1.
Urine uranium concentrations are the best biological indicator for identifying exposure to depleted uranium (DU). Internal exposure to DU causes an increased amount of urine uranium and a decreased ratio of 235U/238U in urine samples, resulting in measurements that vary between 0.00725 and 0.002 (i.e., natural and depleted uraniums 235U/238U ratios, respectively). A method based on inductively coupled plasma dynamic reaction cell mass spectrometry (ICP-DRC-MS) was utilized to identify DU in urine by measuring the quantity of total U and the 235U/238U ratio. The quantitative analysis was achieved using 233U as an internal standard. The analysis was performed both with and without the reaction gas oxygen. The reaction gas converted ionized 235U+ and 238U+ into 235UO2+ (m/z=267) and 238UO2+ (m/z=270). This conversion was determined to be over 90% efficient. A polyatomic interference at m/z 234.8 was successfully removed from the 235U signal under either DRC operating conditions (with or without oxygen as a reaction gas). The method was validated with 15 urine samples of known uranium compositions. The method detection limit for quantification was determined to be 0.1 pg U mL–1 urine and an average coefficient of variation (CV) of 1–2% within the sample measurements. The method detection limit for determining 235U/238U ratio was 3.0 pg U mL–1 urine. An additional 21 patient samples were analyzed with no information about medical history. The measured 235U/238U ratio within the urine samples correctly identified the presence or absence of internal DU exposure in all 21 patients.The opinions and assertions expressed herein are those of the authors and are not to be construed as official or as representing the views of the Armed Forces Institute of Pathology, the Department of the Army, or the Department of Defense  相似文献   

2.
A method for the determination of sixteen elements (Al, As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Mo, Ni, Pb, Se, Sn, V, Zn) in seafood by dynamic reaction cell inductively coupled plasma mass spectrometry (ICP–DRC–MS) is presented. A preliminary study of polyatomic interferences was carried out in relation to the chemical composition of marine organisms belonging to different taxa. Acid effects and other matrix effects in marine organisms submitted to closed-vessel microwave digestion were investigated as well. Ammonia was the reactive gas used in the DRC to remove polyatomic ions interfering with 27Al, 52Cr, 56Fe and 51V. Optimal conditions for the simultaneous determination of analytes were identified in order to develop a fast multielement method. A suite of real samples (mussels and various fish species) were used during method development along with three certified reference materials: BCR CRM 278R (mussel tissue), BCR CRM 422 (cod muscle) and DORM-2 (dogfish muscle). The proposed analytical approach can be used in conjunction with suitable chemometric procedures to address quality and safety issues in aquaculture and fisheries. As an example, a case study is described in which mussels from three farming sites in the Venice Lagoon were distinguished by multivariate analysis of element fingerprints.   相似文献   

3.
A.J. Bednar 《Talanta》2009,78(2):453-247
Recent advances in inductively coupled plasma mass spectrometry (ICP-MS) have included the addition of interference reduction technologies, such as collision and reaction cells, to improve its detection capability for certain elements that suffer from polyatomic interferences. The principle behind reaction cell (RC)-ICP-MS is to remove a particular polyatomic interference by dissociation or formation of a different polyatomic species that no longer interferes with the analyte of interest. However, some interferences cannot be removed by commonly reported reaction gases, such as hydrogen, oxygen, or methane, necessitating using more reactive and hazardous gases, such as ammonia. The current study investigates oxygen as a reaction gas in RC-ICP-MS to specifically react with vanadium analyte ions, rather than the interferents, to produce a polyatomic analyte species and thereby provide a way to analyze for vanadium in complex environmental matrices. The technique has been tested on a series of river water, tap water, and synthetic laboratory samples, and shown to be successful in vanadium analyses in high chloride and sulfate matrices. The zinc isobaric interference on the new vanadium oxide analyte at m/z 67 is also investigated, and can be corrected by using a standard mathematical correction equation. The results of this study further increase the utility of RC-ICP-MS analytical techniques for complex environmental matrices.  相似文献   

4.
Inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) have been applied as the most important inorganic mass spectrometric techniques having multielemental capability for the characterization of solid samples in materials science. ICP-MS is used for the sensitive determination of trace and ultratrace elements in digested solutions of solid samples or of process chemicals (ultrapure water, acids and organic solutions) for the semiconductor industry with detection limits down to sub-picogram per liter levels. Whereas ICP-MS on solid samples (e.g. high-purity ceramics) sometimes requires time-consuming sample preparation for its application in materials science, and the risk of contamination is a serious drawback, a fast, direct determination of trace elements in solid materials without any sample preparation by LA-ICP-MS is possible. The detection limits for the direct analysis of solid samples by LA-ICP-MS have been determined for many elements down to the nanogram per gram range. A deterioration of detection limits was observed for elements where interferences with polyatomic ions occur. The inherent interference problem can often be solved by applying a double-focusing sector field mass spectrometer at higher mass resolution or by collision-induced reactions of polyatomic ions with a collision gas using an ICP-MS fitted with collision cell. The main problem of LA-ICP-MS is quantification if no suitable standard reference materials with a similar matrix composition are available. The calibration problem in LA-ICP-MS can be solved using on-line solution-based calibration, and different procedures, such as external calibration and standard addition, have been discussed with respect to their application in materials science. The application of isotope dilution in solution-based calibration for trace metal determination in small amounts of noble metals has been developed as a new calibration strategy. This review discusses new analytical developments and possible applications of ICP-MS and LA-ICP-MS for the quantitative determination of trace elements and in surface analysis for materials science.  相似文献   

5.
An analytical method using double focusing sector field inductively coupled plasma mass spectrometry (ICP-SMS) for rapid simultaneous determination of 50 elements in digested human blood is described. Sample preparation consisted of microwave digestion with nitric acid followed by dilution with ultrapure water. The importance of controlling possible contamination sources at different sample preparation and analysis stages in order to achieve adequate method detection limits (MDL) is emphasised. Correction for matrix effects was made using scandium, indium and lutecium as internal standards. Accuracy of the data for elements suffering from spectral interferences was improved by applying either a high resolution capability of the ICP-SMS or mathematical corrections. Different approaches for accuracy assessment in blood analysis are evaluated. Additional information on trace elements concentration in selected blood reference materials is given. The between-batch precision was assessed from replicate analysis (including sample preparation) of reference materials and was better than 10% RSD for 21 elements and better than 30% RSD for 36 elements under consideration. A statistical summary for results obtained for 31 blood samples from non-exposed subjects is presented. The majority of elements tested was found in the samples at concentrations higher than MDL.  相似文献   

6.
An analytical method using double focusing sector field inductively coupled plasma mass spectrometry (ICP-SMS) for rapid simultaneous determination of 50 elements in digested human blood is described. Sample preparation consisted of microwave digestion with nitric acid followed by dilution with ultrapure water. The importance of controlling possible contamination sources at different sample preparation and analysis stages in order to achieve adequate method detection limits (MDL) is emphasised. Correction for matrix effects was made using scandium, indium and lutecium as internal standards. Accuracy of the data for elements suffering from spectral interferences was improved by applying either a high resolution capability of the ICP-SMS or mathematical corrections. Different approaches for accuracy assessment in blood analysis are evaluated. Additional information on trace elements concentration in selected blood reference materials is given. The between-batch precision was assessed from replicate analysis (including sample preparation) of reference materials and was better than 10% RSD for 21 elements and better than 30% RSD for 36 elements under consideration. A statistical summary for results obtained for 31 blood samples from non-exposed subjects is presented. The majority of elements tested was found in the samples at concentrations higher than MDL. Received: 23 November 1998 / Revised: 6 January 1999 / Accepted: 12 January 1999  相似文献   

7.
The analytical performance of inductively coupled plasma mass spectrometry (ICP-MS) for the analysis of plant sample digests was evaluated using double focusing sector field ICP-MS (ICP-SMS). Instrumental detection limits of ICP-SMS are superior to those obtained by quadrupole systems (ICP-QMS) and reach the fg mL–1 range for elements with high m/z ratios. Matrix effects caused by a plant digest after sample preparation resulting in 200-fold dilution were found to be negligible. The usefulness of high mass resolution for overcoming some spectral interferences is demonstrated. Mathematical correction possibilities could be necessary to improve accuracy. The concentrations of more than 20 elements can be determined in 5 min and only one internal standard is necessary to correct for instrumental drift. Received: 30 March 1998 / Revised: 4 May 1998 / Accepted: 16 May 1998  相似文献   

8.
The analytical performance of inductively coupled plasma mass spectrometry (ICP-MS) for the analysis of plant sample digests was evaluated using double focusing sector field ICP-MS (ICP-SMS). Instrumental detection limits of ICP-SMS are superior to those obtained by quadrupole systems (ICP-QMS) and reach the fg mL–1 range for elements with high m/z ratios. Matrix effects caused by a plant digest after sample preparation resulting in 200-fold dilution were found to be negligible. The usefulness of high mass resolution for overcoming some spectral interferences is demonstrated. Mathematical correction possibilities could be necessary to improve accuracy. The concentrations of more than 20 elements can be determined in 5 min and only one internal standard is necessary to correct for instrumental drift. Received: 30 March 1998 / Revised: 4 May 1998 / Accepted: 16 May 1998  相似文献   

9.
A sensitive and efficient flow-injection (FI) preconcentration and matrix-separation technique coupled to sector field ICP–mass spectrometry (SF-ICP–MS) has been developed and validated for simultaneous determination of ultra-low levels of uranium (U) and thorium (Th) in human urine. The method is based on selective retention of U and Th from a urine matrix, after microwave digestion, on an extraction chromatographic TRU resin, as an alternative to U/TEVA resin, and their subsequent elution with ammonium oxalate. Using a 10 mL sample, the limits of detection achieved for 238U and 232Th were 0.02 and 0.03 ng L–1, respectively. The accuracy of the method was checked by spike-recovery measurements. Levels of U and Th in human urine were found to be in the ranges 1.86–5.50 and 0.176–2.35 ng L–1, respectively, well in agreement with levels considered normal for non-occupationally exposed persons. The precision obtained for five replicate measurements of a urine sample was 2 and 3% for U and Th, respectively. The method also enables on-line measurements of the 235U/238U isotope ratios in urine. Precision of 0.82–1.04% (RSD) was obtained for 235U/238U at low ng L–1 levels, using the FI transient signal approach.  相似文献   

10.
Capillary electrophoresis dynamic reaction cell™ inductively coupled plasma mass spectrometry (CE-DRC-ICP-MS) for the determination of sulfur-containing amino acids is described. The sulfur-containing amino acids studied include l-cysteine, l-cystine, dl-homocystine and l-methionine. The species studied were well separated using a 70 cm length×75 μm i.d. fused silica capillary while the applied voltage was set at +22 kV and a 10 mmol l−1 disodium tetraborate buffer (pH 9.8) containing 0.1 mmol l−1 EDTA and 0.5 mmol l−1 Triton X-100 was used as the electrophoretic buffer. The sulfur-selective electropherogram was determined at m/z 48 as by using its reaction with O2 in the reaction cell. The method avoided the effect of polyatomic isobaric interferences at m/z 32 caused by and on by detecting as the oxide ion at m/z 48, which is less interfered. The detection limit of various species studied was in the range of 0.047-0.058 μg S ml−1, which corresponded to the absolute detection limit of 1.3-1.6 pg S based on the injection volume of 27 nl. We determined the concentrations of selected sulfur-containing amino acids in urine and nutritive complement samples. The recovery was in the range of 92-128% for various species.  相似文献   

11.
Simultaneous and multi-elemental method was optimized to determine 35 elements in 274 coarse and fine aerosol samples by using HR-ICP-MS. The procedures were validated. Measurement uncertainties of all elements including sampling uncertainties were calculated by applying bottom-up approach. The average recoveries obtained for each element ranged between 79% and 129% using NIST SRM 1648, urban dust. The calculated uncertainties of the analytical methods were between 2.9% and 18% for both sample types. The major contributions to the uncertainty budget come from the calibration curves, repeatability and volume of air.  相似文献   

12.
A low pressure microwave assisted vapor phase dissolution procedure for silicon nitride and volatilization of in situ generated SiF4 has been developed using H2SO4, HF and HNO3 for the determination of trace impurities present in silicon nitride. Sample was taken in minimum amount (0.5 mL for 100 mg) of H2SO4 and treated with vapors generated from HF and HNO3 mixture in presence of microwaves in a closed container. An 80 psi pressure with ramp and hold times of 30 min and 60 min respectively, operated twice, resulted in 99.9% volatilization of Si. Matrix free solutions were analyzed for impurities using DRC-ICP-MS. The recoveries of Cr, Mn, Fe, Ni, Co, Cu, Zn, Sr, Y, Cd, Ba and Pb were between 80 and 100% after volatilization of Si. The blanks were in lower ng g−1 with method detection limits in lower ng g−1 to sub ng g−1 range. The method was applied for the analysis of two silicon nitride samples.  相似文献   

13.
A method for the isotopic determination of selenium in biological matrices is described. The method is based on hydride generation inductively coupled plasma mass spectrometry (ICP-MS). The development is specifically related to the requirements of stable isotope tracer studies in human subjects. The method is based on isotope dilution using 82Se as the in vitro spike and can quantify the 74Se and 77Se contents of samples. It involves wet oxidation (HNO3 - H2O2 or HNO3 - HClO4) of the 82Se-spiked matrix, reduction to selenite by boiling with HCl followed by measurement of the isotope ratios (82Se/77Se and 74Se/77Se) in the gas stream (H2Se) generated from on-line reduction of the sample selenite with NaBH4. Compared with the isotopic signal resulting from a selenite solution containing 5 ng ml-1 of Se, the total sample blank contributions at m/z = 74, 77 and 82 were less than 5% of the respective isotope signal. Worst-case absolute detection limits were 0.2-0.9 ng of Se, depending on the isotope used. Ion beam intensity ratios were measured with an over-all precision [relative standard deviation (RSD)] of 1% for both isotope pairs. Measured ratios (MRa/b) were stable during a given day's operation within the expected precision of the measurements but varied for different days. The magnitude of MRa/b was generally independent of the nature of the matrix. Highly linear relationships were found between ion beam intensity ratios (MRa/b) and the corresponding true isotope ratios for calibration solutions whose isotope ratios had been altered by as much as one order of magnitude.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
An inductively coupled plasma mass spectrometer (ICP–MS) equipped with a dynamic reaction cell (DRC) was used for the determination of Ca and P in foodstuffs. In this study, two different reaction gases, CH4 and O2, were introduced successively through the different channels to alleviate different interferences in the same analysis run. The effect of the operating conditions of the DRC system was studied to get the best signal-to-noise ratio for each element. The interfering 40Ar+ at m/z 40 was reduced in intensity by up to five orders of magnitude by using 1.0 mL min–1 CH4 as reaction cell gas in the DRC. On the other hand, by using O2 as the reaction gas, 31P+ was converted to 31P16O+ that could be detected at m/z 47 where there was less interference. The limits of detection for Ca and P were 0.2 ng mL–1 and 0.3 ng mL–1, respectively. This method was used to determine the concentrations of Ca and P and the ratio of Ca to P in NIST SRM 1549 non-fat milk powder and NIST RM 8345 whole milk powder reference materials and an infant milk powder and an infant cereal-rice sample purchased locally. The results for the reference samples agreed satisfactorily with the reference values. The accuracy of the determination was better than 4.1 and 0.9% for Ca and P, respectively. The results for infant milk powder and infant cereal were also found to be in good agreement with the value on the bottle label. Precision (RSD) between sample replicates was better than 4.8% for all the determinations.  相似文献   

15.
The determination of naturally occurring and anthropogenic radionuclides in the environment by inductively coupled plasma mass spectrometry has gained recognition over the last fifteen years, relative to radiometric techniques, as the result of improvement in instrumental performance, sample introduction equipment, and sample preparation. With the increase in instrumental sensitivity, it is now possible to measure ultratrace levels (fg range) of many radioisotopes, including those with half-lives between 1 and 1000 years, without requiring very complex sample pre-concentration schemes. However, the identification and quantification of radioisotopes in environmental matrices is still hampered by a variety of analytical issues such as spectral (both atomic and molecular ions) and non-spectral (matrix effect) interferences and instrumental limitations (e.g., abundance sensitivity).The scope of this review is to highlight recent analytical progress and issues associated with the determination of radionuclides by inductively coupled plasma mass spectrometry. The impact of interferences, instrumental limitations (e.g., degree of ionization, abundance sensitivity, detection limits) and low sample-to-plasma transfer efficiency on the measurement of radionuclides by inductively coupled plasma mass spectrometry will be described. Solutions that overcome these issues will be discussed, highlighting their pros and cons and assessing their impact on the measurement of environmental radioactivity. Among the solutions proposed, mass and chemical resolution through the use of sector-field instruments and chemical reactions/collisions in a pressurized cell, respectively, will be described. Other methods, such as unique sample introduction equipment (e.g., laser ablation, electrothermal vaporisation, high efficiency nebulization) and instrumental modifications/optimizations (e.g., instrumental vacuum, radiofrequency power, guard electrode) that improve sensitivity and performance will also be examined.  相似文献   

16.
电感耦合等离子体质谱法测定高纯钼中12种杂质元素   总被引:1,自引:0,他引:1  
采用反应池技术消除了复合离子对Ca、Fe和Si等元素的干扰,以内标校正法直接测定了其它9种元素。优化选择了测定同位素和内标元素,考察了基体效应对测定结果的影响,建立了电感耦合等离子体质谱测定了高纯钼中12种杂质元素含量的方法。方法测定下限介于0.10~0.37μg/g之间,加标回收率为93%~105%,RSD<10%。...  相似文献   

17.
With Regulation No. 1881/2006 the European Union fixed a maximum level for lead in milk. Consequently, there is the need to determine very low concentration of elements that may be present in milk in trace and ultratrace levels.Quadrupole inductively coupled plasma mass spectrometry (Q-ICP-MS) combined with dynamic reaction cell (DRC) has been widely employed in order to reach very low concentration, requested for this product. Furthermore, the DRC technology can help in removing polyatomic and argon-based interferences.In the present study, a method for the determination of arsenic, cadmium, chromium and lead in bovine milk was validated according to the EU common standards by means of DRC-ICP-MS. The main parameters evaluated in the validation were: recovery, repeatability and within-laboratory reproducibility, detection and quantification limits, linearity range and measurement uncertainty. Additionally, stability studies of the analyte in solution and ruggedness studies were carried out.The results obtained for limit of detection (LoD) and limit of quantification (LoQ) in μg kg−1 were respectively: As, 3.1 and 9.5; Cd, 0.08 and 0.24; Cr, 0.229 and 0.693; Pb, 0.5 and 1.5. While for the recovery: As, 91%; Cd 96%; Cr 99%; Pb, 95%. As for the repeatability: As, 7%; Cd, 3%; Cr, 6%; Pb, 4%.  相似文献   

18.
An inductively coupled plasma mass spectrometer (ICP-MS) was used as an ion chromatographic detector for the speciation of iodine and bromine. Gradient elution using NH4NO3 at pH 10 allowed the chromatographic separation of ionic iodine (I- and IO3-) and bromine (Br- and BrO3-) species in less than 8 min. Effluents from the ion-exchange column were delivered to the nebulization system of ICP-MS for the determination of I and Br. The potentially interfering 38Ar40ArH+ and 40Ar40ArH+ at the bromine masses m/z 79 and 81 were significantly reduced in intensity (by approximately two orders of magnitude) by using 0.6 mL min(-1) O2 as a reactive cell gas in the dynamic reaction cell (DRC). Moreover, the signal-to-background ratio at iodine mass m/z 127 increased significantly when O2 was used as the reaction gas. The detection limits were in the range of 0.001-0.002 and 0.03-0.04 ng mL(-1) for various I and Br compounds, respectively, based on the peak height. The relative standard deviation of the peak areas for five injections of a 2 ng mL(-1) I-, IO3- and 20 ng mL(-1) Br-, BrO3- mixture was in the range of 3-4%. The concentrations of I and Br compounds have been determined in selected water and urine samples. The spike recoveries were in the range of 94-102% for all of the determinations. This method has also been applied to determine various I and Br compounds in an NIST RM 8435 whole-milk powder reference material and a seaweed sample obtained locally. A microwave-assisted extraction method was used to extract these compounds, which were quantitatively leached with a 10% mass/volume (m/v) tetramethylammonium hydroxide (TMAH) solution in a focused microwave field within a period of 6 min. The major components of I and Br in milk powder and seaweed were I- and Br-.  相似文献   

19.
In this work, the potential of laser ablation–inductively coupled plasma–mass spectrometry for the fast analysis of polymers has been explored. Different real-life samples (polyethylene shopping bags, an acrylonitrile butadiene styrene material and various plastic bricks) as well as several reference materials (VDA 001 to 004, Cd in polyethylene) have been selected for the study. Two polyethylene reference materials (ERM-EC 680 and 681), for which a reference or indicative value for the most relevant metals is available, have proved their suitability as standards for calibration.Special attention has been paid to the difficulties expected for the determination of Cr at the μg g 1 level in this kind of materials, due to the interference of ArC+ ions on the most abundant isotopes of Cr. The use of ammonia as a reaction gas in a dynamic reaction cell is shown to alleviate this problem, resulting in a limit of detection of 0.15 μg g 1 for this element, while limiting only modestly the possibilities of the technique for simultaneous multi-element analysis. In this regard, As is the analyte most seriously affected by the use of ammonia, and its determination has to be carried out in vented mode, at the expense of measuring time.In all cases studied, accurate results could be obtained for elements ranging in content from the sub-μg g 1 level to tens of thousands of μg g 1. However, the use of an element of known concentration as internal standard may be needed for materials with a matrix significantly different from that of the standard (polyethylene in this work).Precision ranged between 5% and 10% RSD for elements found at the 10 μg g 1 level or higher, while this value could deteriorate to 20% for analytes found at the sub-μg g 1 level. Overall, the technique evaluated presents many advantages for the fast and accurate multi-element analysis of these materials, avoiding laborious digestion procedures and minimizing the risk of analyte losses due to the formation of volatile compounds.  相似文献   

20.
Uranium isotope ratio U 234/238 can be measured by commercial high-performance inductively coupled plasma mass spectrometry (ICP-MS) with good precision and accuracy (relative standard deviation RSD<2%). The method is based on acquiring the data using a peak jump mode and a collecting signal 10 times longer for low abundance isotopes. Uranium isotope standards U-005 to U-200 from the National Bureau of Standards (NBS) were used for method development. The optimum uranium concentration range for analysis for dissolved samples is from 50 to 200 g l–1.  相似文献   