首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this report, matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was used to study the binding interactions between calmodulin and two target peptides (melittin and substance P). Various matrix conditions were tested and the less acidic matrix DHAP and THAP were found to favor the survival of the intact calcium-calmodulin as well as the calmodulin-peptide complexes. However, the application of direct MALDI-MS to detect the intact complexes turned out to be very difficult due to the dissociation of the complexes and the formation of nonspecific aggregates. In contrast, the specific binding of the target peptides to calmodulin could be easily deduced using intensity-fading (IF) MALDI-MS. Compared with the nonbinding control, clear reduction in the ion abundances of the target peptides was observed with the addition of calmodulin. Relative binding affinities of different peptides towards the protein could also be estimated using IF-MALDI-MS. This study may extend the application of IF-MALDI-MS in the analysis of noncovalent complexes and offer a perspective into the utility of MALDI-MS as an alternative approach to study the peptides binding to calmodulin.  相似文献   

2.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) has been used successfully to detect phosphorylation sites in proteins. Applications may be limited by the low response of phosphopeptides compared to nonphosphorylated peptides in MALDI MS. The addition of ammonium salts to the matrix/analyte solution substantially enhances the signal for phosphopeptides. In examples shown for equimolar mixtures, the phosphorylated peptide peaks become the largest peaks in the spectrum upon ammonium ion addition. This can allow for the identification of phosphopeptides in an unfractionated proteolytic digestion mixture. Sufficient numbers of protonated phosphopeptides can be generated such that they can be subjected to postsource decay analysis, in order to confirm the number of phosphate groups present. The approach works well with the common MALDI matrices such as α-cyano-4-hydroxycinnamic acid and 2,5-dihydroxybenzoic acid, and with ammonium salts such as diammonium citrate and ammonium acetate.  相似文献   

3.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was used to detect an immune complex formed between beta-lactoglobulin and polyclonal anti-beta-lactoglobulin antibody in the gas phase. The most important experimental parameters to detect such a specific antibody-antigen complex by MALDI were the use of solutions at near-neutral pH and of sinapinic acid matrix prepared by the dried-droplet method. Under such conditions, predominantly one but also two molecules of antigen protein were complexed by the antibody. Specific formation of the antibody-antigen complex was confirmed by performing competitive reactions. Addition of antibody to a 1:1 mixture of beta-lactoglobulin and one control protein resulted not only in the appearance of the expected antibody-antigen complex, but also in a strong decrease in the free beta-lactoglobulin signal, while the abundance of the control protein was not influenced.  相似文献   

4.
Daniel JM  Ehala S  Friess SD  Zenobi R 《The Analyst》2004,129(7):574-578
A new technique is presented for the coupling of atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) mass spectrometry with liquid delivery systems. Mass measurements of polymers and peptides are demonstrated using a co-dissolved matrix, e.g. alpha-cyano-4-hydroxycinnamic acid (HCCA). Improvements in terms of sensitivity are achieved by optimizing the shape und control of the exit capillary and by using a laser (355 nm) at a 1 kHz repetition rate. Two calibration experiments promise a good applicability of the presented coupling method for quantitative measurements. The limit of detection achieved so far is 500 nM for peptides in methanol solution containing 25 mM HCCA.  相似文献   

5.
Matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry is generally considered to be a surface analysis technique. In this report, the profiling depth of imaging mass spectrometry was examined. MALDI matrix solution was found to be able to gain access to the tissue interior and extract analyte molecules to the tissue surface. As a consequence, prazosin, a small molecule pharmaceutical compound, located as deep as 40 microm away from the surface was readily detected after matrix application. Likewise, cytochrome c, a 12 kDa protein, was also detectable from the tissue interior. Moreover, for prazosin, not only the extent of matrix effect, but also the extraction efficiency of the matrix solvent appeared to be dependent on the type of tissue. These results indicated that experimental conditions that decrease the matrix solvent evaporation during matrix application may increase analyte extraction efficiency and hence sensitivity of the analysis. Furthermore, thin sections should be used to avoid differential extraction efficiency of matrix solvent in different tissues for whole-body analysis.  相似文献   

6.
Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) has successfully been used to differentiate pseudo-enantiomeric (isotopically labelled) amino acids by using cyclodextrin as complexing host. By using different pseudo-enantiomeric mixtures (i.e. R(Dn) + S; and R + S(Dn)), it has been demonstrated that the preference of cyclodextrin for S-enantiomers is not due to the size differences caused by the hydrogen/deuterium substitution. It is postulated that this method can be extended to differentiate enantiomers (and determine enantiomeric excess) by using a pair of enantiomeric hosts, as demonstrated previously using other ionization techniques, but with much higher sensitivity.  相似文献   

7.
8.
The use of matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry (MS) for the quantitative determination of phospholipid (PL) molecular species has been problematic, due primarily to the formation of multiple signals (corresponding to the molecular ion and other adducts) for some classes of PL. For example, analysis of phosphatidylcholine (PC) yielded signals that corresponded to protonated and sodiated molecules in the MALDI spectrum. The resulting spectral overlap among various molecular species (e.g. [PC(16:0/18:2) + Na] and [PC(18:2/18:3)]) made it impossible to ascertain their relative amounts using this technique. Other spectral ambiguities existed among different structural isomers, such as PC(18:1/18:1) and PC(18:0/18:2). We determined that molecular species could be resolved by MALDI-TOFMS by first removing the polar head (e.g. phosphocholine) from the phospholipid to effect production of only the sodiated molecules of the corresponding diacylglycerols (DAGs). Analysis of the resulting spectrum allowed unequivocal determination of the molecular species profile of PC from potato tuber and soybean. Estimation of fatty acid composition based on the molecular species determined by MALDI-TOFMS analysis agreed with that from GC-FID analysis. Post-source decay (PSD) was used to resolve standard isomers of PC (e.g. 18:1/18:1 vs. 18:0/18:2). Our results indicated that PSD is a useful approach for resolving structural isomers of PL molecular species.  相似文献   

9.
This study presents matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) as a powerful tool to analyze and characterize oligonucleotides covalently linked to a solid support during their synthesis. The analysis of the fragment ions generated either in negative or positive mode allows direct and easy access to the nucleotide sequence and identification of the internucleosidic linkage. The mechanisms of the fragmentation of the solid-supported oligonucleotides induced by MALDI-TOFMS are discussed. Copyright 2000 John Wiley & Sons, Ltd.  相似文献   

10.
Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) and laser desorption/ionization (LDI-)TOFMS have been used to characterize Suwannee River humic substances, obtained from the International Humic Substances Society (IHSS), and Armadale soil fulvic acid (ASFA). An array of MALDI matrices were tested for use with humic substances, including alpha-cyano-4-hydroxycinammic acid (CHCA), 2-(4-hydroxyphenylazo)benzoic acid (HABA), 2,5-dihydroxybenzoic acid (DHBA), sinapinic acid, dithranol and norharmane. DHBA yielded the best results, exhibiting superior ionization efficiency, low noise, broad applicability to the analytes of interest, and most importantly producing an abundance of high mass ions, the highest observed being m/z 1848. A number of sample preparation modes were investigated; the overlayer method improved sample/matrix homogeneity and hence shot-to-shot reproducibility. The choice of the matrix, mass ratio of analyte to matrix, and the sample preparation protocol, were found to be the most critical factors governing the quality of the mass spectra. Matrix suppression was greatly enhanced by ensuring good mixing of matrix and analyte in the solid phase, proper optimization of the matrix/analyte ratio, and optimizing delayed extraction to ensure complete matrix-analyte reaction in the plume before ions are moved to the flight tube. A number of common features, in particular specific ions which could not be attributed to the matrices or to contaminants, were present in the spectra of all the humic substances, regardless of origin or operational definition. Additionally, a prominent repeating pattern of peaks separated by 55, 114 and 169 Da was clearly observed in both LDI and MALDI, suggesting that the humic compounds studied here may have quasi-polymeric or oligomeric features.  相似文献   

11.
A study of the collision-induced dissociation post-source decay (PSD) spectra of free oligosaccharides is presented. These spectra, when obtained with helium as collision gas, show (1,5)X fragments containing the reducing end sugar. The presence of these fragments permits Y ions and, consequently, B and C peaks to be identified. This is a common behaviour from which it has been possible to delineate a general method for the easy assignment of the peaks in PSD spectra of underivatized neutral sugars, allowing the sequence of a real unknown to be obtained.  相似文献   

12.
A simple, sensitive and fast method for the determination of melamine and its derivatives in milk powder using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was developed. Neither time-consuming sample preparation, nor special target plates, or other extra equipment are necessary. The common matrix sinapinic acid (SA) was used with a dried-droplet preparation. Detection limits (signal-to-noise (S/N) ratio = 3) for standard solutions of melamine, ammeline and cyanuric acid were 10, 25 and 10 μg/L, respectively. The limit of quantification (LOQ) for melamine was 25 μg/L and excellent linearity (R(2): 0.9990) was maintained over the range of 10-2000 μg/L. Ammeline and cyanuric acid were analyzed with an LOQ of 50 μg/L and also excellent linearity (R(2): 0.9997 and R(2): 0.9998). Good accuracy and precision were obtained for all concentrations within the range of the standard curve. The developed method was successfully used for the determination of melamine, ammeline and cyanuric acid in milk powder samples with a simple sample preparation. The LOQ of melamine was 0.5 μg/g. Ammeline and cyanuric acid were detectable at 0.5 and 5 μg/g. This method showed excellent accuracy, precision and linearity and significantly reduces the needed analysis time, as only approximately 10 s/sample measuring time is required. To the authors' knowledge, this is the first published method to quantify melamine and derivatives by MALDI-TOF-MS.  相似文献   

13.
We report the direct laser desorption/ionization (LDI) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometric (MALDI-TOFMS) analysis of four inorganic coordination complexes: monometallic [Ir(dpp)(2)Cl(2)](PF(6)), homonuclear trimetallic ([(bpy)(2)Ru(dpp)](2)RuCl(2))- (PF(6))(4), and heteronuclear [(tpy)Ru(tpp)Ru(tpp)RhCl(3)](PF(6))(4) and ([(bpy)(2)Ru(dpp)](2)IrCl(2))(PF(6))(5) (dpp = 2,3-bis-(2'-pyridyl)pyrazine, bpy = 2,2'-bipyridine, tpy = 2,2',6',2"-terpyradine, tpp = 2,3,5,6,-tetrakis-(2'-pyridyl)pyrazine). Spectral intensities and fragmentation patterns are compared and evaluated for instrument parameters, matrix selection, and matrix-to-analyte ratio. Direct LDI and MALDI mass spectra of the monometallic complex showed the same ion peaks and differed only in the relative peak intensities. Direct LDI of the trimetallic complexes produced only low-mass fragments containing one metal at most. MALDI spectra of the trimetallic complexes exhibited little fragmentation in the high-mass region (>1500 Da) and less fragmentation in the low-mass region compared to direct LDI. Significant fragments of the molecules were detected and identified, including ligand fragments, intermediate-mass fragments such as [Ru(tpy)](+), and molecular ions with varying degrees of PF(6)(-) loss ([M - n(PF(6))](+), where n = 1-3). A correlation exists between the solution-phase electrochemistry and the observed [M - n(PF(6))](+) series of peaks for the trimetallic complexes. Proper matrix selection for MALDI analysis was vital, as was an appropriate matrix-to-analyte ratio. The results demonstrate the applicability of MALDI-TOFMS for the structural characterization of labile inorganic coordination complexes.  相似文献   

14.
The intact fungal spores of several strains of four Aspergillus species, Aspergillus flavus, A. oryzae, A. parasiticus, and A. sojae, were directly analyzed by matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry. Very simple MALDI mass spectra are obtained by directly mixing spores with a matrix such as alpha-cyano-4-hydroxycinnamic acid or sinapinic acid. The mass spectra are obtained from the ablation of cell walls of spores owing to the acidity of the matrix solution. The MALDI results show that aflatoxigenic strains and non-aflatoxigenic strains have different mass peak profiles. Furthermore, the MALDI results of non-aflatoxigenic A. flavus and A. parasiticus spores resemble those of the closely related A. oryzae and A. sojae spores, respectively.  相似文献   

15.
Metal labelling of peptides and proteins using high-affinity metal-chelating compounds has found widespread applications in the medical and bioanalytical fields. In the present study we investigated the analysis of peptides derivatized either with cysteine- or amino group-directed metal-bound DOTA (1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid) chelators in matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). The metal complexes of DOTA were shown to be stable under MALDI-MS conditions. The introduction of the metal label led in a number of cases to significantly increased signal-to-noise (S/N) values and thus improved sensitivity of the labelled peptides compared to their unlabelled counterparts, especially for multiply labelled peptides. The presence of the labels did alter the tandem mass spectrometric (MS/MS) behaviour, namely the formation of sequence specific a-, b- and y-ion series, in dependence of the position of the label within the peptide sequence. For cysteine-derivatized peptides several label-specific reporter ions and characteristic immonium ions could be identified. Amino-directed labelling led only to the formation of characteristic immonium ions in ε-amino groups of lysine, whereas N-terminal labelling in some cases led to the formation of a(1)- and b(1)-ions. The results clearly show that MALDI-MS is suitable for the analysis of metal-labelled peptides, which was also confirmed in liquid chromatography (LC)/MALDI-based identification of proteins in a model protein mixture labelled with Cys-reactive DOTA. Here, in comparison to a run with alkylated cysteines, more than 50% more cysteine-containing peptides were identified.  相似文献   

16.
A novel method for acquisition and numerical analysis of matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectral data is described. The digitized ion current transient from each consecutive laser shot is first acquired and stored independently. Subsequently, statistical correlation parameters between all stored transients are computed. We illustrate the uses of this event-by-event analysis method for studies of sample surface heterogeneity as well as for elucidating the mechanisms of ion formation in MALDI. Other potential applications of the method are also outlined.  相似文献   

17.
The trend of miniaturization in bioanalytical chemistry is shifting from technical development to practical application. In matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), progress in miniaturizing sample spots has been driven by the needs to increase sensitivity and speed, to interface with other analytical microtechnologies, and to develop miniaturized instrumentation.We review recent developments in miniaturizing sample spots for MALDI-MS. We cover both target modification and microdispensing technologies, and we emphasize the benefits with respect to sensitivity, throughput and automation.We hope that this review will encourage further method development and application of miniaturized sample spots for MALDI-MS, so as to expand applications in analytical chemistry, protein science and molecular biology.  相似文献   

18.
The fungal spores of Penicillium expansum, P. chrysogenum, P. citrinum, P. digitatum, P. italicum, and P. pinophilum were characterized by using matrix-assisted laser desorption/ionization with time-of-flight mass spectrometry (MALDI-TOFMS). These fungal spores are frequently found in grain and fruit. The mass spectra of these six species were directly obtained from the intact spores without any pretreatment. The results obtained indicate that 2,5-dihydroxybenzoic acid and sinapinic acid are suitable matrices for the analysis of Penicillium spores. Characteristic ions representing the different species were obtained with sufficiently high reproducibility that these ions can be employed to identify the different fungal species. On the basis of these characteristic ions obtained from these authentic Penicillium spores, the approach was applied to characterize the fungal species contaminating the surfaces of fruit. It was demonstrated that the fungal spores directly scratched from the surfaces of fruit contaminated by unknown fungi can be rapidly identified using MALDI-TOFMS analysis without any tedious pretreatment.  相似文献   

19.
A method for the detection of BPDE-d guanosine adducts using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is described and illustrated. The results indicate that MALDI is capable of detecting two other DNA benzopyrene adducts, which are trace products formed during the synthesis of BPDE-d guanosine. This MALDI-TOFMS method offers the potential for the detection of DNA adducts in human tissue using very limited sample purification and preparation.  相似文献   

20.