首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Facile strategies were developed for the versatile functionalization of platinum(IV) axial sites, allowing for easy accessibility to unsymmetric mono‐ and mixed‐carboxylato, as well as symmetric di‐substituted platinum(IV) complexes. The first method involves the direct oxidation and carboxylation of the platinum(II) center using an appropriate peroxide and the carboxylate of choice to firstly yield a monocarboxylato monohydroxido platinum(IV) complex. This platinum(IV) intermediate can undergo further carboxylation to give rise to a mixed‐carboxylato platinum(IV) complex. The second method involves the activation of the carboxylate of choice by a common carbodiimide coupling reagent, and its reaction with a dihydroxido platinum(IV) precursor to give the monocarboxylato platinum(IV) complex. Uronium salts can be employed to promote efficient dicarboxylation of the dihydroxido platinum(IV) precursor. Lastly, an axial azide pendant group was demonstrated to be suitable for orthogonal “click” conjugation reactions.  相似文献   

2.
A method ("electrosorption") has been developed for separation of silver from copper by its deposition through internal electrolysis with hydrogen adsorbed on a platinum surface. The silver can then be stripped and determined by atomic-absorption spectrometry or the dithizone method. The activation of the platinum surface with adsorbed hydrogen can be achieved either electrolytically or by passing hydrogen gas through the solution in which the platinum is immersed. The method of electrosorption has been successfully applied to determination of trace levels of silver in copper metal.  相似文献   

3.
Factor analysis was applied to the data matrix of in vitro growth inhibitory activities of 52 platinum complexes against 9 tumor cell lines, L1210, P388, Lewis lung, AH66, AH66F, HeLa S3, KB, HT-1197 and HT-1376 cell lines. Three factors were obtained by the principal factor analysis method. After the varimax rotation of these three factors, tumor cell lines were classified into four groups according to their factor loadings. The platinum complexes were characterized by the factor scores. Cisplatin was situated in an extreme position as compared with the other platinum complexes. In vivo antitumor activities of the platinum complexes were tested against L1210 and LL murine tumor models. The in vivo activity against L1210 showed a negative correlation with that against LL. Factor 2 scores of the complexes obtained by factor analysis of in vitro antitumor activities showed a good correlation with these in vivo antitumor activities. Then, the structure-factor 2 score relationships among platinum complexes were analyzed by the Free-Wilson method. From this analysis, structure-activity relationships for carrier ligands and leaving groups are proposed. Factor analysis is suggested to be a useful method to establish an efficient screening system for platinum complexes.  相似文献   

4.
《Analytical letters》2012,45(8):1505-1518
Abstract

A simple and rapid differential pulse polarographic assay for measurement of platinum drug binding to DNA is described. The method makes it possible to determine the free (unbound) platinum compound in the presence of DNA or platinum - DNA complex. The method is based on the polarographic catalytic hydrogen current yielded by platinum (II) or (IV) complexes in formaldehyde - hydrazine - sulphuric acid background electrolyte, in which DNA or platinum - DNA complex precipitate. The lower level of analytical utility of this method is c. 1 × 10?9 M.  相似文献   

5.
Automobile catalytic converters emit nanocrystalline platinum attached to alumina particles. For investigations about the bioavailability of Pt from these particles a model substance with approx. 5% Pt on alumina has been prepared and characterized by physical methods (ESCA, XRD, TEM, DTA, TG). Measuring the platinum solubility of these samples in different solvents revealed high amounts that can be explained assuming a corrosion process. The portion of soluble platinum is dependent on the particle size distribution. For a comparative study platinum black has been used. In general the platinum determination has been carried out by electrothermal atomic absorption spectrometry (ET-AAS). The comparison of ET-AAS results with determinations by adsorptive voltammetry (formazone method) allowed to distinguish between elemental and ionic platinum; in solution samples only ionic platinum has been present. UV spectra of extracts have been used for the semi-quantitative platinum speciation in solutions.  相似文献   

6.
Automobile catalytic converters emit nanocrystalline platinum attached to alumina particles. For investigations about the bioavailability of Pt from these particles a model substance with approx. 5% Pt on alumina has been prepared and characterized by physical methods (ESCA, XRD, TEM, DTA, TG). Measuring the platinum solubility of these samples in different solvents revealed high amounts that can be explained assuming a corrosion process. The portion of soluble platinum is dependent on the particle size distribution. For a comparative study platinum black has been used. In general the platinum determination has been carried out by electrothermal atomic absorption spectrometry (ET-AAS). The comparison of ET-AAS results with determinations by adsorptive voltammetry (formazone method) allowed to distinguish between elemental and ionic platinum; in solution samples only ionic platinum has been present. UV spectra of extracts have been used for the semi-quantitative platinum speciation in solutions.  相似文献   

7.
张小玲  阎宏涛 《中国化学》2002,20(10):1055-1059
A selective and sensitive method for determination of platinum and palladium(Ⅱ)in an aqueous solution simultaneously by laser thermal lens spectrometry,based on the complex reaction of 2-(3,5-dichloropyridylazo)-5-dimethylaminoamiline(3,5-diCl-PADMA) with platinum and palladium,has been developed.It is shown that the palladium complex can be fromed at room temperature, while the platinum complex can be only formed after being heated in a boiling water bath.By using this difference of reaction temperature and the characteristic of the complexes mentioned above,the method for simultaneous determination of platinum and palladium was established in an aqueous solution without a pre-separation.The results show that the dynamic linear ranges of determination for platinum and palladium are 0.005-0.04μg/mL and 0.005-0.25μg/mL respectively,and that the detection limits are both 0.002/μg/mL.The method has been applied to the determination of platinum and palladium simultaneously in alloy and catalyst samples with satisfactory results.  相似文献   

8.
原媛  巩岩  尹笑 《分析试验室》2021,(3):260-264
通过水相合成法制备了硫鸟嘌呤(TG)修饰的锰掺杂硫化锌量子点(TG-Mn:ZnS QDs)。加入Pt4+后,Pt4+会与硫鸟嘌呤上的氮原子结合形成N-Pt4+配位结构附着在TG-Mn:ZnS QDs的表面,随着Pt4+浓度的增加,TG-Mn:ZnS QDs-Pt4+体系发生电子转移而导致磷光逐渐被猝灭,基于此构建了检测Pt4+的磷光探针。实验中考察了p H、时间对Pt4+猝灭TG-Mn:ZnS QDs磷光强度的影响。在最佳实验条件下,Pt4+浓度在0.06~2.4μg/mL范围内与TG-Mn:ZnS QDs的磷光强度呈良好的线性关系y=0.0884x+0.2319,R2=0.991,方法检出限(3σ/n)为1.3μg/mL。该磷光探针适用于实际样品中Pt4+含量的测定。  相似文献   

9.
We present a highly sensitive, rapid method for the determination of platinum originating from the anticancer agents cisplatin, carboplatin, and oxaliplatin in human plasma ultrafiltrate. The method is based on the quantification of platinum by inductively coupled plasma mass spectrometry and allows quantification of 7.50 ng l-1 platinum in only 150 microl of matrix. Sample pretreatment involves dilution of samples with 1% HNO3. Validation fulfilled the most recent FDA guidelines for bioanalytical method validation. Validated ranges of quantification were 7.50 ng l-1 to 1.00x10(5) ng l-1 in plasma ultrafiltrate for all three platinum compounds. The assay is now successfully used to support pharmacokinetic studies in cancer patients treated with cisplatin, carboplatin, or oxaliplatin.  相似文献   

10.
S B Adeloju  A M Bond  S N Tan  G Wei 《The Analyst》1990,115(12):1569-1576
The extremely sensitive catalytic hydrogen ion reduction wave observed after the formation of a platinum-formazone complex at a mercury electrode in a hydrazine-formaldehyde-H2SO4 medium has been utilised to determine platinum voltammetrically in well characterised platinum inorganic complexes (oxidation states O, II and IV) and in biological, geological and water samples. Experimental conditions have been optimised and sample-treatment procedures for various matrices have been critically evaluated for the quantification of platinum by the standard additions method. The determination of platinum in geological samples by this method has been compared with an inductively coupled plasma mass spectrometric method. Both conventional and portable field-based instrumentation have been used in the studies, and the possibility of developing a field-based method for the determination of platinum has been investigated. Despite the inherent sensitivity of the method, which enables concentrations down to 0.01 p.p.b. to be detected in simple matrices, natural levels in water and biological materials, where matrix effects suppress the voltammetric response, are often below the detection limit.  相似文献   

11.
微波-气相-热压法分解高纯铂的研究   总被引:1,自引:0,他引:1  
本文研究了微波气相热压法新技术分解高纯铂在密闭的聚四氟乙烯高压罐中,以微波瞬间加热混合酸产生的高压、纯净蒸气分解金属铂,此法避免了酸中杂质的沾污以制备供高纯铂分析的试液,提高了痕量杂质分析的准确度和降低检测限  相似文献   

12.
以天然鳞状石墨为原料,采用化学氧化法合成氧化石墨,在此基础上采用低温热解膨胀结合微波加热乙二醇还原法合成石墨烯(Gr)以及铂/石墨烯(Pt/Gr)复合材料。SEM和TEM显示所制备的石墨烯为层状结构的半透明薄膜。采用X射线光电子能谱(XPS)和傅立叶转换红外光谱(FTIR)分别确定氧化石墨、膨胀石墨及石墨烯表面含氧官能团的数量和性质。以所制备的碳氧原子比5.94的石墨烯作为载体制备出可用于质子交换膜燃料电池的高负载量的Pt/Gr催化剂,在铂载量高达60%时,表面铂粒子依然具有高分散性,平均粒径为3.8 nm。  相似文献   

13.
A sensitive analytical method based on flameless atomic absorption spectrometry with Zeeman correction has been validated for the quantitative determination in human plasma of platinum originating from cisplatin in a liposomal source, SPI-77. The performance of the method was acceptable over a sample concentration range of 0. 125-1.25 micromol platinum/L and the lower limit of quantification was determined to be 1.25 micromol platinum/L in undiluted clinical samples. The performance data of the assay were investigated using both a calibration curve with carboplatin in plasma ultrafiltrate and diluted human plasma samples spiked with SPI-77. The recoveries, between-day and the within-day precisions of both methods of calibration were not significantly different allowing carboplatin ultrafiltrate calibration standards to be used to quantify platinum derived from SPI-77 in human plasma. Apparently, the liposomal formulation had no significant influence on the determination of platinum. The usefulness of the presented method was demonstrated in a phase I clinical and pharmacokinetic study. In addition, in vitro experiments were carried out to determine the distribution of SPI-77 in blood. The results indicated that platinum from SPI-77 mainly concentrates in plasma and that binding to and/or endocytosis in red blood cells is negligible.  相似文献   

14.
Summary Investigations on the spectrophotometric determination of platinum as a complex formed by tin(II)chloride in hydrochloric acid are reported. The determination of platinum was found to be interfered with by iridium, because it also forms a complex with tin(II) chloride. The features of the derivative absorption spectrophotometry for the quantitative determination of platinum and iridium was also studied. The analytical application of the method for the determination of platinum and iridium in catalysts was investigated.  相似文献   

15.
Kundu D  Roy SK 《Talanta》1992,39(4):415-418
A spectrophotometric method has been developed for determination of trace amounts of platinum in glass. The method is based on the extraction of platinum(II) from 1M hydrochloric acid containing 0.2M stannous chloride and 4 x 10(-4)M dithizone onto polyurethane foam, elution with acetone (containing 3% v/v concentrated hydrochloric acid) and measurement of the absorbance of the eluate at 530 nm. Beer's law is obeyed up to 10.0 microg/ml Pt. The minimum platinum level in the eluate that can be determined by this method is 0.1 microg/ml.  相似文献   

16.
The `size effect' of ultrafine platinum particles supported on a carbon material for the electrocatalytic oxidation of methanol has been examined by a model catalyst method. Chronoamperometry revealed that the specific activity of the reaction per real surface area of the platinum particles decreases with a decrease in the platinum particle size.  相似文献   

17.
Trialkylphosphine oxides extract more effectively chloride complexes of platinum than of palladium(II). Of the examined tributylphosphine (TBPO), trioctylphosphine (TOPO), and triphenylphosphine (TPPO) oxides the latter one makes possible best separation of these metals.The extraction of platinum with TPPO from solutions containing platinum and palladium unfavorably decreases with increasing palladium concentration. Using 0.1 M TPPO solution in dichloroethane, at HCl concentration 7.5 M, it is possible to separate 2–200 μg Pt/ml at a palladium concentration not higher than 10 mg/ml.Separation of platinum from macroamounts of palladium has been combined with spectrophotometric determination of platinum by means of stannous chloride. The method has been applied to the analysis of palladium for platinum content.  相似文献   

18.
An x-ray fluorescence (x.r.f.) method is described for the determination of platinum contents (0.3–0.6%) in some special types of platinum catalysts. Calibration graphs were linear in the range 30–700 μg g?1 platinum with a 3σ detection limit of 10 μg g?1 for a 2000-s counting time. Because of the lack of certified standard platinum catalysts for checking accuracy, the results obtained were compared with results from visible spectrophotometry (tin (II) chloride method), optical emission spectrometry and atomic absorption spectrometry. Statistical evaluation showed no significant errors at the 95% confidence interval.  相似文献   

19.
韩帅兵  段艳林  李菲菲 《化学学报》2007,65(23):2750-2754
利用自制的凹形电极在铂基底电极上直接构建了葡萄糖氧化酶微米点. 首先, 将电聚合和电化学刻蚀法相结合制备了凹形铂微米电极. 然后将此种电极作为参比及辅助电极, 基底铂电极作为工作电极, 利用葡萄糖氧化酶在合适的条件下(浓度、一定量Triton X-100存在、电极电位等)由于电极表面pH的降低可以在铂电极上电沉积这一特性, 将酶固定在铂基底电极上, 微修饰得到了具有活性的葡萄糖氧化酶微米点. 最终用扫描电子显微镜和扫描电化学显微镜对所得微米点进行了表征. 所得微米点直径约20 μm, 且具有催化活性. 该方法简便, 干扰因素较少.  相似文献   

20.
The platinum group elements (PGEs), particularly platinum, palladium and rhodium, are nowadays increasingly emitted into the environment from automotive catalytic converters. Thus, a method for the determination of PGEs (especially platinum and rhodium) in dust and plant samples was developed. The developed method was based on microwave-assisted sample digestion and inductively coupled plasma mass spectrometric (ICP-MS) determination. Spectral interferences in ICP-MS determination were corrected using mathematical correction equations based on signal ratio measurement. In addition, platinum and rhodium concentrations in the digested dust samples were also determined after Te coprecipitation without correction of the interferences. The results for platinum and rhodium in reference materials (NIST SRM 2557, recycled monolith autocatalyst and BCR-723, road dust) were in good agreement with the certified values. Preliminary results for the anthropogenic platinum and rhodium emissions in Oulu, northern Finland, based on dust and plant samples, indicated a common traffic-related source of these metals.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号