首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Novel and Convenient Approach to Synthesis of AZT/d4T H-phosphonates   总被引:1,自引:0,他引:1  
A convenient, efficient and general method has been developed for synthesis of H-phosphonate mono and diesters of AZT and d4T through one-pot reaction of phosphonic acid with AZT or d4T and different alcohols using pivaloyl chloride as condensing agent under mild conditions.  相似文献   

3.
Intensive efforts have been made to develop effectively chemotherapeutic agents against the human immunodeficiencv virus (HIV). [1] Nucleoside analogues are widelv used as antiviral agents in the treatments of AIDS and the AIDS related complex.[2]  相似文献   

4.
In this paper, we synthesized a novel nucleoside analog by coupling thymine with dimethyl dicarboxylate biphenyl (DDB). The structure of the target compound was determined using 1H nuclear magnetic resonance (NMR) and electrospray ionization tandem mass spectrometry (ESI-MS/MS). The fragmentation pathways were studied in details through ESI-MS/MS. By comparing with unsubstituted nucleosides, such as AZT, MCI, d4T and DDI, it was found that the nucleoside analog coupled with DDB would not yield the daughter ions corresponding to the fragments of the nucleoside base and arabinofuranose analogs, but would lose a neutral molecule HF and DDB easily. However, the unsubstituted nucleosides could lightly yield the fragment ions of the nucleoside base and sugar ring. Hence, electrospray ionization mass spectrometry combined with tandem mass spectrometry (MS/MS) provides a convenient method to recognize the substituted and unsubstituted nucleosides.  相似文献   

5.
We propose a new algorithm for deconvolution of electrospray ionization mass spectra based on direct assignment of charge to the measured signal at each mass-to-charge ratio (m/z). We investigate two heuristics for charge assignment: the entropy-based heuristic is adapted from a deconvolution algorithm by Reinhold and Reinhold;10 the multiplicative-correlation heuristic is adapted from the multiplicative-correlation deconvolution algorithm of Hagen and Monnig.6 The entropy-based heuristic is insensitive to overestimates of z(max), the maximum ion charge. We test the deconvolution algorithm on two single-component samples: the measured spectrum of human beta-endorphin has two prominent and one very weak line whereas myoglobin has a well-developed quasi-gaussian envelope of 17 peaks. In both cases, the deconvolution algorithm gives a clean deconvoluted spectrum with one dominant peak and very few artefacts. The relative heights of the peaks due to the parent molecules in the deconvoluted spectrum of a mixture of two peptides, which are expected to ionize with equal efficiency, give an accurate measure of their relative concentration in the sample.  相似文献   

6.
Tuning compounds for positive and negative electrospray ionization (ESI) were tested for the tuning of in-source collision-induced dissociation (ESI/CID) with three types of SCIEX API instruments (API 365, 2000 and 3000) in the single-quadrupole mode. The vacuum interfaces of these instruments differ slightly in geometry, but the principles of ionization and solvent evaporation by nebulizer and curtain gases, orifice and skimmer are identical. For comparison of in-source CID, breakdown curves of haloperidol, paracetamol, metronidazole and metamizole were acquired by increasing the orifice voltages. The API 2000 and 3000 required higher orifice voltages than did the API 365 to induce a similar degree of fragmentation of the protonated or deprotonated molecules to characteristic fragment ions. This increase of orifice voltage could be demonstrated with each of the four compounds tested by a shift of the maxima of the breakdown curves to higher orifice voltages. A procedure with three collision energy (CE) levels for drug identification with a mass spectra library set up with an API 365 therefore required an adjustment of the orifice voltages to higher values when being transferred to an API 2000 or API 3000. The corresponding orifice voltages for the three instruments were 20/50/80 V (API 365), 30/90/130 V (API 2000) and 40/80/120 V (API 3000). However, a change in orifice voltage of +/-10 V (with the API 2000 and 3000) hardly influenced the fit values of a library search for each single CE level. For adjusting orifice voltages with different instruments, a tuning procedure with haloperidol and paracetamol is presented. With this tuning procedure an ESI/CID mass spectra library set up for API 365 and API 150 could also be used for drug identification with an API 2000 and an API 3000 with good library search results.  相似文献   

7.
Process improvements in the synthesis of therapeutic agents and their intermediates are often facilitated by identification of reaction by-products. Analysis by liquid chromatography/mass spectrometry (LC/MS) with electrospray ionization is a powerful approach for obtaining molecular weight information for these compounds. Such analyses are well suited for 'open-access' mass spectrometry using generic chromatographic conditions, provided spectral interpretation for unknown compounds is facile. We have developed a software application (MassAssign) that facilitates automated data processing and molecular weight assignment for chromatographic peaks detected by any standard ultraviolet-visible wavelength detector. The program assigns [M + H](+) ions (and thus molecular weight) in the mass spectra using predetermined criteria. This evaluation process differentiates [M + H](+) ions from other signals in a complex mass spectrum such as those resulting from chromatographic coelution or the presence of multiple species (i.e., fragment ions, singly charged ions, doubly charged ions, adduct ions, proton-bound dimers, etc.). Once the program has evaluated all ions in a mass spectrum that exceed a preset abundance threshold, MassAssign reports either a numeric value-indicating the chromatographic peak consists of a single component having the displayed molecular weight, 'MC'-indicating the peak consisted of multiple components, or 'ND'-that a molecular weight could not be determined unequivocally. The performance of the program was evaluated by comparing mass assignments made by MassAssign against manual interpretation for 55 samples analyzed by positive electrospray ionization using a generic HPLC method. Correct molecular weight assignments were obtained in 90% of the cases.  相似文献   

8.
Electron ionization (EI) and positive electrospray ionization (ESI) mass spectra of selected diaryl enaminoketones and enaminothiones have been studied. In the EI mass spectra of both classes of compound, molecular ion peaks are accompanied by the peaks corresponding to the [M-H](+) ions. The formation of these ions can be rationalized by a cyclization reaction resulting in the formation of the respective isoxazolium and isothiazolium cations. Under positive ESI conditions, in the spectra recorded for the enaminoketones peaks corresponding to the [M+H](+), [M+Na](+) and [2M+Na](+) ions appeared, while in the spectra recorded for the enaminothiones, peaks corresponding to the [M-H](+) ions were dominant. These ions are most likely formed by oxidation of the neutral enaminothione molecules on the surface of the positively charged stainless steel capillary in the ESI ion source (anodic oxidation).  相似文献   

9.
Cluster ions such as [Cat+X+nM](+) (n = 0-4); [Cat-H+nM](+) (n = 1-3); and [2(Cat-H)+X+nM](+) (n = 0-2), where Cat, X, and M are the dication, anion, and neutral salt (CatX(2)), respectively, are observed in electrospray ionization (ESI) mass spectrometry of relatively concentrated solutions of diquat and paraquat. Collision-induced dissociation (CID) reactions of the clusters were observed by tandem mass spectrometry (MS/MS), including deprotonation to form [Cat-H](+), one-electron reduction of the dication to form Cat(+.), demethylation of the paraquat cation to form [Cat-CH(3)](+), and loss of neutral salt to produce smaller clusters. The difference in acidity and reduction power between diquat and paraquat, evaluated by thermodynamical estimates, can rationalize the different fractional yields of even-electron ([Cat-H](+) and its clusters) and odd-electron (mostly Cat(+)) ions in ESI mass spectra of these pesticides. The [Cat+n. Solv](2+) doubly charged cluster ions, where n 相似文献   

10.
The effect of electrospray ionization (ESI) conditions on low-energy tandem mass spectra of peptides in the relative molecular mass range 400–1200 was examined. For singly charged peptide ions the source skimmer potential (which determines the degree of acceleration of the ions through the intermediate pressure region in the source) can strongly influence the extent of fragmentation observed in tandem mass spectra, especially at low collision energies. For each peptide there is an optimum skimmer potential which represents a balance between generating ions with sufficient internal energy for subsequent tandem mass spectrometric experiments and inducing the onset of other processes such as source fragmentation. The fragmentation which can be achieved in tandem mass spectra with high skimmer potentials differs from ESI source fragmentation for the same peptides. We have found that fragmentation in ESI mass spectra depends both on skimmer potential and on solvent pH, presumably because the latter determines the proportion of doubly charged species generated from a given peptide. Low-energy tandem mass spectra of peptides following ESI are equally as sensitive to peptide structure and the type of adduct studied (e.g. [M + H]+ vs. [M + NH4]+) as tandem mass spectra obtained following older ionization methods such as fast atom bombardment.  相似文献   

11.
It is demonstrated that tetrahydrofuran (THF) should be used with caution as a solvent in polymer sample preparation for matrix-assisted laser desorption/ionization (MALDI) analyses. The presence of peroxides in THF may cause the oxidation of chemically active groups. This effect is illustrated in the case of S-containing polystyrene derivatives. The oxidation of the trithiocarbonate group resulted in the formation of poly(styrene)sulfonic acids, R(CH(2)CHPh)(n)SO(3)H, which was detected in negative mode by MALDI and electrospray ionization (ESI) methods after the samples remained in THF for several hours.  相似文献   

12.
13.
A simple and one-pot route for the synthesis of d4T or AZT hydrogen phosphonate derivatives via reaction of d4T or AZT with phosphorus trichloride, then alcoholysis and dealkylation in the presence of the corresponding alcohol is described.  相似文献   

14.
Several amino acid ester cyclohexyl phosphoramidates of AZT as anti-HIV prodrugs were synthesized and investigated by electrospray ionization tandem mass spectrometry (ESI-MS(n)). A novel methoxy group migration from the carbonyl group to the phosphoryl group was observed in ESI-MS2. This migration is believed to be a general pathway for ions with a methyl ester moiety at the gamma-position to a phosphoric acid moiety, which is assisted with metal ions such as Li(+), Na(+) and K(+). Coordination between metal ions with both the carbonyl oxygen and phosphoryl oxygen might be a key factor responsible for this migration.  相似文献   

15.
The S-nitrosylation of proteins is involved in the trafficking of nitric oxide (NO) in intra- and extracellular milieus. To establish a mass spectrometric method for identifying this post-translational modification of proteins, a synthetic peptide and transthyretin were S-nitrosylated in vitro and analyzed by electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. The intact molecular ion species of nitrosylated compounds was identified in the ESI mass spectrum without elimination of the NO group. However, the labile nature of the S-NO bond was evident when the in-source fragmentation efficiently generated [M + H - 30](+) ions. The decomposition was prominent for multiply charged transthyretin ions with high charge states under ordinary ESI conditions, indicating that the application of minimum nozzle potentials was essential for delineating the stoichiometry of nitrosylation in proteins. With MALDI, the S-NO bond cleavage occurred during the ionization process, and the subsequent reduction generated [M + H - 29](+) ions.  相似文献   

16.
The 3'-iodonucleosides 4 have been synthesized by condensation of silylated 5-alkyluracils 2 with methyl 5-O-tert-butyldiphenylsilyl-2,3-dideoxy-3-iodo-D-threo-pentofur anoside (3). 4 was treated with sodium azide and the deprotected nucleoside 5 was subsequently obtained by treatment with tetrabutylammonium fluoride. The nucleoside 4 produced the corresponding 2',3'-didehydro-2',3'-dideoxy nucleoside 6 and 3',4'-didehydro-2',3'-dideoxy nucleoside 7 in elimination reactions on treatment with sodium methoxide.  相似文献   

17.
This work describes the synchronized dual-polarity (DP) electrospray ionization (ESI) method and demonstrates the first DP ESI mass spectra obtained using two mass spectrometers. Stable double Taylor cones were produced by applying two counter electric voltages with opposite polarities to one electrosprayer. The development of double Taylor cones required higher extraction voltages than conventional ESI, but DP ESI worked effectively at liquid flow rate range three times wider than conventional ESI. Using pure methanol, the emission currents of the two cones were neutralized and no current was drawn from the sprayer. Synchronized DP mass spectra were obtained using electrospray calibrants dissolved in methanol solution of low water content. For bovine insulin with conventional electrospray solution, the gas-assisted electrospray delivered satisfactory sensitivity and stability for routine mass analyses.  相似文献   

18.
In electrospray ionization mass spectrometry (ESI-MS) of polypropyleneglycol (PPG), effects of cationizing agents were examined. When NaI was used as a cationizing agent, the distribution of multiply-charged ions in the spectra was greatly affected by the ratio of cationizing agent and PPG. However, the distribution was not affected by the use of CH(3)COONH(4). With an increase of cone voltage, fragmentation occurred by in-source collision-induced dissociation (CID) when CH(3)COONH(4) was used. On the contrary, no decomposition of the PPG backbone was observed with NaI. Instead, the intensity of the lower-charged ions, whose mass-to-charge (m/z) ratios are larger, increased because of the elimination of Na(+) with increase of cone voltage. Under optimum conditions for ESI-MS analysis, PPGs that have different molecular weights, different initiators or end groups were easily and accurately characterized. A tandem mass spectrometry (MS/MS) study of NH(4)(+) adduct ions of PPG indicated that a vinyl-terminated linear structure is formed at the end group during the fragmentation.  相似文献   

19.
By electrospray ionization (ESI) mass spectrometry, micelle solutions of sodium cholate were investigated in detail in the presence and absence of ethanol. The average aggregation number could be evaluated from the spectra acquired under conditions where soft collisions adequate to measure the micelle solution were induced, and the value agreed well with that obtained previously by other methods. From the dependence on ethanol content, it was also found that the average aggregation number in aqueous solution without organic solvent could be reliably estimated. The ESI method proved to be a useful tool for determining the micelle mass in the original aqueous phase.  相似文献   

20.
Isobaric product ions cannot be differentiated by exact mass determinations, although in some cases deuterium labeling can provide useful structural information for identifying isobaric ions. Proposed fragmentation pathways of fentanyl were investigated by electrospray ionization ion trap mass spectrometry coupled with deuterium labeling experiments and spectra of regiospecific deuterium labeled analogs. The major product ion of fentanyl under tandem mass spectrometry (MS/MS) conditions (m/z 188) was accounted for by a neutral loss of N‐phenylpropanamide. 1‐(2‐Phenylethyl)‐1,2,3,6‐tetrahydropyridine (1) was proposed as the structure of the product ion. However, further fragmentation (MS3) of the fentanyl m/z 188 ion gave product ions that were different from the product ion in the MS/MS fragmentation of synthesized 1, suggesting that the m/z 188 product ion from fentanyl includes an isobaric structure different from the structure of 1. MS/MS fragmentation of fentanyl in deuterium oxide moved one of the isobars to 1 Da higher mass, and left the other isobar unchanged in mass. Multistage mass spectral data from deuterium‐labeled proposed isobaric structures provided support for two fragmentation pathways. The results illustrate the utility of multistage mass spectrometry and deuterium labeling in structural assignment of isobaric product ions. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号