首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
An IgE RIA kit (Sandwich method; Dainabott), is used to obtain the following results. (1) Standard curve: Since the range of reproduction rate show 3.16-7.07% (C.V.), the curve become steep. (2) Incubations under controlled situation: Both of the incubations are controlled at 15-30 degrees C for 2 h. (3) Reproducibility test: Coefficients of variation (C.V.) of intra-assay and inter-assay variation are 2.32-3.94% and 2.92-3.92% respectively. (4) Recovery test: A result of the recovery test range between 100.1-101.7%. (5) Dilution test: Multiple dilution effects are observed. (6) Average counts of the serum IgE for the controlled and diseased groups: The average counts of the serum IgE for the controlled group, atopic diseased group, allergic rhinitis group and allergic bronchial asthma are 144.9 +/- 183.2 IU/ml, 1,099.0 +/- 2,782.4 IU/ml, 1,150.9 +/- 2,063.3 IU/ml and 600.7 +/- 686.4 IU/ml respectively. The value of the diseased groups have tendency to show higher averages than the controlled group. Since the controlled and diseased groups show wide distributions of the serum IgE level, there is no significant difference of two variations. However the diseased groups have tendency to show higher ratio of the serum IgE level in blood than the controlled groups. These basic researches are quite meaningful, because they are able to apply for a supplemental diagnosis of the atopic and parasitic disease.  相似文献   

3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
We have measured serum ferritin level using double antibody radioimmunoassay kit (Eiken ICL) and evaluated the characteristics of the kit and clinical usefulness. Satisfactory results were observed in standard curve, reproducibility, dilution and recovery test. In clinical evaluation, we have measured in normal subjects and patients with various diseases. The range in normal males and females were 13.0-158.7 ng/ml and 7.3-73.0 ng/ml, respectively. Serum ferritin level was elevated in patients with hepatoma, biliary cancer, lung cancer and other malignant diseases. Measurement of serum ferritin value would be useful in the monitoring of cancer patients.  相似文献   

18.
19.
We have been studies time sequent stability each on standard human-C-peptide, human-C-peptide antiserum, 125I-tyrosyl human-C-peptide and the assay kit (all reagent) which is necessary in human proinsulin-C-peptide radioimmunoassay(RIA). Also we measured using this assay system, human proinsulin C-peptide in blood after oral administration of glucose to normal subject. Standard human-C-peptide and human-C-peptide antiserum were very stable on storage at 4 degrees C, 125I-tyrosyl human-C-peptide was unstable as compared with the former two, The stability of the assay kit was influenced by the stability of 125I-tyrosyl human-C-peptide, and was stable at 4 degrees C for ten weeks after preparation. Three lots of the assay kit prepared at different period showed almost same stability. We think this assay system using the assay kit is satisfactory in respect of stability. The measured values of human proinsulin-C-peptide in blood, using this assay system, showed insulin secretory reaction after oral administration of glucose.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号