首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The diacetylenic adducts, Fe2(CO)6{-EC(H) = C(C CMe)E} (E = E, E E; E, E = S, Se, Te) (1–8) have been obtained from the room temperature stirring of Fe2(CO)6(-EE) with HC CC CMe in methanol solvent containing sodium acetate. Compounds 1–8 have been characterized by IR and multinuclear NMR (1H, 13C, 77Se, and l25Te) spectroscopy. Trends in the chemical shifts of 77Se and 125Te NMR spectra of Fe2(CO)6{-EC(H) = C(C CMe)E} with a variation of EE are discussed.  相似文献   

2.
Summary The hydrocarbon composition of the particle and gas phases in the urban atmosphere has been studied by filtration and parallel adsorption on active charcoal and polyurethane foam (PUF). Gas chromatography (GC) and GC coupled to mass spectrometry (GC-MS) have been used for the analysis of the organic matter extracts obtained with each system. In the case of the particle and PUF samples these extracts were fractionated into aliphatic and aromatic compounds. This approach has allowed to identify up to 247 hydrocarbon molecules showing that C0–C5 alkylbenzenes are the major compounds in the charcoal extracts whereas C14–C23 n-alkanes, C0–C4 alkylnaphthalenes, C0–C4 alkylbiphenyls and C3–C5 alkylbenzenes are those predominantly found in the PUF materials. The particles essentially contain C17–C38 n-alkanes and parent polycyclic aromatic hydrocarbons (PAH). These qualitative differences are paralleled by a progressive concentration decrease from the more to the less volatile hydrocarbons. Thus, the total charcoal extracts average 80 g/m3, the PUF compounds represent 4 /m3 and the particle hydrocarbons 0.7 g/m3. These latter airborne materials are essentially composed of petrogenic residues 0.6 g/m3 (aliphatic fraction) whereas the pyrolytic PAH only involve 0.08 g/m3.  相似文献   

3.
    
Zusammenfassung Es werden Erfahrungen mit der Kombination von automatischem Aminosäurenanalysator und Szintillations-Durchflußzelle zur Bestimmung der spezifischen Radioaktivität 14C-markierter Aminosäuren im Gehirn mitgeteilt. Die Erfassungsgrenze beträgt 3 · 10–4 Ci/ml Eluat, die Reproduzierbarkeit 5–1% vom Mittelwert im Meßbereich von 1 · 10–3 bis 5 · 10–2 Ci.
A method for the determination of the specific radioactivity of free amino-acids in tissue extracts of mammals
Some experiences are given with a measuring device for the determination of the specific radioactivity of 14C-labelled brain amino-acids. The apparatus consists of an automatic amino-acid analyzer combined with a flow cell filled with anthracene. The reproducibility of the method is ±5% to ±1% m.e. in the range of 1×10–3 Ci to 5×10–2 Ci. A quantitative determination of 3×10–4 Ci/ml eluant is still possible.
  相似文献   

4.
The interference contributions of uranium and thorium to the determination of cerium based on radionuclides141Ce and143Ce produced by irradiation in a reactor core was determined. The values of the interference contributions for141Ce were 0.28±0.01 g Ce/g U and /2.01±0.05/x10–3 g Ce/g Th, and for143Ce 1.33±0.03 g Ce/g U and /9.0±0.2/x10–3 g Ce/g Th.  相似文献   

5.
Summary Nitrate was determined in natural water samples by flow-injection spectrophotometry. It was reduced to nitrite with copperized cadmium and the nitrite thus produced reacted with p-aminoacetophenone and m-phenylenediamine. The limit of detection was about 1.5 g l–1 for sample injections of 650 l. The sampling rate was about 40 samples h–1 and the relative standard deviation was above 1% for 0.1–0.3 mg l–1 nitratenitrogen. Nitrite present in the sample was determined separately and subtracted.
Nitratbestimmung in natürlichen Wässern mit Hilfe der Fließinjektions-Analyse
Zusammenfassung Nitrat wird bei dieser Methode mit Hilfe einer Cu/Cd-Reduktionssäule zu Nitrit reduziert, das mit p-Aminoacetophenon und m-Phenylendiamin zur Reaktion gebracht wird. Die gebildete Verbindung wird spektral-photometrisch gemessen. Die Nachweisgrenze beträgt etwa 1,5 g/l bei injizierten Probevolumina von 650 l. Der Probendurchsatz beträgt 40/h. Die relative Standardabweichung liegt über 1% bei 0,1–0,3 mg/l Nitrat-Stickstoff. Vorhandenes Nitrit wird gesondert bestimmt und abgezogen.
  相似文献   

6.
Zusammenfassung Eine neue Methode zur Durchführung gravimetrischer Bestimmungen im Mikrogrammbereich wurde beschrieben; diese beruht im wesentlichen darauf, daß der Niederschlag nicht mehr zusammen mit dem Filter, sondern nach Überführen mit einem geeigneten Lösungsmittel in einem separaten Wägegefäß gewogen wird.Die dazu nötigen Geräte und deren Herstellung wurden beschrieben. Nach dieser Methode wurden folgende Bestimmungen mit zufriedenstellender Richtigkeit durchgeführt: 2,5–25g Al, 5–50g Cu und 5–50g Zn mit Oxin, 2,5–25g Fe(III) und 2,5–25g Ti(IV) mit N-Benzoyl-phenylhydroxylamin, 5–50g Ni und 5–50g Cu mit Salicylaldoxim, 2,5–50g Co(II) und 2,5–50g Fe(III) mit -Nitroso--naphthol sowie 5–50g Chlorid als Silberchlorid.
Precipitation analysis in the microgram-scale: A new method
Summary A new method for gravimetric determinations in the microgram-scale is described. This method is based on the fact that the precipitate is not weighed together with the filter but is transferred to a separate weighingvessel using a suitable solvent. The necessary simple devices and their use are described. The following determinations were carried out with satisfying accuracy: 2,5–25g Al, 5–50g Cu and 5–50g Zn with Oxine, 2,5–25g Fe and 2,5–25g Ti withN-benzoylphenylhydroxylamine, 5–50g Ni and 5–50g Cu with salicylaldoxime, 2,52–50g Co and 2,5–50g Fe with -nitroso--naphthol and 5–50g chloride as silver chloride.
  相似文献   

7.
Chemical and electrochemical oxidation of rhodium (III) oxo-bridged carboxylate complexes was studied. The chemical [with O3 and Ce(IV) salts] or electrochemical (at potentials of 1.00-1.20 V) oxidations of the binuclear complexes [Rh2(-O)(-O2CCH3)2(H2O)6]2 + and [Rh2(-O)(-O2CCF3)2(H2O)6]2 + leads to the superoxo complexes [Rh2(-O)(O2-)(-O2CCH3)2(H2O)5]+ and [Rh2(-O)(O2 -)(-O2CCF3)2(H2O)5]+ with terminal coordination of O2-. The trinuclear acetate [Rh3(3-O)(-O2CCH3)6(H2O)3]+, unlike its trifluoroacetate analog [Rh3(3-O)(-O2CCF3)6(H2O)3]+, is oxidized only electrochemically at a potential of 1.38 V. The oxidation of [Rh3(3-O)(-O2CCH3)6(H2O)3]+ is reversible and involves formation of an unstable superoxo group O2 - between two Rh3III(3-O) cores.  相似文献   

8.
Isotope dilution mass spectrometry using enriched isotope96Ru as a spike was applied to the determination of ruthenium as a fission product. Ruthenium in the solution was oxidized to RuO4 by Ce/IV/ and separated from coexisting metal elements by distillation. Silica-gel technique was employed to enhance ion current of ruthenium in the mass spectrometric measurement. The lower detection limit was 0.005 g ml–1 and the relative standard deviations /n=3/ for 1.2 and 0.05 g ml–1 of ruthenium were 0.2 and 0.5%, respectively.  相似文献   

9.
Summary Tetramethylthiuram disulphide (TMTD) is used for the extraction and spectrophotometric determination ofg quantities of osmium. 15 ml of 1.052×10–3 M TMTD in toluene quantitatively extracts osmium from7 M HCl. The complex attains maximum colour intensity in 2 hours. It is red in colour and exhibits two max. One at 445 nm and the other at 504 nm. The maximum at 504 nm is more significant. Beer's law was found to hold good over the concentration range of 1.7 to 26.7g of osmium per ml. The Ringbom plot shows the optimum range of 9.42 to 23.65g of osmium per ml. The optimum period of equilibration is 30 seconds and the complex is stable up to 5 hours. The extracted species shows the composition to be 1 1 (Os TMTD). It is possible to extract and determine osmium in the presence of other platinum metals with composition corresponding to the ore osmiridium.
Zusammenfassung Tetramethylthiuramdisulfid (TMTD) wurde zur Extraktion und spektrophotometrischen Bestimmung von Mikrogrammengen Osmium verwendet. 15 ml einer 1,052.10–3-molaren Lösung von TMTD in Toluol dienen zur Extraktion von Os aus 7-m Salzsäure. Der entstandene rote Komplex erreicht innerhalb 2 Stunden maximale Farbintensität und zeigt zwei Absorptionsmaxima bei 445 nm und 504 nm. Letzteres ist signifikanter. Zwischen 1,7 und 26,7g Os/ml gilt das Beersche Gesetz. Nach der Ringbom-Gleichung liegt die geeignetste Konzentration zwischen 9,42 und 23,65g Os/ml. Nach 30 sec stellt sich das Gleichgewicht ein und bleibt bis zu 5 Stunden konstant. Die extrahierte Substanz entspricht der Zusammensetzung 1 1 (Os TMTD). Os läßt sich auch in Gegenwart anderer Platinmetalle so extrahieren und bestimmen.
  相似文献   

10.
The feasibility of depth profiling was studied by using a 193-nm ArF* excimer laser ablation system (GeoLas, MicroLas, Goettingen, Germany) with a lens array-based beam homogenizer in combination with an ICP-QMS Agilent 7500. Two ablation cells (20 and 1.5 cm3) were compared at the laser repetition rate of 1 Hz, laser beam energy of 135 mJ and the carrier gas flow rate 1.5 L min–1 He + 0.78 L min–1 Ar. The ablation cell dimensions are important parameters for signal tailing; however, very small cell volumes (e.g. 1.5 cm3) may cause memory effects, which can be probably explained by dominant inertial losses of aerosol on cell walls with its delayed mobilization. The 20-cm3 ablation cell seems to be appropriate for depth profiling by continuous single-hole drilling. The study of the influence of the pit diameter magnitude on the waning and emerging signals under small crater depth/diameter aspect ratios, which range between 0.75 and 0.0375 for the 3-m-thick coatings and pit diameters 4–80 m, revealed that the steady-state signals of pure coating and pure substrate (out of interface) were obtained at crater diameters between 20 and 40 m. Depth resolution defined by means of slopes of tangents in the layer interface region depend on the pit diameter and has an optimum value between 20 and 40 m and gives 0.6 m for the 20-m pit. In-depth variation of concentration of coating constituent (Ti) was proved to be almost identical with two different laser/ICP systems.Viktor Kanický performed this work while on leave at ETH Zurich  相似文献   

11.
A method has been developed for photometric detection of cyclodextrins (CD) in liquid chromatography using iodine (I2) generated electrochemically in-situ. Iodide ion in the mobile phase was electrochemically oxidized to I2 which was subsequently reacted with I, in an electrochemical flow cell, forming I3. The absorbance of I3 was found to be greatly enhanced when CD were present in the mobile phase. The absorbance enhancement was caused by the change in the mole fraction of I3, because of the inclusion reaction of I3 with CD. On the basis of this phenomenon, CD were detected by means of a photodiode-array UV–visible detector positioned downstream of the electrochemical flow cell. The signals were found to be linearly dependent on CD concentration. Because the formation constants of I3 with CD decrease in the order -CD>-CD>-CD, -CD was most detectable by the method. Detection limits were 1.0 mol L–1 for -CD, 65 mol L–1 for monoG1--CD, 100 mol L–1 for -CD, and 200 mol L–1 for -CD.  相似文献   

12.
    
Summary Optimum for the generation of arsine from As(III) and (V) in a generating system without carrier gas and with atomization in an air-acetylene flame were established. A 3% solution of NaBH4 was used as reducer. The effect of 26 different species on the determination of arsenic was studied. The method has been applied to determine arsenic in copper.A linear relationship exists between 0.5 and 3 g for As(III) and between 1 and 4 total g of As(V). The sensitivity, expressed as the slope of the calibration curve is 0.067 g–1 for As(III) and 0.054 g–1 for As(V); the characteristic masses are 1.22 g and 0.44 g, and the limits of detection 0.27 g and 0.33 g, respectively.
Direkte Flammen-AAS — Erzeugung flüchtiger kovalenter HydrideStörungen durch das Verhältnis der As(III/V)-Valenzstufen und Arsenbestimmung in Kupfer
Zusammenfassung Optimale Bedingungen wurden ausgearbeitet für die Arsinerzeugung aus As(III) und As(V) in einem System ohne Trägergas mit Atomisierung in einer Luft-Acetylen-Flamme. Zur Reduktion dient eine 3%ige NaBH4-Lösung. Der Einfluß von 26 Fremdionen wurde geprüft und das Verfahren zur Arsenbestimmung in Kupfer angewendet. Eine lineare Beziehung ergab sich für 0,5–3 g As(III) und 1–4 g As(V). Die Empfindlichkeit (als Neigung der Eichkurve) beträgt 0,067 g–1 für As(III) und 0,054 g–1 für As(V). Die charakteristischen Massen sind 1,22 g bzw. 0,44 g und die Nachweisgrenzen 0,27 g bzw. 0,33 g.


This work has been sponsored by the CAICYT (project 3378/83) of the Spanish Education and Science Department.  相似文献   

13.
Summary A simultaneous capillary Gas Chromatographic-Mass Spectrometric (GC-MS) method is described for the determination of thirteen pesticides belonging to the triazine and amide families in water. The sample is extracted in liquid-liquid mode (dichloromethane) and then the determination of the residues is carried out by capillary gas chromatography with mass spectrometric detection in the Selected-Ion Monitoring mode (SIM). The average recoveries of spiked compounds are in the 78.4–135.4% range between the relative low level (0.100 g L–1) and the relative high level (10.0 g L–1). The limits of detection (LOD) are in the 0.009–0.128 g L–1 range.  相似文献   

14.
Yields of n-C4H10 have been measured from the flow pyrolysis of C2H4 at 897 (±7) K. From 77 to 720 Torr the order of n-C4H10 formation was found to be 2.0±0.3 The rate constant for the reaction, was estimated to be 2.4(±0.6)×10–4l mol–1s–1.
-C4H10 C2H4 897 (±7) . -C4H10 77 720 2.0±0.3. 2C2H4C2H3+C2H5 2,4 (±0,6)×10–4 –1–1.
  相似文献   

15.
A high-performance liquid chromatographic method with photodiode array detection has been developed for the determination of squalene. After treated by extraction and fractional crystallization, squalene was analyzed on a C18 column (150 × 3.9 mm, 5 m) with acetonitrile as mobile phase. Excellent linearity of the calibration curve was observed in the range of 100–40000 gL–1 and the detection limit was 40 gL–1. The recoveries were from 89.6% to 100.5% and the relative standard deviations were from 0.5% to 1.4%. The method was successfully applied to the determination of squalene in squalene capsules, olive oil, algal lipids and algal cells.  相似文献   

16.
ET-AAS is investigated for the analysis of high purity mercury. Two possibilities are proposed: ET-AAS determination of trace analytes in the presence of high mercury concentrations or after matrix separation by reduction. The ET-AAS analysis of high-purity mercury under optimal instrumental parameters permits fast and reproducible determination of 0.03 gg–1 Al, Cd and Mn; 0.05 gg–1 Cu, Co, Cr, Fe, Ni and Pb and 0.2 gg–1 V. Preliminary mercury matrix reductive separation with ascorbic acid allows determination of 0.005 gg–1 Cd, 0.02 gg–1 Cu, Cr and Mn, 0.03 g g–1 Co, Ni and Pb, 0.05 g g–1 Al and Fe and 0.1 gg–1 V, but the reproducibility is lower. The main advantage of the second procedure is that it avoids laboratory and instrument pollution with toxic mercury.  相似文献   

17.
The trace metal loading of used car and truck tires and the fractions of the metals volatilized upon incineration of the tire were determined. INAA was chosen due to its multielement analysis capability and its low detection limit for many elements. A high purity planar germanium detector was used. Among the elements measured were, Al (4–150 g/g), Ti (41–730 g/g), V (0.04–0.4g/g), Mg (>80–580 g/g), Zn (1–2.2%) as typical concentrations; also some amounts of antimony, bromine and arsenic have been found. Major differences in elemental concentrations have been observed between the tread and the wall of a tire, and also between different brands.  相似文献   

18.
A high-performance thin layer chromatographic method coupled with densitometric analysis has been developed for measurement of benazepril and cilazapril, both pure and in their commercial dosage forms. The active substances were extracted from tablets with methanol (mean recovery 102%) and chromatographed on silica gel 60 F254 HPTLC plates in horizontal chambers with ethyl acetate–acetone–acetic acid–water, 8:2:0.5:0.5 (v/v), as mobile phase. Chromatographic separation of these ACE inhibitors was followed by UV densitometric quantitation at 215 nm. Calibration plots were constructed in the range 0.4 to 2.0 g L–1 for benazepril (2.0–10.0 g spot–1) and from 0.5 to 1.5 g L–1 for cilazapril (4.0–12.0 g spot–1) with good correlation coefficients (r 0.990). The method was used to determine benazepril and cilazapril in pharmaceutical preparations with satisfactory precision (1.4% < RSD < 5.6%) and accuracy (1.7 < RE < 5.1).  相似文献   

19.
A method, based on the measurement of the -photopeak at 332 keV arising from a124Sn(n, )125mSn reaction, has been developed for the rapid measurement of Sn at concentrations of 20 g g–1, present as the cross-linking agent, in explosive charges. The method is comparative, and has a limit of detection of 0.6 g g–1 and a precision of 5% RSD. The method requires no sample preparation and is economical in effort.  相似文献   

20.
Summary In natural waters, heavy metals such as Cd may be present in bound form. It is, therefore, important to consider chemical speciation, especially at low concentrations of the metal where a significant part can be bound by other trace constituents so tightly that it escapes several forms of its determination. It has been demonstrated that even the very strong complexant APDC is unable to leach out all of the heavy metal present in several coastal water samples from the German Bight.This paper describes a new micro method for the determination of total Cd in natural waters. First a small sample is dried in a polypropylene vial. Then the salt residue is heated to 90° C with a mixture of sulphuric and nitric acid for digestion of organic trace constituents (and oxidation of sulphides if present). After dilution subsamples are neutralized using an excess of NaHCO3 buffer solution. Extraction results are then independent from the possible slight variations of pH. The extractant, a solution of APDC in CCl4 is stable for weeks, and even the extract is stable for at least 16h. Precision is in the range of 7% at a concentration of 0.066 g Cd l–1; the detection limit is below 0.002 g l–1 and can be lowered, if necessary, by enlargement of the original sample. According to the sensitivity of the method the typical blank of 0.022 g Cd l–1 is high, but it is rather constant (mean variation from the mean: 0.0024 g l–1).Teil XI: Fresenius Z. Anal. Chem. 299, 206–207 (1979)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号