new Carius Tube design we are able to achieve total procedural blanks for the determination of the PGE in geological samples that are at the 1–15 pg/g level for Ru, Pd, Ir and Pt. This constitutes a reduction of blank values by a factor of ~10–100 compared to standard NiS fire assay sample preparation techniques.  相似文献   

7.
A method for the determination of low Ru, Pd, Re, Os, Ir and Pt abundances in geological reference materials by isotope dilution inductively coupled plasma mass spectrometry (ICP-MS) after acid digestion in a high pressure asher (HPA-S) is presented. The digestion technique is similar to that using Carius tubes but easier to handle and reaches higher temperatures. Osmium can be determined as OsO4 with ICP-MS directly after digestion through a sparging technique. The remaining elements are preconcentrated by means of anion column chromatography. The resin is digested directly without elution leading to high yields but this causes problems if Zr is present at higher levels in the silicate rich materials. The analytical results for international platinum group element (PGE) reference materials, chromitite CHR-Bkg, basalt TDB-1 and gabbro WGB-1, are presented and compared with literature data, demonstrating the validity of the described method. Although higher in concentration, PGEs determined for reference material WGB-1 were worse than for TDB-1 indicating a more inhomogeneous distribution of the platinum group mineral phases. The low PGE abundance chromitite standard, CHR-Bkg, is likely to be homogeneous for Ru, Re, Os and Ir and is recommended as a reference material for the study of chromitites. Detection limits (3s x total procedure blank) range from 0.012 ng (Re and Os) to 0.77 ng (Pt), which could be further improved by applying higher quality acids.  相似文献   

8.
Pohl P  Prusisz B  Zyrnicki W 《Talanta》2005,67(1):155-161
Metalfix Chelamine chelating resins of two different bead sizes (150-300 and 40-80 μm) were examined and compared regarding their application for sorption of Au, Ir, Pd, Pt, Rh and Ru ions from medium of HCl, HNO3 and mixtures of HCl and HNO3. The quantitative enrichment of Au, Ir, Pd and Pt was established for the resin of 150-300 μm particle size and for solutions acidified with HCl and HNO3 (3:1) up to the concentration of 0.50 mol l−1. In the case of Rh and Ru, the uptake of these metals by the resin was lower than 50%. For the elution, solutions of different reagents, i.e. HCl, HNO3, KCN, KI, KSCN and (NH2)2CS, were studied with respect to the complete release of the analytes retained by the resin. In addition, influence of various base metals, i.e. Al, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb and Zn, on the retention of the noble metals was investigated. Under the selected conditions for the retention and elution of Au, Ir, Pd and Pt, the analytical performance of the proposed pre-concentration procedure was evaluated and it was applied to the determination of these noble metals in anodic sludge sample.  相似文献   

9.
建立了两种以火试金预浓集为基础的、可用于准确测定铂族元素的方法;中子活化法和电感耦合等离子体质谱法。讨论了它们的分析检出限、准确度及其适应性。并用这两种方法测定了5种候选地质参考物质中铂族元素的含量。  相似文献   

10.
The sensitivities for the determination of 19 elements from Z = 44 to Z = 82, by means of 10-MeV proton activation, have been calculated from experimentally measured yields for 51 radioisotopes obtained mainly via (p,n) reactions. For an irradiation of 1 h at a beam current of 1 μA, the sensitivities established experimentally are about 0.02–2 p.p.m. for Ru, Pd, Ag, Cd, Sn, Sb, Te and I, 0.5–100 p.p.m. for In, W, Re, Ir, Pt, Au, Hg, Tl and Pb, and 15–900 p.p m- for Rh and Ba. Experimental results for the non-destructive analysis of these 19 elements in Al, Ag, Au, Co, Dy, Ho, Ir, Nb, Pr, Rh, Si, Ta and Tb, are presented.  相似文献   

11.
Modified silicagel (C18) was studied for separation and preconcentration of platinum group metals (Ru, Rh, Pd, Os, Ir and Pt) as ion associates of their chlorocomplexes with cation of onium salt N(1-carbaethoxypentadecyl)-trimethyl ammonium bromide. Sample containing HCl and the onium salt was pumped through the column. After elution with ethanol the eluate was evaporated in the presence of HCl. Resulting aqueous solutions were analysed with inductively coupled plasma atomic emission spectrometry (ICP-AES) and inductively coupled plasma mass spectrometry (ICP-MS). Recovery values of 1-20 mug Pt and Pd from 50 ml of synthetic pure solution were 100+/-3 and 100+/-1%, respectively, however, they diminished with increasing sample volume and in the presence of the real sample matrix or nitrate ions. Samples of engine soot (NIES No. 8), decomposed by low pressure oxygen high-frequency plasma, and airborne particulates from dust filters of meteorological stations, leached with HNO(3) and H(2)O(2), were analysed. A reasonable agreement was found between ICP-MS and ICP-AES results for airborne dust samples and the values comparable with those in literature were determined in NIES No. 8.  相似文献   

12.
The platinum-group elements (PGEs) are commonly determined by INAA and ICP-MS after a NiS fire assay preconcentration. The results of the initial round robin for the PGEs and gold were examined for geological Canadian reference materials (WGB-1, TDB-1, UMT-1, WPR-1, WMG-1, and WMS-1). The Au accuracy is generally within 15% for both methods. For Ir, Os, Pd, Pt and Rh the accuracy for most samples is better than 10% for FA-ICP-MS and FA-INAA (true only for sulfide-bearing samples in the case of FA-INAA). Ru is not very accurate by either methods. Ru and Au have problems with precision which is interpreted to be related to the loss of gold in the dissolution step and for Ru, the source of the problem is not yet understood. Kurtosis show that FA-INAA has higher clustering than FA-ICP-MS for most analytes. It suggests a slightly better precision for FA-INAA. This is explained by the robustness of INAA after the NiS preconcentration despite its lower instrumental precision versus the complex dissolution steps involved in ICP-MS. For samples richer in PGEs (sulfide- and/or oxide-bearing rocks) both methods perform adequately but for low PGEs concentration samples (crustal rocks) ICP-MS shows an advantage.  相似文献   

13.
A procedure for separation of Au, Ag, Pt, and Pd in geological samples has been developed. After irradiation, samples were fused with Na2O2 and silver was separated by filtering through a PbCl2 filter in 4M nitric acid solution. Au, Pt and Pd were concentrated with rhodium and thiourea as rhodium sulfide and the separation process of these elements was carried out by a chromatographic method. Au, Pt and Pd were retained on a Dowex-1×8 anion column in 1M HCl. Pd was eluted from the column by using a mixture of 75% HCl acid-25% acetone. Au was eluted by using a mixture of 10% HCl-90% acetone. In the gold fraction, Pt was also determined through the photopeak of199Au radionuclide (158 keV). The method was simple and rapid.  相似文献   

14.
The interferences from Cd, Cu, Hf, Pb, Sr, Zn, Zr and Y on the inductively coupled plasma quadrupole mass spectrometry (ICP-MS) determination of Pt, Pd, Rh, Ru and Ir in geological (Pt-ore SARM-7, abundance range for platinum metals 0.07-3.74 μg/g) and environmental samples (sediment JSd-2 abundance range for Pt and Pd 0.0167-0.021 μg/g; road dust and plant sample) are evaluated using model solutions, real samples and comparison to inductively coupled plasma atomic emission spectrometry (ICP-AES) results. Pt, Rh, Ru and Ir can be determined usually after introduction of corrections for the interference in all investigated materials though in sediments the direct determination of Pt might be a problem depending on the actual Hf concentrations. The direct determination of Pd (after microwave-assisted acid digestion) is possible in ores using all investigated isotopes (, , ), in plants using and correction for the interferences of Zr, Mo and Cd, and not possible in sediments and road dust. Therefore, we developed a procedure for isolation of Pd using its diethyl-dithio-carabamate (DDTC) complex. The detection limits for Pt, Pd and Ir are 0.015 ng/g, and for Ru and Rh 0.03 ng/g.  相似文献   

15.
Instrumental and radiochemical techniques have been developed for the analysis of samples of quartz-adularia veins from the epithermal gold-silver deposit Milogradovka. The optimal separation conditions of the Pt, Au, Ir, Re, Ag from non-noble metals have been determined in A400 MB in the Cl? form0.2 M HCl chromatographic system. The concentrations of the Pt, Au, Ir, Re and 36 other trace elements have been measured with combination of the instrumental and radiochemical neutron activation analysis techniques. The concentration range of the determined elements is from 2 × 10?2 to 7.5 × 103 mg kg?1. The study has been confirmed the presence of platinum mineralization of the epithermal deposit Milogradovka.  相似文献   

16.
A procedure is described for the determination of Y, Zr, Nb, Ru, Rh, Pd, Ag, Sb, Te, Hf, Ta, W, Re, Os, Ir, Pt, Au, Tl, Bi, and U in human urine and serum at concentrations relevant to the occupationally unexposed population. Sample preparation was limited to tenfold dilution with 2% HCl. A combination of a sample-introduction system designed to provide enhanced sensitivity and the use of water and acids of high-purity has resulted in limits of quantification (LOQ) in the sub-nanogram per liter range for 13 analytes. Instrumental background caused by release of analytes (Y, Zr, Ag, Sb, Au, Tl, Bi, U) from different parts of the sample-introduction system was found to be the major limitation in obtaining even better LOQ. Nevertheless, detection capabilities of the proposed procedure were adequate for all elements except Ru, Pd, and Rh. Despite of the use of high-resolution mode for these analytes some unresolved spectral interferences might still be present. For 13 elements an external accuracy assessment was accomplished by participation in proficiency testing and inter-comparison programs. Results obtained for pooled urine and serum were compared with concentrations reported for occupationally unexposed populations in recent publications.  相似文献   

17.
The extraction of Pt, Pd, Ir, Rh, Ru, Ag, Au, Co, Cu, Ni and Fe with n-octylaniline has been investigated. Noble metals are extracted 10(3)-10(4) times better than Cu, Ni, Co and Fe. A method of determination of Pt, Pd, Ir, Rh and Ru is proposed. They are first separated from Cu, Ni, Co and Fe by means of extraction (and then determined, in either the aqueous or organic phase, by atomic-absorption spectrophotometry. The atomic absorption of platinum metals (with the exception of Pd) is affected by other elements of the platinum group and by non-noble metals. La(NO(3))(3) and Nd(NO(3))(3) lower the limit of detection for Pt, Rh, Ir and Ru and inhibit the effect of Co, Cu, Ni, Fe, Bi, Zn, Na, etc. on their determination. Lanthanum and neodymium chlorides and sulphates produce a similar effect but only on the determination of Pt and Rh. The coefficient of variation of the determination, in both phases, is within 2-6.8%.  相似文献   

18.
Platinum (Pt), palladium (Pd), ruthenium (Ru), rhodium (Rh), iridium (Ir), and osmiun (Os) are platinum-group elements with similar physic-chemical properties, and have important applications in geochemistry and environmental chemistry. However, due to their low abundance and inhomogeneous distribution in natural ores as well as the nugget effect, the accurate determination of the platinum-group elements has been a challenge for geological analysis. In this work, self-prepared and purified sodium carbonate (NiCO3) instead of commercial nickel oxide (NiO) was used as the fire assay collector in order to greatly reduce the reagent blank and method detection limits. In addition, the fuming time of HClO4 was strictly controlled at 10?min and a high sensitive method was developed for the simultaneous determination of ultra-trace Pt, Pd, Ru, Rh, and Ir in minerals by inductively coupled plasma-mass spectrometry (ICP-MS) following preconcentration with the nickel sulfide fire assay. Under the optimized conditions, the linear ranges of Pt, Pd, Ru, Rh, and Ir were between 0 and 100?ng mL?1, with correlation coefficients exceeding 0.9997. The detection limits were 0.015, 0.056, 0.014, 0.004, 0.012?ng mL?1 (for 10?g sample) for Pt, Pd, Ru, Rh and Ir, respectively. The developed method was successfully applied to analyze Chinese Certified Reference Materials (CRMs) GBW07288, GBW07289, GBW07290, GBW07291, GBW07292, GBW07293, GBW07294, GBW07101, GBW07102 and GBW07201 and the determined values were in good agreement with the certified values. The relative standard deviations (n?=?5) of Pt, Pd, Ru, Rh and Ir were between 3.42% and 6.87% for the determination of GBW07291.  相似文献   

19.
The reversible sorption preconcentration of noble metals (NMs) using different schemes “sorbent–reagent–eluent” was investigated. The extraction of Au, Pd, Pt, Ir, Rh and Ru chlorocomplexes from hydrochloric acid solutions on hyper-crosslinked polysterene MN-200 in the form of ion associates with tributylamine (TBA) and 4-(n-octyl)diethylenetriamine (ODETA) was investigated. It was found that Pd, Pt and Au were quantitatively and reversibly extracted using TBA on hyper-crosslinked polysterene; the appropriate eluent for desorption was 1 M solution of HCl in ethanol. Ir, Rh and Ru under these conditions were not sorbed quantitatively. It was found that sorbent hydrophobicity is not the main characteristic that defines the efficiency of sorption of a particular NM ion associate. Different efficiencies of hyper-crosslinked polysterene MN-200 for sorption of square-planar chlorcomplexes of Pt, Pd and Au and octahedral complexes of Ir, Rh and Ru were found. For the first time, the sorbents with their own N-atoms – StrataX and StrataX-AW – were used for the sorption of Ir, Rh and Ru. Using these sorbents, the sorption of Ir was increased up to 95%, and the sorption of Ru and Rh was increased to about 40%. We can explain these results by nonspecific interaction of chlorcomplexes of Ir, Rh and Ru with ethylenediamine groups of the sorbent. Weak bases with large anions may be applied for desorption of Ir, Rh and Ru. Two schemes of dynamic sorption preconcentration of NMs from hydrochloric acid solutions were proposed – hyper-crosslinked polysterene MN-200 for the determination of Au, Pd, Pt, and StrataX-AW for Ir, Rh and Ru.  相似文献   

20.
Using HPGe detectors, the K X-rays and prompt gamma-rays below 200 keV from Ru, Rh, Pd, Ag, Re, Os, Ir, Pt and Au were measured under bombardment with protons from 1.8 to 5.4 MeV. Excitation functions for analytically important gamma-rays were determined. Interference-free sensitivities were calculated and the method was tested by the analysis of standard dental alloys.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号