首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
张荣  刘昌辉  王宁生  宓穗卿 《色谱》2008,26(1):80-83
建立了一种快速、高效的以睾酮作为探针药物评价细胞色素P450 3A4(CYP3A4)酶活性的高效液相色谱-紫外检测方法。采用的色谱柱为Phenomenex C18柱(4.6 mm×150 mm,5 μm),梯度洗脱,流速1.0 mL/min,紫外检测波长245 nm,柱温30 ℃。睾酮与大鼠肝微粒体温孵后,过已活化好的C18固相萃取小柱,收集甲醇洗脱液,于37 ℃水浴中通N2吹干,用50%甲醇复溶后进样分析测定。研究结果表明,6β-羟基睾酮的 保留时间为11.60 min,线性范围为0.5~32 μg/mL,最低检出质量浓度为0.02 μg/mL,提取率为88.41%~92.73%,方法的回收率为99.07%~101.30%;睾酮的保留时间为19.27 min,线性范围为0.5~40 μg/mL,最低检出质量浓度为0.01 μg/mL,提取率为89.59%~92.66%,方法的回收率为96.50%~98.03%。两者的日内、日间相对标准偏差均小于10%,温孵体系中的其他内源性物质不干扰测定。该方法快速、稳定、灵敏度高,适合体外睾酮及其代谢物6β-羟基睾酮的测定,可应用于体外CYP3A4酶活性的评价及酶动力学的研究。  相似文献   

2.
张丹  曾经泽  边巴仓决  蒋学华 《色谱》1997,15(6):515-517
采用ODS柱,甲醇-稀磷酸溶液(7624)为流动相,260nm为检测波长,建立了测定血浆中吲哚美辛浓度的高效液相色谱法,并测定了吲哚美辛控释胶囊炎痛康的血药浓度。结果表明,血浆中吲哚美辛浓度在0.125~5.0mg/L范围内线性关系良好(r=0.9996),检测限62.5μg/L(S/N=31),平均回收率为100.4%,日内和日间RSD均小于5%。11位受试者单剂量口服炎痛康后的相对生物利用度为102.38%。  相似文献   

3.
A rapid procedure based on a direct extraction and HPLC determination with fluorescence detection of phenylephrine in pharmaceutical sachets that include a large excess of paracetamol (65 + 1, w/w), ascorbic acid (5 + 1, w/w), and other excipients (aspartame and sucrose) was developed and validated. The final optimized chromatographic method for ion-pair chromatography used an XTerra RP18 column, 3 microm particle size, 50 x 3.0 mm id. The mobile phase consisted of a mixture of acetonitrile and buffer (10 mM sodium octane-1-sulfonate, adjusted with H3PO4 to pH 2.2; 200 + 800, v/v), with a constant flow rate of 0.3 mL/min. The separation was carried out at 30 degrees C, and the injection volume was 3 microL. Fluorescence detection was performed at excitation and emission wavelengths of 275 and 310 nm, respectively. The mobile phase parameters, such as the organic solvent fraction (acetonitrile) in mobile phase as an organic modifier, the concentration of sodium octane-1-sulfonate as a counter-ion, temperature, and pH of mobile phase, were studied. As an alternative to ion-pair chromatography, hydrophilic interaction liquid chromatography (HILIC) was investigated using a Luna HILIC column, 3 microm, 100 x 4.6 mm id. The mobile phase consisted of acetonitrile and buffer (5 mM potassium dihydrogen phosphate, adjusted with H3PO4 to pH 2.5; 750 + 250, v/v) at a flow rate of 0.8 mL/min. The separation was carried out at 25 degrees C, and the injection volume was 5 microL. The proposed method has an advantage of a very simple sample pretreatment, and is much faster than the currently utilized HPLC methods using gradient elution and UV detection. Commercial samples of sachets were successfully analyzed by the proposed HPLC method.  相似文献   

4.
小白菜中残留虫酰肼的超临界流体萃取条件的研究   总被引:7,自引:0,他引:7  
杨立荣  张兴  陈安良  李广泽 《色谱》2004,22(3):263-266
将超临界流体萃取(supercritical fluid extraction,SFE)技术与高效液相色谱分析相结合,建立了特异性杀虫剂虫酰肼的萃取分离方法。SFE对虫酰肼的萃取条件:压力48.3 MPa(7000 psi),温度60 ℃,静态萃取时间20 min,CO2体积10 mL,改性剂甲醇添加量0.04 mL/g,丙酮为收集溶剂。在此条件下,SFE对虫酰肼的萃取率为100.75%,所得样品可直接用于高效液相色谱分析。色谱条件:紫外-二极管阵列检测器(检测波长为245 nm),C18键合色谱柱,乙腈  相似文献   

5.
A simple and sensitive high-performance liquid chromatography (HPLC) method has been developed for the determination of chlorogenic acid (3-O-caffeoyl-D-quinic acid) in plasma and applied to its pharmacokinetic study in rabbits after administration of Flos Lonicerae extract. Plasma samples are extracted with methanol. HPLC analysis of the extracts is performed on a C(18) reversed-phase column using acetonitrile-0.2% phosphate buffer (11:89, v/v) as the mobile phase. The UV detector is set at 327 nm. The standard curves are linear in the range 0.0500-1.00 microg/mL (r = 0.9987). The mean extraction recovery of 85.1% is obtained for chlorogenic acid. The interday precision (relative standard deviation) ranges from 5.0% to 7.5%, and the intraday precision is better than 9.0%. The limit of quantitation is 0.0500 microg/mL. The plasma concentration of chlorogenic acid shows a C(max) of 0.839 +/- 0.35 microg/mL at 34.7 +/- 1.1 min and a second one of 0.367 +/- 0.16 microg/mL at 273.4 +/- 39.6 min.  相似文献   

6.
To the best of our knowledge, bioanalytical methods to determine rosiglitazone in human plasma reported in literature use internal standards that are not commercially available. Our purpose was to develop a simple method for the determination of rosiglitazone in plasma employing a commercially available internal standard (IS). After the addition of celecoxib (IS), plasma (0.25 mL) samples were extracted into ethyl acetate. The residue after evaporation of the organic layer was dissolved in 750 microL of mobile phase and 50 microL was injected on to HPLC. The separation was achieved using a Hichrom KR 100, 250 x 4.6 mm C(18) with a mobile phase composition potassium dihydrogen phosphate buffer (0.01 m, pH 6.5):acetonitrile:methanol (40:50:10, v/v/v). The flow-rate of the mobile phase was set at 1 mL/min. The column eluate was monitored by fluorescence detector set at an excitation wavelength of 247 nm and emission wavelength of 367 nm. Linear relationships (r(2) > 0.99) were observed between the peak area ratio rosiglitazone to IS vs rosiglitazone concentrations across the concentration range 5-1000 ng/mL. The intra-run precision (%RSD) and accuracy (%Dev) in the measurement of rosiglitazone were <+/-10.69 and <-12.35%, respectively across the QC levels (50-1000 ng/mL). The extraction efficiency was >80% for both rosiglitazone and IS from human plasma. The lower limit of quantitation of the assay was 5 ng/mL. In summary, the methodology for rosiglitazone measurement in plasma was simple, sensitive and employed a commercially available IS.  相似文献   

7.
A highly selective, sensitive and accurate HPLC method has been developed and validated for the estimation of three fluoroquinolones (FQs) viz., gatifloxacin (GFC), sparfloxacin (SFC) and moxifloxacin (MFC) with 500 microL human plasma using levofloxacin (LFC) as an internal standard (IS). The sample preparation involved simple liquid-liquid extraction of GFC, SFC, MFC and IS from human plasma with ethyl acetate. The resolution of peaks was achieved with phosphate buffer (pH 2.5)-acetonitrile (80:20, v/v) at a flow rate of 1 mL/min on a Kromasil C(18) column. The total chromatographic run time was 18.0 min and the simultaneous elution of GFC, SFC, MFC and IS occurred at approximately 10.8, 12.8, 17.0 and 6.0 min, respectively. The method proved to be accurate and precise at linearity range of 100-10,000 ng/mL with a correlation coefficient (r) of > or =0.999. The limit of quantitation for each of the FQs studied was 100 ng/mL. The intra- and inter-day precision and accuracy values found to be within the assay variability limits as per the FDA guidelines. The developed assay method was applied to a pharmacokinetic study in human volunteers following oral administration of 400 mg GFC tablet.  相似文献   

8.
This work presents a high-performance liquid chromatography (HPLC) method for the quantitation of glucosamine in chitin. The method includes an acid hydrolysis of chitin. The chromatographic separation is achieved using a Hypersil ODS 5-microm column (250 x 4.6 mm) at 38 degrees C, with precolumn derivatization with 9-fluorenylmethyl-chloroformate and UV detection (lambda = 264 nm). The mobile phase is a mixture of mobile phase A [30 mM ammonium phosphate (pH 6.5) in 15:85 methanol-water (v/v)], mobile phase B [15:85 methanol-water (v/v)], and mobile phase C [90:10 acetonitrile-water (v/v)], with a flow rate of 1.2 mL/min. The HPLC method proposed showed adequate repeatability (relative standard deviation, 5.8%), accuracy (92.7% recovery), and sensitivity, with a detection limit of 2 microg/mL. The method is successfully applied to the quantitation of glucosamine for the determination of the purity of chitin from shrimp waste.  相似文献   

9.
In this work, a simple isocratic reversed-phase HPLC method for determination of alpha-tocopherol in human erythrocytes has been developed and validated. After separation of plasma the erythrocytes were washed three times with 0.9% sodium chloride containing 0.01% butylated hydroxytoluene (BHT) as antioxidant and then were diluted 1:1 (v/v) with the same solution. In the liquid-liquid extraction (LLE) procedure, 2500 microL of n-hexane was added to 500 microL of erythrocytes. After 2 min this mixture was deproteinized by addition of cool ethanol (500 microL, 5 min) denatured with 5% methanol containing alpha-tocopherol acetate (20 micromol L(-1)), as internal standard, and then extracted for 5 min by vortex mixing. After centrifugation (10 min, 1600xg) an aliquot (2000 microL) of the clean extract was separated and evaporated under nitrogen. The residue was dissolved in 400 microL methanol and analysed by reversed-phase HPLC on a 4.6 mmx150 mm, 5 microm Pecosphere C18 column; the mobile phase was 100% methanol, flow rate 1.2 mL min(-1). The volume injected was 100 microL and detection was by diode-array detector at a wavelength of 295 nm. The extraction recovery of alpha-tocopherol from human erythrocytes was 100.0+/-2.0%. The detection limit was 0.1 micromol L(-1) and a linear calibration plot was obtained in the concentration range 0.5-20.0 micromol L(-1). Within determination precision was 5.2% RSD (n=10), between determination precision was 6.1% RSD (n=10). The method was applied successfully in a clinical study of patients with acute pancreatitis and for determination of the reference values in the healthy Czech population.  相似文献   

10.
A simple and reliable HPLC method was developed for the simultaneous quantitative analysis of diethylene glycol (DEG) and propylene glycol (PG) in pharmaceutical products by precolumn derivatization. The derivatization reagent p-toluenesulfonyl isocyanate (TSIC, 10 microL, 20% in ACN v/v) was added to 100 microL of the sample, and then 10 muL of water was added. The resulting derivatives were separated using a C(18)analytical column and a mobile phase composed of 0.01 M KH(2)PO(4)buffer (adjusted to pH 2.5 with phosphoric acid) and ACN (47:53 v/v) at 1 mL/min and 25 degrees C. For detection, UV light at 227 nm was used. The derivatization conditions including reaction time, temperature, and concentration of TSIC were optimized. The calibration curves were linear from 0.062 to 18.6 microg/mL (r(2)= 0.9999) and from 0.071 to 21.3 microg/mL (r(2) = 0.9999) for DEG and PG, respectively. The RSD values of intra- and interday assays were all below 4% for DEG and PG. The proposed method was then successfully applied to analyze two Armillarisin A injection samples and two spiked syrup samples.  相似文献   

11.
The development and validation of a simple, rapid and selective high-performance liquid chromatography (HPLC) method is described for the quantitation of itraconazole and hydroxy-itraconazole in 100 microL of plasma from a paediatric population. The mobile phase of methanol (75% v/v) and water (25% v/v) was pumped at 1 mL/min through a C18 Symmetry (3.9 mm i.d. x 150 mm) cartridge. Using a protein-precipitation method, 100 microL internal standard (IS) solution (R051012, 555 microg/L in acetonitrile) were added to 100 microL of plasma followed by 10 microL zinc sulphate solution (20% w/v). Itraconazole, hydroxy-itraconazole and IS eluted at 4.7, 8.3 and 12.5 min, respectively and were detected fluorometrically at 250 nm (excitation) and 380 nm (emission). Recoveries were 87.1-96.7%. Calibrations in drug-free plasma were linear (r2 > 0.99) from 50 to 2000 microg/L, using 1/c2 (c = concentration) weighting. Intraday and interday imprecision (CV%) was 4.8-17.3 and 6.3-16.6% for itraconazole, and 4.6-17.9 and 7.02-18.4% for hydroxy-itraconazole. Inaccuracy was -7.1 to -14.7% for itraconazole and -0.1 to -9.7% for hydroxy-itraconazole. The clinical application of this method was demonstrated by measurement of itraconazole and hydroxy-itraconazole in plasma samples drawn from paediatric cystic fibrosis patients, who were prescribed itraconazole for treatment of allergic bronchopulmonary aspergillosis.  相似文献   

12.
A reversed-phase high-performance liquid chromatographic (HPLC) method for the simultaneous determination of clozapine and its two major metabolites, norclozapine and clozapine-N-oxide in human plasma has been developed and validated. The isocratic HPLC assay uses a mobile phase consisting of an acetonitril-buffered aqueous solution containing 146 microL of triethylamine and 200 microL of 85% phosphoric acid, adjusted to pH 3.3 with 10% potassiumhydroxide solution (400:600, v/v) at a flow-rate of 0.8 ml/min and a Lichrospher 100 RP-18 reversed-phase column and UV detection at 215 nm. Doxepine was used as the internal standard. Mean recoveries for clozapine, norclozapine, clozapine-N-oxide and doxepine were 95%, 98%, 96% and 94%, respectively, whereas the respective mean repeatability coefficients of variation were 3.4%, 2.7%, 4.3% and 0.9%. Reproducibility coefficients of variation were 1.3%, 1.8%, 3.6% and 0.5%, respectively. The mean correlation coefficient for the linear calibration curve (n = 2) for clozapine and norclozapine at a concentration range of 100-1600 ng/mL was 0.9998 and 0.9997, respectively; for clozapine-N-oxide (20-200 ng/mL) it was found to be 0.9986. The lower limits of quantitation were 12.5 ng/mL, 10 ng/mL and 12.5 ng/mL for clozapine, norclozapine and clozapine-N-oxide, respectively.  相似文献   

13.
Lead and cadmium concentrations in sewage sludge samples are determined by suspending the ground samples in a solution containing 10% (v/v) concentrated hydrofluoric acid, 1% (v/v) concentrated nitric acid, 0.5% (m/v) dihydrogen ammonium phosphate and 0.1% (m/v) sodium hexametaphosphate. Aliquots of 20 microL of these suspensions (4 mg/mL) are diluted to 1000 microL with the same solution and then injected into the electrothermal atomizer. The drying stage is performed by programming a 400 degrees C temperature, a ramp time of 20 s and a hold time of 15 s on the power supply of the atomizer. No ashing step is used. Platform atomization is carried out at 1600 and 1800 degrees C for Pb and Cd, respectively. Calibration is performed using aqueous standards in the 5-75 and 0.2-5 microg/L Pb and Cd ranges, respectively. Results obtained for three certified reference materials and four samples demonstrate the reliability of the procedures described.  相似文献   

14.
A simple and rapid high-performance liquid chromatographic (HPLC) method for determination of residual penicillin G (benzylpenicillin, PCG) in milk was developed. The sample preparation was performed by stirring with ethanol and reacting with 5 M 1,2,4-triazole-mercury (II) chloride solution at 65 degrees C for 10 min followed by an ultra centrifugation step. The HPLC separation was carried out using a Mightysil RP-4GP column, a mobile phase of acetonitrile and 0.1 M phosphate buffer (pH 6.5) (35:65, v/v) and a photo-diode array detector. The average recoveries from spiked PCG (0.004, 0.01, 0.05 and 0.1 microgram/mL) were above 86% with coefficients of variation between 1.2 and 4.5%. The limit of detection was 0.004 microgram/mL. This value corresponds to the maximum residue limit (MRL) in milk (0.004 microgram/mL, EU and Japan). The total time required for the analysis of one sample was below 40 min.  相似文献   

15.
A sensitive and specific LC-MS/MS assay for the determination of paclitaxel and its 3'p- and 6-alpha-hydroxy metabolites is presented. A 200 microL plasma aliquot was spiked with a 13C6-labeled paclitaxel internal standard and extracted with 1.0 mL tert-butylmethylether. Dried extracts were reconstituted in 0.1 M ammonium acetate-acetonitrile (1:1, v/v) and 25 microL volumes were injected onto the HPLC system. Separation was performed on a 150 x 2.1 mm C18 column using an alkaline eluent (10 mm ammonium hydroxide-methanol, 30:70, v/v). Detection was performed by positive ion electrospray followed by tandem mass spectrometry. The assay quantifies a range for paclitaxel from 0.25 to 1000 ng/mL and metabolites from 0.25 to 100 ng/mL using 200 microL human plasma samples. Validation results demonstrate that paclitaxel and metabolite concentrations can be accurately and precisely quantified in human plasma. This assay is now used to support clinical pharmacologic studies with paclitaxel.  相似文献   

16.
The electrophoretic separation of ribavirin and 5-methylcytidine (internal standard) by capillary electrophoresis was examined. Separation was achieved using reverse polarity in a 100 mM borate electrolyte, pH 9.1, with 5 mM spermine added to reduce the electroosmotic flow. Sample preparation based on acetonitrile protein precipitation was found to be unsuitable for ribavirin analysis in patient samples due to insufficient sensitivity and interferences. Solid-phase extraction employing phenyl boronic acid cartridges provided cleaner separations. Using this approach with 500 microL sample and reconstitution of the dried extract into 100 microL of 33% v/v 100 mM phosphate buffer, pH 6.4 / 67% v/v acetonitrile, the detection and quantitation limits were determined to be 0.05 and 0.10 microg/mL, respectively, a sensitivity that is suitable for therapeutic drug monitoring of ribavirin in human plasma and serum samples. The method was validated and compared to a high-performance liquid chromatography (HPLC) method, showing excellent agreement between the two for a set of samples that stemmed from patients being treated with ribavirin and interferon-alpha-2b for a hepatitis C virus infection.  相似文献   

17.
A simple and rapid high-performance liquid chromatographic (HPLC) method for determination of residual penicillin G (benzylpenicillin, PCG) in milk was developed. The sample preparation was performed by stirring with ethanol and reacting with 5 M 1,2,4-triazole-mercury (II) chloride solution at 65?°C for 10 min followed by an ultra centrifugation step. The HPLC separation was carried out using a Mightysil® RP-4GP column, a mobile phase of acetonitrile and 0.1 M phosphate buffer (pH 6.5) (35:65, v/v) and a photo-diode array detector. The average recoveries from spiked PCG (0.004, 0.01, 0.05 and 0.1 μg/mL) were above 86% with coefficients of variation between 1.2 and 4.5%. The limit of detection was 0.004 μg/mL. This value corresponds to the maximum residue limit (MRL) in milk (0.004 μg/mL, EU and Japan). The total time required for the analysis of one sample was below 40 min.  相似文献   

18.
A rapid and simple reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of clobazam concentrations in human blood samples is developed and validated. Solid-phase column extraction is performed to clean up blood samples before running the analytical HPLC system. The chromatography is isocratic with a mobile phase consisting of acetonitrile (20%, v/v), methanol (23%, v/v), and 0.1 M potassium hydrogen phosphate buffer (pH 3.6; 57%, v/v) at a constant flow rate of 2 mL/min. Clobazam is detected at 226 nm. Chromatography is completed within less than 25 min. The recovery rate is greater than 95% and linear over a wide range of drug concentrations. The intra-assay coefficient of variation percentage varies between 4.3 and 12. This method is used for therapeutic drug monitoring in patients undergoing antiepileptic therapy with clobazam. Plasma levels of clobazam ranged from 21 to 663 ng/mL. Other antiepileptic compounds, such as clonazepam and phenobarbital, did not interfere with the detection of clobazam.  相似文献   

19.
A rapid stability indicating reversed-phase high-performance liquid chromatography (HPLC) method is developed for the determination of the electrochemically controlled risperidone release from a novel drug delivery system, based on the intrinsically conducting polymer (ICP), polypyrrole. The chromatographic separation was carried out on a C(18) column using acetonitrile-potassium dihydrogen phosphate (45:55, v/v, pH 6.5; 0.05 M) as the mobile phase. The isocratic flow is at 1.0 mL/min, with a runtime of 6 min, and the UV detection is at 237 nm. This provided a calibration curve linear over the range of 1-100 μg/mL. Intra-day and inter-day accuracy range between 98.4% and 102.6%, and the RSD for precision is <1.43%. The limit of detection and quantitation were determined to be 0.001 μg/mL and 0.01 μg/mL, respectively. The analytical method confirmed risperidone is stable for the oxidizing electric potential and the acidic environment involved during the manufacture and operation of the novel drug delivery system. The rate of risperidone release from polypyrrole depended on electrical stimulation applied to the polymer. This HPLC method is significantly faster than previously published methods and is the first to investigate the effect of an oxidizing potential on risperidone stability, which is essential for the evaluation of controlled delivery from an ICP-based system.  相似文献   

20.
A direct plasma injection liquid chromatographic method has been developed for the determination of a new triazole antifungal agent, voriconazole, using an internal surface reversed phase column. Therapeutic drug monitoring of voriconazole is relevant for patient management, especially in the case of drug-drug interaction. The method is easy to perform and requires 10 microL of a plasma sample. The chromatographic run time is less than 9 min using a mobile phase of 17:83 v/v acetonitrile-potassium dihydrogen phosphate buffer, 100 mM, pH 6.0 and UV detection at 255 nm. The fl ow rate was 1 microL/min. A linear response was observed over the concentration range 0.5-10 microg/mL (r2 = 0.977). A good accuracy (bias < or = 7.5%) was achieved for all quality controls, with intra-day and inter-day variation coefficients inferior to 6.7%. The lower limit of quantitation was 0.2 microg/mL, without interference of endogenous components. The stability of voriconazole in plasma stored at different temperatures was checked. Finally, the possibility of direct injection of plasma samples into the column permits a reduction in reagent consumption and in analytical steps, and hence in analytical error.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号