首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
The ability of the 90 degrees-t1-180 degrees pulse sequence to produce accurate dipole-dipole coupling information in solids is investigated. To this end, the experimental 31P spin echo decays are measured for eighteen crystalline phosphides and phosphorus chalcogenides and compared with simulations, based on the known internuclear distances in these compounds. The experimental results are generally found accurate in compounds where the dominant contribution to the dipole-dipole coupling arises from nuclei in structurally inequivalent sites with large chemical shift anisotropies. For this situation, the quantum mechanical "flip-flop" term in the dipolar Hamiltonian is suppressed and the dipole-dipole coupling is entirely heteronuclear in character. All of those compounds that do not obey this condition show accelerated spin echo decays due to a fractional contribution of the flip-flop term and possibly incomplete refocusing of chemical shift terms on the time scale of the experiment. The results confirm on an empirical basis that the spin echo NMR technique can provide accurate dipole-dipole coupling information (and thus distance distributions) in disordered solids and glasses.  相似文献   

3.
4.
The successful measurement of anisotropic NMR parameters like residual dipolar couplings (RDCs), residual quadrupolar couplings (RQCs), or residual chemical shift anisotropy (RCSA) involves the partial alignment of solute molecules in an alignment medium. To avoid any influence of the change of environment from the isotropic to the anisotropic sample, the measurement of both datasets with a single sample is highly desirable. Here, we introduce the scaling of alignment for mechanically stretched polymer gels by varying the angle of the director of alignment relative to the static magnetic field, which we call variable angle NMR spectroscopy (VA-NMR). The technique is closely related to variable angle sample spinning NMR spectroscopy (VASS-NMR) of liquid crystalline samples, but due to the mechanical fixation of the director of alignment no sample spinning is necessary. Also, in contrast to VASS-NMR, VA-NMR works for the full range of sample inclinations between 0° and 90°. Isotropic spectra are obtained at the magic angle. As a demonstration of the approach we measure 13C-RCSA values for strychnine in a stretched PDMS/CDCl? gel and show their usefulness for assignment purposes. In this context special care has been taken with respect to the exact calibration of chemical shift data, for which three approaches have been derived and tested.  相似文献   

5.
Nuclear Magnetic Resonance (NMR) technique is widely used as a powerful tool to study the physical and chemical properties of materials. However, this technique is limited to the materials in condensed phases. To extend this technique to the gas-phase molecular ions, we are developing a gas-phase NMR apparatus. In this note, we describe the basic principle of the NMR detection for molecular ions in the gas phase based on a Stern-Gerlach type experiment in a Penning trap and outline the apparatus under development. We also present the experimental procedures and the results on the formation and the manipulation of cold ions under a strong magnetic field, which are the key techniques to detect the NMR by the present method.  相似文献   

6.
Solid-state varible-temperature/magic angle spinning(VT/MAS) 1H NMR measurements were carried out on deuterated polyethylene. From these experimental results it was found that the 1H chemical shift induced by conformational and morphological changes of the polyethylene sample is within the linewidth of ≈ 0.5 ppm. Furthermore, from MAS/dipolar decoupling experiments it was found that the resonance frequency of the proton varies linearly with the inverse square of the deuterium decoupling power. This experimental finding is discussed theoretically.  相似文献   

7.
We discuss a method to determine temperature in a static NMR experiment from the temperature variation of the lead nitrate peak shift.  相似文献   

8.
Nonparametric NMR spectroscopy   总被引:1,自引:0,他引:1  
The parametric (or model-based) approach to NMR spectroscopy suffers from two general problems: it is sensitive to modeling errors and requires knowledge of the number of resonances present in the compound(s) under analysis. The nonparametric approach has neither of these drawbacks and it may also be computationally simpler than the parametric approach. However, if not applied properly, the nonparametric approach may yield significantly less accurate spectroscopic results than the parametric approach. In this paper we introduce a high-resolution nonparametric methodology for NMR spectroscopy based on the adaptive filter bank approach. The main salient feature of the new approach is that it provides 2D spectra versus both frequency and damping, as opposed to the classical 1D frequency spectra routinely used in NMR spectroscopy. To show the power of our new nonparametric approach we compare its performance with the ultimate performance of the parametric approach. We use both simulated and real NMR signals in our numerical performance study.  相似文献   

9.
10.
11.
12.
13.
14.
We briefly summarize the reported anomalous effects in deuterated metals at ambient temperature commonly known as cold fusion (CF) with an emphasis on the latest experiments, as well as the theoretical basis for the opposition to interpreting them as cold fusion. Then we critically examine more than 25 theoretical models for CF, including unusual nuclear and exotic chemical hypotheses. We conclude that they do not explain the data.  相似文献   

15.
We present robust radio frequency (rf) pulses that tolerate a factor of six inhomogeneity in the B? field, significantly enhancing the potential of toroid cavity resonators for NMR spectroscopic applications. Both point-to-point (PP) and unitary rotation (UR) pulses were optimized for excitation, inversion, and refocusing using the gradient ascent pulse engineering (GRAPE) algorithm based on optimal control theory. In addition, the optimized parameterization (OP) algorithm applied to the adiabatic BIR-4 UR pulse scheme enabled ultra-short (50 μs) pulses with acceptable performance compared to standard implementations. OP also discovered a new class of non-adiabatic pulse shapes with improved performance within the BIR-4 framework. However, none of the OP-BIR4 pulses are competitive with the more generally optimized UR pulses. The advantages of the new pulses are demonstrated in simulations and experiments. In particular, the DQF COSY result presented here represents the first implementation of 2D NMR spectroscopy using a toroid probe.  相似文献   

16.
17.
We demonstrate phase-coherent Stark effects from a radiofrequency E field at twice the NMR frequency (2ω(0)) of (69)Ga in GaAs. The 2ω(0) phase (?(E)) selects component responses from the nuclear quadrupole Hamiltonian (H(Q)). This is possible by synchronizing few-μs 2ω(0) pulses with an NMR line-narrowing sequence, which averages the Stark interaction to dominate spectra on a background with 10(3)× enhanced resolution. Spectra vs ?(E) reveal relative sizes of tensorial factors in H(Q). Comparative modeling and numerical simulations evaluate spectral features unexplained by average Hamiltonian theory, and suggest improvements for quantitative calibration of individual response components. Application of this approach to bulk samples is of value to define Stark responses that may later be used to interrogate the internal electrostatics of structured samples.  相似文献   

18.
19.
Ultrafast 2D NMR replaces the time-domain parametrization usually employed to monitor the indirect-domain spin evolution, with an equivalent encoding along a spatial geometry. When coupled to a gradient-assisted decoding during the acquisition, this enables the collection of complete 2D spectra within a single transient. We have presented elsewhere two strategies for carrying out the spatial encoding underlying ultrafast NMR: a discrete excitation protocol capable of imparting a phase-modulated encoding of the interactions, and a continuous protocol yielding amplitude-modulated signals. The former is general but has associated with it a number of practical complications; the latter is easier to implement but unsuitable for certain 2D NMR acquisitions. The present communication discusses a new protocol that incorporates attractive attributes from both alternatives, imparting a continuous spatial encoding of the interactions yet yielding a phase modulation of the signal. This in turn enables a number of basic experiments that have shown particularly useful in the context of in vivo 2D NMR, including 2D J-resolved and 2D H,H-COSY spectroscopies. It also provides a route to achieving sensitivity-enhanced acquisitions for other homonuclear correlation experiments, such as ultrafast 2D TOCSY. The main features underlying this new spatial encoding protocol are derived, and its potential demonstrated with a series of phase-modulated homonuclear single-scan 2D NMR examples.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号