首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A pressurized CEC (pCEC) coupled with on-column chemiluminescence (CL) detection was developed for direct determination of amino acids, which was based on the principle of an enhanced effect of Cu(II)-amino acid complexes on the CL reaction between luminol and hydrogen peroxide in alkaline solution. The effects of some important factors on pCEC separation and CL intensity were systemically investigated. Baseline separation of amino acids including L-histidine (L-His), L-threonine (L-Thr), and L-tyrosine (L-Tyr) was achieved by using a monolithic column with a mobile phase of 5.0x10(-3) mol/L phosphate buffer at pH 8.0 that contained 25% v/v methanol and 5.0x10(-4) mol/L luminol and 1.0x10(-5) mol/L Cu(II) at an applied voltage of -5 kV. The calibration curves of the analytes by plotting the peak height against corresponding concentration were linear over the range of 3.2x10(-6)-3.2x10(-4) mol/L for L-His, 4.1x10(-6)-4.1x10(-4) mol/L for L-Thr, and 6.0x10(-7)-3.0x10(-4) mol/L for L-Tyr. The LODs for L-His, L-Thr, and L-Tyr were 6.4x10(-7), 8.4x10(-7), and 3.0x10(-7) mol/L (S/N = 2), respectively. The proposed method was applied to the analysis of amino acid injection sample with satisfactory results. Mean recoveries for three amino acids were from 84.3 to 89.6%.  相似文献   

2.
Tris(2,2'-bipyridine) complex of iron(II) was found to cause an increase in the chemiluminescence (CL) emission of luminol dispersed in the reversed micellar medium of cetyltrimethylammonium chloride (CTAC) in 1:1 (v/v) dichloromethane-cyclohexane/water, when the iron(II) complex in dichloromethane was mixed directly with the reversed micellar solution containing luminol. Visible absorption measurements showed that, when dispersed in the CTAC reversed micellar medium, the iron(II) complex dissociates easily. In the reverse micelle, subsequently the free iron(II) ion produced may catalyze the CL oxidation of luminol even in the absence of hydrogen peroxide. The CL emission produced under the optimized experimental conditions was detectable at a minimum iron(II) concentration of 1.0 x 10(-9) M using a flow injection system.  相似文献   

3.
Zhou Y  Nagaoka T  Li F  Zhu G 《Talanta》1999,48(2):461-467
A novel chemiluminescence (CL) system was evaluated for the determination of hydrogen peroxide, glucose and ascorbic acid based on hydrogen peroxide, which has a catalytic-cooxidative effect on the oxidation of luminol by KIO(4). Hydrogen peroxide can be directly determined by luminol-KIO(4)-H(2)O(2) CL system. The detection limit was 3.0x10(-8) mol l(-1) and the calibration graph was linear over the range of 2.0x10(-7)-6.0x10(-4) mol l(-1). The relative standard deviation of H(2)O(2) was 1.1% for 2.0x10(-6) mol l(-1) (N=11). Glucose was indirectly determined through measuring the H(2)O(2) generated by the oxidation of glucose in the presence of glucose oxidase at pH 7.6. The present method provides a source for H(2)O(2), which, in turn, coupled with the luminol-KIO(4)-H(2)O(2) CL reaction system. The CL was linearly correlated with glucose concentration of 0.6-110 mug ml(-1). The relative standard deviation was 2.1% for 10 mug ml(-1) (N=11). Detection limit of glucose was 0.08 mug ml(-1). Ascorbic acid was also indirectly determined by the suppression of luminol-KIO(4)-H(2)O(2) CL system. The calibration curve was linear over the range of 1.0x10(-7)-1.0x10(-5) mol l(-1) of ascorbic acid. The relative standard deviation was 1.0% for 8.0x10(-7) mol l(-1) (N=11). Detection limit of ascorbic acid was 6.0x10(-8) mol l(-1). These proposed methods have been applied to determine glucose, ascorbic acid in tablets and injection.  相似文献   

4.
Chemiluminescence (CL) from the cobalt(II)‐catalyzed oxidation of luminol with hydrogen peroxide was dramatically enhanced by the presence of carbonate. The CL signal increases by several orders of magnitude over a wide range of concentrations of Co(II), luminol, or hydrogen peroxide. A limit of detection of 10?12 M for Co(II) and luminol and 10?8 M for hydrogen peroxide can be achieved. The CL emission spectrum exhibits a maximum at 425 nm, indicating that the excited 3‐aminophthalate is the emitting species. ESR spin‐trapping experiments revealed a large increase in the production of hydroxyl and carbonate radicals by the presence of carbonate, which is responsible for the enormous CL enhancement. Uric acid, ascorbic acid, acetaminophen, and p‐hydroxyphenyl acetic acid are capable of scavenging the radicals, thereby inhibiting the CL emission. The inhibition of CL intensity can be used to determine these substances at the sub‐micromolar level.  相似文献   

5.
This study established a novel flow injection (FI) methodology for the determination of phenol in aqueous samples based on luminol chemiluminescence (CL) detection. The method was based on the inhibition that phenol caused on the hemin-catalysed chemiluminescence reaction between luminol and hydrogen peroxide in alkaline solution. Optimum conditions and possible mechanisms have been investigated. The linear range was 2.0×10(-9) to 4.0×10(-7)gmL(-1) for phenol. The proposed method is sensitive with a detection limit of 4.0×10(-10)gmL(-1). The relative standard deviation for 11 measurements was 2.3% for 1.0×10(-7)gmL(-1) phenol. The method was applied for the determination of phenol in waste water samples. The results obtained compared well with those by an official method.  相似文献   

6.
Fassoula E  Economou A  Calokerinos A 《Talanta》2011,85(3):1412-1418
This work reports a sequential-injection analysis (SIA) method with chemiluminescence (CL) detection for the rapid assay of the total antioxidant capacity (TAC) in wines. The method exploited the Co(II)-catalysed CL reaction of luminol with hydrogen peroxide in alkaline medium. Zones of sample, hydrogen peroxide, catalyst (Co(II) solution) and alkaline luminol were sequentially aspirated into the holding coil of the SIA manifold. Then, the flow was reversed and the stacked zones were directed to the CL detector. As the zones overlapped, antioxidants in the samples scavenged a portion of hydrogen peroxide and the decrease in the CL intensity was monitored and related to the TAC. The chemical and geometric conditions were studied and the method was validated in terms of linearity, accuracy (trueness and precision), matrix effects, signal additivity and robustness. The reproducibility of the method (expressed as the between-days % relative standard deviation) was between 2.5 and 3.4% and the trueness (expressed as the % recovery in wines spiked with gallic acid) was in the range 96.7-97.3%. The sampling frequency was 60 samples h−1. The proposed SIA-CL method was compared with the DPPH method and the Folin-Ciocalteau (FC) method for the analysis of 25 wine samples.  相似文献   

7.
Lv Y  Zhang Z  Chen F 《The Analyst》2002,127(9):1176-1179
A chemiluminescence biosensor on a chip coupled to a microfluidic system and a microreactor is described in this paper. The chemiluminescence biosensor measured 25 x 75 x 6.5 mm in dimension, and was readily produced in an analytical laboratory. The sol-gel method is introduced to co-immobilize horseradish peroxidase (HRP) and luminol in the microreactor, and to immobilize uricase in the enzymatic reactor. The main characteristic of the biosensor was to introduce air as the carrier flow instead of the more common solution carrier for the first time. The uric acid was determined by a chemiluminescent (CL) reaction between the hydrogen peroxide produced from the enzymatic reactor and luminol under the catalysis of HRP in the microreactor. The linear range of the uric acid concentration was 1 to 100 mg L(-1) and the detection limit was 0.1 mg L(-1) (3sigma).  相似文献   

8.
A simple and sensitive chemiluminescence (CL) detection approach was developed for the direct analysis of aminoglycoside antibiotics in water samples following strong cation-exchange chromatographic (SCX-HPLC) separation. This detection system, which eliminates the need for sample derivatisation, is based on the inhibitory effect of aminoglycosides on the CL reaction between luminol and hydrogen peroxide catalysed by copper(II). As the operational and chemical variables that affect the CL signal were optimised, ionic strength and the Triton X-100 micelles turned out to be the keys to obtain maximum CL efficiency. Aminoglycosides were successfully separated in 10 min on a SCX column using a mobile phase consisting of an aqueous solution containing 5.0 x 10(-3)mol/l sodium acetate and 0.65 mol/l sodium chloride at pH 6.1. Sample volumes of 50 ml were preconcentrated by passage through a weakly acidic IRC-50 exchange column. Limits of detection from 0.7 to 10 microg/l and relative standard deviations from 2.7 to 5.4% were thus obtained. The proposed method surpasses other chromatographic alternatives in terms of the limit of detection, sample requirements for analysis and cost.  相似文献   

9.
Wang J  Chen G  Huang J 《The Analyst》2005,130(1):71-75
A glassy carbon electrode (GCE) modified with nickel(II) tetrasulfophthalocyanine (NiTSPc) and Nafion was used for the investigation of the catalytic oxidation of luminol. The modified electrode was found to much more effectively improve the emission of electrochemiluminescence(ECL) of luminol in a solution containing hydrogen peroxide. The enhanced ECL signal corresponded to the catalytic oxidation of both luminol and H(2)O(2) by NiTSPc. Attached Ni(II) on GCE was oxidised to Ni(III) and then used as the catalyst for the chemiluminescence of luminol. The enhanced stability of the ECL signal with Nafion would mainly result from the prevention of the dissolution of NiTSPc and the adsorption of the oxidation product of luminol on the electrode surface. The proposed method enables a detection limit for luminal of 6.0 x 10(-8) mol L(-1) to be achieved in the presence of H(2)O(2) in the neutral solution. The enhanced ECL intensity had a linear relationship with the concentration of luminol in the range of 1.0 x 10(-7)-8.0 x 10(-6) mol L(-1).  相似文献   

10.
《Analytical letters》2012,45(11):1837-1855
Abstract

A flow-injection procedure for the photochemical determination of glucose has been developed. The method is based on the photo-oxidation of glucose sensitized by 9,10-anthraquinone-2.6-disulfonate (disodium salt). The hydrogen peroxide formed in the photochemical reaction was measured by means of the chemiluminescent reaction with luminol and hematin. A linear calibration graph was obtained over the range 2.0x10?6-8.5 x 10?5 mol L?1. The method was applied to determining glucose in blood serum, urine and fruit juices.  相似文献   

11.
Li JJ  Du JX  Lu JR 《Talanta》2002,57(1):53-57
A selective flow injection electrogenerated chemiluminescence(CL) method for the determination of vanadium is described in this paper. It was based on the chemiluminescence reaction of luminol with vanadium(II), which was on-line electrogenerated from vanadate using a flow-through carbon electrolytic cell. Under the optimal conditions, the CL intensity was linear to the concentration of vanadium in the range of 5.0x10(-10)-1.0x10(-7) gml(-1) with a detection limit of 2x10(-10) gml(-1) vanadium. The relative standard deviation was 4% for 5.0x10(-8) gml(-1) vanadium in 11 repeated measurements. The method has been successfully applied to the determination of vanadium in environmental water samples.  相似文献   

12.
 A rapid flow-injection method with chemiluminescence (CL) detection is described for the determination of glutathione (GSH). The method is based on the CL reaction of luminol and hydrogen peroxide. GSH can greatly enhance the chemiluminescence intensity in 0.1 mol/L borax–sodium hydroxide buffer solution (pH = 9.7). The maximum CL intensity was directly proportional to the concentration of GSH in the range 3.0 × 10−7–2.0 × 10−5 mol/L, and the detection limit was 6.8 × 10−8 mol/L. The relative standard deviation was 3.4% for 5.0 × 10−6 mol/L of GSH (n = 11). Received October 23, 2001; accepted June 18, 2002  相似文献   

13.
The determination of vitamin K3 using the coupling between a photochemical reaction and a chemiluminescent reaction in a flow system is described. The method is based on the photooxidation of ethanol sensitized by vitamin K3 to yield hydrogen peroxide, which is monitored through the chemiluminescent reaction with luminol catalysed by hematin. The new approach allows the determination of vitamin K3 in a wide concentration range (1 x 10(-7)-5 x 10(-4) mol l-1) with a throughput of 30 samples h-1. The applicability of the method was demonstrated by the determination of vitamin K3 in pharmaceutical preparations.  相似文献   

14.
In this work the catalytic role of unsupported gold nanoparticles on the luminol–hydrazine reaction is investigated. Gold nanoparticles catalyze the reaction of hydrazine and dissolved oxygen to generate hydrogen peroxide and also catalyze the oxidation of luminol by the produced hydrogen peroxide. The result is an intense chemiluminescence (CL) due to the excited 3-aminophthalate anion. In the absence of gold nanoparticles no detectable CL was observed by the reaction of luminol and hydrazine unless an external oxidant is present in the system. The size effect of gold nanoparticles on the CL intensity was investigated. The most intensive CL signals were obtained with 15-nm gold nanoparticles. UV–vis spectra and transmission electron microscopy studies were used to investigate the CL mechanism. The luminol and hydroxide ion concentration, gold nanoparticles size and flow rate were optimized. The proposed method was successfully applied to the determination of hydrazine in boiler feed water samples. Between 0.1 and 30 μM of hydrazine could be determined with a detection limit of 30 nM.  相似文献   

15.
Three procedures are developed and investigated for the simple and fast determination of peroxide value of olive oil by luminol chemiluminescence. The procedure using hemin as catalyst in carbonate alkaline solution allows the determination of hydrogen peroxide within the range 0.014-50 μM. The method can be used for the determination of peroxide value within the range 2.00-30.0 mequiv. O2/kg oil and results correlate very well (r2 = 0.99) with those of the official method. All reagents are aqueous solutions and olive oil is dissolved in acetone:ethanol mixed solution and, hence, the method is using minimal amounts of organic solvents and can be successfully applied to field analysis. Antioxidant activity of five common compounds found in natural products was determined by using luminol CL with Co(II) as EDTA complex as catalyst at pH 9.00.  相似文献   

16.
Du J  Li Y  Lu J 《Talanta》2002,57(4):661-665
A new flow injection chemiluminescence (CL) method is proposed for the determination of thiamine, based upon its enhancing effect on the CL reaction of luminol with hydrogen peroxide in alkaline solution. The method allows the determination of thiamine within 0.05-8 mug ml(-1) range with a detection limit (3sigma) of 0.01 mug ml(-1). The relative standard deviation is 1.4% (n=11, 0.5 mug ml(-1) thiamine) and the sample throughput is about 90 samples h(-1). The method was successfully applied to the determination of thiamine in pharmaceutical preparations.  相似文献   

17.
Chemiluminescence (CL) was immediately observed after an iron-chlorophyllin aqueous solution was added to an acetonitrile/water mixed solution containing hydrogen peroxide. Quenching of the iron-chlorophyllin complex CL was caused by adding L-ascorbic acid. Based on these facts, a determination method involving small amounts of L-ascorbic acid was developed. As a result, this CL system is able to determine L-ascorbic acid over a wide concentration range of 4.0 x 10(-12) to 4.0 x 10(-4) mol L(-1). Also, coexisting substances, such as sugar and vitamins, did not interfere with the determination. Moreover, the participation to the CL was not observed when using other reducing agents, such as hydroxylamine hydrochloride. As an application for practical use, L-ascorbic acid in soft-drink powder was determined. The experimental value was almost the same as the calculated one (5.30 x 10(-5) mol L(-1)).  相似文献   

18.
A kinetic flow-injection (FI) method is described for the determination of hydrogen peroxide. This method is based on an iron(III)-catalyzed oxidative coupling of 4-aminoantipyrine with N,N-dimethylaniline by hydrogen peroxide. By measuring the change in the absorbance of the dye formed at 560 nm, 1 x 10(-6) - 6 x 10(-4) M hydrogen peroxide could be determined with a sampling rate of 15 h(-1). The relative standard deviation (n = 30) was 0.8% for 5 x 10(-5) M hydrogen peroxide. There was little interference of the co-existing ions and compounds. After introducing some immobilized enzyme reactors to the FI system, the proposed method allowed the determination of glucose and uric acid ranging from 1 x 10(-6) to 6 x 10(-4) M with relative standard deviations of below 2%. The applicability of the method was demonstrated by determining these substances in serum samples.  相似文献   

19.
A method based on pre-capillary derivatization with luminol (3-aminophthalhydrazide) for carbohydrate analysis using capillary electrophoresis with on-line chemiluminescence (CL) detection was developed. The derivatives of seven monosaccharides were separated and detected by using 200 mM borate buffer containing 100 mM hydrogen peroxide at pH 10.0 as separation electrolyte and 25 mM hexacyanoferrate in 3 M sodium hydroxide solution as post-capillary chemiluminescence reagent with separation efficiencies ranging from 160,000 to 231,000 plates per metre. The minimum amount of carbohydrate derivatized was 2 pmol (corresponding to the concentration of 2 microM). The method also provided a linear response for glucose in the concentration range of 0.1-250 microM with a mass detection limit of 420 amol or a concentration detection limit of 0.1 microM. Preliminary work using the CE-CL format to determine glucose in a rat brain microdialysis sample is presented as a typical case.  相似文献   

20.
Yeh HC  Lin WY 《Talanta》2003,59(5):1029-1038
The presence of carbonate or Tris causes a dramatic enhancement in the cheminluminescence (CL) for the oxidation of luminol with hydrogen peroxide catalyzed by microperoxidase 8 (MP8). A nearly constant enhancement in CL was observed over a wide range of H2O2 and luminol concentrations. The enhancement in CL is strongly pH-dependent, varying from 1.3 to 22.2 for carbonate and 1.6 to 10.2 for Tris. The CL enhancement is much more prominent at pH 9-10 than at high pH (>10.5) because of the extremely weak CL emission at pH below 10 when no enhancer is present. The CL enhancement is attributed to an accelerated CL cycle and the existence of alternative routes for luminol CL, possibly involving the carbonate, or Tris radicals. The dramatic enhancement in CL of the MP8-luminol-H2O2 system by the readily available reagents, sodium carbonate or Tris, will have general applications for sensitive CL assays. As an example, the presence of antioxidant results in a diminished and delayed CL emission, allowing the determination of its concentration at sub-micromolar level.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号