首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
On-line atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) liquid chromatography/mass spectrometry (LC/MS) were evaluated for the analysis of a variety of steroids. Steroids were classified into three major groups based on the spectra and the sensitivities observed: (I) those containing a 3-one, 4-ene functional group, (II) those containing at least one ketone group without conjugation, and (III) those containing hydroxy group(s) only. In the APCI mode, the best sensitivity and the lowest detection limit for all three groups were obtained by using a mobile phase consisting of methanol and 1%–2% acetic acid in water. The APCI spectra were characterized by MH+, MH+-H2O, MH+-2H2O, etc., with the degree of H2O loss being compound dependent: group I steroids produced stable MH+ and group III steroids showed extensive water loss. In the electrospray mode the best sensitivity and the lowest detection limit for the first two groups were obtained when pure methanol and water were used as the mobile phase. This condition produced abundant stable MNa+ due to ubiquitous sodium. Detection limits in the 5–15 pg range can be easily achieved using ESI LC/MS. Addition of ammonium acetate or use of acetonitrile in the mobile phase, common in the LC/MS analysis of steroids, decreased the sensitivity for the group I and II steroids and thus should be avoided. For group III steroids, the detection limit can be improved by the addition of acetic acid to the mobile phase.  相似文献   

2.
Interlaboratory validation studies have been performed on 2 methods for the determination of chlormequat (CLQ) and mepiquat (MPQ). Both methods used identical extraction procedures and stable isotope internal standardization but differed in the use of liquid chromatography/mass spectrometry (LC/MS) or LC/tandem mass spectrometry (LC/MS/MS) for the determination, the amount of internal standard used, and the expected limit of detection. After addition of deuterated internal standards, CLQ and MPQ were extracted with methanol-water and determined by LC//MS or LC/MS/MS with positive electrospray ionization. Eight European laboratories participated in the LC/MS method study, analyzing mushroom, pear, wheat flour, and fruit puree with residues of CLQ in the range 0.040-1.19 mg/kg and of MPQ in the range 0.041-0.39 mg/kg. For CLQ, the Horwitz ratio (HoRat) values for individual test materials/levels were in the range 0.85-1.13 with a mean of 1.00, showing good method performance. For MPQ, the Ho values for mushroom, pear (both levels), and wheat flour were in the range 0.83-0.94, again indicating good method performance. For the determination of MPQ in infant food (fruit puree) at 0.041 mg/kg, the Ho was 1.7 when a value of 0 reported by one participant was excluded. In the LC/MS/MS study, in which 11 laboratories participated, a separate sample set was analyzed with residues of CLQ in the range 0.007-1.03 mg/kg and of MPQ in the range 0.008-0.72 mg/kg. Ho values for CLQ were in the range 0.27-1.36 and for MPQ in the range 0.51-2.10, all corresponding to acceptable method performance.  相似文献   

3.
Phenylketonuria is a common metabolic disorder disease. Those affected appear normal at birth, but without treatment they develop severe psychomotor retardation. Throughout life, they must control their blood levels of phenylalanine (Phe) and consume a diet containing adequate amounts of Phe and tyrosine (Tyr). We have developed a liquid chromatographic/mass spectrometric (LC/MS) method for the quantitative evaluation of Phe and Tyr in food samples. This method takes advantage of the good separation of LC and the selective and reliable quantification provided by MS in the electrospray ionization mode. The LC/MS method is very suitable for the determination of selected amino acids in various matrixes. It is sensitive to levels as low as about 0.30 ppm for Tyr and 0.70 ppm for Phe and robust. Nearly 100 nondietary food samples were analyzed by the developed method.  相似文献   

4.
In conjunction with an AOAC Task Group on dietary supplements, a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was validated for measurement of 6 major alkaloids in raw ephedra sinica herb, ephedra extracts, ephedra tablets, complex dietary supplements containing ephedra, and a high-protein drink mix containing ephedra. The amount of ephedrine-type alkaloids present was determined by LC with mass selective detection. Six replicates of each matrix were analyzed on 3 separate occasions. The presence of 6 ephedrine-type alkaloids was detected at a level > 0.5 microg/g based on a 0.5 g sample. The standard curve range for this assay is from 0.02 to 1.0 microg/mL. Appropriate dilutions covered a wide range of specific alkaloid concentrations. The calibration curves for all 6 analytes had correlation coefficients > 0.995.  相似文献   

5.
The histamine level in tomato fruits and pastes was determined by 2 orthogonal techniques as a means of comparing accuracy. Close statistical agreement was found between assays for free histamine by capillary electrophoresis (with UV absorbance detection), and for the dansyl derivative by reversed-phase liquid chromatography (LC). Both techniques have adequate sensitivity for the analysis of endogenous histamine in tomatoes, but LC/electrospray tandem mass spectrometry was more sensitive by at least an order of magnitude, down to a level of 0.05 mg/kg.  相似文献   

6.
Gestrinone was studied by high performance liquid chromatography (HPLC) for screening and by gas chromatography/mass spectrometry (GC/MS) for confirmation. When the chromatograms of blank, spiked urine and dosed urine were compared by HPLC, two unknown metabolites were found and these were excreted as the conjugated forms. Metabolites 1 and 2 were tested by LC/MS and LC/MS/MS and both had parent ions at m/z 325. The fragment ion of metabolite 1 was at m/z 263 and ions for metabolite 2 were m/z 307 [MH - H(2)O](+), 289, 279 and 241. LC/MS/MS of m/z 263 as the parent ion of metabolite 1 gave fragment ions at m/z 245 and 217, which were assumed to be [263 - H(2)O](+) and [235 - H(2)O](+), respectively. The trimethylsilyl (TMS)-enol-TMS ether derivative of gestrinone displayed three peaks in its GC/MS chromatogram, formed by tautomerism.  相似文献   

7.
A highly sensitive and selective method that requires minimal sample preparation was developed for the confirmation and quantitation of cyclamate in a variety of foods by high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS). Sample preparation consisted of homogenization followed by extraction and dilution of cyclamate with water. HPLC separation was achieved using a bridged ethyl hybrid C18 high-pressure column with a mobile phase consisting of 0.15% acetic acid and methanol. Under electrospray ionization negative conditions, quantitation was achieved by monitoring the fragment m/z = 79.7 while also collecting parent ion m/z = 177.9. Two food matrixes, diet soda and jelly, were subjected to a validation procedure in order to evaluate the applicability of the method. The cyclamate limit of detection for both matrixes was determined to be 0.050 microg/g with a limit of quantitation of 0.150 microg/g. The correlation coefficient of the calibration curves was >0.9998 from 0.0005 to 0.100 microg/mL. The method has been used for the determination of cyclamate in several foods and the results are presented.  相似文献   

8.
A rapid confirmatory liquid chromatographic/tandem mass spectrometic method was developed for determination of chloramphenicol in bovine milk. Chloramphenicol was extracted directly from milk by solid-phase extraction on a C18 cartridge. The extract was further cleaned up on neutral aluminium oxide. Three transition products were monitored in negative ion mode after atmospheric pressure chemical ionization. The detection capability related to the transition product of lowest abundance was 0.03 microg/kg. The mean recovery was 90% at levels of 0.1-0.2 microg/kg. The relative repeatability standard deviations were 4.3, 3.8, and 2.8% at levels of 0.1, 0.2, and 1.0 microg/kg, respectively.  相似文献   

9.
A liquid chromatographic/tandem mass spectrometric method was developed and validated for the determination of chloramphenicol (CAP) in royal jelly. Royal jelly samples were first denatured with lead acetate solution, and the CAP was extracted with solid-phase extraction before separation by liquid chromatography. A triple-quadrupole mass spectrometer operated in the negative electrospray ionization and selected-reaction monitoring mode was used for the detection of CAP. For method validation, royal jelly samples were fortified at CAP levels between 0.1 and 10.0 microg/kg; at these levels, recovery values (internal standard-corrected) ranged from 93.3 to 105.0%, and the within-laboratory reproducibility (relative standard deviation) was < or = 9.1%. The decision limit was 0.07 microg/kg, and the detection capability was 0.1 microg/kg.  相似文献   

10.
For the determination of glutathione (GSH) and its oxidized form (GSSG) in spruce needles their electrospray mass and MS/MS spectra were recorded with an ion trap mass spectrometer (ITMS, LCQ, Finnigan) and a triple stage quadrupole mass spectrometer (TSQ, Quattro II, Micromass). A study of the stability of GSH in aqueous solutions shows the presence of dimeric and trimeric forms of GSH, as well as GSSG, GSH-sulfonate and GSH-sulfinic acid. The same components were also found in extracts of spruce needles. We developed an assay which is suitable for monitoring low concentrations of GSH and similar compounds in plant tissues, employing the sensitivity and specificity of LC/MS/MS. Preliminary results on the mass spectrometric determination of GSH in spruce needles are given.  相似文献   

11.
A rapid and sensitive method for the determination of miglitol in human plasma using voglibose as internal standard has been developed and validated. Samples of plasma were deproteinated with acetonitrile and washed with dichloromethane before being analyzed by reversed-phase high-performance liquid chromatography (HPLC). Separation was carried out on a short Nucleosil C(18) column (5 microm, 50 x 4.6 mm i.d.) using 10 mmol/L ammonium acetate at 1.0 mL/min as mobile phase. The detector was an Applied Biosystems Sciex API 4000 mass spectrometer using atmospheric pressure chemical ionization (APCI) for ion production. The instrument was operated at unit resolution in the multiple reaction monitoring mode. The assay was linear over the range 5.00-2000 ng/mL with a limit of detection of 1.00 ng/mL. Intra- and inter-day precision were <2.82% and <2.92%, respectively, with accuracy of 93.3-106%. The assay was successfully applied to a clinical pharmacokinetic study of miglitol given as a single oral dose (50 mg) to healthy volunteers.  相似文献   

12.
13.
Fluorotelomer alcohols (FTOHs) are important polyfluorinated raw materials that belong to the general category of perfluoroalkyl substances (PFAS). PFAS, including perfluoroalkyl carboxylates (PFCAs) and perfluoroalkyl sulfonates, have recently attracted considerable attention because they are persistent and found globally in the environment. FTOHs are precursors that may degrade in the environment to PFCAs. The development of analytical methods for determination FTOHs in environmental samples is necessary to determine the environmental presence of FTOHs. This work presents the development and validation of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of FTOHs (6-2, 8-2, 10-2) in aqueous samples. Chromatographic conditions were optimized in order to obtain focused FTOH chromatographic peaks. The mobile phase and mass spectrometric conditions were optimized to enable formation of deprotonated FTOH molecules in the negative ion electrospray mode. Two extraction methods were investigated using acetonitrile and methyl tert-butyl ether (MTBE). These methods were validated for a range of environmental water samples fortified with FTOHs at three different levels. Both extraction methods resulted in recoveries from 70 to 120%. Detection limits of FTOHs were estimated to be approximately 0.09 ng/mL for LC/MS/MS detection. An LC/MS method was also developed for FTOH determination with an estimated 1.2 ng/mL limit of detection. Various sample storage scenarios were investigated. It was determined that the aqueous samples of FTOHs are best preserved by storing them frozen in sealed vials with aluminum foil lined septa.  相似文献   

14.
A sensitive and selective high-performance analytical method based on liquid chromatography with tandem mass spectrometric detection (LC/MS/MS) was developed for the quantification of glufosfamide in rat plasma. Zidovudine was employed as internal standard. Glufosfamide was determined after methanol-mediated plasma protein precipitation using LC/MS/MS with an electrospray ionization interface in negative ion mode. Two sets of standard curves were developed, from 0.005 to 1.0 microg/mL and from 1.0 to 50.0 microg/mL. The assay was accurate (% deviations from nominal concentrations < 5%), precise and reproducible (intra- and inter-day coefficients of variation < 10%). Glufosfamide in rat plasma was stable over three freeze/thaw cycles, and at ambient temperatures, for at least 2 h. The validated method was successfully applied to the determination of glufosfamide plasma concentrations in rats for 24 h following an intravenous administration of 25 mg/kg.  相似文献   

15.
Comprehensive analytical methods based on pressurized liquid extraction followed by normal-phase liquid chromatography (NPLC) with ultraviolet detection and reversed-phase liquid chromatography (RPLC)/electrospray mass spectrometry (MS) have been developed for determination of alkylphenol ethoxylates (APEOs) in textile samples. NPLC with an aminosilica column allowed for the chromatographic separation of APEOs according to the increasing number of ethylene units and revealed the exact distribution of individual oligomers. RPLC coupled with electrospray MS was highly sensitive and enabled the complete qualitative and quantitative determination of individual APEOs in textile samples. The 2 analytical methods based on different chromatographic separation mechanisms, i.e., NPLC and RPLC, may provide complementary information of APEOs in textile materials. The 2 detection methods were successfully applied to the investigation of various textile samples, and the data of our research suggested actual pollution in real textile products.  相似文献   

16.
Nandrolone (19‐nortestosterone) is an androgenic anabolic steroid illegally used as a growth‐promoting agent in animal breeding and as a performance enhancer in athletics. Therefore, its use was officially banned in 1974 by the Medical Commission of the International Olympic Committee (IOC). Following nandrolone administration, the main metabolites in humans are 19‐norandrosterone, 19‐norethiocolanolone and 19‐norepiandrosterone, and their presence in urine is the basis of detecting its abuse. The present work was undertaken to determine, in human urine, nandrolone metabolites (phase I and phase II) by developing and comparing multiresidue liquid chromatography/tandem mass spectrometry (LC/MS/MS) and gas chromatography/mass spectrometry (GC/MS) methods. A double extraction by solid‐phase extraction (SPE) was necessary for the complete elimination of the interfering compounds. The proposed methods were also tested on a real positive sample, and they allow us to determine the conjugated/free fractions ratio reducing the risk of false positive or misleading results and they should allow laboratories involved in doping control analysis to monitor the illegal use of steroids. The advantages of LC/MS/MS over GC/MS (which is the technique mainly used) include the elimination of the hydrolysis and derivatization steps: it is known that during enzymatic hydrolysis several steroids can be converted into related compounds and deconjugation is not always 100% effective. The validation parameters for the two methods were similar (limit of quantification (LOQ) <1 ng/mL and percentage coefficient of variance (CV%) <16.4), and both were able to confirm unambiguously all the analytes, thus confirming the validity of both techniques. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
18.
The analysis of pesticides in water samples is a problem of primary concern for quality control laboratories due to the toxicity level of these compounds and their public health risk. In order to evaluate the impact of pesticides in the Lisbon drinking water supply system, following the requirements of the European Union Directive 98/83/EC, we developed and validated an analytical method based on the combination of solid-phase extraction with liquid chromatography and tandem mass spectrometry. In this work, several pesticides were studied: imidacloprid, dimethoate, cymoxanil, carbendazime, phosmet, carbofuran, isoproturon, diuron, methidathion, linuron, pyrimethanil, methiocarbe, tebuconazole and chlorpyrifos. Several parameters of the electrospray source were optimized in order to get the best formation conditions of the precursor ion for each pesticide, namely capillary and extractor voltage, cone voltage, cone gas flow rate and desolvation gas flow rate. After optimization of the collision cell energy of the triple quadrupole, two different precursor ion-product ion transitions were selected for each pesticide, one for quantification and one for qualification, and these ions were monitored under time-scheduled multiple reaction monitoring (MRM) conditions. The selection of specific fragment ions for each pesticide guarantees a high degree of selectivity as well as additional sensitivity to quantify trace levels of these pesticides in water samples. This method showed excellent linearity ranges for all pesticides, with correlation coefficients greater than 0.9989. Determination limits (between 0.0041 and 0.0480 microg/L), precision (RSD <9.18%), accuracy and recovery studies in several water samples using solid-phase extraction were also performed.  相似文献   

19.
An analytical method was developed for the determination in urine of 2 metabolites of diazinon: 6-methyl-2-(1-methylethyl)-4(1H)-pyrimidinone (G-27550) and 2-(1-hydroxy-1-methylethyl)-6-methyl-4(1H)-pyrimidinone (GS-31144). Two of the urine sample preparation procedures presented rely on gas chromatography/mass selective detection (GC/MSD) in the selected ion monitoring mode for determination of G-27550. For fast sample preparation and a limit of quantitation (LOQ) of 1.0 ppb, urine samples were purified by using ENV+ solid-phase extraction (SPE) columns. For analyte confirmation at an LOQ of 0.50 ppb, classical liquid/liquid partitioning was used before further purification in a silica SPE column. An SPE sample preparation procedure and liquid chromatography/electrospray ionization/mass spectrometry/mass spectrometry (LC/ESI/MS/MS) were used for both G-27550 and GS-31144. The limit of detection was 0.01 ng for G-27550 with GC/MSD, and 0.016 ng when LC/ESI/MS/MS was used for both G-27550 and GS-31144. The LOQ was 0.50 ppb for G-27550 when GC/MSD and the partitioning/SPE sample preparation procedure were used, and 1.0 ppb for the SPE only sample preparation procedure. The LOQ was 1.0 ppb for both analytes when LC/ESI/MS/MS was used.  相似文献   

20.
Radical adducts of 5,5-dimethyl-1-pyrroline N-oxide (DMPO) with hydroxyl, methanol-derived, and ethanol-derived radicals were detected by a combination of liquid chromatography with either electron paramagnetic resonance or thermospray mass spectrometry (LC/EPR or LC/TSP-MS) in the Fenton system (with methanol or ethanol). One radical adduct was observed in the reaction of DMPO with the hydroxyl radical or the methanol-derived radical, while two adducts were detected in the reaction of DMPO with ethanol-derived radicals. The LC/TSP-MS spectra showed quasi-molecular ions [M + H]+ at m/z 146 and m/z 160 for the methanol-derived and ethanol-derived radical adducts, respectively, and an apparent molecular ion M+ at m/z 130 for the hydroxyl radical adduct. Use of methyl-D3 alcohol (CD3OH) and ethyl-D5 alcohol (CD3CD2OH) indicated that carbon-centered radicals are formed. Experiments with partially deuterated ethanol (CD3CH2OH and CH3CD2OH) indicated that the two adducts observed in the reaction of DMPO with ethanol-derived radicals correspond to the two diastereomeric adducts of DMPO with the alpha-hydroxyethyl free radical.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号